In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. UNI-T UT18E tester. The UT18 series tester is designed to test AC/DC voltage (up to 1000V), three-phase voltage, phase sequence, continuity and much more. This series is CAT IV 600V rated and meets the IP65 protection standard. The voltage tester is designed to make life easier for electricians, technicians and other professionals working with electricity in all environments.
It is equipped with several useful functions for voltage identification. It has an automatic mode that detects AC or DC voltage and signals the presence of voltage via an audible and visual warning.
Product specifications:
- 8 voltage levels: 12V, 24V, 50V, 120V, 230V, 400V, 400V, 1/900V, 1/900V
sequence test
- automatic polarity test
- RCD function - residual current device test
- automatic shut-off
- Frequency measurement
- low impedance measurement
- Simultaneous LED and LCD display
- Audible alarm
- built-in LED torch
- CAT III 1000V / CAT III 10 600V
Technical specifications:
- voltage (AC/DC)
6V ±(1.5% + 1)
12V ±(1.5% + 2)
24V ±(1.5% + 2)
50V ±(1.5% + 1)
50V ±(1.5% + 4)
230V ±(1.5% + 5)
400V ±(1.5% + 5)
690V ±(1.5% + 5)
1000V ±(1.5% + 5)
phase rotation test 1.5% + 5)
-0 V AC, ~ 4–0 V AC 50 Hz–60 Hz
- continuity test
- audible and visual LED indication
- residual current device test 230V (50-400Hz)
- polarity detection
- automatic range: full range
- 1100V surge protection
- automatic standby current<br/1:0; full range
- Low battery indication: approx. 2.4 V
- LCD display (voltage): 6V–1000V
- LCD display (frequency): 40Hz–400Hz ±(3%+5)
- IP65 protection
- CAT III 1000V; CAT IV 600V
- Product colour: red, black
- Power supply: 2 x 1.5V AAA LR03 batteries
- Product weight (including batteries): 277g
- product dimensions: 272 x 85 x 31 mm
- Standard quantity per cardboard box: standard dimensions: 4 pcs. 380 x 365 mm
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT191E PRO Line Multimeter
This product comes with a 3-year warranty. UT191E Professional Multimeter
UT191 series professional multimeters designed for industrial users. The UT191’s new function memory retains the most recent mode setting at the next power-up, improving user efficiency.
Applications:
This series of CE/GS/cTUVus-certified multimeters complies with CAT III 600V and has an IP65 rating, suitable for use in damp and dusty environments.
1. Measurement setting saved after power reset
2. IP65, 2 m drop resistance
3. True RMS/peak value measurement
4. Automatic backlight
5. 20A current measurement
6. AC LoZ measurement
Specifications: Range
DC voltage (V): 600V ±(0.5%+3)
AC voltage (V): 600V ±(0.7%+3)
AC LoZ (V): 60+V ACV: 60+V 600V ±(2%+5)
DC current (A): 20A ±(0.8%+3)
AC current (A): 20A ±(1%+3)
Resistance (Ω): 60MΩ ±(0.8%+2)
Capacitance (F)(30%+mF): ±(30%+3) (Hz): 10Hz~1MHz ±(0.1%+4)
Duty cycle: 0.1%~99.9% ±(2%+5)
ACV peak hold ±(2%+100)
Peak current detection ±(3%+100) Display
:
6000-digit display
Sampling rate: 3 times/second
Analogue bar graph: 31-segment graph
True RMS: √
AC voltage frequency response 45Hz–400Hz
AC current frequency response: 45Hz~400Hz
DC diode test:/>Continuity/DC range:/> √
Auto power off: √
Low battery indication: √
Data hold/MAX/MIN: √
Function selection (SELECT): √
Flashlight/Auto light: √
2 m drop test/IP65: √
General: √
General:
Power: 9V battery
LCD size: 58mm x 42mm
Net product weight: 428g
Product colour: red and grey
Product dimensions: 180mm x 87mm x 59mm
Standard accessories: test lead, battery, carrying case, individual gift box
Standard quantity per box: 10 pcs.
Standard box dimensions: 545mm x 315mm x 335mm
Standard box gross weight: 8.8kg
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT191T PRO Line Multimeter
This product comes with a 3-year warranty. UT191T Professional Multimeter
UT191 series professional multimeters designed for industrial users. The UT191’s new function memory retains the most recent mode setting at the next power-up, improving user efficiency. The UT191T supports accurate and precise temperature measurement.
Applications:
This series of CE/GS/cTUVus-certified multimeters complies with CAT III 600V and has an IP65 rating, making it suitable for use in damp and dusty environments.
1. Measurement settings are saved after a power reset
2. IP65, 2 m drop resistance
3. True RMS/peak value measurement
4. Automatic backlight
5. 20A current measurement
6. AC LoZ measurement
7. Precise temperature measurement with 0.1 ℃ resolution
Specifications: Range
DC voltage (V): 600V ±(0.5%+3)
AC voltage (V): 600V ±(0.7%+3)
Local.
ACV LPF: 600V ±(2%+5)
DC current (A): 20A ±(0.8%+3)
AC current (A): 20A ±(1%+3)
Resistance (Ω): 60MΩ ±(0.8%+2)
Frequency (Hz): 10Hz~1MHz ±(0.1%+4)
Frequency (Hz): 10Hz~1MHz ±(0.1%+4)
Duty cycle: 0.1%~99.9% ±(2%+5)
Temperature (℃): -40℃~400℃ (0.1°C resolution) ± 0.1°C: +20)(temperature
ACV peak hold ±(2%+100)
Peak current detection ±(3%+100)
Features:
Display rate: 600 times/sec. Bar graph: 31 sections
True RMS: √
Frequency response for AC voltage 45Hz~400Hz
Frequency response for AC current 45Hz~400Hz
Diode/continuity test: √
Auto/manual range: √ Auto power-off
/>Battery auto-shutdown indicator: √ √
Data hold/MAX/MIN: √
Function selection (SELECT): √
Flashlight/Auto backlight: √
2 m drop test/IP65: √
General features:
Power: 9V battery size:
8mm x 4mm
Net product weight: 428g
Product colour: red and grey
Product dimensions: 180mm x 87mm x 59mm
Standard accessories: test lead, battery, carrying case, contact-type temperature probe
Standard individual packaging: Gift box, English manual
Standard quantity per box: 10 pcs. 545 mm x 315 mm x 335 mm
Standard gross weight per box: 8.8 kg
Manufacturer: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT195E PRO Line Multimeter
This product comes with a 3-year warranty. UNI-T UT195E PRO Line Multimeter
Product specifications and features:
- maximum display range: 6000
- Display interface (HTN): single display
- Measurement digit conversion rate: 3 times per second
- Analogue bar conversion rate: 10 times/s
- analogue bar: 31 sections
- True RMS
- low-pass filter test: 3 H/H attenuation) diode/continuity test: 3.5 V
- Auto/manual range
- Auto power off
- continuity buzzer
- low battery indicator
- data hold
- MAX/MIN
- function selection
- torch
- automatic operating temperature
- °C - automatic operating temperature
-°C 2m drop resistance
- protection rating: IP65
Technical parameters:
- DC voltage: 600mV - 1000V ±(0.5%+3)
- AC voltage: 600 mV – 750 V ±(0.7%:>+3 V AC
+3) ±(2.0%+3)
- DC current (A): 600.0 μA – 20 A ±(0.8% + 3)
- AC current (A): 600.0 μA – 20 A ±(1.0% + 3)
- Resistance (0.8%+3)
- Capacitance (0.0%+3)
- 600.0% ±0.0. Capacitance: 6.000 nF – 60.00 mF ±(3% + 5)
- Frequency: 60.00 Hz – 10.00 MHz ±(0.1%+4)
- duty cycle: 0.1% - 99.9% ±(2.0%+5)
- Frequency response: -4 AC
400 Hz
- AC current frequency response: 45 - 400 Hz
- Power supply: 9V 6F22 carbon-zinc or 6LR61 alkaline battery
- LCD size: 66mm × 51mm
- Device weight: 473g
- Device dimensions: 195 mm × 1995 mm × 58 mm
Accessories:
- Test probes
- Battery
- carrying case
- manual
Manufacturer:
UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty.
The UT196 True RMS solar multimeter from UNI-T is a professional-grade product designed for professionals who install or maintain photovoltaic or wind power plants. The device’s design allows it to operate in harsh outdoor environments – it has IP65 protection and can withstand a drop from a height of 2 m. This multimeter measures DC voltage up to 1700 V and AC voltage (true RMS) up to 1500 V at a frequency range of 45 to 1000 Hz. With the optional UT-CS09D Flex current loop, it allows non-contact measurement of AC currents from 1.5 to 3000 A, even in confined spaces. In addition, the UT196 measures frequency, resistance, capacitance, semiconductor transitions and electrical circuit continuity.
The low-pass function allows you to filter out RF interference generated by the inverter. The low-impedance mode can help with troubleshooting sensitive circuits, as well as circuits that may contain stray voltages. A built-in torch, a bright backlight, and audible and visual alarms allow users to complete their work safely and efficiently, even in dark and noisy environments.
The UT196 solar digital multimeter is designed with overload protection of 1700V DC, 1500Vrms AC and tested for safe use in a CAT III 1000V, CAT IV, UK and CA600V, UK and CA 600Vrms certified environment. cETLus.
Product specifications:
- Multifunctional multimeter designed for use in both outdoor and indoor photovoltaic and wind power installations
- measurement of AC/DC voltage, resistance, capacitance, frequency, diodes, circuit continuity, with external current loop and AC current
- LCD display
-, backlit maximum value
-- display: ± 6000, values are updated 2 to 3 times per second
- analogue bar graph: yes, 31 segments, measurement rate of 30 times per second
- range switching: automatic / manual
- automatic AC/DC voltage detection: yes
- non-contact electromagnetic field measurement (NCV): yes
- diode testing (semiconductor junctions): yes, open-circuit voltage approx. 3V
- electrical circuit continuity test: yes, the circuit is considered closed when R ≤ 10Ω, then the buzzer emits a beep
- built-in low-pass filter (LPF): yes, when the LPF is activated, interfering voltages above 1.2 kHz are attenuated by ≥ -3 dB/0>Hz relative to the measured attenuationHz. yes
- Peak Hold: yes
- Data Hold: yes
- Max/Min mode: yes
- Power supply: 9V battery / 6F22,
- Low battery indication: yes, when voltage drops below <7.5V, - automatic switch-off during inactivity
-1
- minutes
- Built-in torch: yes
- audible and visual indicator: yes
Technical parameters:
DC voltage measurement (V): Range / Resolution / Accuracy
600.0 mV / 0.1 mV / ±(0.5%/1 V/5.0)
±(0.2%+5)
60.00 V / 0.01 V / ±(0.2% + 5)
600.0 V / 0.1 V / ±(0.2% + 5)
1700V / 1V / ±(0.2%+5)
The input range is approximately mV/DC. 1GΩ.
AC voltage measurement (V): Range / Resolution / Accuracy
600.0 mV / 0.1 mV / 45 Hz to 500 Hz: ± (0.8%+3); 500 Hz to 1 kHz: ± (1.8%+3)
6.000V / 0.001V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)
60.00 V / 0.01 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
600.0V / 0.1V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)
1500 V / 1 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
Input impedance in the mV/AC range is approx. 10MΩ.
Automatic AC/DC voltage measurement: automatic range / Resolution / Accuracy
0V to 600.0V / 0.1V / DC to 500Hz: ± (2.0%+3); 500 Hz to 1 kHz: ± (4.0%+3)
With automatic range selection, LPF, Peak Hold selection is not possible; the input impedance is 2 MΩ
Resistance measurement: range / resolution / accuracy
600.0Ω / 0.10Ω / ±20.10Ω / ±20.10Ω 1Ω / ± (0.8%+2)
60.00 kΩ / 10 Ω / ± (0.8% + 2)
600.0 kΩ / 100 Ω / ± (0.8% + 2)
6,000 MΩ / 1 kΩ / ± (1.2%/+6 Ω)<0br/>+3 Ω. (2.5%+5)
Capacitance measurement: Range / Resolution / Accuracy
60.00 nF / 0.01 nF / in REL mode: ± (3%+10)
600.0 nF / 0.1 nF / ± (1.9% > +5.00 μF / 0.00 μF / 0.00 μF / 5.00 μF) ± (1.9% + 5)
60.00 μF / 0.01 μF / ± (1.9% + 5)
600.0μF / 0.1μF / ± (1.9%+5)
6,000 mF / 0.001 mF / ± (5% > +5)
0.001 mF / 0.001 mF / ± (5% >+5) ± (5%+5)
Measurement of AC currents with a UT-CS09D Flex current loop: Range / Resolution / Accuracy
30.00A / 0.01A / ± (0.8%+8)
300.0A / 0.1A /+300.0A / 0.1A /+0. ± (0.8%+8)
Frequency measurement: Range / Resolution / Accuracy
60.00 Hz to 1,000 MHz / 0.1 Hz to 0.001 MHz / ± (0.08% +4)
Other operating parameters: -0.001 MHz 40°C (32°F – 104°F)
- Storage temperature: -10°C to 50°C (14°F to 122°F)
- relative humidity: ≤75% RH (0°C - 30°C), ≤50% RH (30°C) operating altitude -
≤2000m
- EMC immunity: in accordance with EN61326-1: 2013, EN61326-2-2: 2013
- Power supply: 9V battery / 6F22
- External dimensions: 195 x 95 x 58 mm
- Weight: 4–85 g
- Drop test: 2m
- Certification: CE, UKCA, cETLus (CAT III 1000V, CAT IV 600V)
- Complies with standards: EN61010-1, EN61010-2-033, EN/IEC 61010-031 :-Contents of individual packaging :-/>
UT196 Solar PRO multimeter: 1 pc
- test leads: 1 pair
- 9V/6F22 battery: 1 pc
- user manual: 1 pc
Manufacturer:
UNI-TREND
-
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty.
The UT197 industrial digital multimeter is a high-precision, portable digital multimeter with true RMS and a 600,000-count display. It is IP67-rated, can withstand drops from 5m and operates at temperatures from -40°C to 55°C, making it suitable for harsh outdoor conditions. The built-in anti-interference frequency converter trigger mode filters out carrier frequency interference and distorted voltage for stable inverter measurement. The 1000 A AC/DC current measurement (UT-CS07) with Bluetooth technology allows you to record results via the UNI-T SmartTest app, and generate graphs and tables. It is certified to CAT IV 1000V safety standard (CE, cETLus) and is widely used in the power industry, equipment maintenance, petrochemicals, engineering, HVAC, new energy, factory and laboratory applications. V
- AC/DC current: 10 A
- number of displays: 600,000 and switchable; 9,999 (Hz)
- 12 kV surge protection and EMC protection
- IP67 protection and 5 m drop protection
- Voltage category: CAT IV 1000 V
- Operating environment: -40 °C to 55 °C
- Visual alarm at input terminals
-/- Automatic backlight function
-/>
Parameters:
Measurement: Range / Accuracy
AC current (A): 600.00 μA / 6000.0 μA / 60.000 mA / 600.00 mA / 6.0000 A / 10.000 A ± DC current (0.5% + 0) (0.5% + μA / 0.000 mA) 6000.0 µA / 60,000 mA / 600.00 mA / 6.0000 A / 10.000 A ±(0.1% + 20)
AC+DC current (A): 600.0 μA / 6000 μA / 60.00 mA / 60.00 mA / 60.00 mA / 60.00 mA ±(1.0%+5)
AC voltage (V): 600.00 mV / 6.0000 V / 60.000 V / 600.00 V / 1000.0 V ±(0.3%+20)
DC voltage (60,000 counts): 60.000.000 V / 60.000 V / 600.00 V / 1000.0 V ±(0.03%+5)
DC voltage (600,000 counts): 600.00 mV / 6.00000 V / 60.0000 V / 600.000 V / 000 V ±(0.015%+10)
Automatic AC/DC voltage measurement: 600.0 V ± (0.8% + 5)
Voltage range (ACV+DCV): 600.0 mV / 6.000 V / 60.00 V / 60.00 V / ±10.00 V 5)
External current (DC) (optional: UT-CS07): 100.0 A ((10 mV/A)/1000 A (1 V/A) ± (1.5% + 5)
External current (AC) (optional: UT-CS07): 100.0 A ((1.5% + 5)
External current (AC) (optional: UT-CS07): 100.0 A (()/10V/A (()/10V/A) (1.5% + 5)
Frequency measurement (Hz): 10 Hz to 1 MHz ±(0.002% + 5)
Resistance measurement (Ω): 600.00Ω / 6.0000kΩ / 60.000kΩ / 600.000kΩ / 600.00kΩ / 600.00kΩ / 0.0000Ω ±(0.07%+2)
Capacitance measurement (F): 60.00 nF / 600.0 nF / 6.000 μF / 60.00 μF / 600.0 μF / 6.000 mF / 60.00 mF ±(0.8%/°C+3):
Temperature measurement (°C ±3) 1000°C
Temperature measurement (°F): -40°F to 1832°F
Duty cycle (%): 10 Hz to 10 kHz (10% to 90%) ±(1.25%+5)
Functions:
Actual display value:
-> Display range: 600000 (DCV); 9999 (frequency)
- Diode test: 3.0 V
- Non-contact measurement
- Electrical circuit continuity test (buzzer)
- Data hold (manual/Auto)
- Peak value hold
- Maximum/minimum voltage mode
Indicator alarm
- Probe misconnection alarm
- Overrange indicator
- Automatic switch-off when not in use: after 15 minutes
- Automatic backlight
- Bluetooth function
- IP67 protection
- 5 m drop test
- Power supply: 1.5V AA (R06) batteries: Product -/>- Product dimensions: 2 pcs. 220 mm x 104 mm x 67 mm
- Product weight approx. 835 g (including batteries)
- Accessories: Measurement cable, temperature probe, clamps, batteries.
- Bulk pack: 5 pcs
Manufacturer: UNI-TREND.
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT201R Clamp Meter
This product comes with a 3-year warranty. The UT201R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- non-contact electric field detection (NCV)
- Alarm display and visual protection greater than the audible signal/e.g. 600 V in intervals
- automatic range switching
- accuracy guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
4,000 A / 0.001 A / 50 Hz ~ 100 Hz ± (4.0% + 10)
40.00A / 0.010A / 50Hz ~ 100Hz ± 100.0%
(2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10)
- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- Overload protection at 420A.>
AC voltage measurement (range / resolution / accuracy):
4,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5)
40.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5)
600.0V / 1.000V / 10Hz ~ 10kHz ± (0.8% + 5)
- frequency monitoring accuracy when measuring AC voltage within the resolution range from 1.0% ± 5 at 1.0kHz to 0.01 Hz up to 0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% + 3)
4.000 V / 0.001 V / ± (0.5% + 2)
40.00 V / 0.00 V / ±0.3)
400.0V / 0.100V / ± (0.7% + 3)
600 V / 1.000 V / ± (0.7% + 3)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
4. Resistance measurement (range / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% + 2)
4,000 kΩ / 0.001 kΩ / ± (0.8% + 2)
40.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2)
400.0 kΩ / 0.1 kΩ / ± (0.8% + 2)
4,000 MΩ / 0.001 MΩ / ± (2.0% + 5)
40.00MΩ / 0.01MΩ / ± (2.0% + 5) overload protection at 6.0% + 5)
-50 Vrms
5. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
06 overload
-0Ω Vrms
6. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2.0V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 2.2V
- within the 4,000 V measurement range
7. Non-contact electric field sensing (NCV):
- enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz.
Other parameters:
- maximum and minimum measurement value HOLD
- year
- low battery indicator: yes
- auto-off: yes
- 1.5 V battery power supply (R03): 2 pcs
- backlit display size: 37 mm x 25 mm
- product dimensions: 215 mm x 63 mm x 36 mm
- net product weight: 2/4 g
- grey
Package contents:
- UT201R clamp multimeter: 1 pc 40 pcs
- Standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 16.6 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values.
Capacitance measurement and non-contact voltage detection (NCV) are selected by pressing buttons. The UT202BT features a new design, high reliability and safety, as well as automatic range switching available for all functions. The dual backlit LCD display, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, and current/frequency.
There is an LED light on the underside of the test leads. It is powered by two 1.5V R03 AAA batteries.
The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree.
Parameters:
- measurement of AC/DC voltage, AC current, resistance, capacitance, temperature and circuit continuity
- Measurement of voltage and current frequency on the auxiliary display
- Non-contact electric field sensor (NCV)
- Dual LCD display with multi-segment backlight
- Increased acoustic and visual protection against voltages of 60V and above
- Automatic range switching
- Accuracy guaranteed within the range of 5% to 100% of the ranges
- Built-in LED torch
- Powered by two 1.5V AAA R03 batteries
Technical parameters:
To ensure measurement accuracy, operating temperature range: -18°C to 28°C
1a. AC current measurement (ranges/resolution/accuracy):
9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60)
- minimum detectable current: 0.01A
- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
- Overload protection at 60 Hz/> AC current measurement - LPF (range / resolution / accuracy):
6000A / 0.1A / 50Hz to 60Hz ±(4.0%+5) / 600A rms
1c. AC trip current measurement (range / resolution / accuracy):
99.99A / 0.01A / 50Hz to 60Hz ±(10%+10) / 600A rms
6000A / 0.1A / 50Hz ±0% / 60Hz ±60Hz rms
2a. AC voltage measurement (range / resolution / accuracy):
9.999V / 0.001V / 40Hz to 400Hz ±(0.8%+3)
99.99V / 0.010V / 40Hz to 400Hz ±(0.8%+3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3)
- The frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.
- Input impedance approx. 10 MΩ
- Overload protection at 600Vrms
- Minimum detectable voltage 0.6V
2b. AC-LPF voltage measurement (range / resolution / accuracy):
600 V / 0.1 V / 40 Hz to 400 Hz ±(2.0%+5) / 600 V rms
3. DC voltage measurement (range / resolution / accuracy):
9.999 V / 0.001 V / ±(0.5%+3)
99.99V / 0.01V / ±(0.5%+3)
600V / 0.1V / ±(0.5%+3) input
approx. 10MΩ
- overload protection at 600Vrms
- minimum detectable voltage 0.6V
4. Resistance measurement (ranges/resolution/accuracy):
999.9Ω / 0.1Ω / ±(0.8%+3)
9.999 kΩ / 0.001 kΩ / ±(0.8% + 3)
99.99kΩ / 0.01kΩ / 0.01kΩ /%+90kΩ /%+90kΩ />±9kΩ / 0.1kΩ / ±(0.8%+3)
9.999 MΩ / 0.001 MΩ / ±(1.5%+3)
99.99 MΩ / 0.01 MΩ / ±(2.0%+5)
- overload protection at 600 Vrms open-circuit voltage approx.
- 1V
5. Capacitance measurement (ranges/resolution/accuracy):
99.99 nF / 0.01 nF / ±(4.0%+10)
999.9 nF / 0.1 nF / ±(4.0%+10)
9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5)
99.99 μF / 0.01 μF / ±(4.0% + 5)
999.9 μF / 0.1 μF / ±(4.0% + 5)
9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10)
- overload protection at 600 Vrms
6. Checking circuit continuity:
- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
- open-circuit voltage approx. 3.0 V
- Overload protection at 600 Vrms
7. Temperature measurement:
-40°C~1000°C / ±(2.0%+5)
8. Non-contact electric field sensing (NCV):
- enables acoustic detection of live conductors using a buzzer and optical detection using an LED
Other parameters:
- jaw opening: 28mm
- measurement of maximum and minimum values: yes
- yes
- Yes, data hold, low battery indication (H/>>- and low data: battery voltage is less than 2.4 V; if the battery voltage is less than approx. 2.2 V, the device cannot be switched on
- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.
- Drop resistance: yes, 1 m
- Electromagnetic compatibility: RF ≤ 1 V/m, general accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified
- Operating altitude: ≤ 2000m and operating humidity <3000m
-: (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
- storage temperature and humidity: -20 to +60°C (≤ 80%RH)
- recommended calibration interval: 1 year
- 1-battery power supply: 5 V–2 V (R03)
- product dimensions: 201.5 × 47 × 28.5 mm
- Weight: approx. 241 g (including batteries);
- product colour: red and grey
Package contents:
- UT202BT clamp multimeter: 1 pc
- test leads: 1 pair
- temperature probe (K): 1 pc
- 2 x R03 instruction manuals
- User manual: 1 copy
Manufacturer: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT202F Clamp Meter
This product comes with a 3-year warranty. The UT202F digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 600A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and high-voltage frequency up to 600 V
- non-contact electric field detection (NCV)
- Frequency measurement from 10 MHz to 600 V
60mF
- Measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600V in ranges
- automatic range switching
- accuracy of current and voltage measurements guaranteed within 1% of the technical
parameters:
1. AC current measurement (ranges / resolution / accuracy):
6,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% + 10)
60.00A / 0.010A / 50Hz ~ 100Hz ± 10.0%
(2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10)
- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620A.>
AC voltage measurement (range / resolution / accuracy):
6,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5)
60.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% / 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5)
- frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz overload protection at the input
-0.01kHz overload
-0. approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
600.0 mV / 0.100 mV / ± (0.7% + 3)
6,000 V / 0.001 V / ± (0.5% + 2)
60.00 V / 0.010 V / ±0.7% 3)
600.0 V / 0.100 V / ± (0.7% + 3)
- input impedance approx. 10 MΩ
- overload protection at 600 Vrms
4. Resistance measurement (range / resolution / accuracy):
600.0Ω / 0.1Ω / ± (1.0% + 2)
6,000 kΩ / 0.001 kΩ / ± (0.8% + 2)
60.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2)
600.0 kΩ / 0.1 kΩ / ± (0.8% + 2)
6,000 MΩ / 0.001 MΩ / ± (2.0% + 5)
60.00 MΩ / 0.01 MΩ / ± (2.0% + 5) overload protection at 6.0% + 5)
-50 Vrms
5. Capacitance measurement (ranges / resolution / accuracy):
6,000 nF / 0.001 nF / ± (4.0% + 10)
60.00 nF / 0.01 nF / ± (4.0% + 10)
600.0 nF / 0.00% + 1.10)
6,000 μF / 0.001 μF / ± (4.0% + 5)
60.00 μF / 0.01 μF / ± (4.0% + 5)
600.0μF / 0.1μF / ± (4.0% + 5)
600.0μF / 0.1μF / ± (4.0% + 5). ± 10.0%
60.00 mF / 0.01 mF / ± 10.0%
- overload protection at 600 Vrms
6. Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
Duty cycle: 0.1 to 99.9% / 0.1% / ± 5.0% / ± 5.0% Measurement sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
>1 V RMS input
> 1 V RMS: amplitude ≤ 30 V RMS
- Note 2) Duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95% Duty cycle: 30.0% ~ 70.0%
- Overload protection at 600 V rms
7. Circuit continuity check:
- if the measured resistance is less than 10Ω, the continuity circuit signal triggers a buzzer
- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
60-0Ω during overload
Vrms
8. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.9V
- measurement range of 6.000V
Parameters:
- measurement of maximum and minimum values: yes
- Relative mode (ratio) measurement for voltage and capacitance: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- 1.5 V battery power supply (backlit display size: 3 x 3): 25 mm
- Product dimensions: 215 mm x 63 mm x 36 mm
- net product weight: 248 g
- Product colour: red and grey
Package contents:
- UT201R clamp multimeter: 1 pc. test leads
/>- 1 pc. (R03): 2 pcs
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight per box: 16/F: 7 kg
https://www.uni-trend
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT202R Digital Clamp Meter
This product comes with a 3-year warranty. The UT202R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- non-contact electric field detection (NCV)
- Temperature measurement from -1/>-°C to -100°C, multi-segment display and audible/visual alarm
- protection against voltages exceeding 600 V in intervals
- automatic range switching
- accuracy guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
4,000 A / 0.001 A / 50 Hz ~ 100 Hz ± (4.0% + 10)
40.00A / 0.010A / 50Hz ~ 100Hz ± 2.0%/100Hz ± (4.0% +10) 0.100 A / 50 Hz ~ 100 Hz ± (2.0% +10)
- the frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 420 A
>
AC voltage measurement (range / resolution / accuracy):
4,000 V / 0.001 V / 10 Hz to 10 kHz ± (1.0% + 5)
40.00 V / 0.010 V / 10 Hz ~ 10 kHz ± (0.8% / 0.8% +5) / 10 Hz ~ 10 kHz ± (0.8% +5)
600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to ± 10 kHz at a resolution of + (10 kHz). 0.01 Hz to 0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% +3)
4.000 V / 0.001 V / ± (0.5% +2)
40.00 V / 0.010 V / 0.010 V / 0.010 V / ± (0.7% +3) 0.100 V / ± (0.7% +3)
600 V / 1,000 V / ± (0.7% +3)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
4. Resistance measurement (ranges / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000 kΩ / 0.001 kΩ / ± (0.8% +2)
40.00 kΩ / 0.01 kΩ / 0.01 kΩ / ±40.8 kΩ / ±2.0 kΩ / 0.1 kΩ / ± (0.8% +2)
4,000 MΩ / 0.001 MΩ / ± (2.0% +5)
40.00 MΩ / 0.01 MΩ / ± (2.0% +5)
- overload protection at 600 Vrms
>
Capacitance measurement (ranges / resolution / accuracy):
4,000 nF / 0.001 nF / ± (4.0% +10)
40.00 nF / 0.01 nF / ± (4.0% +10)
400.0 nF / ±4 nF / ±4 nF / ±4 nF (0.01 nF / ± (4.0% +10) +10)
4,000 μF / 0.001 μF / ± (4.0% +5)
40.00 μF / 0.01 μF / ± (4.0% +5)
400.0 μF / 0.1 μF / ± (4.0% +5.0,01 μF / 0.01 μF / ± (4.0% +5)) 10.0%
- overload protection at 600 Vrms
6. Temperature measurement (ranges / resolution / accuracy):
-40°C to +40°C/1°C / ±4°C
+40°C to +500°C/1°C/ ±(1.5% +5)
+500°C to +1000°C/±(2°C/1°C/±(1.5% +5) +5)
-40°F to +104°F/1°F/± 6°F
+104°F to +932°F/1°F/ ± (2.0 +6)
+932°F to +1832°F/1°F/ ± (2.5% +4/7)
Circuit continuity check:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31 ohms, the open circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
06 overload
-0Ω Vrms
8. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 2.2V
- measurement in the 4.900 V range
/>
Non-contact electric field sensor (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz
Other parameters:
Measurement value:
HOLD: Yes
- low battery indication: Yes
- Auto-off: Yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 215 mm x 63 mm x 36 mm
- Net product weight:
- 24 g Product colour:24-8 g grey
Package contents:
- UT202R clamp multimeter: 1 pc Box: 40 pcs
- Standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 17.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT202T is an easy-to-use smart clamp multimeter that can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values.
Capacitance measurement and non-contact voltage measurement (NCV) are selected by pressing buttons. The UT202T features a new design, high reliability and safety, as well as automatic range switching available for all functions. Dual backlit LCD screen, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, current/frequency. There is an LED lamp on the underside of the test leads. It is powered by two 1.5V AAA R03 batteries.
The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree. :
- measurement of AC/DC voltage, AC current, resistance, capacitance and circuit continuity
- measurement of voltage and current frequency on the auxiliary display
- Non-contact voltage detection (NCV)
- dual LCD display with multi-segment backlight
- Audible and visual alarm
- protection against voltage ranges exceeding 60 V
- switching
- accuracy guaranteed between 5% and 100% of the range
- built-in LED torch
- powered by two 1.5V AAA R03 batteries
Technical specifications:
To ensure measurement accuracy, the operating temperature must be within the range of 18°C to 28°C
1. AC current measurement (ranges/resolution/accuracy):
9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60)
- minimum detectable current: 0.01A
- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
- overload protection
/>
/200 Hz
AC voltage measurement (range / resolution / accuracy):
9.999 V / 0.001 V / 40 Hz to 400 Hz ±(0.8%+3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8% + 3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3)
- Frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude ≥5Vrms at a frequency from 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.
- Input impedance approx. 10 MΩ
- Overload protection at 600 Vrms
- Minimum detectable voltage 0.6 V
3. DC voltage measurement (range / resolution / accuracy):
9.999 V / 0.001 V / ±(0.5%+3)
99.99 V / 0.01 V / ±(0.5% + 3)
600 V / 0.1 V / ±(0.5% + 3) input
approx. 10 MΩ
- overload protection at 600Vrms
- minimum detectable voltage 0.6V
4. Resistance measurement (ranges/resolution/accuracy):
999.9Ω / 0.1Ω / ±(0.8%+3)
9.999 kΩ / 0.001 kΩ / ±(0.8% + 3)
99.99 kΩ / 0.01 kΩ / 0.01 kΩ / %+90 kΩ / %+90 kΩ / >±9 kΩ / 0.1 kΩ / ±(0.8%+3)
6,000 MΩ / 0.001 MΩ / ±(1.5%+3)
- overload protection at 600 Vrms
- open-circuit voltage approx. 1 V
5. Capacitance measurement (ranges/resolution/accuracy):
99.99 nF / 0.01 nF / ±(4.0%+10)
999.9 nF / 0.1 nF / ±(4.0%+10)
9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5)
99.99 μF / 0.01 μF / ±(4.0% + 5)
999.9 μF / 0.1 μF / ±(4.0% + 5)
9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10)
- overload protection at 600 Vrms
6. Checking circuit continuity:
- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
- open-circuit voltage approximately 3.0 V
- Overload protection at 600 Vrms
7. Non-contact electric field sensing (NCV):
- enables acoustic detection of live conductors using a buzzer and visual detection using an LED
Other parameters:
- jaw opening: 28 mm
- measurement of maximum and minimum values: yes
-: data hold indication
- low battery
- yes, if the battery voltage is less than 2.4V; if the battery voltage is less than approx. 2.2V, the device cannot be switched on
- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.
- Drop resistance: yes, 1 m
- Electromagnetic compatibility: RF ≤ 1 V/m, overall accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified
- Operating altitude: ≤2000m, operating temperature and humidity: +3/0°C
-0°C (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
- storage temperature and humidity: -20 to +60°C (≤ 80%RH)
- recommended calibration interval: 1 year
- 1-battery power supply: 5 V–2 V (R03)
- Product dimensions: 201.5 × 47 × 28.5 mm
- UT202T weight: approx. 241g (including batteries);
- Product colour: red and grey
Package contents:
- UT202T multimeter clip: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 2 pcs
- user manual
- pcs
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard carton dimensions: 485 x 295 x 385 mm
- standard gross weight of carton: approx. 17 kg
Manufacturer:
UNI-TREND
-
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT203R Clamp Multimeter
This product comes with a 3-year warranty. The UT203R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 400A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- measurement of frequencies from 10 Hz to 10 MHz
- Measurement capabilities
-400V
- 40 mF
- measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600V in intervals
- non-contact detection of live conductors
- automatic range switching
- measurement accuracy of current and voltage is guaranteed to within 1% across 10% of ranges
Technical parameters:
1. AC measurement (ranges / resolution / accuracy):
40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5)
400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) current monitoring accuracy ± 5) the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620 A
2. DC current measurement (ranges / resolution / accuracy):
40.00A / 0.010A / ± (2.0% +5)
400.0 A / 0.100 A / ± (2.0% + 5)
- overload protection at 620 A
>
>
4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.8% +5) / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10Hz to 60kHz at a resolution of ±0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
4. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% +3)
4.000 V / 0.001 V / ± (0.5% +2)
40.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2)
600.0V / 1V / ± (0.5% +2)
- input impedance approx. 10MΩ
- Overload protection at 600 Vrms
5. Resistance measurement (ranges / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000 kΩ / 0.001 kΩ / ± (0.8% +2)
40.00kΩ / 0.01kΩ / 0.01kΩ / ±2.0% 0.8kΩ / ±2.0kΩ / 0.1kΩ / ± (0.8% +2)
4.000 MΩ / 0.001 MΩ / ± (2.5% +5)
40.00 MΩ / 0.01 MΩ / ± (2.5% +5)
- overload protection at 600 Vrms open circuit
- approx. 1V
6. Capacitance measurement (range / resolution / accuracy):
40.00 nF / 0.01 nF / ± (4.0% +5)
400.0 nF / 0.1 nF / ± (4.0% +5)
4.000 μF / 0.001 μF / ± (4.0% +5)
40.00 μF / 0.01 μF / ± (4.0% +5)
400.0 μF / 0.1 μF / ± (4.0% +5)
4,000 μF / 0.001 μF / ± 10.0%
- overload protection at 600 Vrms
7. Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
Duty cycle: 0.1 to 99.9% / 0.1% / ± (5)
Note/+5. Sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
> 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS
- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency
Operating frequency
1 kHz 30.0% ~ 70.0%
- overload protection at 600 Vrms
8. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31Ω, the open circuit signal does not emit a buzzer
- uncertainty in the range from 10Ω to 31Ω. 600Ω range
- Overload protection at 600 Vrms
9. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 4.0V
- measurement in the range of 6.000V
Non-contact voltage detection (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz
Other parameters:
- Measurement of maximum and minimum values (ratio) for voltage and capacitance: yes
- HOLD: yes
- low battery indicator: yes
- Auto-off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 63 mm
- x 63 mm
- net product weight: 235 g
- product colour: red and grey
Package contents:
- UT204R clamp multimeter: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 2 pcs user manual
- 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 16.1 kg
MANUFACTURED BY UNIVERSITATEA www.
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT204R Clamp Multimeter
This product comes with a 3-year warranty. The UT204R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on low-voltage distribution lines in CAT II. With the included Type K thermocouple (nickel-chromium-nickel-silicon temperature sensor), it allows temperature measurement from -40°C to 1000°C. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is <11μA, which effectively extends the battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and high-voltage frequency up to 600 V
- frequency measurement from 10 Hz to 10 MHz
- Measurement capabilities
- 60 mF
- Temperature measurement from -40 to +1000 °C
- Measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600 V in intervals
- Non-contact detection of live voltages and switching accuracy of live conductors
-
guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5)
600.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) The accuracy of AC frequency monitoring in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620 A
2. DC current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / ± (2.0% + 5)
600.0 A / 0.100 A / ± (2.0% + 5)
- overload protection at 620 A
>
>
6,000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
60.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.0% +5) / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to 60 kHz ± (0.5% + 2) at a resolution of 0.01 Hz to 0.01 kHz
- input overload protection
- 0.01 kHz
- overload protection
- 60/0 V rm. 10 MΩ
4. DC voltage measurement (range / resolution / accuracy):
600.0 mV / 0.100 mV / ± (0.7% +3)
6,000 V / 0.001 V / ± (0.5% +2)
60.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
5. Resistance measurement (ranges / resolution / accuracy):
600.0Ω / 0.1Ω / ± (1.0% +2)
6,000 kΩ / 0.001 kΩ / ± (0.8% +2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / 60.8 kΩ ±2.0 kΩ 0.1 kΩ / ± (0.8% +2)
6,000 MΩ / 0.001 MΩ / ± (2.5% +5)
60.00 MΩ / 0.01 MΩ / ± (2.5% +5)
- overload protection at 600 Vrms open circuit
- approx. 1V
6. Capacitance measurement (ranges / resolution / accuracy):
60.00 nF / 0.01 nF / ± (4.0% +5)
600.0 nF / 0.1 nF / ± (4.0% +5)
6000 μF / 0.001 μF / ±4.0% +5)
60.00 μF / 0.01 μF / ± (4.0% +5)
600.0 μF / 0.1 μF / ± (4.0% +5)
6,000 mF / 0.001 mF / ± 10.0%
- overload protection at 600 Vrms
7. Temperature measurement (ranges / resolution / accuracy):
-40°C to +40°C / 1°C / ± 4°C
+40°C to +500°C/1°C / ± (1.5% +5)
+500°C to +1000°C/±2°C/1.5°C
-40°F to +104°F / 1°F / ± 6°F
+104°F to +932°F / 1°F / ± (2.0 +6)
+932°F to +1832°F / 1°F / ± 4
%
Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% +4)
load: 0.1 to 99.9% / 0.1% / ±5)
Note/+5. Sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
> 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS
- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency
Operating frequency
1 kHz 30.0% ~ 70.0%
- Overload protection at 600 Vrms
9. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31Ω, the open-circuit signal does not emit a buzzer
- uncertainty in the range from 10Ω to 31Ω. 600Ω range
- Overload protection at 600 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 4.0V
- measurement in the range of 6.000V
Non-contact electric field sensing (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz
Other parameters:
- measurement of maximum and minimum values
- relative measurement of maximum and minimum. Mode (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 631.5 mm x 631 mm
- net product weight: 235 g
- Product colour: red and grey
Package contents:
- UT204R clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 101 V: 0 pcs
(R03): 2 pcs
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight per box: 16/F: 7 kg
https://www.uni-trend.com/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT205E Clamp Multimeter
This product comes with a 3-year warranty. The UT205E digital clamp meter is used for measuring AC and DC voltages up to 1000 V, AC currents up to 1000 A and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum displayable value is 6000. The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive inductive current loop. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends the battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and AC current, resistance, diodes, continuity, capacitance
- automatic polarity display
- current frequency measurement in the range from 40 to 60 Hz and up to low voltages (10 Hz) V0040 at 400 Hz
- Measurement of low-voltage frequency (mn) in the range from 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- Measurement of the (relative) ratio of voltages and capacitances
- Multi-segment display and audible/visual protection against voltages exceeding 100 V - Intervals
- NCV function – non-contact detection of live conductors
- Frequency/duty cycle measurement function
- Choice of automatic or manual range switching
- Built-in lamp
- Accuracy of current and voltage measurement is guaranteed when using the range within the 5% to 100% range; no adjustment of the 5% to 100% range is required
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 60Hz is ± (0.1% + 3) at a resolution of 0.1Hz
- Overload protection at 1000A
2. AC voltage measurement (range / resolution / accuracy):
6,000 V / 0.001 V / 40 Hz ~ 400 Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
3. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5% + 3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5% + 3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
4. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
5. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
6. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
7. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6.000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
8. Frequency measurement and duty cycle (duty)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
duty cycle: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
9. Non-contact electric field sensor (NCV):
- enables the detection of live wires - as the detected voltage increases, the buzzer will sound at a higher volume and the LED will begin to flash.
Other parameters:
- measurement of maximum and minimum values: yes
relative capacitance measurement mode: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- Powered by 1.5 V batteries (R03): 2 pcs
- backlit display size: 43 x 45 mm
- Product dimensions: 272 x 81 x 43.5 mm
- Net product weight
- 43.5 mm
colour: red and grey
Package contents:
- UT205E clamp multimeter: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 3 pcs
- user manual: 1 pc
>
Standard box packaging: 10 pcs
- standard box dimensions: 355 mm x 330 mm x 315 mm
- standard gross weight of box: 7.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT206B Clamp Multimeter
This product comes with a 3-year warranty. The UT206B digital clamp meter is used to measure AC and DC voltages up to 1000 V, AC currents up to 1000 A, and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive inductive current loop. Option to purchase a flexible loop for measuring currents up to 3000 A. Power supply: 3 x 1.5 V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and AC current, resistance, diodes, continuity, capacitance
- automatic polarity display
- measurement of frequency of low-voltage (LV) currents and voltages up to 1000–40 V/Hz
measurement of low-voltage (LV) frequency in the range 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- temperature measurement from -40 to +1000 °C with a closed K-type thermocouple
- Measurement of the (relative) ratio of voltages and capacitances for alarm and multiple alarms – e.g. protection against voltages exceeding 1000 V in intervals
- NCV function – non-contact detection of live conductors
- LoZ V function – measurement with low input impedance (approx. 2 kΩ) of the device
- INRUSH function – measurement of transients up to 100 ms – with an additional start-up duration of up to 30,000 A. loop
- LPF ACV function – AC voltage measurement with low-pass filter (approx. 2.5 kHz) on inverters and variable-frequency drives
- Frequency/duty cycle measurement function
- Choice between automatic or manual switching
- Built-in lamp
- Current and voltage accuracy are guaranteed when current and voltage measurement is within 10% of the value; if the value falls outside this range, the range must be changed
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz
- Overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.000Hz / 40.010Hz ±(10.0%+10)
300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection
-10 3000A
3. AC voltage measurement (range / resolution / accuracy):
6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3)
60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
4. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ
5. AC LPF V (measurement with low input impedance approx. 2 kΩ)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
- Input overload protection rm approx. 2kΩ
6. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5%+3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
7. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
8. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
9. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0 V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
10. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6,000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
11. Temperature measurement
(ranges / resolution / accuracy):
-40°C to +300°C / 0.1°C / ± 1.0°C+20
+300°C to +1000°C / 1°C / ±(1.0%+2)
+573°F to +1832°F / 1°F / ±(1.0%+4)
12. Frequency measurement and operating cycle (filling)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
Fill: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
13. Non-contact electric field sensing (NCV):
- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- Auto power off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 43 x 45 mm
- Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 492g
- Product colour: red and grey
Package contents:
- UT206B clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 1000°C: 1 pc
3:
>-R<03/> user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 10 pcs
- standard box dimensions: 355 mm x 330 mm x 315 mm
- standard gross weight per box: 7.1 kg
MANUF UNI-TREND
https://www.uni-trend.com/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT207B Clamp Meter
This product comes with a 3-year warranty. The UT207B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 10,000,000 V in the range of 1,000,000 V at 400 Hz and low voltage (LV) from 10 Hz to 1 MHz. It features protection against voltages exceeding 1,000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance
- automatic polarity display
- measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range from 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- Measurement of the (relative) ratio of voltages and capacitances
- Multi-segment display and audible/visual alarm
- protection against voltages higher than 10V/0V - contact function without NC
- live conductors
- LoZ V function ~ measurement with low input impedance (approx. 2kΩ) of the device
- INRUSH function – measurement of transients up to 100 ms in length – inrush current at device start-up up to 3000 A with additional flexible loop
- LPF ACV measurement function on nf2H5 filter (approx. inverters and variable frequency drives
- Frequency/duty cycle measurement function
- Choice between automatic or manual range switching
- Built-in lamp
- Accuracy of current and voltage measurement is guaranteed when using the range between 5% and 100% of the full scale; at 5% of the full scale, a technical adjustment is required
>
Parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz
- Overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.000Hz / 40.010Hz ±(10.0%+10)
300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection
-10 3000A
3. DC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / ±(2.0%+5)
600.0A / 0.100A / ±(2.0%+5)
1000.0A / 1A / ±(2.0%+5) overload protection
2.0%/>-5 1000A
4. AC voltage measurement (range / resolution / accuracy):
6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3)
60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ
6. AC LPF V (measurement with low input impedance approx. 2 kΩ)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
- Input overload protection rm approx. 2kΩ
7. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5%+3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
8. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
9. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
11. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6,000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
12. Frequency measurement and duty cycle (duty)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
duty cycle: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
13. Non-contact electric field sensing (NCV):
- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- Auto power off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 43 x 45 mm
- Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g
- Product colour: red and grey
Package contents:
- UT207B multimeter clip: 1 pc
- Test leads: 1 pair
- 1.5 V battery (R03): 3 pcs
- user manual
- 1 pc
- user manual
Packaging:
- standard quantity per box: 10 pcs
- standard box dimensions: 355 mm x 330 mm x 315 mm
- standard gross weight per box: 7.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT208B Clamp Multimeter
This product comes with a 3-year warranty. The UT208B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 100000000000V at 400Hz and low voltage (mn) 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows LV distribution measurements in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance
- automatic polarity display
- Measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- Temperature measurement from -40 to +1000 °C with a closed K-type thermocouple
- measurement of the (relative) ratio of voltages and voltages and capacitances
multiple visual protection voltages greater than 1000 V in ranges
- NCV function – non-contact detection of live conductors
- LoZ V function ~ measurement with low input impedance (approx. 2 kΩ) of the device
- INRUSH function – measurement of transients up to 100 ms – inrush current on device start-up with an additional 3,000,000 loop at the LPF ACV function – AC voltage measurement with an NF filter (approx. 2.5 kHz) on inverters and variable-frequency drives
- Frequency/duty cycle measurement function
- Choice between automatic or manual switching
- Built-in lamp
- Accuracy of current and voltage measurement is guaranteed when using the range from 10% to 10%; within 5% of this range, it is necessary to change the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz
- Overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.000Hz / 40.010Hz ±(10.0%+10)
300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection
-10 3000A
3. DC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / ±(2.0%+5)
600.0A / 0.100A / ±(2.0%+5)
1000.0A / 1A / ±(2.0%+5) overload protection
2.0%/>-5 1000A
4. AC voltage measurement (range / resolution / accuracy):
6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3)
60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ
6. AC LPF V (measurement with low input impedance approx. 2 kΩ)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
- Input overload protection rm approx. 2kΩ
7. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5%+3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
8. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
9. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
11. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6,000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
12. Temperature measurement
(ranges / resolution / accuracy):
-40°C to +300°C / 0.1°C / ± 1.0°C+20
+300°C to +1000°C / 1°C / ±(1.0%+2)
+573°F to +1832°F / 1°F / ±(1.0%+4)
13. Frequency measurement and operating cycle (filling)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
Fill: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
14. Non-contact electric field sensing (NCV):
- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will start flashing. (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- Auto power off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 43 x 45 mm
- Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g
- Product colour: red and grey
Package contents:
- UT208B clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 1000°C: 1 pc
3:
>- (battery
3): user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 5 pcs
- standard box dimensions: 355 mm x 330 mm x 165 mm
- standard gross weight per box: 4.5 kg
UNI-TREND MANUFACTURE
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210A Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210A Mini Clamp
* small AC clamp
* sensitive
* input protection
SPECIFICATIONS
2 AC current/A20A0
±(1.0%+9)
FEATURES
Display range 2000
Jaw capacity 17mm
Data hold
LCD backlight
Auto power off
Low battery indicator
Input protection
TOTAL POWER
TOTAL POWER: (2x)
LCD size: 39.3 x 26.5 mm
Weight: 160g
Dimensions: 155x60x33.5mm
ACCESSORIES
Battery, manual
MANUFACTURER: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210B Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210B Mini Clamp
* small AC clamp
* sensitive
* input protection
* TRMS
* NCV/ACTION
ACTION
Current
2A/20A/200A ±(1.0%+9)
FEATURES
Display range 2000
TRMS
NCV
MAX/MIN
Relative mode
Jaw capacity 17mm
Data Hold
Auto stop
Auto shut-off
LCD Battery indicator
Input protection
GENERAL FEATURES
Power: 1.5V AAA (2x)
LCD size: 39.3 x 26.5 mm
Weight: 160g
Dimensions: 155 x 60 x 33.5 mm,
Battery
/
Battery Manual
MANUFACTURER: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210C Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210C Clamp Meter
TECHNICAL SPECIFICATIONS
AC Current (A) 2A/20A/200A
20A+/200A ±/200A ±/200A
Voltage (V) 2V/20V/200V/600V ±(1.0%+3)
DC Voltage (V) 200mV/2V/20V/200V/600V ±(0.7%+3)
Resistance (Ω) 200Ω/2kΩ/M20kΩ/20kΩ/M200Ω/20kΩ ±(1.0%+2)
Capacitance (F) 20nF/200nF/2μF
/20μF/200μF/2mF/20mF ±(4%+5)
Temperature (℃) -40~1000℃) ±(1℉/+3)
Temperature -40~1832℉ ±(1.5%+5)
FEATURES
Display count 2000
Auto range √
Jaw capacity 17mm
True RMS />V />√ √ A.
NCV √
Auto shut-off: Approx. 15 minutes √
Continuity buzzer √
Low battery indication ≤2.5V √
Data hold √
MAX mode/√ /√ Relative
√
LCD backlight √
Input protection √
Input impedance for DCV ≥10MΩ √
GENERAL SPECIFICATIONS
Power supply: 2 x 1.5V AAA batteries
Net product dimensions LCD 329.3mm> Weight 170 g
Product dimensions 175 mm x 60 mm x 33.5 mm
ACCESSORIES
Battery, test lead, contact-point temperature probe
MANUFACTURER
UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210D Clamp Meter
This product comes with a 3-year warranty. UT210D Clamp Meter
The UT210 series mini clamp meters are designed to perform well in confined spaces. They are essential tools for the maintenance of mechanical and electrical equipment, the installation of household appliances and electrical work.
1. NCV
2. Ergonomic and lightweight
3. Automatic range, sampling rate of 2–3 times per second
4. True RMS
5. ZERO mode
6. LCD backlight, data hold
7. Auto power off, low battery indicator
Specifications: Range
AC current (A): 200A ±(2.5%+8)
DC current (A): 200A ±(2%+3)
AC voltage (V): 600V ±(1%+3)
DC voltage (V/>60)
±(0.7%+3)
Resistance (Ω): 20MΩ ±(1%+2)
Frequency (Hz): 60kHz ±(0.1%+4)
Capacitance (F): 20mF ±(4%+5)
Temperature:
±0°C ±0%+4)
-40~1832℉ ±(1.5%+5)
Features:
Display count: 2000
Continuity buzzer √
Automatic range √
Jaw opening />170 mm
17 mm
General features:
Power: 1.5V battery (R03) x 2
Display: 39.3 mm x 26.5 mm
Product colour: red and grey
Net product weight: 170g
Product dimensions: 175mm x 3.5mm x 3.5mm x 3.5mm Accessories: batteries, test leads, spot contact temperature probe
Standard individual packaging: gift box, English manual, carrying case
Standard quantity per box: 40 pcs
www.uni-trend.com
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210E Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210E – small clamp multimeter
SPECIFICATIONS
AC currents
2A/20A/100A ±(2.5%+5A0)A0
A0
A0 ±(2.5%+3)
AC voltage
2V/20V/200V/600V ±(1%+3)
Direct voltage ±(0.7%+3)
Resistance
200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200kΩ/2MΩ ±(1%+2)
Capacitance
2nF/20nF/200nF/2μF/20μF/200μF/2mF/20mF ±(4%+5)
FUNCTIONS
Display count 2000
J Auto open
17 mm
TRMS
Diode test
NCV
Data hold
Zero mode
Display backlight
Auto power off
Continuity buzzer
Low battery indicator
Input protection
Input impedance DCV/GENERAL+10MΩ/GENERAL> FEATURES
Power: 2x1.5V AAA batteries
Weight: 170g
Dimensions: 175x60x33mm
LCD size: 39x26mm