Products

1139 products

  • Last stock! UNI-T UT18E Voltage Tester UNI-T UT18E Voltage Tester

    UNI-T UT18E Voltage Tester

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. UNI-T UT18E tester. The UT18 series tester is designed to test AC/DC voltage (up to 1000V), three-phase voltage, phase sequence, continuity and much more. This series is CAT IV 600V rated and meets the IP65 protection standard. The voltage tester is designed to make life easier for electricians, technicians and other professionals working with electricity in all environments. It is equipped with several useful functions for voltage identification. It has an automatic mode that detects AC or DC voltage and signals the presence of voltage via an audible and visual warning. Product specifications: - 8 voltage levels: 12V, 24V, 50V, 120V, 230V, 400V, 400V, 1/900V, 1/900V sequence test - automatic polarity test - RCD function - residual current device test - automatic shut-off - Frequency measurement - low impedance measurement - Simultaneous LED and LCD display - Audible alarm - built-in LED torch - CAT III 1000V / CAT III 10 600V Technical specifications: - voltage (AC/DC) 6V ±(1.5% + 1) 12V ±(1.5% + 2) 24V ±(1.5% + 2) 50V ±(1.5% + 1) 50V ±(1.5% + 4) 230V ±(1.5% + 5) 400V ±(1.5% + 5) 690V ±(1.5% + 5) 1000V ±(1.5% + 5) phase rotation test 1.5% + 5) -0 V AC, ~ 4–0 V AC 50 Hz–60 Hz - continuity test - audible and visual LED indication - residual current device test 230V (50-400Hz) - polarity detection - automatic range: full range - 1100V surge protection - automatic standby current<br/1:0; full range - Low battery indication: approx. 2.4 V - LCD display (voltage): 6V–1000V - LCD display (frequency): 40Hz–400Hz ±(3%+5) - IP65 protection - CAT III 1000V; CAT IV 600V - Product colour: red, black - Power supply: 2 x 1.5V AAA LR03 batteries - Product weight (including batteries): 277g - product dimensions: 272 x 85 x 31 mm - Standard quantity per cardboard box: standard dimensions: 4 pcs. 380 x 365 mm Manufacturer: UNI-TREND

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €46,91

  • UNI-T UT191E PRO Line Multimeter

    UNI-T UT191E PRO Line Multimeter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT191E PRO Line Multimeter This product comes with a 3-year warranty. UT191E Professional Multimeter UT191 series professional multimeters designed for industrial users. The UT191’s new function memory retains the most recent mode setting at the next power-up, improving user efficiency. Applications: This series of CE/GS/cTUVus-certified multimeters complies with CAT III 600V and has an IP65 rating, suitable for use in damp and dusty environments. 1. Measurement setting saved after power reset 2. IP65, 2 m drop resistance 3. True RMS/peak value measurement 4. Automatic backlight 5. 20A current measurement 6. AC LoZ measurement Specifications: Range DC voltage (V): 600V ±(0.5%+3) AC voltage (V): 600V ±(0.7%+3) AC LoZ (V): 60+V ACV: 60+V 600V ±(2%+5) DC current (A): 20A ±(0.8%+3) AC current (A): 20A ±(1%+3) Resistance (Ω): 60MΩ ±(0.8%+2) Capacitance (F)(30%+mF): ±(30%+3) (Hz): 10Hz~1MHz ±(0.1%+4) Duty cycle: 0.1%~99.9% ±(2%+5) ACV peak hold ±(2%+100) Peak current detection ±(3%+100) Display : 6000-digit display Sampling rate: 3 times/second Analogue bar graph: 31-segment graph True RMS: √ AC voltage frequency response 45Hz–400Hz AC current frequency response: 45Hz~400Hz DC diode test:/>Continuity/DC range:/> √ Auto power off: √ Low battery indication: √ Data hold/MAX/MIN: √ Function selection (SELECT): √ Flashlight/Auto light: √ 2 m drop test/IP65: √ General: √ General: Power: 9V battery LCD size: 58mm x 42mm Net product weight: 428g Product colour: red and grey Product dimensions: 180mm x 87mm x 59mm Standard accessories: test lead, battery, carrying case, individual gift box Standard quantity per box: 10 pcs. Standard box dimensions: 545mm x 315mm x 335mm Standard box gross weight: 8.8kg Manufacturer: UNI-TREND

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €79,61

  • UNI-T UT191T PRO Line Multimeter

    UNI-T UT191T PRO Line Multimeter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT191T PRO Line Multimeter This product comes with a 3-year warranty. UT191T Professional Multimeter UT191 series professional multimeters designed for industrial users. The UT191’s new function memory retains the most recent mode setting at the next power-up, improving user efficiency. The UT191T supports accurate and precise temperature measurement. Applications: This series of CE/GS/cTUVus-certified multimeters complies with CAT III 600V and has an IP65 rating, making it suitable for use in damp and dusty environments. 1. Measurement settings are saved after a power reset 2. IP65, 2 m drop resistance 3. True RMS/peak value measurement 4. Automatic backlight 5. 20A current measurement 6. AC LoZ measurement 7. Precise temperature measurement with 0.1 ℃ resolution Specifications: Range DC voltage (V): 600V ±(0.5%+3) AC voltage (V): 600V ±(0.7%+3) Local. ACV LPF: 600V ±(2%+5) DC current (A): 20A ±(0.8%+3) AC current (A): 20A ±(1%+3) Resistance (Ω): 60MΩ ±(0.8%+2) Frequency (Hz): 10Hz~1MHz ±(0.1%+4) Frequency (Hz): 10Hz~1MHz ±(0.1%+4) Duty cycle: 0.1%~99.9% ±(2%+5) Temperature (℃): -40℃~400℃ (0.1°C resolution) ± 0.1°C: +20)(temperature ACV peak hold ±(2%+100) Peak current detection ±(3%+100) Features: Display rate: 600 times/sec. Bar graph: 31 sections True RMS: √ Frequency response for AC voltage 45Hz~400Hz Frequency response for AC current 45Hz~400Hz Diode/continuity test: √ Auto/manual range: √ Auto power-off />Battery auto-shutdown indicator: √ √ Data hold/MAX/MIN: √ Function selection (SELECT): √ Flashlight/Auto backlight: √ 2 m drop test/IP65: √ General features: Power: 9V battery size: 8mm x 4mm Net product weight: 428g Product colour: red and grey Product dimensions: 180mm x 87mm x 59mm Standard accessories: test lead, battery, carrying case, contact-type temperature probe Standard individual packaging: Gift box, English manual Standard quantity per box: 10 pcs. 545 mm x 315 mm x 335 mm Standard gross weight per box: 8.8 kg Manufacturer: UNI-TREND

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €91,81

  • UNI-T UT195DS PRO Line Multimeter UNI-T UT195DS PRO Line Multimeter

    UNI-T UT195DS PRO Line Multimeter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT195DS PRO Line Multimeter This product comes with a 3-year warranty. UNI-T UT195DS PRO Line Multimeter Product specifications and features: - display count: 6000 - Display interface (HTN): dual measurement/digit conversion speed 5 - Analogue bar conversion rate: times/s²0 - Analogue bar: 31 sections - True RMS - AC voltage frequency response: 45 - 5 kHz - AC current frequency response: 45–5 kHz - Low-pass filter attenuation test: 3 - Diode/continuity test: 3V - Auto/manual range - Auto shut-off - Continuity buzzer - low battery indicator - data hold - MAX/MIN - function selection - operating temperature of electric torch -°C -0 °C °C - 2 m drop resistance - Protection rating: IP65 Technical parameters: - DC voltage: 600 mV – 1000 V ±(0.5%+3) - AC+DC: 6,000 V ±(600 V ±) - DC voltage: 600 mV – 1000 V 600 mV – 750 V ±(0.7%+3) - ACV LoZ: 600.0V ± (2.0%+3) - DC current (A): 600.0μA - 20A ±(0.8%+3) - AC current (A): 600.0μA – 600.0μA ±(1.0%+3) - Resistance (Ω): 600.0Ω – 60.00MΩ ±(0.8%+2) - Capacitance: 6.000 nF – 60.00 μF ±(3%+5) - Frequency: 60.00% - 1z+4.00 MHz > -0.00 MHz ±0.000 mF Duty cycle: 0.1% - 99.9% ±(2.0%+5) - peak hold: 250 μs - Power supply: 9V 6F22 carbon-zinc or 6LR61 alkaline battery - LCD size: 66 mm × 51 mm - Device dimensions: 5 mm - Device weight: - 3 g Accessories: - Test probes - battery - carrying case - manual Manufacturer: UNI-TREND

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €163,08

  • Last stock! UNI-T UT195E PRO Line Multimeter

    UNI-T UT195E PRO Line Multimeter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT195E PRO Line Multimeter This product comes with a 3-year warranty. UNI-T UT195E PRO Line Multimeter Product specifications and features: - maximum display range: 6000 - Display interface (HTN): single display - Measurement digit conversion rate: 3 times per second - Analogue bar conversion rate: 10 times/s - analogue bar: 31 sections - True RMS - low-pass filter test: 3 H/H attenuation) diode/continuity test: 3.5 V - Auto/manual range - Auto power off - continuity buzzer - low battery indicator - data hold - MAX/MIN - function selection - torch - automatic operating temperature - °C - automatic operating temperature -°C 2m drop resistance - protection rating: IP65 Technical parameters: - DC voltage: 600mV - 1000V ±(0.5%+3) - AC voltage: 600 mV – 750 V ±(0.7%:>+3 V AC +3) ±(2.0%+3) - DC current (A): 600.0 μA – 20 A ±(0.8% + 3) - AC current (A): 600.0 μA – 20 A ±(1.0% + 3) - Resistance (0.8%+3) - Capacitance (0.0%+3) - 600.0% ±0.0. Capacitance: 6.000 nF – 60.00 mF ±(3% + 5) - Frequency: 60.00 Hz – 10.00 MHz ±(0.1%+4) - duty cycle: 0.1% - 99.9% ±(2.0%+5) - Frequency response: -4 AC 400 Hz - AC current frequency response: 45 - 400 Hz - Power supply: 9V 6F22 carbon-zinc or 6LR61 alkaline battery - LCD size: 66mm × 51mm - Device weight: 473g - Device dimensions: 195 mm × 1995 mm × 58 mm Accessories: - Test probes - Battery - carrying case - manual Manufacturer: UNI-TREND

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €112,77

  • UNI-T UT195M PRO Line Multimeter UNI-T UT195M PRO Line Multimeter

    UNI-T UT195M PRO Line Multimeter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT195M PRO Line Multimeter This product comes with a 3-year warranty. UNI-T UT195M PRO Line Multimeter Product specifications and features: - display count: 6000 - Display interface (HTN): single conversion rate: measurements/digits - 3 - True RMS - AC voltage frequency response: 45 - 1kHz - AC current frequency response: 45 - 1kHz - low-pass filter test: (1kHz 3dB attenuation) - Diode/continuity test/auto-off/ power range - auto-off/ - continuity buzzer - low battery indicator - data hold - MAX/MIN - function selection - torch - automatic illumination - operating temperature: 0 °C - 40 °C - 2 m drop resistance - technical protection rating - - technical parameters: - DC voltage: 600 mV – 1000 V ± (0.5% + 3) - AC voltage: 600 mV – 750 V ± (0.7% + 3) - LoZ ACV: 600.0V ±(2.0%+3) current (2.0%>-3) DC -3.0. 20A ± (0.8%+3) - AC current (A): 600.0μA - 20A ± (1.0%+3) - resistance (Ω): 600.0Ω - 60.00MΩ ± (0.8%+2) - capacitance: -6.000 nF ±(3%+5) - frequency: 60.00 Hz – 40.00 MHz ± (0.1% + 4) - duty cycle: 0.1% - 99.9% - temperature: °C -40 - 1000°C ± (1.5%+4°C) - -2 temperature: °F -°/4°C (2.0%+5°F) - Power supply: 9V 6F22 carbon-zinc or 6LR61 alkaline battery - LCD size: 66 mm × 51 mm - Device colour: red and grey - Device weight: 473 g - Device dimensions: 195 mm × 95 mm × 58 mm Accessories: - Test probes - battery - carrying case - manual Manufacturer: UNI-TREND

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €137,93

  • UNI-T UT196 multimeter

    UNI-T UT196 multimeter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. The UT196 True RMS solar multimeter from UNI-T is a professional-grade product designed for professionals who install or maintain photovoltaic or wind power plants. The device’s design allows it to operate in harsh outdoor environments – it has IP65 protection and can withstand a drop from a height of 2 m. This multimeter measures DC voltage up to 1700 V and AC voltage (true RMS) up to 1500 V at a frequency range of 45 to 1000 Hz. With the optional UT-CS09D Flex current loop, it allows non-contact measurement of AC currents from 1.5 to 3000 A, even in confined spaces. In addition, the UT196 measures frequency, resistance, capacitance, semiconductor transitions and electrical circuit continuity. The low-pass function allows you to filter out RF interference generated by the inverter. The low-impedance mode can help with troubleshooting sensitive circuits, as well as circuits that may contain stray voltages. A built-in torch, a bright backlight, and audible and visual alarms allow users to complete their work safely and efficiently, even in dark and noisy environments. The UT196 solar digital multimeter is designed with overload protection of 1700V DC, 1500Vrms AC and tested for safe use in a CAT III 1000V, CAT IV, UK and CA600V, UK and CA 600Vrms certified environment. cETLus. Product specifications: - Multifunctional multimeter designed for use in both outdoor and indoor photovoltaic and wind power installations - measurement of AC/DC voltage, resistance, capacitance, frequency, diodes, circuit continuity, with external current loop and AC current - LCD display -, backlit maximum value -- display: ± 6000, values are updated 2 to 3 times per second - analogue bar graph: yes, 31 segments, measurement rate of 30 times per second - range switching: automatic / manual - automatic AC/DC voltage detection: yes - non-contact electromagnetic field measurement (NCV): yes - diode testing (semiconductor junctions): yes, open-circuit voltage approx. 3V - electrical circuit continuity test: yes, the circuit is considered closed when R ≤ 10Ω, then the buzzer emits a beep - built-in low-pass filter (LPF): yes, when the LPF is activated, interfering voltages above 1.2 kHz are attenuated by ≥ -3 dB/0>Hz relative to the measured attenuationHz. yes - Peak Hold: yes - Data Hold: yes - Max/Min mode: yes - Power supply: 9V battery / 6F22, - Low battery indication: yes, when voltage drops below <7.5V, - automatic switch-off during inactivity -1 - minutes - Built-in torch: yes - audible and visual indicator: yes Technical parameters: DC voltage measurement (V): Range / Resolution / Accuracy 600.0 mV / 0.1 mV / ±(0.5%/1 V/5.0) ±(0.2%+5) 60.00 V / 0.01 V / ±(0.2% + 5) 600.0 V / 0.1 V / ±(0.2% + 5) 1700V / 1V / ±(0.2%+5) The input range is approximately mV/DC. 1GΩ. AC voltage measurement (V): Range / Resolution / Accuracy 600.0 mV / 0.1 mV / 45 Hz to 500 Hz: ± (0.8%+3); 500 Hz to 1 kHz: ± (1.8%+3) 6.000V / 0.001V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3) 60.00 V / 0.01 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3) 600.0V / 0.1V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3) 1500 V / 1 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3) Input impedance in the mV/AC range is approx. 10MΩ. Automatic AC/DC voltage measurement: automatic range / Resolution / Accuracy 0V to 600.0V / 0.1V / DC to 500Hz: ± (2.0%+3); 500 Hz to 1 kHz: ± (4.0%+3) With automatic range selection, LPF, Peak Hold selection is not possible; the input impedance is 2 MΩ Resistance measurement: range / resolution / accuracy 600.0Ω / 0.10Ω / ±20.10Ω / ±20.10Ω 1Ω / ± (0.8%+2) 60.00 kΩ / 10 Ω / ± (0.8% + 2) 600.0 kΩ / 100 Ω / ± (0.8% + 2) 6,000 MΩ / 1 kΩ / ± (1.2%/+6 Ω)<0br/>+3 Ω. (2.5%+5) Capacitance measurement: Range / Resolution / Accuracy 60.00 nF / 0.01 nF / in REL mode: ± (3%+10) 600.0 nF / 0.1 nF / ± (1.9% > +5.00 μF / 0.00 μF / 0.00 μF / 5.00 μF) ± (1.9% + 5) 60.00 μF / 0.01 μF / ± (1.9% + 5) 600.0μF / 0.1μF / ± (1.9%+5) 6,000 mF / 0.001 mF / ± (5% > +5) 0.001 mF / 0.001 mF / ± (5% >+5) ± (5%+5) Measurement of AC currents with a UT-CS09D Flex current loop: Range / Resolution / Accuracy 30.00A / 0.01A / ± (0.8%+8) 300.0A / 0.1A /+300.0A / 0.1A /+0. ± (0.8%+8) Frequency measurement: Range / Resolution / Accuracy 60.00 Hz to 1,000 MHz / 0.1 Hz to 0.001 MHz / ± (0.08% +4) Other operating parameters: -0.001 MHz 40°C (32°F – 104°F) - Storage temperature: -10°C to 50°C (14°F to 122°F) - relative humidity: ≤75% RH (0°C - 30°C), ≤50% RH (30°C) operating altitude - ≤2000m - EMC immunity: in accordance with EN61326-1: 2013, EN61326-2-2: 2013 - Power supply: 9V battery / 6F22 - External dimensions: 195 x 95 x 58 mm - Weight: 4–85 g - Drop test: 2m - Certification: CE, UKCA, cETLus (CAT III 1000V, CAT IV 600V) - Complies with standards: EN61010-1, EN61010-2-033, EN/IEC 61010-031 :-Contents of individual packaging :-/> UT196 Solar PRO multimeter: 1 pc - test leads: 1 pair - 9V/6F22 battery: 1 pc - user manual: 1 pc Manufacturer: UNI-TREND -

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €122,42

  • Last stock! UNI-T UT197 multimeter UNI-T UT197 multimeter

    UNI-T UT197 multimeter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. The UT197 industrial digital multimeter is a high-precision, portable digital multimeter with true RMS and a 600,000-count display. It is IP67-rated, can withstand drops from 5m and operates at temperatures from -40°C to 55°C, making it suitable for harsh outdoor conditions. The built-in anti-interference frequency converter trigger mode filters out carrier frequency interference and distorted voltage for stable inverter measurement. The 1000 A AC/DC current measurement (UT-CS07) with Bluetooth technology allows you to record results via the UNI-T SmartTest app, and generate graphs and tables. It is certified to CAT IV 1000V safety standard (CE, cETLus) and is widely used in the power industry, equipment maintenance, petrochemicals, engineering, HVAC, new energy, factory and laboratory applications. V - AC/DC current: 10 A - number of displays: 600,000 and switchable; 9,999 (Hz) - 12 kV surge protection and EMC protection - IP67 protection and 5 m drop protection - Voltage category: CAT IV 1000 V - Operating environment: -40 °C to 55 °C - Visual alarm at input terminals -/- Automatic backlight function -/> Parameters: Measurement: Range / Accuracy AC current (A): 600.00 μA / 6000.0 μA / 60.000 mA / 600.00 mA / 6.0000 A / 10.000 A ± DC current (0.5% + 0) (0.5% + μA / 0.000 mA) 6000.0 µA / 60,000 mA / 600.00 mA / 6.0000 A / 10.000 A ±(0.1% + 20) AC+DC current (A): 600.0 μA / 6000 μA / 60.00 mA / 60.00 mA / 60.00 mA / 60.00 mA ±(1.0%+5) AC voltage (V): 600.00 mV / 6.0000 V / 60.000 V / 600.00 V / 1000.0 V ±(0.3%+20) DC voltage (60,000 counts): 60.000.000 V / 60.000 V / 600.00 V / 1000.0 V ±(0.03%+5) DC voltage (600,000 counts): 600.00 mV / 6.00000 V / 60.0000 V / 600.000 V / 000 V ±(0.015%+10) Automatic AC/DC voltage measurement: 600.0 V ± (0.8% + 5) Voltage range (ACV+DCV): 600.0 mV / 6.000 V / 60.00 V / 60.00 V / ±10.00 V 5) External current (DC) (optional: UT-CS07): 100.0 A ((10 mV/A)/1000 A (1 V/A) ± (1.5% + 5) External current (AC) (optional: UT-CS07): 100.0 A ((1.5% + 5) External current (AC) (optional: UT-CS07): 100.0 A (()/10V/A (()/10V/A) (1.5% + 5) Frequency measurement (Hz): 10 Hz to 1 MHz ±(0.002% + 5) Resistance measurement (Ω): 600.00Ω / 6.0000kΩ / 60.000kΩ / 600.000kΩ / 600.00kΩ / 600.00kΩ / 0.0000Ω ±(0.07%+2) Capacitance measurement (F): 60.00 nF / 600.0 nF / 6.000 μF / 60.00 μF / 600.0 μF / 6.000 mF / 60.00 mF ±(0.8%/°C+3): Temperature measurement (°C ±3) 1000°C Temperature measurement (°F): -40°F to 1832°F Duty cycle (%): 10 Hz to 10 kHz (10% to 90%) ±(1.25%+5) Functions: Actual display value: -> Display range: 600000 (DCV); 9999 (frequency) - Diode test: 3.0 V - Non-contact measurement - Electrical circuit continuity test (buzzer) - Data hold (manual/Auto) - Peak value hold - Maximum/minimum voltage mode Indicator alarm - Probe misconnection alarm - Overrange indicator - Automatic switch-off when not in use: after 15 minutes - Automatic backlight - Bluetooth function - IP67 protection - 5 m drop test - Power supply: 1.5V AA (R06) batteries: Product -/>- Product dimensions: 2 pcs. 220 mm x 104 mm x 67 mm - Product weight approx. 835 g (including batteries) - Accessories: Measurement cable, temperature probe, clamps, batteries. - Bulk pack: 5 pcs Manufacturer: UNI-TREND.

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €599,09

  • Last stock! UNI-T UT201R Clamp Meter UNI-T UT201R Clamp Meter

    UNI-T UT201R Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT201R Clamp Meter This product comes with a 3-year warranty. The UT201R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours. Product parameters: - measurement of voltage, current and frequency of high voltage up to 600 V - non-contact electric field detection (NCV) - Alarm display and visual protection greater than the audible signal/e.g. 600 V in intervals - automatic range switching - accuracy guaranteed within the range of 1% to 100% of the range Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 4,000 A / 0.001 A / 50 Hz ~ 100 Hz ± (4.0% + 10) 40.00A / 0.010A / 50Hz ~ 100Hz ± 100.0% (2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10) - the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz - Overload protection at 420A.> AC voltage measurement (range / resolution / accuracy): 4,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5) 40.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5) 600.0V / 1.000V / 10Hz ~ 10kHz ± (0.8% + 5) - frequency monitoring accuracy when measuring AC voltage within the resolution range from 1.0% ± 5 at 1.0kHz to 0.01 Hz up to 0.01 kHz - Overload protection at 600 Vrms - Input impedance approx. 10 MΩ 3. DC voltage measurement (range / resolution / accuracy): 400.0 mV / 0.100 mV / ± (0.7% + 3) 4.000 V / 0.001 V / ± (0.5% + 2) 40.00 V / 0.00 V / ±0.3) 400.0V / 0.100V / ± (0.7% + 3) 600 V / 1.000 V / ± (0.7% + 3) - input impedance approx. 10MΩ - overload protection at 600 Vrms 4. Resistance measurement (range / resolution / accuracy): 400.0Ω / 0.1Ω / ± (1.0% + 2) 4,000 kΩ / 0.001 kΩ / ± (0.8% + 2) 40.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2) 400.0 kΩ / 0.1 kΩ / ± (0.8% + 2) 4,000 MΩ / 0.001 MΩ / ± (2.0% + 5) 40.00MΩ / 0.01MΩ / ± (2.0% + 5) overload protection at 6.0% + 5) -50 Vrms 5. Checking circuit continuity: - if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer - if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer - open-circuit voltage approximately 2.0V - measurement in the overload protection range 06 overload -0Ω Vrms 6. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2.0V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 2.2V - within the 4,000 V measurement range 7. Non-contact electric field sensing (NCV): - enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Other parameters: - maximum and minimum measurement value HOLD - year - low battery indicator: yes - auto-off: yes - 1.5 V battery power supply (R03): 2 pcs - backlit display size: 37 mm x 25 mm - product dimensions: 215 mm x 63 mm x 36 mm - net product weight: 2/4 g - grey Package contents: - UT201R clamp multimeter: 1 pc 40 pcs - Standard box dimensions: 485 mm x 295 mm x 385 mm - standard gross weight of box: 16.6 kg MANUFACTURER: UNI-TREND https://www.uni-trend.com/

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €29,30

  • Last stock! UNI-T UT202BT Clamp Meter UNI-T UT202BT Clamp Meter

    UNI-T UT202BT Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values. Capacitance measurement and non-contact voltage detection (NCV) are selected by pressing buttons. The UT202BT features a new design, high reliability and safety, as well as automatic range switching available for all functions. The dual backlit LCD display, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, and current/frequency. There is an LED light on the underside of the test leads. It is powered by two 1.5V R03 AAA batteries. The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree. Parameters: - measurement of AC/DC voltage, AC current, resistance, capacitance, temperature and circuit continuity - Measurement of voltage and current frequency on the auxiliary display - Non-contact electric field sensor (NCV) - Dual LCD display with multi-segment backlight - Increased acoustic and visual protection against voltages of 60V and above - Automatic range switching - Accuracy guaranteed within the range of 5% to 100% of the ranges - Built-in LED torch - Powered by two 1.5V AAA R03 batteries Technical parameters: To ensure measurement accuracy, operating temperature range: -18°C to 28°C 1a. AC current measurement (ranges/resolution/accuracy): 9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30) 99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60) - minimum detectable current: 0.01A - frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz - Overload protection at 60 Hz/> AC current measurement - LPF (range / resolution / accuracy): 6000A / 0.1A / 50Hz to 60Hz ±(4.0%+5) / 600A rms 1c. AC trip current measurement (range / resolution / accuracy): 99.99A / 0.01A / 50Hz to 60Hz ±(10%+10) / 600A rms 6000A / 0.1A / 50Hz ±0% / 60Hz ±60Hz rms 2a. AC voltage measurement (range / resolution / accuracy): 9.999V / 0.001V / 40Hz to 400Hz ±(0.8%+3) 99.99V / 0.010V / 40Hz to 400Hz ±(0.8%+3) 99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3) - The frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified. - Input impedance approx. 10 MΩ - Overload protection at 600Vrms - Minimum detectable voltage 0.6V 2b. AC-LPF voltage measurement (range / resolution / accuracy): 600 V / 0.1 V / 40 Hz to 400 Hz ±(2.0%+5) / 600 V rms 3. DC voltage measurement (range / resolution / accuracy): 9.999 V / 0.001 V / ±(0.5%+3) 99.99V / 0.01V / ±(0.5%+3) 600V / 0.1V / ±(0.5%+3) input approx. 10MΩ - overload protection at 600Vrms - minimum detectable voltage 0.6V 4. Resistance measurement (ranges/resolution/accuracy): 999.9Ω / 0.1Ω / ±(0.8%+3) 9.999 kΩ / 0.001 kΩ / ±(0.8% + 3) 99.99kΩ / 0.01kΩ / 0.01kΩ /%+90kΩ /%+90kΩ />±9kΩ / 0.1kΩ / ±(0.8%+3) 9.999 MΩ / 0.001 MΩ / ±(1.5%+3) 99.99 MΩ / 0.01 MΩ / ±(2.0%+5) - overload protection at 600 Vrms open-circuit voltage approx. - 1V 5. Capacitance measurement (ranges/resolution/accuracy): 99.99 nF / 0.01 nF / ±(4.0%+10) 999.9 nF / 0.1 nF / ±(4.0%+10) 9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5) 99.99 μF / 0.01 μF / ±(4.0% + 5) 999.9 μF / 0.1 μF / ±(4.0% + 5) 9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10) - overload protection at 600 Vrms 6. Checking circuit continuity: - If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined. - open-circuit voltage approx. 3.0 V - Overload protection at 600 Vrms 7. Temperature measurement: -40°C~1000°C / ±(2.0%+5) 8. Non-contact electric field sensing (NCV): - enables acoustic detection of live conductors using a buzzer and optical detection using an LED Other parameters: - jaw opening: 28mm - measurement of maximum and minimum values: yes - yes - Yes, data hold, low battery indication (H/>>- and low data: battery voltage is less than 2.4 V; if the battery voltage is less than approx. 2.2 V, the device cannot be switched on - auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required. - Drop resistance: yes, 1 m - Electromagnetic compatibility: RF ≤ 1 V/m, general accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified - Operating altitude: ≤ 2000m and operating humidity <3000m -: (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH) - storage temperature and humidity: -20 to +60°C (≤ 80%RH) - recommended calibration interval: 1 year - 1-battery power supply: 5 V–2 V (R03) - product dimensions: 201.5 × 47 × 28.5 mm - Weight: approx. 241 g (including batteries); - product colour: red and grey Package contents: - UT202BT clamp multimeter: 1 pc - test leads: 1 pair - temperature probe (K): 1 pc - 2 x R03 instruction manuals - User manual: 1 copy Manufacturer: UNI-TREND

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €54,08

  • Last stock! UNI-T UT202F Clamp Meter UNI-T UT202F Clamp Meter

    UNI-T UT202F Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT202F Clamp Meter This product comes with a 3-year warranty. The UT202F digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 600A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours. Product parameters: - measurement of voltage, current and high-voltage frequency up to 600 V - non-contact electric field detection (NCV) - Frequency measurement from 10 MHz to 600 V 60mF - Measurement of the (relative) ratio of voltages and capacitances - multi-segment display and audible/visual alarm - protection against voltages exceeding 600V in ranges - automatic range switching - accuracy of current and voltage measurements guaranteed within 1% of the technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 6,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% + 10) 60.00A / 0.010A / 50Hz ~ 100Hz ± 10.0% (2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10) - the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz - overload protection at 620A.> AC voltage measurement (range / resolution / accuracy): 6,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5) 60.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% / 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5) - frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz overload protection at the input -0.01kHz overload -0. approx. 10 MΩ 3. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ± (0.7% + 3) 6,000 V / 0.001 V / ± (0.5% + 2) 60.00 V / 0.010 V / ±0.7% 3) 600.0 V / 0.100 V / ± (0.7% + 3) - input impedance approx. 10 MΩ - overload protection at 600 Vrms 4. Resistance measurement (range / resolution / accuracy): 600.0Ω / 0.1Ω / ± (1.0% + 2) 6,000 kΩ / 0.001 kΩ / ± (0.8% + 2) 60.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2) 600.0 kΩ / 0.1 kΩ / ± (0.8% + 2) 6,000 MΩ / 0.001 MΩ / ± (2.0% + 5) 60.00 MΩ / 0.01 MΩ / ± (2.0% + 5) overload protection at 6.0% + 5) -50 Vrms 5. Capacitance measurement (ranges / resolution / accuracy): 6,000 nF / 0.001 nF / ± (4.0% + 10) 60.00 nF / 0.01 nF / ± (4.0% + 10) 600.0 nF / 0.00% + 1.10) 6,000 μF / 0.001 μF / ± (4.0% + 5) 60.00 μF / 0.01 μF / ± (4.0% + 5) 600.0μF / 0.1μF / ± (4.0% + 5) 600.0μF / 0.1μF / ± (4.0% + 5). ± 10.0% 60.00 mF / 0.01 mF / ± 10.0% - overload protection at 600 Vrms 6. Frequency and load measurement (ranges / resolution / accuracy): frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4) Duty cycle: 0.1 to 99.9% / 0.1% / ± 5.0% / ± 5.0% Measurement sensitivity: ≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS > 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS >1 V RMS input > 1 V RMS: amplitude ≤ 30 V RMS - Note 2) Duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95% Duty cycle: 30.0% ~ 70.0% - Overload protection at 600 V rms 7. Circuit continuity check: - if the measured resistance is less than 10Ω, the continuity circuit signal triggers a buzzer - if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer - open-circuit voltage approximately 2.0V - measurement in the overload protection range 60-0Ω during overload Vrms 8. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 3.9V - measurement range of 6.000V Parameters: - measurement of maximum and minimum values: yes - Relative mode (ratio) measurement for voltage and capacitance: yes - HOLD: yes - low battery indicator: yes - auto-off: yes - 1.5 V battery power supply (backlit display size: 3 x 3): 25 mm - Product dimensions: 215 mm x 63 mm x 36 mm - net product weight: 248 g - Product colour: red and grey Package contents: - UT201R clamp multimeter: 1 pc. test leads />- 1 pc. (R03): 2 pcs - user manual: 1 pc Wholesale packaging: - standard quantity per box: 40 pcs - standard box dimensions: 485 mm x 295 mm x 385 mm - standard gross weight per box: 16/F: 7 kg https://www.uni-trend

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €28,47

  • Last stock! UNI-T UT202R Clamp Meter UNI-T UT202R Clamp Meter

    UNI-T UT202R Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT202R Digital Clamp Meter This product comes with a 3-year warranty. The UT202R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours. Product parameters: - measurement of voltage, current and frequency of high voltage up to 600 V - non-contact electric field detection (NCV) - Temperature measurement from -1/>-°C to -100°C, multi-segment display and audible/visual alarm - protection against voltages exceeding 600 V in intervals - automatic range switching - accuracy guaranteed within the range of 1% to 100% of the range Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 4,000 A / 0.001 A / 50 Hz ~ 100 Hz ± (4.0% + 10) 40.00A / 0.010A / 50Hz ~ 100Hz ± 2.0%/100Hz ± (4.0% +10) 0.100 A / 50 Hz ~ 100 Hz ± (2.0% +10) - the frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz - overload protection at 420 A > AC voltage measurement (range / resolution / accuracy): 4,000 V / 0.001 V / 10 Hz to 10 kHz ± (1.0% + 5) 40.00 V / 0.010 V / 10 Hz ~ 10 kHz ± (0.8% / 0.8% +5) / 10 Hz ~ 10 kHz ± (0.8% +5) 600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5) - frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to ± 10 kHz at a resolution of + (10 kHz). 0.01 Hz to 0.01 kHz - Overload protection at 600 Vrms - Input impedance approx. 10 MΩ 3. DC voltage measurement (range / resolution / accuracy): 400.0 mV / 0.100 mV / ± (0.7% +3) 4.000 V / 0.001 V / ± (0.5% +2) 40.00 V / 0.010 V / 0.010 V / 0.010 V / ± (0.7% +3) 0.100 V / ± (0.7% +3) 600 V / 1,000 V / ± (0.7% +3) - input impedance approx. 10MΩ - overload protection at 600 Vrms 4. Resistance measurement (ranges / resolution / accuracy): 400.0Ω / 0.1Ω / ± (1.0% +2) 4,000 kΩ / 0.001 kΩ / ± (0.8% +2) 40.00 kΩ / 0.01 kΩ / 0.01 kΩ / ±40.8 kΩ / ±2.0 kΩ / 0.1 kΩ / ± (0.8% +2) 4,000 MΩ / 0.001 MΩ / ± (2.0% +5) 40.00 MΩ / 0.01 MΩ / ± (2.0% +5) - overload protection at 600 Vrms > Capacitance measurement (ranges / resolution / accuracy): 4,000 nF / 0.001 nF / ± (4.0% +10) 40.00 nF / 0.01 nF / ± (4.0% +10) 400.0 nF / ±4 nF / ±4 nF / ±4 nF (0.01 nF / ± (4.0% +10) +10) 4,000 μF / 0.001 μF / ± (4.0% +5) 40.00 μF / 0.01 μF / ± (4.0% +5) 400.0 μF / 0.1 μF / ± (4.0% +5.0,01 μF / 0.01 μF / ± (4.0% +5)) 10.0% - overload protection at 600 Vrms 6. Temperature measurement (ranges / resolution / accuracy): -40°C to +40°C/1°C / ±4°C +40°C to +500°C/1°C/ ±(1.5% +5) +500°C to +1000°C/±(2°C/1°C/±(1.5% +5) +5) -40°F to +104°F/1°F/± 6°F +104°F to +932°F/1°F/ ± (2.0 +6) +932°F to +1832°F/1°F/ ± (2.5% +4/7) Circuit continuity check: - if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer - if the measured resistance is greater than 31 ohms, the open circuit signal does not emit a buzzer - open-circuit voltage approximately 2.0V - measurement in the overload protection range 06 overload -0Ω Vrms 8. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 2.2V - measurement in the 4.900 V range /> Non-contact electric field sensor (NCV): - enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V / 50 / 60Hz and 230V / 50 / 60Hz Other parameters: Measurement value: HOLD: Yes - low battery indication: Yes - Auto-off: Yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 37 mm x 25 mm - Product dimensions: 215 mm x 63 mm x 36 mm - Net product weight: - 24 g Product colour:24-8 g grey Package contents: - UT202R clamp multimeter: 1 pc Box: 40 pcs - Standard box dimensions: 485 mm x 295 mm x 385 mm - standard gross weight of box: 17.1 kg MANUFACTURER: UNI-TREND https://www.uni-trend.com/

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €31,40

  • Last stock! UNI-T UT202T Clamp Meter

    UNI-T UT202T Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. The UT202T is an easy-to-use smart clamp multimeter that can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values. Capacitance measurement and non-contact voltage measurement (NCV) are selected by pressing buttons. The UT202T features a new design, high reliability and safety, as well as automatic range switching available for all functions. Dual backlit LCD screen, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, current/frequency. There is an LED lamp on the underside of the test leads. It is powered by two 1.5V AAA R03 batteries. The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree. : - measurement of AC/DC voltage, AC current, resistance, capacitance and circuit continuity - measurement of voltage and current frequency on the auxiliary display - Non-contact voltage detection (NCV) - dual LCD display with multi-segment backlight - Audible and visual alarm - protection against voltage ranges exceeding 60 V - switching - accuracy guaranteed between 5% and 100% of the range - built-in LED torch - powered by two 1.5V AAA R03 batteries Technical specifications: To ensure measurement accuracy, the operating temperature must be within the range of 18°C to 28°C 1. AC current measurement (ranges/resolution/accuracy): 9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30) 99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60) - minimum detectable current: 0.01A - frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz - overload protection /> /200 Hz AC voltage measurement (range / resolution / accuracy): 9.999 V / 0.001 V / 40 Hz to 400 Hz ±(0.8%+3) 99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8% + 3) 99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3) - Frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude ≥5Vrms at a frequency from 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified. - Input impedance approx. 10 MΩ - Overload protection at 600 Vrms - Minimum detectable voltage 0.6 V 3. DC voltage measurement (range / resolution / accuracy): 9.999 V / 0.001 V / ±(0.5%+3) 99.99 V / 0.01 V / ±(0.5% + 3) 600 V / 0.1 V / ±(0.5% + 3) input approx. 10 MΩ - overload protection at 600Vrms - minimum detectable voltage 0.6V 4. Resistance measurement (ranges/resolution/accuracy): 999.9Ω / 0.1Ω / ±(0.8%+3) 9.999 kΩ / 0.001 kΩ / ±(0.8% + 3) 99.99 kΩ / 0.01 kΩ / 0.01 kΩ / %+90 kΩ / %+90 kΩ / >±9 kΩ / 0.1 kΩ / ±(0.8%+3) 6,000 MΩ / 0.001 MΩ / ±(1.5%+3) - overload protection at 600 Vrms - open-circuit voltage approx. 1 V 5. Capacitance measurement (ranges/resolution/accuracy): 99.99 nF / 0.01 nF / ±(4.0%+10) 999.9 nF / 0.1 nF / ±(4.0%+10) 9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5) 99.99 μF / 0.01 μF / ±(4.0% + 5) 999.9 μF / 0.1 μF / ±(4.0% + 5) 9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10) - overload protection at 600 Vrms 6. Checking circuit continuity: - If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined. - open-circuit voltage approximately 3.0 V - Overload protection at 600 Vrms 7. Non-contact electric field sensing (NCV): - enables acoustic detection of live conductors using a buzzer and visual detection using an LED Other parameters: - jaw opening: 28 mm - measurement of maximum and minimum values: yes -: data hold indication - low battery - yes, if the battery voltage is less than 2.4V; if the battery voltage is less than approx. 2.2V, the device cannot be switched on - auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required. - Drop resistance: yes, 1 m - Electromagnetic compatibility: RF ≤ 1 V/m, overall accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified - Operating altitude: ≤2000m, operating temperature and humidity: +3/0°C -0°C (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH) - storage temperature and humidity: -20 to +60°C (≤ 80%RH) - recommended calibration interval: 1 year - 1-battery power supply: 5 V–2 V (R03) - Product dimensions: 201.5 × 47 × 28.5 mm - UT202T weight: approx. 241g (including batteries); - Product colour: red and grey Package contents: - UT202T multimeter clip: 1 pc - test leads: 1 pair - 1.5 V battery (R03): 2 pcs - user manual - pcs Wholesale packaging: - standard quantity per box: 40 pcs - standard carton dimensions: 485 x 295 x 385 mm - standard gross weight of carton: approx. 17 kg Manufacturer: UNI-TREND -

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €36,01

  • Last stock! UNI-T UT203R Clamp Meter UNI-T UT203R Clamp Meter

    UNI-T UT203R Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT203R Clamp Multimeter This product comes with a 3-year warranty. The UT203R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 400A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours. Product parameters: - measurement of voltage, current and frequency of high voltage up to 600 V - measurement of frequencies from 10 Hz to 10 MHz - Measurement capabilities -400V - 40 mF - measurement of the (relative) ratio of voltages and capacitances - multi-segment display and audible/visual alarm - protection against voltages exceeding 600V in intervals - non-contact detection of live conductors - automatic range switching - measurement accuracy of current and voltage is guaranteed to within 1% across 10% of ranges Technical parameters: 1. AC measurement (ranges / resolution / accuracy): 40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5) 400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) current monitoring accuracy ± 5) the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz - overload protection at 620 A 2. DC current measurement (ranges / resolution / accuracy): 40.00A / 0.010A / ± (2.0% +5) 400.0 A / 0.100 A / ± (2.0% + 5) - overload protection at 620 A > > 4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5) 40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.8% +5) / 10Hz ~ 10kHz ± (0.8% +5) 600.0V / 1V / 10Hz ~ 10kHz ± (0.8% +5) - frequency monitoring accuracy when measuring AC voltage in the range from 10Hz to 60kHz at a resolution of ±0.01 kHz - Overload protection at 600 Vrms - Input impedance approx. 10 MΩ 4. DC voltage measurement (range / resolution / accuracy): 400.0 mV / 0.100 mV / ± (0.7% +3) 4.000 V / 0.001 V / ± (0.5% +2) 40.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2) 600.0V / 1V / ± (0.5% +2) - input impedance approx. 10MΩ - Overload protection at 600 Vrms 5. Resistance measurement (ranges / resolution / accuracy): 400.0Ω / 0.1Ω / ± (1.0% +2) 4,000 kΩ / 0.001 kΩ / ± (0.8% +2) 40.00kΩ / 0.01kΩ / 0.01kΩ / ±2.0% 0.8kΩ / ±2.0kΩ / 0.1kΩ / ± (0.8% +2) 4.000 MΩ / 0.001 MΩ / ± (2.5% +5) 40.00 MΩ / 0.01 MΩ / ± (2.5% +5) - overload protection at 600 Vrms open circuit - approx. 1V 6. Capacitance measurement (range / resolution / accuracy): 40.00 nF / 0.01 nF / ± (4.0% +5) 400.0 nF / 0.1 nF / ± (4.0% +5) 4.000 μF / 0.001 μF / ± (4.0% +5) 40.00 μF / 0.01 μF / ± (4.0% +5) 400.0 μF / 0.1 μF / ± (4.0% +5) 4,000 μF / 0.001 μF / ± 10.0% - overload protection at 600 Vrms 7. Frequency and load measurement (ranges / resolution / accuracy): frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4) Duty cycle: 0.1 to 99.9% / 0.1% / ± (5) Note/+5. Sensitivity: ≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS > 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS > 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS - Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency Operating frequency 1 kHz 30.0% ~ 70.0% - overload protection at 600 Vrms 8. Checking circuit continuity: - if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer - if the measured resistance is greater than 31Ω, the open circuit signal does not emit a buzzer - uncertainty in the range from 10Ω to 31Ω. 600Ω range - Overload protection at 600 Vrms 9. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 4.0V - measurement in the range of 6.000V Non-contact voltage detection (NCV): - enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz Other parameters: - Measurement of maximum and minimum values (ratio) for voltage and capacitance: yes - HOLD: yes - low battery indicator: yes - Auto-off: yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 37 mm x 25 mm - Product dimensions: 63 mm - x 63 mm - net product weight: 235 g - product colour: red and grey Package contents: - UT204R clamp multimeter: 1 pc - test leads: 1 pair - 1.5 V battery (R03): 2 pcs user manual - 1 pc Wholesale packaging: - standard quantity per box: 40 pcs - standard box dimensions: 485 mm x 295 mm x 385 mm - standard gross weight of box: 16.1 kg MANUFACTURED BY UNIVERSITATEA www.

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €66,66

  • Last stock! UNI-T UT204R Clamp Meter

    UNI-T UT204R Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT204R Clamp Multimeter This product comes with a 3-year warranty. The UT204R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on low-voltage distribution lines in CAT II. With the included Type K thermocouple (nickel-chromium-nickel-silicon temperature sensor), it allows temperature measurement from -40°C to 1000°C. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is <11μA, which effectively extends the battery life to approximately 400 hours. Product parameters: - measurement of voltage, current and high-voltage frequency up to 600 V - frequency measurement from 10 Hz to 10 MHz - Measurement capabilities - 60 mF - Temperature measurement from -40 to +1000 °C - Measurement of the (relative) ratio of voltages and capacitances - multi-segment display and audible/visual alarm - protection against voltages exceeding 600 V in intervals - Non-contact detection of live voltages and switching accuracy of live conductors - guaranteed within the range of 1% to 100% of the range Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5) 600.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) The accuracy of AC frequency monitoring in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz - overload protection at 620 A 2. DC current measurement (ranges / resolution / accuracy): 60.00 A / 0.010 A / ± (2.0% + 5) 600.0 A / 0.100 A / ± (2.0% + 5) - overload protection at 620 A > > 6,000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5) 60.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.0% +5) / 10Hz ~ 10kHz ± (0.8% +5) - frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to 60 kHz ± (0.5% + 2) at a resolution of 0.01 Hz to 0.01 kHz - input overload protection - 0.01 kHz - overload protection - 60/0 V rm. 10 MΩ 4. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ± (0.7% +3) 6,000 V / 0.001 V / ± (0.5% +2) 60.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2) - input impedance approx. 10MΩ - overload protection at 600 Vrms 5. Resistance measurement (ranges / resolution / accuracy): 600.0Ω / 0.1Ω / ± (1.0% +2) 6,000 kΩ / 0.001 kΩ / ± (0.8% +2) 60.00 kΩ / 0.01 kΩ / 0.01 kΩ / 60.8 kΩ ±2.0 kΩ 0.1 kΩ / ± (0.8% +2) 6,000 MΩ / 0.001 MΩ / ± (2.5% +5) 60.00 MΩ / 0.01 MΩ / ± (2.5% +5) - overload protection at 600 Vrms open circuit - approx. 1V 6. Capacitance measurement (ranges / resolution / accuracy): 60.00 nF / 0.01 nF / ± (4.0% +5) 600.0 nF / 0.1 nF / ± (4.0% +5) 6000 μF / 0.001 μF / ±4.0% +5) 60.00 μF / 0.01 μF / ± (4.0% +5) 600.0 μF / 0.1 μF / ± (4.0% +5) 6,000 mF / 0.001 mF / ± 10.0% - overload protection at 600 Vrms 7. Temperature measurement (ranges / resolution / accuracy): -40°C to +40°C / 1°C / ± 4°C +40°C to +500°C/1°C / ± (1.5% +5) +500°C to +1000°C/±2°C/1.5°C -40°F to +104°F / 1°F / ± 6°F +104°F to +932°F / 1°F / ± (2.0 +6) +932°F to +1832°F / 1°F / ± 4 % Frequency and load measurement (ranges / resolution / accuracy): frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% +4) load: 0.1 to 99.9% / 0.1% / ±5) Note/+5. Sensitivity: ≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS > 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS > 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS - Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency Operating frequency 1 kHz 30.0% ~ 70.0% - Overload protection at 600 Vrms 9. Checking circuit continuity: - if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer - if the measured resistance is greater than 31Ω, the open-circuit signal does not emit a buzzer - uncertainty in the range from 10Ω to 31Ω. 600Ω range - Overload protection at 600 Vrms 10. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 4.0V - measurement in the range of 6.000V Non-contact electric field sensing (NCV): - enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz Other parameters: - measurement of maximum and minimum values - relative measurement of maximum and minimum. Mode (ratio) for voltage and capacitance measurement: yes - HOLD: yes - low battery indicator: yes - auto-off: yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 37 mm x 25 mm - Product dimensions: 631.5 mm x 631 mm - net product weight: 235 g - Product colour: red and grey Package contents: - UT204R clamp multimeter: 1 pc - Test leads: 1 pair - K-type thermocouple up to 101 V: 0 pcs (R03): 2 pcs - user manual: 1 pc Wholesale packaging: - standard quantity per box: 40 pcs - standard box dimensions: 485 mm x 295 mm x 385 mm - standard gross weight per box: 16/F: 7 kg https://www.uni-trend.com/

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €75,04

  • UNI-T UT205E Clamp Meter

    UNI-T UT205E Clamp Meter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT205E Clamp Multimeter This product comes with a 3-year warranty. The UT205E digital clamp meter is used for measuring AC and DC voltages up to 1000 V, AC currents up to 1000 A and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum displayable value is 6000. The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive inductive current loop. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends the battery life. The power-saving function can be disabled. Product specifications: - measurement of AC/DC voltage and AC current, resistance, diodes, continuity, capacitance - automatic polarity display - current frequency measurement in the range from 40 to 60 Hz and up to low voltages (10 Hz) V0040 at 400 Hz - Measurement of low-voltage frequency (mn) in the range from 10 Hz to 1 MHz - capacitance measurement from 60 nF to 60 mF - Measurement of the (relative) ratio of voltages and capacitances - Multi-segment display and audible/visual protection against voltages exceeding 100 V - Intervals - NCV function – non-contact detection of live conductors - Frequency/duty cycle measurement function - Choice of automatic or manual range switching - Built-in lamp - Accuracy of current and voltage measurement is guaranteed when using the range within the 5% to 100% range; no adjustment of the 5% to 100% range is required Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9) 600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5) - the frequency monitoring accuracy when measuring AC current in the range from 40 to 60Hz is ± (0.1% + 3) at a resolution of 0.1Hz - Overload protection at 1000A 2. AC voltage measurement (range / resolution / accuracy): 6,000 V / 0.001 V / 40 Hz ~ 400 Hz ±(1.2%+3) 60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8) 1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8) - frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz - Overload protection at 1000 Vrms - Input impedance approx. 10 MΩ 3. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.8%+3) 6,000 V / 0.001 V / ±(0.5% + 3) 60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5% + 3) 1000.0 V / 1 V / ±(0.5%+3) - overload protection at 1000Vrms - input impedance approx. 10 MΩ 4. Resistance measurement (range / resolution / accuracy): 600.0Ω / 0.1Ω / ±(1.0%+3) 6,000 kΩ / 0.001 kΩ / ±(1.0% + 2) 60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2) 6,000 MΩ / 0.001 MΩ / ±(2.0%+8) 60.00 MΩ / 0.01 MΩ / ±(2.0%+8) - overload protection at 1000 Vrms open-circuit voltage approx. - 1 V 5. Checking circuit continuity: - if the measured resistance is less than 30Ω, the continuity signal emits a beep - with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep - uncertainty between 31Ω and 69Ω - 600Ω, with a resolution of 0.1Ω - overload protection at 1000 Vrms 6. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 3.0V - measurement in the 000V range, with a resolution of 6.00 V, 0.001 V 7. Capacitance measurement (range / resolution / accuracy): 60.00 nF / 0.01 nF / ±(4.0%+25) 600.0 nF / 0.1 nF / ±(4.0%+5) 6.000 μF / 0.001 μF ±(4.0%+5) 60.00 μF / 0.01 μF / ±(4.0% + 5) 600.0 μF / 0.1 μF / ±(4.0%+5) 6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9 - overload protection at 1000 Vrms 8. Frequency measurement and duty cycle (duty) (ranges / resolution / accuracy): frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3) duty cycle: 10% to 99.1% / ±99.0% / ±7) - Note 1) Measurement sensitivity: 10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS 100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz: 2Vpp ≤ input amplitude ≤ 20V p-p - overload protection at 1000 Vrms 9. Non-contact electric field sensor (NCV): - enables the detection of live wires - as the detected voltage increases, the buzzer will sound at a higher volume and the LED will begin to flash. Other parameters: - measurement of maximum and minimum values: yes relative capacitance measurement mode: yes - HOLD: yes - low battery indicator: yes - auto-off: yes - Powered by 1.5 V batteries (R03): 2 pcs - backlit display size: 43 x 45 mm - Product dimensions: 272 x 81 x 43.5 mm - Net product weight - 43.5 mm colour: red and grey Package contents: - UT205E clamp multimeter: 1 pc - test leads: 1 pair - 1.5 V battery (R03): 3 pcs - user manual: 1 pc > Standard box packaging: 10 pcs - standard box dimensions: 355 mm x 330 mm x 315 mm - standard gross weight of box: 7.1 kg MANUFACTURER: UNI-TREND https://www.uni-trend.com/

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €70,85

  • Last stock! UNI-T UT206B Clamp Meter

    UNI-T UT206B Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT206B Clamp Multimeter This product comes with a 3-year warranty. The UT206B digital clamp meter is used to measure AC and DC voltages up to 1000 V, AC currents up to 1000 A, and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive inductive current loop. Option to purchase a flexible loop for measuring currents up to 3000 A. Power supply: 3 x 1.5 V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled. Product specifications: - measurement of AC/DC voltage and AC current, resistance, diodes, continuity, capacitance - automatic polarity display - measurement of frequency of low-voltage (LV) currents and voltages up to 1000–40 V/Hz measurement of low-voltage (LV) frequency in the range 10 Hz to 1 MHz - capacitance measurement from 60 nF to 60 mF - temperature measurement from -40 to +1000 °C with a closed K-type thermocouple - Measurement of the (relative) ratio of voltages and capacitances for alarm and multiple alarms – e.g. protection against voltages exceeding 1000 V in intervals - NCV function – non-contact detection of live conductors - LoZ V function – measurement with low input impedance (approx. 2 kΩ) of the device - INRUSH function – measurement of transients up to 100 ms – with an additional start-up duration of up to 30,000 A. loop - LPF ACV function – AC voltage measurement with low-pass filter (approx. 2.5 kHz) on inverters and variable-frequency drives - Frequency/duty cycle measurement function - Choice between automatic or manual switching - Built-in lamp - Current and voltage accuracy are guaranteed when current and voltage measurement is within 10% of the value; if the value falls outside this range, the range must be changed Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9) 600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5) - the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz - Overload protection at 1000A 2. AC inrush current measurement (ranges / resolution / accuracy): 60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10) 600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) - overload protection at 1000A with flexible current loop 30.00A / 0.000Hz / 40.010Hz ±(10.0%+10) 300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection -10 3000A 3. AC voltage measurement (range / resolution / accuracy): 6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3) 60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3) 60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8) 1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8) - frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz - Overload protection at 1000 Vrms - Input impedance approx. 10 MΩ 4. LPF AC V (measurement with low-pass filter approx. 2.5 kHz) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ 5. AC LPF V (measurement with low input impedance approx. 2 kΩ) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) - Input overload protection rm approx. 2kΩ 6. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.8%+3) 6,000 V / 0.001 V / ±(0.5%+3) 60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3) 1000.0 V / 1 V / ±(0.5%+3) - overload protection at 1000Vrms - input impedance approx. 10 MΩ 7. Resistance measurement (range / resolution / accuracy): 600.0Ω / 0.1Ω / ±(1.0%+3) 6,000 kΩ / 0.001 kΩ / ±(1.0% + 2) 60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2) 6,000 MΩ / 0.001 MΩ / ±(2.0%+8) 60.00 MΩ / 0.01 MΩ / ±(2.0%+8) - overload protection at 1000 Vrms open-circuit voltage approx. - 1 V 8. Checking circuit continuity: - if the measured resistance is less than 30Ω, the continuity signal emits a beep - with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep - uncertainty between 31Ω and 69Ω - 600Ω, with a resolution of 0.1Ω - overload protection at 1000 Vrms 9. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 3.0 V - measurement in the 000V range, with a resolution of 6.00 V, 0.001 V 10. Capacitance measurement (range / resolution / accuracy): 60.00 nF / 0.01 nF / ±(4.0%+25) 600.0 nF / 0.1 nF / ±(4.0%+5) 6,000 μF / 0.001 μF ±(4.0%+5) 60.00 μF / 0.01 μF / ±(4.0% + 5) 600.0 μF / 0.1 μF / ±(4.0%+5) 6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9 - overload protection at 1000 Vrms 11. Temperature measurement (ranges / resolution / accuracy): -40°C to +300°C / 0.1°C / ± 1.0°C+20 +300°C to +1000°C / 1°C / ±(1.0%+2) +573°F to +1832°F / 1°F / ±(1.0%+4) 12. Frequency measurement and operating cycle (filling) (ranges / resolution / accuracy): frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3) Fill: 10% to 99.1% / ±99.0% / ±7) - Note 1) Measurement sensitivity: 10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS 100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz: 2Vpp ≤ input amplitude ≤ 20V p-p - overload protection at 1000 Vrms 13. Non-contact electric field sensing (NCV): - allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes - HOLD: yes - low battery indicator: yes - Auto power off: yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 43 x 45 mm - Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 492g - Product colour: red and grey Package contents: - UT206B clamp multimeter: 1 pc - Test leads: 1 pair - K-type thermocouple up to 1000°C: 1 pc 3: >-R<03/> user manual: 1 pc Wholesale packaging: - standard quantity per box: 10 pcs - standard box dimensions: 355 mm x 330 mm x 315 mm - standard gross weight per box: 7.1 kg MANUF UNI-TREND https://www.uni-trend.com/

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €83,43

  • UNI-T UT207B Clamp Meter UNI-T UT207B Clamp Meter

    UNI-T UT207B Clamp Meter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT207B Clamp Meter This product comes with a 3-year warranty. The UT207B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 10,000,000 V in the range of 1,000,000 V at 400 Hz and low voltage (LV) from 10 Hz to 1 MHz. It features protection against voltages exceeding 1,000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled. Product specifications: - measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance - automatic polarity display - measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range from 10 Hz to 1 MHz - capacitance measurement from 60 nF to 60 mF - Measurement of the (relative) ratio of voltages and capacitances - Multi-segment display and audible/visual alarm - protection against voltages higher than 10V/0V - contact function without NC - live conductors - LoZ V function ~ measurement with low input impedance (approx. 2kΩ) of the device - INRUSH function – measurement of transients up to 100 ms in length – inrush current at device start-up up to 3000 A with additional flexible loop - LPF ACV measurement function on nf2H5 filter (approx. inverters and variable frequency drives - Frequency/duty cycle measurement function - Choice between automatic or manual range switching - Built-in lamp - Accuracy of current and voltage measurement is guaranteed when using the range between 5% and 100% of the full scale; at 5% of the full scale, a technical adjustment is required > Parameters: 1. AC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9) 600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5) - the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz - Overload protection at 1000A 2. AC inrush current measurement (ranges / resolution / accuracy): 60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10) 600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) - overload protection at 1000A with flexible current loop 30.00A / 0.000Hz / 40.010Hz ±(10.0%+10) 300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection -10 3000A 3. DC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / ±(2.0%+5) 600.0A / 0.100A / ±(2.0%+5) 1000.0A / 1A / ±(2.0%+5) overload protection 2.0%/>-5 1000A 4. AC voltage measurement (range / resolution / accuracy): 6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3) 60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3) 60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8) 1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8) - frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz - Overload protection at 1000 Vrms - Input impedance approx. 10 MΩ 5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ 6. AC LPF V (measurement with low input impedance approx. 2 kΩ) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) - Input overload protection rm approx. 2kΩ 7. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.8%+3) 6,000 V / 0.001 V / ±(0.5%+3) 60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3) 1000.0 V / 1 V / ±(0.5%+3) - overload protection at 1000Vrms - input impedance approx. 10 MΩ 8. Resistance measurement (range / resolution / accuracy): 600.0Ω / 0.1Ω / ±(1.0%+3) 6,000 kΩ / 0.001 kΩ / ±(1.0% + 2) 60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2) 6,000 MΩ / 0.001 MΩ / ±(2.0%+8) 60.00 MΩ / 0.01 MΩ / ±(2.0%+8) - overload protection at 1000 Vrms open-circuit voltage approx. - 1 V 9. Checking circuit continuity: - if the measured resistance is less than 30Ω, the continuity signal emits a beep - with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep - uncertainty between 31Ω and 69Ω - 600Ω, with a resolution of 0.1Ω - overload protection at 1000 Vrms 10. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 3.0V - measurement in the 000V range, with a resolution of 6.00 V, 0.001 V 11. Capacitance measurement (range / resolution / accuracy): 60.00 nF / 0.01 nF / ±(4.0%+25) 600.0 nF / 0.1 nF / ±(4.0%+5) 6,000 μF / 0.001 μF ±(4.0%+5) 60.00 μF / 0.01 μF / ±(4.0% + 5) 600.0 μF / 0.1 μF / ±(4.0%+5) 6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9 - overload protection at 1000 Vrms 12. Frequency measurement and duty cycle (duty) (ranges / resolution / accuracy): frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3) duty cycle: 10% to 99.1% / ±99.0% / ±7) - Note 1) Measurement sensitivity: 10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS 100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz: 2Vpp ≤ input amplitude ≤ 20V p-p - overload protection at 1000 Vrms 13. Non-contact electric field sensing (NCV): - allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes - HOLD: yes - low battery indicator: yes - Auto power off: yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 43 x 45 mm - Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g - Product colour: red and grey Package contents: - UT207B multimeter clip: 1 pc - Test leads: 1 pair - 1.5 V battery (R03): 3 pcs - user manual - 1 pc - user manual Packaging: - standard quantity per box: 10 pcs - standard box dimensions: 355 mm x 330 mm x 315 mm - standard gross weight per box: 7.1 kg MANUFACTURER: UNI-TREND https://www.uni-trend

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €116,97

  • UNI-T UT208B Clamp Meter

    UNI-T UT208B Clamp Meter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT208B Clamp Multimeter This product comes with a 3-year warranty. The UT208B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 100000000000V at 400Hz and low voltage (mn) 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows LV distribution measurements in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled. Product specifications: - measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance - automatic polarity display - Measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range 10 Hz to 1 MHz - capacitance measurement from 60 nF to 60 mF - Temperature measurement from -40 to +1000 °C with a closed K-type thermocouple - measurement of the (relative) ratio of voltages and voltages and capacitances multiple visual protection voltages greater than 1000 V in ranges - NCV function – non-contact detection of live conductors - LoZ V function ~ measurement with low input impedance (approx. 2 kΩ) of the device - INRUSH function – measurement of transients up to 100 ms – inrush current on device start-up with an additional 3,000,000 loop at the LPF ACV function – AC voltage measurement with an NF filter (approx. 2.5 kHz) on inverters and variable-frequency drives - Frequency/duty cycle measurement function - Choice between automatic or manual switching - Built-in lamp - Accuracy of current and voltage measurement is guaranteed when using the range from 10% to 10%; within 5% of this range, it is necessary to change the range Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9) 600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5) - the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz - Overload protection at 1000A 2. AC inrush current measurement (ranges / resolution / accuracy): 60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10) 600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) - overload protection at 1000A with flexible current loop 30.00A / 0.000Hz / 40.010Hz ±(10.0%+10) 300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection -10 3000A 3. DC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / ±(2.0%+5) 600.0A / 0.100A / ±(2.0%+5) 1000.0A / 1A / ±(2.0%+5) overload protection 2.0%/>-5 1000A 4. AC voltage measurement (range / resolution / accuracy): 6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3) 60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3) 60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8) 1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8) - frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz - Overload protection at 1000 Vrms - Input impedance approx. 10 MΩ 5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ 6. AC LPF V (measurement with low input impedance approx. 2 kΩ) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) - Input overload protection rm approx. 2kΩ 7. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.8%+3) 6,000 V / 0.001 V / ±(0.5%+3) 60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3) 1000.0 V / 1 V / ±(0.5%+3) - overload protection at 1000Vrms - input impedance approx. 10 MΩ 8. Resistance measurement (range / resolution / accuracy): 600.0Ω / 0.1Ω / ±(1.0%+3) 6,000 kΩ / 0.001 kΩ / ±(1.0% + 2) 60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2) 6,000 MΩ / 0.001 MΩ / ±(2.0%+8) 60.00 MΩ / 0.01 MΩ / ±(2.0%+8) - overload protection at 1000 Vrms open-circuit voltage approx. - 1 V 9. Checking circuit continuity: - if the measured resistance is less than 30Ω, the continuity signal emits a beep - with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep - uncertainty between 31Ω and 69Ω - 600Ω, with a resolution of 0.1Ω - overload protection at 1000 Vrms 10. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 3.0V - measurement in the 000V range, with a resolution of 6.00 V, 0.001 V 11. Capacitance measurement (range / resolution / accuracy): 60.00 nF / 0.01 nF / ±(4.0%+25) 600.0 nF / 0.1 nF / ±(4.0%+5) 6,000 μF / 0.001 μF ±(4.0%+5) 60.00 μF / 0.01 μF / ±(4.0% + 5) 600.0 μF / 0.1 μF / ±(4.0%+5) 6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9 - overload protection at 1000 Vrms 12. Temperature measurement (ranges / resolution / accuracy): -40°C to +300°C / 0.1°C / ± 1.0°C+20 +300°C to +1000°C / 1°C / ±(1.0%+2) +573°F to +1832°F / 1°F / ±(1.0%+4) 13. Frequency measurement and operating cycle (filling) (ranges / resolution / accuracy): frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3) Fill: 10% to 99.1% / ±99.0% / ±7) - Note 1) Measurement sensitivity: 10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS 100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz: 2Vpp ≤ input amplitude ≤ 20V p-p - overload protection at 1000 Vrms 14. Non-contact electric field sensing (NCV): - allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will start flashing. (ratio) for voltage and capacitance measurement: yes - HOLD: yes - low battery indicator: yes - Auto power off: yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 43 x 45 mm - Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g - Product colour: red and grey Package contents: - UT208B clamp multimeter: 1 pc - Test leads: 1 pair - K-type thermocouple up to 1000°C: 1 pc 3: >- (battery 3): user manual: 1 pc Wholesale packaging: - standard quantity per box: 5 pcs - standard box dimensions: 355 mm x 330 mm x 165 mm - standard gross weight per box: 4.5 kg UNI-TREND MANUFACTURE https://www.uni-trend.com/

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €150,51

  • Last stock! UNI-T UT210A Clamp Meter UNI-T UT210A Clamp Meter

    UNI-T UT210A Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT210A Clamp Meter This product comes with a 3-year warranty. UNI-T UT210A Mini Clamp * small AC clamp * sensitive * input protection SPECIFICATIONS 2 AC current/A20A0 ±(1.0%+9) FEATURES Display range 2000 Jaw capacity 17mm Data hold LCD backlight Auto power off Low battery indicator Input protection TOTAL POWER TOTAL POWER: (2x) LCD size: 39.3 x 26.5 mm Weight: 160g Dimensions: 155x60x33.5mm ACCESSORIES Battery, manual MANUFACTURER: UNI-TREND

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €23,43

  • Last stock! UNI-T UT210B Clamp Meter UNI-T UT210B Clamp Meter

    UNI-T UT210B Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT210B Clamp Meter This product comes with a 3-year warranty. UNI-T UT210B Mini Clamp * small AC clamp * sensitive * input protection * TRMS * NCV/ACTION ACTION Current 2A/20A/200A ±(1.0%+9) FEATURES Display range 2000 TRMS NCV MAX/MIN Relative mode Jaw capacity 17mm Data Hold Auto stop Auto shut-off LCD Battery indicator Input protection GENERAL FEATURES Power: 1.5V AAA (2x) LCD size: 39.3 x 26.5 mm Weight: 160g Dimensions: 155 x 60 x 33.5 mm, Battery / Battery Manual MANUFACTURER: UNI-TREND

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €26,79

  • Last stock! UNI-T UT210C Clamp Meter UNI-T UT210C Clamp Meter

    UNI-T UT210C Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT210C Clamp Meter This product comes with a 3-year warranty. UNI-T UT210C Clamp Meter TECHNICAL SPECIFICATIONS AC Current (A) 2A/20A/200A 20A+/200A ±/200A ±/200A Voltage (V) 2V/20V/200V/600V ±(1.0%+3) DC Voltage (V) 200mV/2V/20V/200V/600V ±(0.7%+3) Resistance (Ω) 200Ω/2kΩ/M20kΩ/20kΩ/M200Ω/20kΩ ±(1.0%+2) Capacitance (F) 20nF/200nF/2μF /20μF/200μF/2mF/20mF ±(4%+5) Temperature (℃) -40~1000℃) ±(1℉/+3) Temperature -40~1832℉ ±(1.5%+5) FEATURES Display count   2000 Auto range   √ Jaw capacity   17mm True RMS  />V  />√ √ A. NCV   √ Auto shut-off: Approx. 15 minutes √ Continuity buzzer   √ Low battery indication ≤2.5V √ Data hold   √ MAX mode/√ /√ Relative √ LCD backlight   √ Input protection   √ Input impedance for DCV ≥10MΩ √ GENERAL SPECIFICATIONS Power supply: 2 x 1.5V AAA batteries Net product dimensions LCD 329.3mm> Weight 170 g Product dimensions 175 mm x 60 mm x 33.5 mm ACCESSORIES Battery, test lead, contact-point temperature probe MANUFACTURER UNI-TREND

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €54,08

  • Last stock! UNI-T UT210D Clamp Meter UNI-T UT210D Clamp Meter

    UNI-T UT210D Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT210D Clamp Meter This product comes with a 3-year warranty. UT210D Clamp Meter The UT210 series mini clamp meters are designed to perform well in confined spaces. They are essential tools for the maintenance of mechanical and electrical equipment, the installation of household appliances and electrical work. 1. NCV 2. Ergonomic and lightweight 3. Automatic range, sampling rate of 2–3 times per second 4. True RMS 5. ZERO mode 6. LCD backlight, data hold 7. Auto power off, low battery indicator Specifications: Range AC current (A): 200A ±(2.5%+8) DC current (A): 200A ±(2%+3) AC voltage (V): 600V ±(1%+3) DC voltage (V/>60) ±(0.7%+3) Resistance (Ω): 20MΩ ±(1%+2) Frequency (Hz): 60kHz ±(0.1%+4) Capacitance (F): 20mF ±(4%+5) Temperature: ±0°C ±0%+4) -40~1832℉ ±(1.5%+5) Features: Display count: 2000 Continuity buzzer √ Automatic range   √ Jaw opening  />170 mm 17 mm General features: Power: 1.5V battery (R03) x 2 Display: 39.3 mm x 26.5 mm Product colour: red and grey Net product weight: 170g Product dimensions: 175mm x 3.5mm x 3.5mm x 3.5mm Accessories: batteries, test leads, spot contact temperature probe Standard individual packaging: gift box, English manual, carrying case Standard quantity per box: 40 pcs www.uni-trend.com

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €79,24

  • Last stock! UNI-T UT210E Clamp Meter UNI-T UT210E Clamp Meter

    UNI-T UT210E Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT210E Clamp Meter This product comes with a 3-year warranty. UNI-T UT210E – small clamp multimeter SPECIFICATIONS AC currents 2A/20A/100A ±(2.5%+5A0)A0 A0 A0 ±(2.5%+3) AC voltage 2V/20V/200V/600V ±(1%+3) Direct voltage ±(0.7%+3) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200kΩ/2MΩ ±(1%+2) Capacitance 2nF/20nF/200nF/2μF/20μF/200μF/2mF/20mF ±(4%+5) FUNCTIONS Display count 2000 J Auto open 17 mm TRMS Diode test NCV Data hold Zero mode Display backlight Auto power off Continuity buzzer Low battery indicator Input protection Input impedance DCV/GENERAL+10MΩ/GENERAL> FEATURES Power: 2x1.5V AAA batteries Weight: 170g Dimensions: 175x60x33mm LCD size: 39x26mm ACCESSORIES: battery, test leads, carrying case

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €62,47


You have seen 816 out of 1139 products

© 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

  • American Express
  • Apple Pay
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Union Pay
  • Visa

Login

Forgot your password?

Don't have an account yet?
Create account