In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT203R Clamp Multimeter
This product comes with a 3-year warranty. The UT203R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 400A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- measurement of frequencies from 10 Hz to 10 MHz
- Measurement capabilities
-400V
- 40 mF
- measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600V in intervals
- non-contact detection of live conductors
- automatic range switching
- measurement accuracy of current and voltage is guaranteed to within 1% across 10% of ranges
Technical parameters:
1. AC measurement (ranges / resolution / accuracy):
40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5)
400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) current monitoring accuracy ± 5) the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620 A
2. DC current measurement (ranges / resolution / accuracy):
40.00A / 0.010A / ± (2.0% +5)
400.0 A / 0.100 A / ± (2.0% + 5)
- overload protection at 620 A
>
>
4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.8% +5) / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10Hz to 60kHz at a resolution of ±0.01 kHz
- Overload protection at 600 Vrms
- Input impedance approx. 10 MΩ
4. DC voltage measurement (range / resolution / accuracy):
400.0 mV / 0.100 mV / ± (0.7% +3)
4.000 V / 0.001 V / ± (0.5% +2)
40.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2)
600.0V / 1V / ± (0.5% +2)
- input impedance approx. 10MΩ
- Overload protection at 600 Vrms
5. Resistance measurement (ranges / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000 kΩ / 0.001 kΩ / ± (0.8% +2)
40.00kΩ / 0.01kΩ / 0.01kΩ / ±2.0% 0.8kΩ / ±2.0kΩ / 0.1kΩ / ± (0.8% +2)
4.000 MΩ / 0.001 MΩ / ± (2.5% +5)
40.00 MΩ / 0.01 MΩ / ± (2.5% +5)
- overload protection at 600 Vrms open circuit
- approx. 1V
6. Capacitance measurement (range / resolution / accuracy):
40.00 nF / 0.01 nF / ± (4.0% +5)
400.0 nF / 0.1 nF / ± (4.0% +5)
4.000 μF / 0.001 μF / ± (4.0% +5)
40.00 μF / 0.01 μF / ± (4.0% +5)
400.0 μF / 0.1 μF / ± (4.0% +5)
4,000 μF / 0.001 μF / ± 10.0%
- overload protection at 600 Vrms
7. Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
Duty cycle: 0.1 to 99.9% / 0.1% / ± (5)
Note/+5. Sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
> 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS
- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency
Operating frequency
1 kHz 30.0% ~ 70.0%
- overload protection at 600 Vrms
8. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31Ω, the open circuit signal does not emit a buzzer
- uncertainty in the range from 10Ω to 31Ω. 600Ω range
- Overload protection at 600 Vrms
9. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 4.0V
- measurement in the range of 6.000V
Non-contact voltage detection (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz
Other parameters:
- Measurement of maximum and minimum values (ratio) for voltage and capacitance: yes
- HOLD: yes
- low battery indicator: yes
- Auto-off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 63 mm
- x 63 mm
- net product weight: 235 g
- product colour: red and grey
Package contents:
- UT204R clamp multimeter: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 2 pcs user manual
- 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight of box: 16.1 kg
MANUFACTURED BY UNIVERSITATEA www.
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT306C professional non-contact infrared thermometer can quickly and accurately measure surface temperatures ranging from -50 °C to +500 °C by measuring the infrared energy radiated by the target surface. To make aiming the device at the target surface easier and more intuitive, a ring laser is built in, which indicates correct aiming of the thermometer. The distance-to-spot ratio is 12:1 with this device. This thermometer is drop-resistant from a height of 1 metre. It is possible to preset the emissivity of the measured surface within the range of 0.1 to 1.0. The display of preset functions and measured values is provided by a clear, high-contrast EBTN colour display, whilst limit values are indicated by an audible alarm and on the display. It is possible to display minimum, maximum and average temperatures, as well as deviations from the average (MIN, MAX, AVG, DIF). The thermometer switches off automatically to reduce power consumption if left unused for 15 seconds in HOLD mode and 10 seconds in other modes. The temperature measurement time is up to 250 ms in 95% of cases. The device is powered by two 1.5V AAA zinc-manganese or alkaline batteries.
This non-contact infrared thermometer can be used in a variety of fields, such as the food industry, vehicle maintenance, metalworking, cold storage and other industries.
Product specifications for non-contact surface measurement:
- temperature range - 50 °C to +500 °C, can be switched to °F
- the measured surface is delineated by a circular laser pointer
- the ratio of distance to measured surface diameter is 12:1 with this instrument
- EBTN2 colour display contrast x/2 EBTN2 measurement limit value
- 6 mm measurement limit value indicator via a buzzer and on the display
- powered by two 1.5 V AAA ZnMn or alkaline batteries
Technical parameters:
- Temperature range: -50 ℃ to + 500 ℃ (-58 ℉ to + 500 ℃ (-58 ℉ to + 500 ℃ (-58 °F to +500 °C) -50 °C to 0 °C: ± (2 °C + 0.1 °C/°C)
- measurement accuracy between 0 °C and 500 °C: ± 2 °C or ± 2% (whichever is greater)
- measurement accuracy between -58 °F and 32 °F: ± 32 °F
- measurement accuracy between 32 °F and 932 °F: ± 4.0 °F or ± 2% (whichever is greater)
- resolution: 0.1 °C / 0.1 °F
- spectral response: 8μm to 14μm
- response time: 9 ms/≤ 25 ms/distance to measured surface diameter: 12:1
- circular laser measurement area delimitation: yes
- Class 2 ring laser: wavelength 630 nm to 670 nm, output power ≤1 mW
- display: high-contrast EBTN with backlight, measuring 25 x 26 mm; emissivity range 0.1 to 1.0; default 0.95
- measurement lock: yes
- powered by two 1.5 V AAA batteries: ZnMn or alkaline
- ZnMn battery life: continuous temperature measurement ≥6 hours (laser on + display backlight)
- Automatic switch-off when inactive: yes
- low battery indicator: yes 1 m
- Temperature alarm mode: HI / LO (high / low alarm with audible signal)
- MAX / MIN / AVG / DIF hold: yes
- Operating temperature: 0 ℃ to 50 ℃ (32 ℉ to 122 ℉)
- Operating humidity:
- 90% RH: storage temperature: -20 ℃ to 60 ℃ (-4 ℉ to 140 ℉)
- Product colour: red and grey
- Net product weight: 161.5 g
- Product dimensions: 146 x 94.5 x 46 mm
-
UT306C: 1 pc
- 1.5V / AAA batteries: 2 pcs
- cover: 1 blister pack
- manual: 1 pc
Packaging for wholesale customers:
- standard quantity per box: 20 pcs standard box: 20 pcs x box: 755 dimensions
75 mm
MANUFACTURER: UNI-TREND
https://www.uni-trend.cz/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT210E Clamp Meter
This product comes with a 3-year warranty. UNI-T UT210E – small clamp multimeter
SPECIFICATIONS
AC currents
2A/20A/100A ±(2.5%+5A0)A0
A0
A0 ±(2.5%+3)
AC voltage
2V/20V/200V/600V ±(1%+3)
Direct voltage ±(0.7%+3)
Resistance
200Ω/2kΩ/20kΩ/200kΩ/2MΩ/200kΩ/2MΩ ±(1%+2)
Capacitance
2nF/20nF/200nF/2μF/20μF/200μF/2mF/20mF ±(4%+5)
FUNCTIONS
Display count 2000
J Auto open
17 mm
TRMS
Diode test
NCV
Data hold
Zero mode
Display backlight
Auto power off
Continuity buzzer
Low battery indicator
Input protection
Input impedance DCV/GENERAL+10MΩ/GENERAL> FEATURES
Power: 2x1.5V AAA batteries
Weight: 170g
Dimensions: 175x60x33mm
LCD size: 39x26mm
ACCESSORIES: battery, test leads, carrying case
This product comes with a 3-year warranty. The UT802 bench multimeter is a multifunctional electronic measuring instrument. It meets the requirements for measuring electrical parameters during the maintenance of electronic devices, offering high precision and ease of use. Its advantages include numerous functions and the ability to operate even outside the 230V mains supply range, as it can also run on batteries. The device features a backlit LCD display with a display range of ±19999. The device is manufactured in accordance with IEC 61010-1 standards and complies with CAT II 1000V.
Product specifications:
- large backlit LCD display, measuring 108 x 34.5 mm, with a maximum display range of 19999
- with a single-range circular switching/measuring function
- circular switching/measurement
AC/DC voltage and current, resistance, capacitance, frequency and temperature
- Measurement of semiconductor junctions: diodes and transistors
- measurement of transistor hFE parameters
- circuit continuity testing with buzzer
- Data Hold function
- Power supply via AC/20m3V20 adapter or 1.5 V DC batteries; R14
- storage space for the adapter
Technical specifications:
- DC voltage measurement in the range: 200 mV to 1000 V with an accuracy of ±(0.1% + 3)
- AC voltage measurement in the ranges: 5 to 20 V up to 70 V ±(0.5%+20)
- DC current measurement in the ranges: 200 µA to 10 A with an accuracy of ±(0.5% + 20)
- DC current measurement in the range: 2 mA to 10 A with an accuracy of ±(0.8% + 40)
Resistance measurement in the range 20Ω to 0Ω: 200MΩ with an accuracy of ±(0.5%+10)
- Capacitance measurement in the range: 20nF to 200µF with an accuracy of ±(4%+10)
- Frequency measurement in the ranges: 2kHz and 200kHz with ±(0.1) – 200kHz with a measurement accuracy in the temperature range of ±(0.1) – 40°C to 1000°C with an accuracy of ±(1.2%+25)
- Input impedance for DC ranges: approx. 10 MΩ
- automatic polarity display: yes
- low battery warning: yes
- included in delivery is a type K temperature probe for temperatures up to +230°C
- operating environment: 0°C to 40°C
- Storage temperature: -10°C to 50°C
- Relative humidity: 75% in the temperature range from 0°C to 30°C; max 50% in the temperature range from 30°C to 40°C
- dimensions: 300 x 245 x 105 mm
- weight without accessories: 1.5 kg
- weight with accessories: 1.65 kg
- product colour: red and green
Device contents:
2:
2 1 pc
- 230V AC/9V DC/200mA adapter: 1 pc
- International adapter for power supply: 1 pc
- 1.5V battery, R14: 6 pcs
- Type K contact temperature probe: 1 pc
- measurement cables: 1 pair user manual
- 1 pair
> pcs
Wholesale package contents:
- number of units in a standard box: 4 pcs
- standard carton dimensions: 680 x 365 x 320 mm
- weight of standard box: 11.7 kg
TREND
-
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT256A Multimeter
This product comes with a 3-year warranty. The UT256A digital multimeter is a safe and reliable clamp-on meter that can replace a clamp-on multimeter. It has no moving mechanical parts, making it resistant to mechanical failure. The device has a display with a maximum reading of 6000. The use of a Hall-effect probe allows AC current to be measured up to 200A. Using the included test leads, AC and DC voltage, resistance and wire continuity can also be measured; it features a built-in non-contact AC voltage (NCV) sensor and a built-in lamp. It features data hold, automatic and manual range selection, a backlit display, frequency measurement and a low battery indicator. The maximum wire diameter that can be inserted into the clamp is 15 mm. Range overrun is indicated by a red LED, and for NCV by an audible signal. A key advantage is its resistance to drops from a height of up to 2 m. Powered by two 1.5 V AA batteries. These features make the UT256A multimeter a practical tool for the daily work of high-voltage electricians.
Product specifications:
- measurement of AC current up to 200 A and its frequency in the range of 50 Hz to 60 Hz
- AC voltage measurement up to 10 V at 10 Hz to 10 kHz
- DC voltage measurement up to 1000 V
- Resistance measurement up to 60 MΩ
- Line continuity check
- Automatic polarity display
- Option to select automatic or manual range switching
- Built-in lamp
- True RMS value on the backlit LCD display
-
measuring 35 mm x 26 mm
- hold
- powered by two 1.5 V AA batteries
- low battery indicator
- automatic switch-off after 15 minutes (function can be temporarily disabled)
Technical specifications:
AC current measurement range:
- accuracy)
200.0 A / 0.1 A / ± (1.8 % + 2) in the range from 0.2 A to 2.0 A, 50 to 60 Hz
200.0 A / 0.1 A / ± (1.8% + 3) in the range from 2.0 to 6 A, at 50 to 60 Hz
200.0 A / 0.1 A / ± (1.8 % + 5) in the range from 5.0 A to 200 A, 50 to 60 Hz
- the accuracy of frequency monitoring when measuring AC current above 20 A, in the range from 50 to 60 Hz, is ± (0.1% + - 60 Hz) at an overcurrent protection resolution of 0.1% Hz
0. 200 A
- AC voltage measurement:
(ranges / resolution / accuracy)
6,000 V / 0.001 V / ± (1.2% + 3), in the range from 10 Hz to 10 kHz
V / 0.00 ± 2 V / 6% 3), in the range from 10 Hz to 10 kHz
600.0 V / 0.1 V / ± (1.2% + 3), in the range from 10 Hz to 10 kHz
1000.0 V / 1 V / ± (1.2 % + 8), in the range from 1.2 % + 8 kHz, in the range from 10 Hz to 10 kHz
RMS voltage value in the frequency range from 45 Hz to 400 Hz
- the accuracy of frequency monitoring when measuring AC voltage in the range from 10 Hz to 10 kHz is ± (0.1% + 5) at a resolution of 0.01 Hz to 0.01 kHz, with overcurrent protection at amplitudes
- Input impedance approx. 10 MΩ
- DC voltage measurement:
(ranges / resolution / accuracy)
6,000 V / 0.001 V / ± (0.8 % +3)
60.00 V / 0.010 V / ± (0.8 % > V / 60 / 0.8 % > V / 60 / 0.8 % +3) ± (0.8 % +3)
1,000.0 V / 1 V / ± (1.0 % +5)
- overload protection at 1000 Vrms
- input impedance approx. 10 MΩ
- Resistance measurement:
(ranges / resolution / accuracy)
600.0 Ω / 0.1 Ω / ± (1.2 % + 2)
6,000 kΩ / 0.001 kΩ / ± (1.0 %/0.0 Ω / ± 0.0 Ω / ± (1.2 % + 2) 0.01 kΩ / ± (1.0 % + 2)
600.0 kΩ / 0.1 kΩ / ± (1.0 % + 2)
6,000 MΩ / 0.001 MΩ / ± (1.2 % + 2)
60.00 MΩ / 0.001 MΩ / ± (1.2 % + 2)
60.00 MΩ / 0.01 (1.0 % + 2) 5)
- overload protection at 1000 Vrms
- open-circuit voltage approx. 1 V
- Circuit continuity check:
- if the measured resistance is less than 10 Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 100 Ω, the open-circuit signal does not sound a buzzer
- open-circuit voltage of approximately 1/060 V
-0 V. Ω, with a resolution of 0.1 Ω
- Overload protection at 1000 Vrms
- Non-contact electric field sensing (NCV):
- low voltage detection mode ("EFLo") for voltages <48V
- low voltage detection mode ("EFHi") for voltages >-48V: as the voltage increases, the number of segments on the display increases, the green, yellow and red LEDs flash in succession and an audible signal is emitted
General parameters:
- Operating temperature and ambient humidity: 0 °C ~ 30 °C (≤80% RH), 30 °C ~ 40 °C (≤40% RH), 40 °C ~ 40 °C (≤45% RH)
- Storage temperature and humidity: -20 °C ~ 60 °C (≤80% RH)
- Operating altitude: ≤2000m
- Electromagnetic compatibility: in an RF field of 1 V/m, there is an additional error of 5% of the range; in an RF field >1 V/m, overall accuracy is not specified
- Product dimensions: 217 x 58.8 x 38.5 mm
- net product weight: 251 g
- Product colour: red and grey
- This device is designed in accordance with IEC safety standards EN61010-1, IEC/EN61010-2-033 and EN61326-1 and complies with CAT II 1000V, CAT III 600V, double insulation.
Package contents:
- UT256A clamp multimeter: 1 pair of UT256A test leads: 1 pair of test leads. 1.5 V battery (LR6): 2 pcs
- User manual: 1 pc
Wholesale packaging:
- standard quantity per box: 20 pcs
- Standard box dimensions: 485 x 310 x 205 mm
- Standard gross weight per box: 9 kg
R. UNI-TREND
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT60BT is a digital multimeter with a display range of 9999, allowing for the measurement of true RMS values of voltages and currents with both automatic and manual range selection. It features 1000V rms overload protection across all ranges; the current range is protected by a 10A / 1000V tubular fuse, 6.35 x 32mm. If you approach the limit values of ≥990.0V / ≥9.900A when measuring voltages and currents, an alarm sounds and the character ‘OL’ is displayed when the limit values are exceeded. It also allows the measurement of resistance, capacitance, temperature, frequency, duty cycle, circuit continuity and semiconductor junctions. The circuit is optimised for non-contact electric field measurement in two sub-ranges. The multimeter is equipped with a modern processor featuring a fast analogue-to-digital converter (3 conversions per second) and transmits measured values via Bluetooth using the low-energy wireless technology 802.15.4 to a mobile phone or tablet with the Connect app installed.
The entire multimeter housing is fitted with a durable, double-insulated casing and has European CE certification, meeting the safety classification CAT II 1000V / CAT III 600V. The device is suitable for use in a laboratory or workshop, as well as for general electrical work. It is powered by three standard 1.5V AAA batteries, which, thanks to their low power consumption, last up to 500 hours.
Product specifications:
- backlit display range: 9999
- voltage measurement: up to ± 1000V / DC / AC to ± rms current measurement / DC: up to ± rms AC rms
- Resistance measurement: up to 99.99MΩ
- Capacitance measurement: up to 9.999mF
- Temperature measurement: up to 250 °C with the supplied K-type probe
- Frequency measurement: up to 9.999 MHz
- Manual measurement:
- Automatic measurement:
- Manual measurement:
Hz / REL / RMS / HOLD / NCV EFLo / NCV EFHi
- Circuit continuity measurement
- Semiconductor junction measurement
- Non-contact NCV measurement
- visual and audible alarms
- Bluetooth for transmitting measured data
- input overload protection
- 0–10 A input current via fast-acting fuse
- Input impedance approx. 10MΩ for DCV, in the DCmV range then 3GΩ
- power supply: 3 x 1.5V, AAA
- Low power consumption during measurement: approx. 2 mA
- Sleep mode current consumption: <30 μA
- Battery life: 500 hours (automatic battery shut-off)
- Automatic battery shut-off indicator: 500 hours (sleep mode): yes, after 15 minutes
Technical parameters:
- DC voltage measurement (input impedance is approximately 3GΩ in the DCmV range, 10MΩ in other ranges):
(range / resolution / accuracy)
9.9090 % (± 9.90 mV / mV / ± 9.90 mV) + 8)
99.99 mV / 0.01 mV / ± (0.7% + 8)
999.9 mV / 0.1 mV / ± (0.5 % + 3)
9.999 V / 0.001 V / ± (0.5 % / 9 V / ± (0.5 % + 3)
(0.5% + 3)
999.9 V / 0.1 V / ± (0.5 % + 3)
- Maximum input voltage: ± 1000 V, alarm sounds at 990.0 V, ‘OL’ is displayed at >1000 V.
- Overload protection 1000 V AC / AC/AC
/>
Voltage measurement (input impedance approx. 10 MΩ):
(range / resolution / accuracy in the range 40 Hz to 400 Hz, RMS sine wave)
9.999 mV / 0.001 mV / ± (1 % + 3)
99.99 mV //3.01 mV //> 999.9 mV / 0.1 mV / ± (0.8 % + 3)
9.999 V / 0.001 V / ± (0.8 % + 3)
999.9 V / 0.1 V / ± (0.8 % + 3)
- Maximum input voltage 0 V, alarm 0 V, 0.10 V AC; ‘OL’ is displayed at >1000 V.
- Overload protection 1000 V RMS (DC / AC)
- DC current measurement:
(range / resolution / accuracy)
999.9 μA / 0.1 μA / ± (0.8% / mA) / 90% + 390 mA. ± (1.0% + 3)
9.999 A / 0.001 A / ± (1.0% + 3)
- Alarm sounds at ≥9,900 A, ‘OL’ is displayed at >10.00 A.
- Overload protection: 1000 V RMS,
measurement:
(range / resolution / accuracy in the range from 40 Hz to 400 Hz)
999.9 μA / 0.1 μA / ± (1.0% + 3)
999.9 mA / 0.1 mA / ± (1.2% + 0.1 mA / ± (1.2% + 3). (1.2% + 3)
- Alarm sounds at ≥9,900 A, ‘OL’ is displayed at >10,000 A.
- Overload protection: 1000 V RMS, 10 A fast-acting fuse
- Resistance measurement:
(range / resolution //>09 accuracy)
Ω / ± (0.8% + 2)
9.999 kΩ / 0.001 kΩ / ± (0.8% + 2)
99.99 kΩ / 0.01 kΩ / ± (0.8 % + 2)
999.9 kΩ / ± 0.1 kΩ / ± 0.1 kΩ / ± (0.1 kΩ)
9.999 MΩ / 0.001 MΩ / ± (1.5 % + 3)
99.99 MΩ / 0.01 MΩ / ± (2.0 % + 5)
- Overload protection 1000V
- Capacitance measurement:
Accuracy range nF 9 /
0.001 nF / ± (4% + 10)
99.99 nF / 0.01 nF / ± (4% + 5)
999.9 nF / 0.01 nF / ± (4% + 5)
9.999 µF / 0.01% / ± 5)
99.99 µF / 0.01 µF / ± (4% + 5)
999.9 μF / 0.1 μF / ± (4% + 5)
9.999 mF / 0.001 mF / ± (10%)
- For Rn-type capacitors, use Rn capacitors
1000 V overload protection
- Frequency measurement:
(range / resolution / accuracy)
99.99 Hz to 9.999 MHz / 0.01 Hz to 0.001 MHz / ± (0.1% + 5)
- Overload protection 0.00 V RMS (0.00 V DC) AC)
- Duty cycle measurement for square waves ≤10 kHz:
(range / resolution / accuracy)
0.1% to 99.9% / 0.1% / ± (3% + 5)
Overload protection 1000 V DC -
/>
test:
voltage across terminals without load approx. 3.3 V
voltage drop across a good silicon junction is 0.5 to 0.8 V
measurement resolution 0.001 V
- Circuit continuity test:
the buzzer will not sound if the resistance is lower than the sound
30 if the resistance is less than 30 Ω
Overload protection 1000V RMS (DC / AC)
- Temperature measurement:
(range / resolution / accuracy)
-40 °C to 0 °C / 1 °C / ± 4 °C
0 °C to 10 °C / ± 100 °C / (±5 °C)
100 °C to 1000 °C / 1 °C / ± (2.0% + 5)
-40 °F to 32 °F / 1 °F / ± 5 °F
> 32 °F to 212 °F / 1 °F / ± 5 °F / ± 2% / ± 5 °F
1832 °F / 1 °F / ± (2.5% + 5)
The K-type thermocouple included as an accessory is only suitable for measuring temperatures below 250 °C / 482 °F.
1000 V RMS (DC / AC) overload protection
General operating temperature:
> 40 °C
- storage temperature: -10 °C to 50 °C (14 °F to 122 °F)
- Operating relative humidity: ≤75% (0 °C to 30 °C), ≤50% (30 °C to 40 °C)
- Operating altitude: 0 m to 20 °C
- EMC resistance: for radio frequency field 1V/m
- Power supply: 3 x 1.5V, AAA
- Product colour: red and grey
- Net product weight: 290 g
- Product weight: approx. 400 g (including batteries)
- Product dimensions: 16 x 84 mm
Contents of individual package:
- UT60BT multimeter with storage case: 1 pc
- 1.5V AAA battery: 3 pcs
- F1 fuse: F 10A / 250V (6.35 x 32mm) - Category II test lead set:
1 pc 1000V / CAT III 600V: 1 pair
- temperature probe: 1 pc
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 20 pcs
- standard box dimensions: 420 x 03>
-
- Manufacturer: UNI-TREND
-
This product comes with a 3-year warranty.
The UT196 True RMS solar multimeter from UNI-T is a professional-grade product designed for professionals who install or maintain photovoltaic or wind power plants. The device’s design allows it to operate in harsh outdoor environments – it has IP65 protection and can withstand a drop from a height of 2 m. This multimeter measures DC voltage up to 1700 V and AC voltage (true RMS) up to 1500 V at a frequency range of 45 to 1000 Hz. With the optional UT-CS09D Flex current loop, it allows non-contact measurement of AC currents from 1.5 to 3000 A, even in confined spaces. In addition, the UT196 measures frequency, resistance, capacitance, semiconductor transitions and electrical circuit continuity.
The low-pass function allows you to filter out RF interference generated by the inverter. The low-impedance mode can help with troubleshooting sensitive circuits, as well as circuits that may contain stray voltages. A built-in torch, a bright backlight, and audible and visual alarms allow users to complete their work safely and efficiently, even in dark and noisy environments.
The UT196 solar digital multimeter is designed with overload protection of 1700V DC, 1500Vrms AC and tested for safe use in a CAT III 1000V, CAT IV, UK and CA600V, UK and CA 600Vrms certified environment. cETLus.
Product specifications:
- Multifunctional multimeter designed for use in both outdoor and indoor photovoltaic and wind power installations
- measurement of AC/DC voltage, resistance, capacitance, frequency, diodes, circuit continuity, with external current loop and AC current
- LCD display
-, backlit maximum value
-- display: ± 6000, values are updated 2 to 3 times per second
- analogue bar graph: yes, 31 segments, measurement rate of 30 times per second
- range switching: automatic / manual
- automatic AC/DC voltage detection: yes
- non-contact electromagnetic field measurement (NCV): yes
- diode testing (semiconductor junctions): yes, open-circuit voltage approx. 3V
- electrical circuit continuity test: yes, the circuit is considered closed when R ≤ 10Ω, then the buzzer emits a beep
- built-in low-pass filter (LPF): yes, when the LPF is activated, interfering voltages above 1.2 kHz are attenuated by ≥ -3 dB/0>Hz relative to the measured attenuationHz. yes
- Peak Hold: yes
- Data Hold: yes
- Max/Min mode: yes
- Power supply: 9V battery / 6F22,
- Low battery indication: yes, when voltage drops below <7.5V, - automatic switch-off during inactivity
-1
- minutes
- Built-in torch: yes
- audible and visual indicator: yes
Technical parameters:
DC voltage measurement (V): Range / Resolution / Accuracy
600.0 mV / 0.1 mV / ±(0.5%/1 V/5.0)
±(0.2%+5)
60.00 V / 0.01 V / ±(0.2% + 5)
600.0 V / 0.1 V / ±(0.2% + 5)
1700V / 1V / ±(0.2%+5)
The input range is approximately mV/DC. 1GΩ.
AC voltage measurement (V): Range / Resolution / Accuracy
600.0 mV / 0.1 mV / 45 Hz to 500 Hz: ± (0.8%+3); 500 Hz to 1 kHz: ± (1.8%+3)
6.000V / 0.001V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)
60.00 V / 0.01 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
600.0V / 0.1V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)
1500 V / 1 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
Input impedance in the mV/AC range is approx. 10MΩ.
Automatic AC/DC voltage measurement: automatic range / Resolution / Accuracy
0V to 600.0V / 0.1V / DC to 500Hz: ± (2.0%+3); 500 Hz to 1 kHz: ± (4.0%+3)
With automatic range selection, LPF, Peak Hold selection is not possible; the input impedance is 2 MΩ
Resistance measurement: range / resolution / accuracy
600.0Ω / 0.10Ω / ±20.10Ω / ±20.10Ω 1Ω / ± (0.8%+2)
60.00 kΩ / 10 Ω / ± (0.8% + 2)
600.0 kΩ / 100 Ω / ± (0.8% + 2)
6,000 MΩ / 1 kΩ / ± (1.2%/+6 Ω)<0br/>+3 Ω. (2.5%+5)
Capacitance measurement: Range / Resolution / Accuracy
60.00 nF / 0.01 nF / in REL mode: ± (3%+10)
600.0 nF / 0.1 nF / ± (1.9% > +5.00 μF / 0.00 μF / 0.00 μF / 5.00 μF) ± (1.9% + 5)
60.00 μF / 0.01 μF / ± (1.9% + 5)
600.0μF / 0.1μF / ± (1.9%+5)
6,000 mF / 0.001 mF / ± (5% > +5)
0.001 mF / 0.001 mF / ± (5% >+5) ± (5%+5)
Measurement of AC currents with a UT-CS09D Flex current loop: Range / Resolution / Accuracy
30.00A / 0.01A / ± (0.8%+8)
300.0A / 0.1A /+300.0A / 0.1A /+0. ± (0.8%+8)
Frequency measurement: Range / Resolution / Accuracy
60.00 Hz to 1,000 MHz / 0.1 Hz to 0.001 MHz / ± (0.08% +4)
Other operating parameters: -0.001 MHz 40°C (32°F – 104°F)
- Storage temperature: -10°C to 50°C (14°F to 122°F)
- relative humidity: ≤75% RH (0°C - 30°C), ≤50% RH (30°C) operating altitude -
≤2000m
- EMC immunity: in accordance with EN61326-1: 2013, EN61326-2-2: 2013
- Power supply: 9V battery / 6F22
- External dimensions: 195 x 95 x 58 mm
- Weight: 4–85 g
- Drop test: 2m
- Certification: CE, UKCA, cETLus (CAT III 1000V, CAT IV 600V)
- Complies with standards: EN61010-1, EN61010-2-033, EN/IEC 61010-031 :-Contents of individual packaging :-/>
UT196 Solar PRO multimeter: 1 pc
- test leads: 1 pair
- 9V/6F22 battery: 1 pc
- user manual: 1 pc
Manufacturer:
UNI-TREND
-
This product comes with a 3-year warranty. The UT276A+ from UNI-T is a clamp-on tester for earth resistance. Based on the principle of mutual induction, it can measure earth resistance without disconnecting the earth conductors and without auxiliary electrodes, in both multi-point and single-point earthing systems.The tester is designed for professional use, with resistance to shocks, dust and humidity, and is controlled by a microprocessor for precise identification of earth resistance, including via the rapid interference filtering method. It is designed for measuring earthing systems in power stations, power distribution and telecommunications, oil fields, computer rooms, electromechanical installations and maintenance in industrial plants, wherever electricity is used as an industrial power source, or where it is necessary to check the earthing resistance of lightning protection systems. The device measures earth loop resistance from 0.01 Ω to 500 Ω with a resolution of 0.001 Ω; the measured values are shown on a four-digit backlit EBTN display (data shown against a dark background). The unit is powered by four 1.5V alkaline batteries.Manufactured in accordance with safety standard IEC 61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC 61010-031.
Product specifications:
- earth loop resistance measurement range: 0 to 500Ω- automatic range selection- resolution 0.001 Ω- 4-digit EBTN display- with audible resistance limit setting- Audible signal when resistance limit is exceeded- high reliability and durability, double insulation- automatic calibration, calibration resistance loops- capacity to store up to 300 sets of measured data- powered by 4 x 1.5V AA alkaline batteries- low battery indicator
Technical parameter: method: mutual induction- earth loop resistance measurement range: 0 to 500Ω
- Measurement resolution and accuracy:in the sub-range 0.01 to 0.099 Ω: 0.001Ω / ± (1% + 0.01Ω)
in the sub-0.01Ω range: 0.01Ω / ± (1% + 0.01Ω)in the secondary range from 1 to 49.9 Ω: 0.1 Ω / ± (1% + 0.1 Ω)in the secondary range from 50 to 99.5 Ω: 0.5 Ω / ± (1.5% + 0.1 Ω to 901 Ω)in the secondary range from 50 to 99.5 Ω: Ω: 1 Ω / ± (2% + 1 Ω)in the sub-range 200 to 395 Ω: 5 Ω / ± (5% + 5 Ω)in the sub-range 400 to 590 Ω: 10 Ω / ± (10% + 10 Ω)
display dimensions: 8-4 TN x 5Ω)
mm- measurement frequency: 2x / sec- jaw opening: 32 x 55 mm- Interference signal filter: yes- visual and audible alarm: yes- data storage: yes, for 300 groups- Display hold (HOLD): yesV (power supply 4 pcs: 16 V) (LR6)- current consumption: max. 50mA- low battery indicator: yes- Auto-off: yes, after 5 minutes- Sheath insulation resistance: more than 20 MΩ (500 V between circuit and pack)- voltage withstand: 3700 V / RMS AC (between circuit and package)- maximum 40 mA external magnetic field field: <1V/m- Category: CAT III 300V, CAT IV 150V (IEC 61010-1)- Operating ambient temperature and relative humidity: 23°C ± 5°C, humidity <75%- Tester dimensions L x W x H: 285 mm x 8 mm x 85 mm x 8 mm, 1180 g (including batteries)
Contents of individual package:
- UT276A+ tester: 1 pc- 1Ω and 10Ω test (calibration) loops: 1 pc- 1.5 V AA (LR6) battery: 4 pcs.
- standard quantity per box: 1 pc- standard box dimensions: 370 x 110 x 300 mm- total weight of the box: 2.6 kg
Manufacturer:https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
The UNI-T UT261A phase sequence tester is designed to check the phase sequence and direction of rotation in three-phase motors. It is an essential tool for electricians and technicians, used in switchboards and industrial installations where the motor’s direction of rotation must be checked with precision.
After connecting the test leads to the L1, L2, L3 terminals of the unit and to the motor leads, the LCD display quickly indicates the direction of rotation: clockwise or anti-clockwise.
Key features
Checks the phase sequence and direction of rotation of three-phase motors
3 input terminals for connecting the phases
Measurement category CAT III 600V – safe use in switchboards
Battery-free operation, inductive power supply from the circuit under test
Clear, easy-to-read LCD display
Technical specifications
Measuring voltage: 90 – 600V AC
Frequency: 15 – 400 Hz
Measuring current per phase: up to 1 mA
Standards: IEC61010 / EN61010, IEC61557-7
Dimensions: 123 x 71 x 29 mm
Weight: 160 g
Operating temperature: 0°C – 40°C
Storage temperature: 0°C – 50°C
Maximum altitude: 2000 m
Relative humidity: ≤95%
Pollution class: 2
Protection rating: IP40
Package contents
UNI-T UT261A phase sequence tester
3 × CAT III, 600V test leads
3 × extension leads with alligator clips
User manual (English)