The UT622C LRC device is a portable component tester — coils (inductance), resistors (resistance) and capacitors (capacitance) — and their secondary properties: D (loss factor), Q (quality factor), Θ (phase angle in degrees), Θ (phase angle in radians) and ESR (equivalent series resistance or parallel resistance). Component parameters are measured using alternating voltage with a selectable frequency of 100, 120, 1000, 10000 Hz, 100 kHz and a selectable amplitude of 0.1 Vrms, 0.3 Vrms, 1.0 Vrms at a signal source output impedance of 100Ω. The highest measurement accuracy is 0.1%.
The device features an intuitive 2.8-inch TFT LCD display with ten-level adjustable backlight brightness, a built-in high-capacity 1800mAh Li-Pol battery and a miniUSB connector for charging and data transfer to a computer. The maximum display value when measuring primary parameters is 99999, and the minimum value when measuring secondary parameters is 0.0001. Measurement mode – a measurement triggered by the TRI button or a command from a PC; or continuous measurement with adjustable test trigger rates of 20x/sec, 5x/sec, 2x/sec. 2+1 or 4+1 terminal configuration (with UTR-L100k-H test cables included with this device).
Thanks to its technological sophistication, the device is also suitable for professional use – when connected to a computer (PC), it creates a component sorting station based on specified tolerance parameters and can be used in production lines, laboratories, etc. Intuitive TFT LCD display, 10 brightness levels
- display range up to 99,999
- maximum accuracy 0.1%
- Ability to select components according to specified tolerance
- AC voltage measurement: 100, 120, 1000 Hz / 0–1000 Hz amplitude measurement. Voltage: 0.1 Vrms, 0.3 Vrms, 1.0 Vrms
- selection of equivalent mode (for Z <100Ω in series, for Z >10kΩ in parallel)
- automatic component identification
- built-in high-capacity Li-Pol battery: 3.7V/1800 mAh: DC +5V charging power supply
±0.25V, >1A
- operating time on a single battery charge: typically 8 hours
- Functions in data logging and statistics mode: AVG, MAX, MIN
- Audible tone when buttons are pressed: yes, can be disabled/enabled
- button lock option: yes
1, 6, automatic after shutdown minutes, or off
- Data interface: mini USB
- Data transfer rate to PC: 9600/19200/38400 baud
- Audible and visual alarm for tolerance comparison results: off, pass, fail
- Audible alarm selection: short beep, long beep, two short beeps
in case of open circuit or short circuit reset
: yes
- Setting of tolerance value from nominal: 1% to 20%, default 5%
- Component counting: all, compliant, non-compliant
Technical parameters:
- Measurement range for primary impedance parameters:
type // minimum resolution within the display range 0.001 μH to 9999.9 H // 1 / 0.1 / 0.01 / 0.001 μH
capacitance C // 0.001 pF to 99.999 mF // 1 / 0.1 / 0.01 / 0.001 / 0.001 pF at 0.001 pF resistance ///>0.0 R0.0. 99.999 MΩ // 0.0001 Ω
Total impedance Z // 0.0001 Ω to 99.999 MΩ // 0.0001 Ω
- Measurement range of secondary impedance parameters:
type // minimum resolution // 0.000 display range ////0000 display range 9.9999 // 0.0001
Quality factor Q // 0.0001 to 99999 // 0.0001
phase angle in degrees Θ degrees // -179.9° to 179.99° // 0.01°
phase angle in rad / 2 radians -Θ. 3.1416 rad // 0.001 rad
Equivalent resistance ESR // 0.01 mΩ to 999.99 Ω // 0.01 mΩ
- display: backlit TFT LCD display with a diagonal of 2.8" and a resolution of 320 x 240 pixels
-9999999 pixels. Accuracy: best 0.1%
- Component selection based on set tolerance: yes
- voltage measurement: AC 100, 120, 1000, 10000 Hz or 100 kHz
- Voltage amplitude measurement: 0.1 Vrms, Vrms, 0.1 Vrms, data transfer 0.1 Vrms, 0. Yes, after installing the software on a PC
- power supply: 1800mAh Li-Pol battery and/or 5V ±0.25V DC adapter, >1A
- automatic charging management: even when the device is switched off
- Charging and data interface: mini USB
- Operating environment: temperature 5 to 35°C, humidity ≤ 35% - Weight with/without battery: 305g / 420g
- Product dimensions (H x W x D): 192 x 93 x 44 mm
- Package dimensions: 225 x 220 x 63 mm
- Safety and EMC certification: IEC/EN 61010-1: 2010, EN 2013206, EN 61326-2-2: 2013
Contents of individual package:
- UT622C device: 1 pc UTR-001 box: 1 pc
- user manual: 1 pc
Packaging for bulk customers:
- standard quantity per box: 10 pcs
- standard box dimensions: 370 x 305 x 475 mm
- gross weight of 2 cartons: 2 kg
MANUFACTURER: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT622A LRC is a portable component tester for inductors, resistors and capacitors and their secondary properties: D (dissipation factor), Q (quality factor), Θ (phase angle in degrees), Θ (phase angle in radians) and ESR (equivalent series resistance). Component parameters are measured using AC voltage with a selectable frequency of 100, 120, 1000, 10000 Hz and a selectable amplitude of 0.1Vrms, 0.3Vrms, 1.0Vrms at a signal source output impedance of 100Ω. The highest measurement accuracy is 0.1%.
The device features an intuitive 2.8-inch TFT LCD display with ten-step adjustable backlight brightness, a built-in high-capacity 1800mAh Li-Pol battery, and a miniUSB connector for charging and data transfer to a computer. The maximum display value when measuring primary parameters is 99999, and the minimum value when measuring secondary parameters is 0.0001. Measurement mode – a measurement triggered by a TRI button or a command from a PC; or continuous measurement with adjustable test start rate of 20x/sec, 5x/sec, 2x/sec. 2 + 1 or 4 + 1 terminal configuration (following the purchase of UTR-L100k-H test cables).
Thanks to its technological sophistication, the device is also suitable for professional use – when used with a computer (PC), it creates a station for sorting components according to specified parameters and can be used in production lines, laboratories, etc.
parameters
:
- manual RLC meter for primary and secondary component parameters
- intuitive TFT LCD display, large backlit screen, 10 brightness levels
- display range up to 99,999
- maximum accuracy 0.1%
- option to select components based on AC voltage, tolerance 10, specified tolerance 10
1000 or 10000 Hz
- Selectable amplitude measurement voltage: 0.1Vrms, 0.3Vrms, 1.0Vrms
- selection of equivalent mode (for Z <100Ω in series, for Z > 10kΩ in parallel)
- automatic identification of built-in components
- high capacity Li-ion battery: 180 mAh
- Power supply + charging: DC adapter 5V ± 0.25V, > 1A
- operating time on a single battery charge: typically 8 hours
- functions in recording mode and data statistics: AVG, MAX, MIN
- beep when buttons are pressed: yes, button can be activated:
on/off switch
automatic switch-off: yes after 5, 15, 30, 60 minutes or off
- Data interface: mini USB
- data transfer rate to computer: 9600/19200/38400 baud
- Acoustic and visual alarm comparison of tolerance results: off, pass, fail
- alarm selection: short beep
- short beep, long beep
Open circuit or short circuit tester reset: yes
- setting of tolerance value from nominal: 1% to 20%, default 5%
- Component counting: all, compliant, non-compliant
Technical parameters:
- Primary impedance measurement range / minimum resolution parameters: range
inductance L // 0.001 μH to 9999.9 H // 1 / 0.1 / 0.01 / 0.001 μH
capacitance C // 0.001 pF to 99.999 mF // 1 / 0.1 / 0.01 / resistance R // 0.01 / 0.01 / 0.0001 Ω to 99.999 MΩ // 0.0001 Ω
Total impedance Z // 0.0001 Ω to 99.999 MΩ // 0.0001 Ω
- Measurement range of secondary impedance parameters // display range of the factor //
resolution parameters // minimum display range //
// 0.0001 to 9.9999 // 0.0001
Quality factor Q // 0.0001 to 99999 // 0.0001
phase angle in degrees Θ deg // -179.9° to 179.99° // 0.0001
phase angle in degrees Θ deg // -179.9° to 179.99° // 0.0001
phase angle in 0.0001 to 9.9999 -3.142 rad to 3.1416 rad // 0.001 rad
Equivalent resistance ESR // 0.01 mΩ to 999.99 Ω // 0.01 mΩ
- display: backlit TFT LCD display with a diagonal of 2.8 inches:
-999999999999999999999999999999999999999999999999999 0.1%
- component selection based on set tolerance: yes
- voltage measurement: AC 100, 120, 1000 or 10000 Hz
- amplitude measurement: 0.1 Vrms, 0.3 Vrms, 1.0 Vrms,
data transfer to PC: via PC software
- power supply: 1800mAh Li-Pol battery and (or) 5V ± 0.25V DC adapter, > 1A
- automatic charging management: even when the device is switched off
- Charging and data interface: mini USB
- operating environment: temperature 5 to 35°C, humidity <0% by weight
- 305g
- Product dimensions (H x W x D): 190 x 90 x 44 mm
- package dimensions: 225 x 220 x 63 mm
- Safety and EMC certification: IEC / EN61010-1: 2010, EN61326-2: 2013:- EN61326-2: 2013:- 2013
Contents of individual package:
- UT622A device: 1 pc
MANUFACTURER: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT60EU is a digital multimeter with a display range of 9999, enabling the measurement of true RMS voltage and current values with both automatic and manual range selection. It features 1000V rms overload protection across all ranges; the current range is protected by a 10A / 1000V tube fuse, 6.35 x 32mm. If you approach the limit values of ≥990.0V / ≥9.900A when measuring voltages and currents, an alarm will sound and ‘OL’ will be displayed when the limit values are exceeded. In addition, it allows the measurement of resistance, capacitance, temperature, frequency, duty cycle, circuit continuity and semiconductor junctions. The circuit for non-contact electric field measurement in two sub-ranges is optimised. The multimeter is equipped with a modern processor featuring a fast analogue-to-digital converter (conversion rate of 3 times per second).
The entire structure of the multimeter is fitted with a durable, double-insulated casing and has European CE certification, meeting the safety classification CAT II 1000V/CAT III 600V. The device is suitable for use in a laboratory or workshop, as well as for general electrical work. It is powered by standard 3 x 1.5V AAA batteries, which last up to 500 hours thanks to low power consumption.
Product specifications:
- backlit display range: 9999
- voltage measurement: up to ±1000V / DC / DC / AC / rms measurement: up to 1000V / DC / AC / AC rms: up to 1000V rms
- Resistance measurement: up to 99.99MΩ
- Capacitance measurement: up to 9.999mF
- Temperature measurement: with supplied K-type probe up to 250°C
- Frequency measurement: up to 9.999 MHz
- Manual measurement:
- Manual measurement: up to duty cycle/1kHz / REL / RMS / HOLD / NCV EFLo / NCV EFHi
- Circuit continuity measurement
- Semiconductor junction measurement
- Non-contact NCV measurement
- visual and audible alarms
- Voltage input protection against input overloads exceeding 10/100V
- A00V fuse
- input impedance approx. 10MΩ for DCV, then 3GΩ in the DCmV range
- Power supply: 3 x 1.5V, AAA
- Low power consumption during measurement: approx. 2 mA
- Standby current: < 30 μA
- operates on a set of batteries
- Automatic 0-hour battery indicator
- 500 hours
shutdown (sleep mode during inactivity): yes, after 15 minutes
Technical parameters:
- DC voltage measurement (input impedance is approximately 3GΩ in the DCmV range, 10MΩ in the other ranges):
(range / resolution / accuracy)
± 0V /m909 / ± 0V (0.7% + 8)
99.99 mV / 0.01 mV / ± (0.7% + 8)
999.9 mV / 0.1 mV / ± (0.5% + 3)
9.999 V / 0.001 V / 0.001 V / +95% /> ± (0.5% + 3)
0.1 V / ± (0.5% + 3)
999.9 V / 0.1 V / ± (0.5% + 3)
- Maximum input voltage: ±1000V, alarm sounds at 990.0V, ‘OL’ is displayed at >1000V.-MS overload protection
- AC voltage measurement (input impedance approx. 10MΩ):
(range / resolution / accuracy in the range 40Hz to 400Hz, sinusoidal RMS)
9.999 mV / 0.001 mV / ± 9.999 mV / 0.001 mV / ± 9.9% 0.01 mV / ± (1% + 3)
999.9 mV / 0.1 mV / ± (0.8% + 3)
9.999 V / 0.001 V / ± (0.8% + 3)
99.99 V / ± 0.1 V / 0.1 V
999.9 V / 0.1 V / ± (0.8% + 3)
- Maximum input voltage: 1000 V AC, alarm sounds at 990.0 V, ‘OL’ is displayed at > 1000 V.
- 1000 V RMS (DC/AC) overload protection (DC/AC) overload protection
-
-
Current measurement accuracy range )
999.9 μA / 0.1 μA / ± (0.8% + 3)
999.9 mA / 0.1 mA / ± (1.0% + 3)
9.999 A / 0.001 A / ± (1.0% + 3)
will sound at 9.0% + 3). ‘OL’ will be displayed at >10.00A
Overload protection: 1000V RMS, 10A fast-acting fuse
- AC current measurement:
(range / resolution / accuracy in the range 40Hz to 400Hz)
999.00% /±0.3)
999.9mA / 0.1mA / ± (1.2% + 3)
9.999 A / 0.001 A / ± (1.2% + 3)
Alarm will sound at ≥9.900 A, ‘OL’ will be displayed at load >10/0000000000000000000 protection. RMS, 10 A fast-acting fuse
- Resistance measurement:
(range / resolution / accuracy)
999.9 Ω / 0.1 Ω / ± (0.8% + 2)
9.999 kΩ / 0.001 kΩ / 0.001 kΩ / 0.001 kΩ / 0.001 kΩ / ± 9 Ω / ± 9 Ω / 0.1 Ω / ± (0.8% + 2) kΩ / 0.01 kΩ / ± (0.8% + 2)
999.9 kΩ / 0.1 kΩ / ± (0.8% + 2)
9.999 MΩ / 0.001 MΩ / ± (1.5% + 3)
99.999 MΩ / 0.001 MΩ / ± (1.5% + 3)
99.99. 5)
1000V overload protection
- Capacitance measurement:
(range / resolution / accuracy)
9.999 nF / 0.001 nF / ± (4% + 10)
99.99 nF / ± 0.001 nF / ± (4% + 10)
99.99 nF / ± 5% (1 nF / ± 5) (1 nF / ± 0 / ± 0). 999.9 nF / 0.01 nF / ± (4% + 5)
9.999 µF / 0.001 µF / ± (4% + 5)
99.99 µF / 0.01 µF / ± (4% + 5)
99.99 µF / 0.01 µF / ± (4% + 5) 9.999 mF / 0.001 mF / ± (10%)
For capacitances ≤100nF, use the REL module
1000V overload protection
- Frequency measurement:
(range/resolution/accuracy) 99.99 MHz/
Hz. 0.01 Hz to 0.001 MHz / ± (0.1% + 5)
1000 V RMS (DC/AC) overload protection
- Duty cycle measurement for square waves ≤10 kHz:
(range / resolution / accuracy)
9.1% / ± 0.9% / 9.1% / 0.001 MHz / ± (0.1% + 5) 5)
Overload protection 1000 V RMS (DC/AC)
- Diode test:
voltage across terminals without load approximately 3.3 V
voltage drop across a good silicon junction is 0.5 to 0.8 V
measurement resolution 0.001 V
/>
/>
a beep will sound if the resistance is less than 30 Ω
Overload protection 1000 V RMS (DC/AC)
- Temperature measurement:
(range / resolution / accuracy)
°C /°C / ± 0°C /°C ± 0°C 4°C
0°C to 100°C / 1°C / ± (1.0% + 5)
100°C to 1000°C / 1°C / ± (2.0% + 5)
-40°F to 32°F / 1°F / ± 2°F /°F / ±/> 1°F / ± (1.5% + 5)
>212°F – 1832°F / 1°F / ± (2.5% + 5)
The K-type thermocouple accessory is only suitable for temperature measurements below 250°C/482°F. Features:
- Operating ambient temperature: 0°C to 40°C
- Storage temperature: -10°C – 50°C (14°F – 122°F)
- Operating relative humidity: ≤75% (0°C to 30°C), ≤50% (30°C to operating altitude)
- 0°C at 2000m
- operating environment: indoor use
- EMC resistance: for radio frequency field 1V/m
- power supply: 3 x 1.5V, AAA
- LCD display: 73 mm x 50 mm with backlight, 2 brightness levels, or off
- product colour: red and grey: 20 g
- Product weight: approx. 400 g (including batteries)
- Product dimensions: 169 x 81 x 46 mm
Contents of individual package:
- UT60EU multimeter with storage case: 1 pc
- 1.5V AAA battery: 3 pcs. /250V (6.35 x 32 mm) - in the device: 1 pc
- Test leads with CAT II 1000V/CAT III 600V category tips: 1 pair
- temperature probe: 1 pc
- user manual: 1 pc
Standard packaging:
Qty
- Standard carton dimensions: 420 x 320 x 300 mm
- Manufacturer: UNI-TREND
-
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT595 Multifunctional Electrical Tester
The UT 595 is a universal measuring and testing device for inspecting electrical equipment. It allows automatic testing of circuit breaker trip times, measurement of leakage currents, measurement of earth loop impedance and earth continuity, measurement of insulation resistance, measurement of AC voltage frequency, and measurement of DC and AC voltage, as well as phase sequence in three-phase systems. It features a durable casing and new analogue, digital and microprocessor circuits.
This device has been designed, manufactured and tested in accordance with the IEC 61010 safety standard (Safety requirements for electrical equipment) in the CAT III 300 V overvoltage category. It fully complies with the ČSN EN 61557 standard for insulation and transient resistance measurement.
The UT595 is the ideal tool for the maintenance, testing and inspection of electrical protection components for every electrician and inspection technician.
Product specifications:
- backlit LCD display:
- backlit LCD display dimensions: 995:00, 125 mm × 37 mm
- The display shows: operating modes, values, units and symbols
- function switch: 15-position rotary switch
- Range switching: automatic
- current measurement of current protectors: types 10mA, 30mA, 100mA, 300mA, phase shift angle 3000mA
- option to change the phase of 300mA by 0° or 180° to detect the fastest response time of the protective equipment
- optional half-wave/full-wave test mode and countdown timer (30 sec)
- automatic circuit breaker tests: sequential switching of leakage currents, smooth increase of leakage current up to the circuit breaker
- storage in memory of the impedance value measured in the loop
- Test (PFC) / short-circuit current (PSC): in the range 0.05Ω to 2000Ω
- earth continuity measurement: in the range 0.01Ω to 200Ω
- Insulation resistance measurement: 0.05 MΩ to 1 MΩ at test voltage 250 V / 500 V AC / AC<br//500 V: frequency from 20 Hz to 100 Hz
- AC and DC voltage measurement: 0 V to 440 V, automatic AC/DC/polarity resolution
- Phase sequence measurement: phase sequence indication, direction of rotation
- Power supply: 6 x 1.5V AA alkaline batteries
- The automatic calibration protocol must be ordered separately
- Must be ordered separately. Device
- Key lock
- An indispensable assistant for every inspection technician
Technical specifications:
- Circuit breaker measurement
Measurement current selection I: 10mA / 30mA / 100mA / 300mA / 300mA
voltage 220V ± 10%, frequency 45Hz to 65Hz
Current measurement accuracy at 220V AC: ± (10% + 2)
Automatic circuit breaker test with current I: 50%, 100%, 200%, 500% of the trip current, at 0% trip current, at Δn trip current interval: 2000 ms
Time measurement range at current 1 * I, Δn: 0 to 500 ms (with countdown function)
Time measurement interval at current 1 * I, Δn: 0 to 300 ms
Time measurement interval at current 2 * I, Δn: 0m0 (with countdown function) to <20:0m0 Measurement range at current 2 * I, Δn: 0 to 150 ms
Time measurement range for current 5 * I, Δn: 0 to 40 ms
Time measurement accuracy: ± (5% + 5)
option to change phase angle 0° / 180° / 180° / 180° short-circuit phase current measurement (PSC)
Operating voltage: 220V ± 10% / 195V to 440V / 45Hz to 65Hz
Current and time measurement: 20A / 20ms
Measurement ranges: 0.05Ω to 1.99Ω; 2.0Ω to 19.9Ω; 20Ω to 2000Ω
Minimum resolution: 0.01Ω
Short-circuit current: 0kA to 26kA
Accuracy: ± (5% + 5)
- Earth continuity measurement
Nominal measurement voltage: approx. 5V
Measurement current: more than 200mA
Measurement range: 0.01Ω to 200Ω
Accuracy in the range 0.01Ω to 200Ω: ± (2% + 5)
- Insulation resistance measurement
Insulation voltage test rate
± 20 V: ± 10% or 500 V ± 10% or 1000 V ± 10%
Measurement range: 0.05 to 250 MΩ, or 0.05 to 500 MΩ, or 0.05 to 1000 MΩ
Nominal measurement current at 250kΩ, or 0.5A at 500kΩ, or 0.5A at 50kΩ: 1.1 mA
short-circuit current: <1.8 mA
Measurement accuracy in the range 0.05 MΩ to 1000 MΩ: ± (5% + 5)
- AC and DCV voltage measurement
AC measurement range: 40 V to ± 40 V DC
Measurement range: 440 V (50/60 Hz)
Resolution: 1 V
Measurement accuracy: ± (2% + 3)
Voltage measurement in the <10V range: for information purposes only
- Frequency measurement
Measurement range:
measurement range:
resolution: 200 Hz
1 Hz
Measurement accuracy: reference only
- Phase sequence measurement
For voltage: Three-phase AC 100 V to 440 V / 45 to 65 Hz
Phase sequence: L1 → L2 → L3 forward rotation; L1 → L2 → L3 reverse rotation
Phase voltage drop: Phase drop in L1, L2 or L3 will be displayed on the LCD screen
General parameters:
- automatic range selection function: yes
- low battery indication: yes, symbol "" on display
, "overload" symbol: yes (indication "out of range"): display
- Power supply: 1.5V AA batteries, 6 pcs
- Current consumption: standby approx. 10mA, approx. 50mA at 1000V
- LCD display dimensions: 125 × 37 mm
- operating environment: temperature 0°C to +40°C, humidity max. 85% RH
- Declared accuracy is guaranteed in the following environment: temperature 23 ± 5 °C, humidity: 45–75% RH
- Storage conditions: temperature -20 °C to +60 °C, humidity max. 90% RH
- Weight: 1 kg (including batteries)
- device dimensions: 210 x 90 x 175 mm
- Device colour: red and grey
Contents of individual package:
- UT595 device: 1 test lead
, 1 × 1)
- 1.5V AA alkaline battery: 6 pcs
- carrying case: 1 pc
- user manual: 1
Wholesale packaging:
- standard quantity per box: 4 pcs
- Standard box dimensions: 510 × 300 mm, total weight 15 kg
Manufacturer: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT60BT is a digital multimeter with a display range of 9999, allowing for the measurement of true RMS values of voltages and currents with both automatic and manual range selection. It features 1000V rms overload protection across all ranges; the current range is protected by a 10A / 1000V tubular fuse, 6.35 x 32mm. If you approach the limit values of ≥990.0V / ≥9.900A when measuring voltages and currents, an alarm sounds and the character ‘OL’ is displayed when the limit values are exceeded. It also allows the measurement of resistance, capacitance, temperature, frequency, duty cycle, circuit continuity and semiconductor junctions. The circuit is optimised for non-contact electric field measurement in two sub-ranges. The multimeter is equipped with a modern processor featuring a fast analogue-to-digital converter (3 conversions per second) and transmits measured values via Bluetooth using the low-energy wireless technology 802.15.4 to a mobile phone or tablet with the Connect app installed.
The entire multimeter housing is fitted with a durable, double-insulated casing and has European CE certification, meeting the safety classification CAT II 1000V / CAT III 600V. The device is suitable for use in a laboratory or workshop, as well as for general electrical work. It is powered by three standard 1.5V AAA batteries, which, thanks to their low power consumption, last up to 500 hours.
Product specifications:
- backlit display range: 9999
- voltage measurement: up to ± 1000V / DC / AC to ± rms current measurement / DC: up to ± rms AC rms
- Resistance measurement: up to 99.99MΩ
- Capacitance measurement: up to 9.999mF
- Temperature measurement: up to 250 °C with the supplied K-type probe
- Frequency measurement: up to 9.999 MHz
- Manual measurement:
- Automatic measurement:
- Manual measurement:
Hz / REL / RMS / HOLD / NCV EFLo / NCV EFHi
- Circuit continuity measurement
- Semiconductor junction measurement
- Non-contact NCV measurement
- visual and audible alarms
- Bluetooth for transmitting measured data
- input overload protection
- 0–10 A input current via fast-acting fuse
- Input impedance approx. 10MΩ for DCV, in the DCmV range then 3GΩ
- power supply: 3 x 1.5V, AAA
- Low power consumption during measurement: approx. 2 mA
- Sleep mode current consumption: <30 μA
- Battery life: 500 hours (automatic battery shut-off)
- Automatic battery shut-off indicator: 500 hours (sleep mode): yes, after 15 minutes
Technical parameters:
- DC voltage measurement (input impedance is approximately 3GΩ in the DCmV range, 10MΩ in other ranges):
(range / resolution / accuracy)
9.9090 % (± 9.90 mV / mV / ± 9.90 mV) + 8)
99.99 mV / 0.01 mV / ± (0.7% + 8)
999.9 mV / 0.1 mV / ± (0.5 % + 3)
9.999 V / 0.001 V / ± (0.5 % / 9 V / ± (0.5 % + 3)
(0.5% + 3)
999.9 V / 0.1 V / ± (0.5 % + 3)
- Maximum input voltage: ± 1000 V, alarm sounds at 990.0 V, ‘OL’ is displayed at >1000 V.
- Overload protection 1000 V AC / AC/AC
/>
Voltage measurement (input impedance approx. 10 MΩ):
(range / resolution / accuracy in the range 40 Hz to 400 Hz, RMS sine wave)
9.999 mV / 0.001 mV / ± (1 % + 3)
99.99 mV //3.01 mV //> 999.9 mV / 0.1 mV / ± (0.8 % + 3)
9.999 V / 0.001 V / ± (0.8 % + 3)
999.9 V / 0.1 V / ± (0.8 % + 3)
- Maximum input voltage 0 V, alarm 0 V, 0.10 V AC; ‘OL’ is displayed at >1000 V.
- Overload protection 1000 V RMS (DC / AC)
- DC current measurement:
(range / resolution / accuracy)
999.9 μA / 0.1 μA / ± (0.8% / mA) / 90% + 390 mA. ± (1.0% + 3)
9.999 A / 0.001 A / ± (1.0% + 3)
- Alarm sounds at ≥9,900 A, ‘OL’ is displayed at >10.00 A.
- Overload protection: 1000 V RMS,
measurement:
(range / resolution / accuracy in the range from 40 Hz to 400 Hz)
999.9 μA / 0.1 μA / ± (1.0% + 3)
999.9 mA / 0.1 mA / ± (1.2% + 0.1 mA / ± (1.2% + 3). (1.2% + 3)
- Alarm sounds at ≥9,900 A, ‘OL’ is displayed at >10,000 A.
- Overload protection: 1000 V RMS, 10 A fast-acting fuse
- Resistance measurement:
(range / resolution //>09 accuracy)
Ω / ± (0.8% + 2)
9.999 kΩ / 0.001 kΩ / ± (0.8% + 2)
99.99 kΩ / 0.01 kΩ / ± (0.8 % + 2)
999.9 kΩ / ± 0.1 kΩ / ± 0.1 kΩ / ± (0.1 kΩ)
9.999 MΩ / 0.001 MΩ / ± (1.5 % + 3)
99.99 MΩ / 0.01 MΩ / ± (2.0 % + 5)
- Overload protection 1000V
- Capacitance measurement:
Accuracy range nF 9 /
0.001 nF / ± (4% + 10)
99.99 nF / 0.01 nF / ± (4% + 5)
999.9 nF / 0.01 nF / ± (4% + 5)
9.999 µF / 0.01% / ± 5)
99.99 µF / 0.01 µF / ± (4% + 5)
999.9 μF / 0.1 μF / ± (4% + 5)
9.999 mF / 0.001 mF / ± (10%)
- For Rn-type capacitors, use Rn capacitors
1000 V overload protection
- Frequency measurement:
(range / resolution / accuracy)
99.99 Hz to 9.999 MHz / 0.01 Hz to 0.001 MHz / ± (0.1% + 5)
- Overload protection 0.00 V RMS (0.00 V DC) AC)
- Duty cycle measurement for square waves ≤10 kHz:
(range / resolution / accuracy)
0.1% to 99.9% / 0.1% / ± (3% + 5)
Overload protection 1000 V DC -
/>
test:
voltage across terminals without load approx. 3.3 V
voltage drop across a good silicon junction is 0.5 to 0.8 V
measurement resolution 0.001 V
- Circuit continuity test:
the buzzer will not sound if the resistance is lower than the sound
30 if the resistance is less than 30 Ω
Overload protection 1000V RMS (DC / AC)
- Temperature measurement:
(range / resolution / accuracy)
-40 °C to 0 °C / 1 °C / ± 4 °C
0 °C to 10 °C / ± 100 °C / (±5 °C)
100 °C to 1000 °C / 1 °C / ± (2.0% + 5)
-40 °F to 32 °F / 1 °F / ± 5 °F
> 32 °F to 212 °F / 1 °F / ± 5 °F / ± 2% / ± 5 °F
1832 °F / 1 °F / ± (2.5% + 5)
The K-type thermocouple included as an accessory is only suitable for measuring temperatures below 250 °C / 482 °F.
1000 V RMS (DC / AC) overload protection
General operating temperature:
> 40 °C
- storage temperature: -10 °C to 50 °C (14 °F to 122 °F)
- Operating relative humidity: ≤75% (0 °C to 30 °C), ≤50% (30 °C to 40 °C)
- Operating altitude: 0 m to 20 °C
- EMC resistance: for radio frequency field 1V/m
- Power supply: 3 x 1.5V, AAA
- Product colour: red and grey
- Net product weight: 290 g
- Product weight: approx. 400 g (including batteries)
- Product dimensions: 16 x 84 mm
Contents of individual package:
- UT60BT multimeter with storage case: 1 pc
- 1.5V AAA battery: 3 pcs
- F1 fuse: F 10A / 250V (6.35 x 32mm) - Category II test lead set:
1 pc 1000V / CAT III 600V: 1 pair
- temperature probe: 1 pc
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 20 pcs
- standard box dimensions: 420 x 03>
-
- Manufacturer: UNI-TREND
-
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT572 Earth Resistance Tester
This product comes with a 3-year warranty. The UT572 is a smart device for measuring earth resistance and soil resistivity (specific earth resistance). The device is widely used in the design and testing of earthing systems for new electrical installations and lightning protection in construction, industry, substations, telecommunications, etc. (ρ), voltage and frequency of induced interference signals Ust and Fst.
The device features a new design with a large, backlit multifunctional display. It has a durable, double-insulated and reinforced casing.
This device has been designed, manufactured and tested in accordance with safety standards IEC 61010 (Safety requirements for electrical equipment) in the CAT III 300 V overvoltage category, EN 61010-2-033, EN 61010-2-033, EN 61010-031, EN 61010-031.Product parameters.
:
- maximum display: 9999
- backlit multifunctional LCD display with dimensions: 125 mm × 37 mm
- display shows: operating modes, values, units and symbols
- Function and range selection: 8-position rotary switch
- soil resistivity measurement method (ρ, 2-wire) 4-wire
- earth resistance test: RK, RH, RS
- display of interference voltage Ust: up to 50V / AC / DC
- display of interference frequency Fst: in the range from 40 to 500Hz
- test signal frequency: 94Hz and/or 128Hz: probe spacing
128-z: 40 m
- memory storage: up to 20 measurement sets
- Power supply: 8 x 1.5 V AA alkaline batteries
- battery status display: yes, if it drops below 9.5 V, replace the batteries
- automatic switch-off on inactivity: yes, switches off after overcharging
- protection
Technical parameters:
Earth resistance measurement (Re)
Measurement range / resolution / accuracy (Re)
4Ω / 0.01Ω / ± (3% + 15)
40Ω / 0.1Ω / ± 0.1Ω / ± 0.1Ω / ± 0.1Ω / ± (3%/1Ω / 5) (3% + 5)
4kΩ / 0.01kΩ / ± (3% + 5)
40 kΩ / 0.1 kΩ / ± (3% + 5)
Measurement of soil resistivity (ρ)
in the ranges: 4Ω, 40kΩ, Ω, 404kΩ, Ω, 4Ω, max. 1000kΩm
Measurement accuracy (ρ) depending on the test result Re: ρ = 2 × π × L × Re
Measurement of interference signals
amplitude / resolution / measurement accuracy range (Ust)
1 to 50Vrms / 1V / ±>resolution /frequency / 1V / ±) measurement accuracy (Fst)
40 Hz to 500 Hz / 1 Hz / ± (1% + 2)
Other parameters:
- backlit multifunctional LCD display with dimensions: 125 × 37 mm
- test signal frequency and test signal frequency range: or 94H/2-Hz probes: 1m to 40m
- memory storage: up to 20 measurement sets
- Overload protection: 220V AC for 10s between terminals E-S, E-H
- insulation resistance between PCB circuits and casing: ≥ 50MΩ (1000V) 3540V / AC 50 / 60Hz for 5s, spark-free
- power supply: 8 x 1.5V AA alkaline batteries
- automatic shut-off on inactivity: yes, after 5 minutes
- low battery indication: yes, at ≤ 9.5V
0 °C to: operating temperature, 40°C max. 80% RH, n.m.v. ≤ 2000
- Storage conditions: temperature from -20 °C to +60 °C, humidity ≤ 75% RH
- Device dimensions: 210 x 175 x 90 mm
- Weight: 1.1 kg (including batteries)
- device colour: red and grey/
Packaging:
- UT572 device: 1 pc
- Green precision test lead, 5 m with alligator clip: 1 pc
- yellow precision test lead, 10m with alligator clip: 1 pc
- Red precision test lead, 20m with alligator clip: 1 precision alligator clip: 1-2 alligator test leads: 1-2 black clips: 1 pc
- red precision test lead, 40m with alligator clip: 1 pc
- standard test leads with crocodile clips: 2 pcs
- earth probe (probe) approx. 20 cm long: 4 pcs
- 1.5V AA alkaline battery: 8 pcs
- case: 1 pc
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 2 pcs
- standard box dimensions: 30 x 347 mm (CBM)
- standard total box weight: 14kg
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT526 Electrical Tester
The UT526 is a universal measuring and testing device for inspecting electrical equipment. It allows for the testing of switchgear, measurement of earth loop resistance, measurement of insulation resistance, measurement of AC voltage frequency, and measurement of DC and AC voltage. The device features a newly designed, durable housing with new analogue, digital and microprocessor circuits.
This device has been designed, manufactured and tested in accordance with the IEC 61010 safety standard (Safety requirements for electrical equipment) in the CAT III 600 V overvoltage category. It fully complies with the ČSN EN 61557 standard for insulation and transient resistance measurement.
Product parameters:
- maximum display: 9999
- display dimensions: 71 x 34 mm
- display shows: operating modes, value switching units and automatic symbols:/>-
measurement of circuit breaker trip time: types 10mA, 30mA, 100mA, 300mA
- earth loop measurement: in the range 0.01Ω to 2000Ω
- insulation resistance measurement: 0.05 MΩ to 1 MΩ when measuring AC frequency
- 0.05 MΩ to 1 MΩ - within the voltage measurement range
- 2000Ω 100 Hz
- AC and DC voltage measurement: 0 V to 440 V
- Power supply: 6 x 1.5V AA alkaline batteries
- An indispensable tool for every inspection technician
- Calibration certificate must be ordered separately
- Outstanding value for money
Technical specifications
:
Circuit breaker trip time measurement
Current measurement: 10mA / 30mA / 100mA / 300mA
Measurement voltage: 220V ± 10%, frequency 45Hz to 65Hz
Measurement accuracy: ± 20V AC: ± 20V 2)
Time measurement range at 10mA current: 0 to 2000msec
Time measurement range at 30mA current: 0 to 500msec
Time measurement range at 100mA current: 0 to 300ms
Time measurement range at a measurement current of 300msec/30): 300msec > measurement current
Accuracy: ± (5% + 2)
Earth loop measurement
Nominal voltage measurement: approx. 5.0 V
Measurement current: >200 mA, for <2 Ω
Earth loop resistance measurement range: 0.01Ω to 2000Ω
Measurement accuracy: 0.01Ω to 2000Ω ± (2% + 5)
Insulation voltage/resistance measurement range: voltage/insulation test 250 V ± 10% or 500 V ± 10% or 1000 V ± 10%
Measurement range: 0.05 to 200MΩ or 0.05 to 300MΩ or 0.05 to 500MΩ
Rated measurement resistance: 1500 kΩ or 2500 kΩ Measurement current: 1500 kΩ 0.9 mA to 1.1 mA
Short-circuit current: <1.8 mA
Measurement accuracy in the range 0.05 MΩ to 500 MΩ: ± (5% + 5)
AC and DCV voltage measurement
AC and DC measurement range:
Measurement range:
DC ± 440 0 to 440V (50 / 60Hz)
Resolution: 1V
Measurement accuracy: ± (2% + 3)
Voltage measurement in the <10V range: reference only
Frequency measurement
Measurement range:
resolution:
200 Hz 1 Hz
Measurement accuracy: for reference only
General parameters:
- low battery indicator: yes, symbol “” on display
- Overload indication (out of range): yes, “OL” symbol on display
- Power supply: 1.5V DC 10mA, approx. 50mA at 1000V range
- LCD display dimensions: 71 x 34 mm
- Operating environment: temperature 0 to +40 °C, humidity max. 85% RH
- Specified accuracy is guaranteed in the following environment: temperature 23 ± 5 °C, humidity: 45–75% RH
- Storage conditions: temperature -20 °C to +60 °C, humidity max. 90% RH
- device dimensions: 160 x 100 x 71 mm
- Device colour: red and grey
- device weight: 380g
- Weight: 0.7 kg (including batteries)
Contents of individual package:
device:
battery:
1.5V, AA: 6 pcs
- test leads with alligator clips: 3 pcs (red, green, blue)
- case: 1 pc
- user manual: 1 pc
Wholesale packaging:
- standard quantity per standard box: 104 x 40 pcs.
- 40 pcs. 180 mm (0.063 CBM)
- total. Standard box weight: 12.8 kg
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
The UT513C 5 kV insulation resistance tester is a digital high-voltage insulation resistance tester designed with multiple voltage ranges, including 250 V, 500 V, 1000 V, 2500 V and 5000 V. It is an ideal measuring instrument for the electricity, telecommunications, meteorology, engine room, oil field, electromechanical installations and maintenance departments of industrial and mining enterprises.
Product parameters:
- Output voltage range: up to 5kV
- PI/DAR measurement
- Short-circuit current measurement
- Automatic display of leakage current
- Step voltage: 10% of the measurement range
->-
-/-
high voltage alarm
- automatic discharge
- high voltage output alarm function
- data storage: 999 sets
- PC software analysis: via USB cable
- rechargeable lithium battery 14.8V, 5200mAh
- Overvoltage category: CAT IV 600V
-
-
-
Test voltage: 500V / 1000V / 1500V / 2500V / 5000V
- Capacitance test: 0.01uF ~ 15.0uF
- output voltage (rated / voltage range:
250V, / 250V, / 270V
500V / 250V, 300V, 350V, 400V, 450V, 500V, 550V, 600V
1000V / 500V, 600V, 700V, 800V, 900V, 1000V, 1000V, 1000V 1200V
2500V / 1250V, 1500V, 1750V, 2000V, 2250V, 2500V, 2750V, 3000V
5000V / 2500V, 3000V, 3000V, 3000V, 3000V, 3000V 2000 V
Stepwise output voltage range (evaluation) Shift 10% of each range at a time and adjust the voltage range to 50%–120% of each range
display accuracy: ± (10% of reading + 10V)
Output accuracy: ±(0%~20%)
Voltage: >-0% / ±(3%+5)
- AC voltage: 30 ~ 750 V AC / 50Hz/60Hz ±(3%+5)
- Current: 0.01 nA ~ 5.0 mA
- Short-circuit current: approx. Dielectric absorption ratio (DAR): automatic display
- Timing measurement
- Resistance comparison
- Monitoring function: monitoring of the measured object’s voltage and discharge status after testing
- Timing range: 0 s ~ 99 m and 59 s
- storage function: 999 sets USB/Bluetooth for connection to PCs:
- Yes
- low battery indicator
- Auto-off (approx. 15 minutes)
- Dimensions: 238 x 166 x 90.5 mm (W x H x D)
- Power supply: 14.8V, 5200 mAh lithium battery
- product colour: black and red
- Product weight
including 180,000 battery)
Accessories:
- test leads (red, black, green: 1 of each) 3 pcs
- Lithium battery charger
- Lithium battery (14.8V, 5200mAh)
- USB cable 1 pc
- carrying strap UNI-1-BUC
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT513B 5 kV insulation resistance tester is a digital high-voltage insulation resistance tester designed with multiple voltage ranges, including 250 V, 500 V, 1000 V, 2500 V and 5000 V. It is an ideal measuring instrument for departments in the electrical power, telecommunications, meteorology, engine room, oil field, electromechanical installations and maintenance sectors, as well as industrial and mining enterprises.
Product parameters:
- Output voltage range: up to 5kV
- PI/DAR measurement
- Short-circuit current measurement
- Automatic display of leakage current
- Step voltage: 10% of the measurement range
- Range measurement
- timer
- high voltage alarm
- automatic discharge
- high voltage output alarm function
- data storage: 999 sets
- PC software analysis: via USB cable
- rechargeable lithium battery 14.8V, 5200mAh
- overvoltage category: CAT IV/6/00V
Parameters:
- Test voltage: 500V / 1000V / 1500V / 2500V / 5000V
- Capacitance test: NO
- Output voltage (nominal / voltage range:
250V / 250V, 205V, 205V
250V, 300V, 350V, 400V, 450V, 500V, 550V, 600V
1000V / 500V, 600V, 700V, 800V, 900V, 1000V, 1000V, 1000V, 500V, 1100V, 1100V, 1100V / 1250V, 1500V, 1750V, 2000V, 2250V, 2500V, 2750V, 3000V
5000V / 2500V, 3000V, 3500V, 4000V, output voltage
display accuracy: ± (10% of reading + 10V)
Output accuracy: ±(0%~20%)
- DC voltage: 30 ~ ~ ± 5 V DC/- ± 0% voltage: 30 ~ 750 V AC / 50Hz/60Hz ±(3%+5)
- Current: 0.01nA ~ 3.5mA
- Short-circuit current: approx. 3.5mA
- Polarisation index (PI): automatic (polarisation index
): display
- Timing measurement
- resistance comparison
- monitoring function: monitors the voltage of the measured object and the discharge status after testing
- Timing range: 0 s ~ 99 min 59 s
- storage function: 999 sets
- USB for connection to a PC -> NO
-> low battery indication
- Auto power off (approx. 15 minutes)
- Dimensions: 238 x 166 x 90.5 mm (W x H x D)
- Power supply: 14.8V, 5200 mAh lithium battery
- product colour: black + red
- product weight: 1800 g (battery)
Accessories:
- test leads (red, black, green: 1 of each) 3 pcs
- lithium battery charger
- lithium battery (14.8V, 5200mAh)
- USB cable 1 pc
- carrying strap
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT513A Insulation Resistance Tester
This product comes with a 3-year warranty. SPECIFICATIONS:
Insulation resistance: 0.5 MΩ ~ 1000 GΩ
- Best accuracy: +/- (3%+5)
Test voltage: 5000V // 2500V/5000V
- Best accuracy: 0 ~ 20%
DC voltage: 600V
- best accuracy: +/- (2%+5)
AC voltage: 600V
- best accuracy: +/- (2%+5)
AUTOMATIC OPERATION
Engagement
Short-circuit current: < 1.8 mA
Data logging: 18
Standby mode
Polarisation index (PI)
Dielectric absorption rate (DAR)
Timer Approx.: 15 minutes
Compare
Battery display
White display
Backlight
White light range
Warning
USB
Max. Display: 9999 (123 x 58 mm)
Analogue bar graph
GENERAL FEATURES
Power: 8 x 1.5V alkaline batteries (LR14)
Product dimensions: 202×155×94 mm
Product weight: 2 kg,
ACCESSORIES:
batteries, manual, toolbox, USB cable
/en/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT512E 2.5 kV insulation resistance tester is a high-voltage digital insulation resistance tester, designed with multiple voltage ranges, including 250 V, 500 V, 1000 V and 2500 V. It is an ideal measuring instrument for the electrical power, telecommunications, meteorology, machine shop, oilfield, electromechanical installations, and maintenance and power supply departments of industrial and mining enterprises. leakage current
- Step voltage: 10% of the range
- high voltage alarm
- automatic discharge
- Data storage: 999 sets
- PC software analysis: via USB cable
- Overvoltage category: CAT IV 600V
Technical/test parameters: //>-0 1000V / 1500V / 2500V
- capacitance test: 0.01uF ~ 2.0uF / ±(15%+3)
- Low resistance test: 0.1Ω ~ 600Ω / ±(2%–+10% of voltage)/rated voltage
250V / 350V, 275V, 300V
500V / 300V, 350V, 400V, 450V, 500V, 550V, 600V
1000V / 500V, 800V, 800V, 800V, 900V, 1000V, 1100V, 1200V
2500V / 1250V, 1500V, 1750V, 2000V, 2250V, 2500V
Output voltage step voltage range (rating) Set the voltage range to 0% each time and adjust each voltage range from 0% to 50%–120% of that range
display accuracy: ± (10% of reading + 10V)
Output accuracy: ±(0%–20%)
- DC voltage: 30 ~ 1000 V DC / ±(3%+5)
- AC voltage: 70 ~: 50Hz/60Hz ±(3%+5)
- Current: 0.01nA ~ 5mA
- Short-circuit current: approx. 5mA
- Polarisation index (PI): automatic display
- Dielectric absorption ratio (DAR) monitoring: automatic measurement
/>
- Resistance comparison function: monitors the voltage of the measured object and the discharge status after testing
- Timing range: 0 s ~ 99 m and 59 s
- Storage function: 999 sets
- USB for connection to a PC
- low battery indicator
- Auto power off
- Dimensions: 163 x 9 mm (L x W x D)
- power supply: 14.8V, 5200 mAh lithium battery
- Product colour: black and red
- product weight: 1800 g (including battery)
Accessories:
- Test cable (red, black, green): 1 lithium battery
- 1 charging unit
(Output: 16.8 V DC, 2 A)
- Lithium battery (14.8 V, 5200 mAh)
- 1 USB cable
- Carrying strap 1 pc
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT512D 2.5 kV insulation resistance tester is a high-voltage digital insulation resistance tester, designed with multiple ranges, including 250 V, 500 V, 1000 V and 2500 V. It is an ideal instrument for the electrical power sector, the telecommunications sector, the oil industry, telecommunications workshops, the meteorological industry, and the electromechanical and power supply installation and maintenance departments in industrial and mining companies.
Product parameters:
- Output voltage range: Up to 2.5 kV
- PI/DAR measurement
- Short-circuit current measurement
- Automatic display of high-voltage leakage current
- 1/0% voltage range
- Alarm
- automatic discharge
- data storage: 999 sets
- PC software analysis: via USB cable
- Overvoltage category: CAT IV 600V
Technical parameters:
- test voltage: 500V / 1000V test capacity: ////12500V test:
NO
- Low resistance test: NO
- Output voltage (rated / voltage range:
250V / 350V, 275V, 300V
500V / 300V, 350V, 400V, 450V, 500V,
1000V / 500V, 600V, 700V, 800V, 900V, 1000V, 1100V, 1200V
2500V / 1250V, 1500V, 1750V, 2000V, output voltage, voltage range (evaluation) Shift 10% of each range each time and adjust the voltage range to 50% ~ 120% of each range
display accuracy: ± (10% of reading + 10V)
output accuracy: ±(0%~20%)
- DC voltage: 30 ~ V+/10 ±(V+10 V) AC voltage: 30 ~ 750 V AC / 50Hz/60Hz ±(3%+5)
- Current: 0.01 nA ~ 3.5 mA
- Short-circuit current: approx. 3.5 mA
- Polarisation index (PI): automatic (polarisation index)
p. display
- Timing measurement
- resistance comparison
- Monitoring function: monitors the voltage of the measured object and the discharge status after testing
- Timing range: 0 s ~ 99 m and 59 s
- storage function: 999 sets
- USB for automatic connection to a computer
-/low battery indicator
-/> power off
- Dimensions: 238 x 166 x 90.5 mm (W x H x D)
- Power supply: 8 x 1.5V alkaline batteries (LR14)
- product colour: black + red
- product weight: 1800 g (including batteries)
, test leads:
-, black, black for each) 3 pcs
- USB cable 1 pc
- carrying strap 1 pc
Manufacturer: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT512 Insulation Resistance Tester
This product comes with a 3-year warranty. SPECIFICATIONS:
Insulation resistance: 0.5 MΩ ~ 100 GΩ
- Best accuracy: +/- (3%+5)
Test voltage: 1500V / 1000V / 2500V
- best accuracy: 0 ~ 20%
DC voltage: 600V
- best accuracy: +/- (2%+5)
AC voltage: 600V
- best accuracy: +/- (2%+5)
- best accuracy: +/- (2%+5)
AC voltage: 600V
- Best accuracy: +/- (2%+5)
Operating current: < 1.8 mA
Data logging: 18
Standby mode
Polarisation index (PI)
Dielectric absorption (DAR)
Timer Approx.: 15 minutes
Compare
Battery display
White display backlight
White display
War
Great War
V/B>
Max. Display: 9999 (123 x 58 mm)
Analogue bar graph
GENERAL FEATURES
Power: 8 x 1.5V alkaline batteries (LR14)
Product dimensions: 202×155×94 mm
Product weight: 1.>
Includes: clamps, batteries, manual, toolbox, USB cable, CD, power adapter
/ro/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT511 Insulation Resistance Tester
This product comes with a 3-year warranty. SPECIFICATIONS:
Insulation resistance: 500 kOhm ~ 10 GOhm
- Best accuracy: +/- (3%+5)
Low resistance:
000 Ohm Testing:
000 250V / 500V / 1000V
- best accuracy: 0 ~ 20%
DC voltage: 1000 V
- best accuracy: +/- (1%+3)
AC voltage: 750 V
- best accuracy: +/- (SPIAL%>
FUNCTIONS:
Automatic adjustment
Short-circuit current (< 2 mA)
Data logging (18)
Standby mode
Polarisation index (PI)
Dielectric absorption (DAR)
Timer (approx. 30 minutes)
Backlight
/>Backlight
/>Compare
/>Backlight display. Display: 9999 (123 x 58 mm)
Overrange and high voltage warning
Analogue bar graph
GENERAL FEATURES:
Power: 8 x 1.5 V batteries (R14)
Product dimensions: 202 x 155 x 94 mm
Product weight: 2 kg
ACCESSORIES: alligator clips, batteries, manual, toolbox
/en/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty.
The UT503PV digital insulation resistance tester can be used to measure insulation resistance with a photovoltaic power supply (maximum: 1000V DC) and conventional insulation resistance (without power supply), and to automatically identify AC/DC voltage. It has several functions, including: measuring photovoltaic insulation resistance without a solar panel during a power cut/short circuit or at night, voltage grading, Bluetooth transmission, automatic discharge, high-voltage warning, remote-controlled test lead operation, etc. Parameters:
- High output voltage: DC 1000 V
- UTD test under voltage: DC 1000 V
- Insulation resistance (PV+IR): 4000 MΩ
- Voltage measurement: 1000 V DC & 600 V AC
- Automatic overload stage measurement
- Time
- Comparison function (IR)
- high voltage alarm
- Data communication: USB cable + Bluetooth app
- lithium battery
- analogue bar graph
- high-quality backlit display
- portable and convenient
- certification: CE, cETLus
: technical parameter/photovoltaic
resistance (PV)
- Conventional insulation resistance measurement
- AC/DC voltage testing (VDC/VAC)
- Insulation resistance range: 0.125 MΩ – 4000 MΩ
- rated voltage for conventional output (conventional insulation resistance: 4 positions, 50 V, 120 V, 120 V, 120 V) V
- rated voltage for photovoltaic power (photovoltaic insulation resistance: 2 positions): 500 V, 1000 V
- short-circuit current: <1.5 mA
- step in each range: 10% of the rated voltage
- specifications for conventional insulation resistance and photovoltaic (PV) insulation resistance measurement (PV:/>
see data sheet
) comparative insulation resistance measurement (COMP)
- timed insulation resistance measurement (TIME)
- external voltage detection function, which allows automatic monitoring of the voltage of the object under test
- designed with a timer to automatically record the test time
- automatic discharge and high-voltage warning for analogue resistance warning
Results
- Manual/automatic shutdown
- Capable of storing 1,000 data sets
- data save/delete function
- Data logging function
- Bluetooth app
- manual / automatic backlight
- mute function
- high-resolution segmented LCD display
- battery: high-capacity
a6: 161 x 117.3 x 63 mm
- Weight: 0.5 kg
Accessories:
- test leads
- test probes with torch:
- alligator clips:
- MC4 connectors: 1 pair
- battery transport cable
-
Type C battery transport cable
AA: 6 pcs
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT502A Insulation Resistance Tester
This product comes with a 3-year warranty. UT502A Insulation Resistance Tester.
The UT500 series electrical insulation testers are used to measure the insulation resistance of electrical equipment and household appliances during routine inspections. This is achieved by measuring the insulation resistance between electrical circuits or between circuits and earth (the equipment’s earth). The UT500 series can measure insulation resistance, AC voltage, low resistance, PI (polarisation index) and DAR (dielectric absorption). The individual units in the UT500 series differ from one another in their test voltage ranges (UT501A 100V to 1000V, UT501B 250V to 1000V, UT502A 500V to 2500V), maximum measured insulation resistance (UT501A 5GΩ to 5GΩ, UT502A 0MΩ to 20GΩ) and other parameters.
These testing and inspection devices ensure the correct operation of transformers, generators, high-voltage motors, power capacitors, power cables, surge arresters, circuit breakers, and electrical machinery and equipment. They are ideal devices for carrying out electrical maintenance and are manufactured in accordance with IEC 61010 and IEC 61557 standards.
UT502A specifications:
- insulation resistance measurement from 0 MΩ to 5.5 GΩ
- DC voltage testing 500V /
- measurement of 500V / 12,000V /
dielectric loss tangent and dielectric absorption
- low resistance measurement from 0 to 200Ω
- AC voltage measurement in the range from 30 to 600V (50 / 60Hz)
- overload indication at > 22GΩ
- Backlit LCD display with automatic secondary display switching range
--999 voltage and start functions
- Red warning light
- Powered by 6 x 1.5V (AA) batteries
- low battery indicator
- CAT III 600 V overvoltage protection
UT502A technical specifications:
- insulation resistance measurement / internal voltage measurement / insulation voltage resistance
500V / 0.00MΩ to 5.5GΩ / 1.00 mA to 1.10mA / 500kΩ
1000V / 0.00MΩ to 5.5GΩ / 1.00 mA to 1.10mA / 1M200mA / 1MV / 200kΩ 1.00 mA to 1.10 mA / 1 MΩ
- open-circuit voltage tolerance: +10%
- short-circuit current of test voltage: less than 1.8 mA
- Accuracy range for insulation resistance measurement: 0.00 MΩ to 99.9 MΩ: ±3 Ω; 10 GΩ: ±(5% + 5) Ω; 10 GΩ to 20 GΩ: ±(10% + 5) Ω
- Polarisation index measurement for a measurement time of 10 minutes / 1 minute
- PI value / criterion: ≥ 4 / excellent, 4 to 2.0 / good, ≤ 1.0 / warning, 1.0 / poor
- Measurement of dielectric absorption for 60 sec / 30 sec
- DAR value / criterion: ≥ 1.4 / best, 1.25 to 1.0 / good, ≤ 1 / poor
- low resistance measurement (circuit: 000000000) 200Ω
- resolution: 0.01Ω
- Display reset for more accurate measurements: yes, ZERO button
- open-circuit voltage before measurement: approx. 5.0 V
- current during measurement: approx. 200mA
- Accuracy: ± (2% + 3)
- AC voltage measurement - range: 30 V to 600 V (50 / 60 Hz)
- resolution: 1 V
- Accuracy: ± (2% + 3)
- 60 mm multifunctional LCD display. 34 mm, range 1999
- Display backlight: option for white or red backlight during warning
- automatic range switching: yes
- buzzer: yes, high voltage indication
- Automatic discharge of internal capacitance after measurement: yes
- power supply: 6x alkaline battery (test mode) 1 voltage (test mode) 1 voltage
- low battery indicator: yes, when voltage drops below 7V
- Weight: 0.7kg (including battery)
- Product dimensions: 150 x 100 x 71mm
- Calibration conditions for product colour: red 2 and grey
- Calibration environmental conditions: ±5 °C, humidity 45% to 75%
- Recommended calibration: once a year; the calibration protocol must be ordered separately
- operating conditions: 0 °C to +40 °C / relative humidity 85% or less
- Storage conditions: -20 °C to +60 °C / relative humidity <90% – max. 2000 m
Contents of individual package:
- UT502A unit: 1 pc
- test leads: 1 pair
- alligator clips: 1 pair
- 1.5V AA battery (LR6): 6 pcs
- instructions: English, Czech, Slovak: 1 copy
Wholesale packaging:
- standard quantity per box: 20 pcs
- standard box dimensions: 500 x 380 x 330 mm
- total weight of the box: approx. 18.9 kg
Manufacturer:
https://www.uni-trend.com/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. UT501B insulation resistance tester.
The UT500 series electrical insulation testers are used to measure the insulation resistance of electrical equipment and household appliances during routine inspections. This is achieved by measuring the insulation resistance between electrical circuits or between circuits and earth (the equipment’s earth). The UT500 series can measure insulation resistance, AC voltage, low resistance, PI (polarisation index) and DAR (dielectric absorption). The individual units in the UT500 series differ from one another in their test voltage ranges (UT501A 100V to 1000V, UT501B 250V to 1000V, UT502A 500V to 2500V), maximum measured insulation resistance (UT501A 5GΩ to 5GΩ, UT502A 0MΩ to 20GΩ) and other parameters.
These testing and inspection devices ensure the correct operation of transformers, generators, high-voltage motors, power capacitors, power cables, surge arresters, circuit breakers, and electrical machinery and equipment. They are ideal devices for carrying out electrical maintenance and are manufactured in accordance with IEC 61010 and IEC 61557 standards.
UT501B product specifications:
- insulation resistance measurement from 0 MΩ to 5.5 GΩ
- DC test voltage measurement 250V /
- Low resistance measurement from 0 to 200Ω
- AC voltage measurement in the range from 30 to 600V (50 / 60Hz)
- Overload indication at >5.5GΩ
- Backlit LCD display with automatic secondary display switching
- 199> voltage and start-up functions
- Red warning light
- Powered by 6 x 1.5 V (AA) batteries
- Low battery indicator
- CAT III 600 V overvoltage protection
Technical specifications of the UT501B:
- internal voltage measurement / insulation resistance / insulation resistance
250V / 0.00MΩ - 5.5GΩ / 1.00mA - 1.10mA / 250kΩ
500V / 0.00MΩ - 5.5GΩ / 1.00mA - 1.10mA / 500kΩ - 500kΩ - 0V0Ω /M500. / 1.00mA - 1.10mA / 1MΩ
- open-circuit voltage tolerance: +10%
- short-circuit current of test voltage: approx. 2mA
- insulation resistance measurement accuracy range: 0.00MΩ to 99.9MΩ: ± (3% + 5) / 100MΩ to 5.5GΩ: ± (5% + 5)
- Polarisation index measurement for a criterion value measurement duration of 10 minutes /⥥: 10 minutes PI /⥥ 1 minute 4 / best, 4 to 2 / good, 2.0 to 1.0 / warning, ≤ 1.0 / poor
- Dielectric absorption measurement for 60 sec / 30 sec
- DAR value / criterion: ≥ 1.4 / best, 1.25 / 1, ≤ / 1 / 1. poor
- low resistance measurement (circuit continuity) - range: 0.00Ω to 200Ω
- resolution: 0.01Ω
- Display reset for more accurate measurements: yes, ZERO button
- open-circuit voltage before measurement: approx. 5.0 V
- current during measurement: approx. 200mA
- Accuracy: ± (2% + 3)
- AC voltage measurement - range: 30 V to 600 V (50 / 60 Hz)
- resolution: 1 V
- Accuracy: ± (2% + 3)
- 60 mm multifunctional LCD display. 34 mm, range 1999
- Display backlight: option for white or red backlight during warning
- automatic range switching: yes
- buzzer: yes, high voltage indication
- Automatic discharge of internal capacitance after measurement: yes
- power supply: 6x alkaline (5V battery, low battery indicator)
- Voltage drops below 7V
- weight: 0.7kg (including battery)
- product dimensions: 150 x 100 x 71mm
- product colour: red and grey
- factory calibration conditions: ambient temperature 23°C ± 5°C, humidity 45% to 75%/year; calibration protocol recommended once a year. Ordered separately
- operating conditions: 0 °C to +40 °C / relative humidity 85% or less
- Storage conditions: -20 °C to +60 °C / relative humidity 90% or less
- Altitude: max. 2000 m
Contents of individual package:
- UT501B unit: 1 pc
- test leads: 1 pair
- Alligator clips: 1 pair
- 1.5 V AA battery (LR6): 6 pcs
- instructions: English, Czech, Slovak: 1 copy
Wholesale packaging:
- standard quantity per box: 20 pcs
- standard box dimensions: 500 x 380 x 330 mm
- total weight of the box: approx. 20.9 kg
Manufacturer:
https://www.uni-trend.com/
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT501A Insulation Resistance Tester
This product comes with a 3-year warranty. UT501A Insulation Resistance Tester.
The UT500 series electrical insulation testers are used to measure the insulation resistance of electrical equipment and household appliances during routine inspections. This is achieved by measuring the insulation resistance between electrical circuits or between circuits and earth (the equipment’s earth). The UT500 series can measure insulation resistance, AC voltage, low resistance, PI (polarisation index) and DAR (dielectric absorption). The individual units in the UT500 series differ from one another in their test voltage ranges (UT501A 100V to 1000V, UT501B 250V to 1000V, UT502A 500V to 2500V), maximum measured insulation resistance (UT501A 5GΩ to 5GΩ, UT502A 0MΩ to 20GΩ) and other parameters.
These testing and inspection devices ensure the correct operation of transformers, generators, high-voltage motors, power capacitors, power cables, surge arresters, circuit breakers, and electrical machinery and equipment. They are ideal devices for carrying out electrical maintenance and are manufactured in accordance with IEC 61010 and IEC 61557 standards.
UT501A product specifications:
- Insulation resistance measurement from 0 MΩ to 5.5 GΩ
- DC test voltage 100 V / 520 V / 500 V / 1000 V
- AC voltage measurement in the range from 30 to 750 V (50 / 60 Hz)
- Overload indication at >5.5 GΩ
- Backlit LCD display with a range of 1999
- Automatic range switching
- Secondary display for red light warning function
Power supply: 6 x 1.5V (AA) batteries
- Low battery indicator
- CAT III 600 V overvoltage protection
Technical specifications of the UT501A:
- Rated test voltage / insulation resistance measurement range / rated measurement current / internal resistance 1000V //>000V //> 100MΩ / 1.00mA to 1.10mA / 100kΩ
250V / 0.00MΩ to 5.5GΩ / 1.00mA to 1.10mA / 250kΩ
500V / 0.00MΩ to 5.5GΩ / 5.1.0mA / 5.1.0mA 500kΩ
1000V / 0.00MΩ to 5.5GΩ / 1.00mA to 1.10mA / 1MΩ
- open-circuit voltage tolerance: +10%
- test voltage short-circuit current: less than 1.8mA to 0.00mA, resistance measurement range at 0000mA
00. 99.9MΩ: ± (3% + 5) / 100MΩ to 5.5GΩ: ± (5% + 5)
- AC voltage measurement - range: 30 V to 750 V (50 / 60 Hz)
- resolution: 1V
- (display accuracy: 1V
- ± 2%/-: 3) 70.6 mm x 34 mm multifunction LCD, 1999-digit range
- Display backlight: option of white backlight or red backlight during warning
- automatic range switching: yes
- buzzer: yes, high voltage indication
- Automatic discharge of internal battery after measurement: yes (AA)
- low battery indicator: yes, when voltage drops below 7V
- weight: 0.5kg (including battery)
- product dimensions: 150 x 100 x 71mm
- product colour: red and grey
- factory calibration conditions: ambient temperature 23 °C, humidity ± 23 °C, ± 75% humidity
- recommended calibration: once a year; the calibration protocol must be ordered separately
- operating conditions: 0°C to +35°C / relative humidity 75% or less
- storage conditions: -20°C to +60°C / relative humidity 80% or less
- Altitude: max. 2000 m
Contents of individual package:
- UT501A unit: 1 pc
- test leads: 1 pair
- Alligator clips: 1 pair
- 1.5V AA battery (LR6): 6 pcs
- instructions: English, Czech, Slovak: 1 copy
Wholesale packaging:
- standard quantity per box: 20 pcs
- standard box dimensions: 500 x 380 x 330 mm
- total weight of the box: approx. 17.7 kg
Manufacturer:
https://www.uni-trend.com/
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT 387S is a wall scanner capable of detecting ferrous and non-ferrous metals, electrical cables and wooden structures hidden within walls, ceilings, floors and behind plasterboard. Additional features include a laser for convenient distance measurement and a wood moisture detector. The device features a large 2.4” display, which shows icons for the objects found: wooden object, small metal object (nail), large metal object (steel structure), small non-magnetic metal (cable, wire), small quantity of metal objects (cables, nails) It indicates the depth of the objects and the presence of AC voltage (the best electromagnetic wiring when searching for wiring) when connected to the device and the device is switched on.
The laser distance meter allows you to measure distances of up to approx. 20 m and, with an additional reflective surface (reflector), up to 40 m, with automatic calculation of rectangular areas and rectangular volumes. The height of objects can also be calculated based on a perpendicular. Modes: single measurement, addition and subtraction of measured values, continuous measurement of distances, areas, volumes, height in a right-angled triangle, unit conversion, allows you to store 30 data sets and retrieve historical data from memory. Voice prompts, buzzer, silent mode. 8 mm and in the range from 6% to 40% when the probe is inserted into the material.
Power is supplied by a built-in lithium-ion battery with a capacity of 300mAh, which charges via USB-C. Automatic calibration.
Widely used in home renovations, flats and DIY projects.
>
>
>
. modes for detecting various objects within walls
- several ways to use a laser rangefinder
- measuring wood moisture
- 2.4" colour display
- built-in Li-ion battery
- CE/RoHS certification
- Technical specifications:
--wood homogeneity detection mode: 38 mm
- precision wood scanning depth: 20 mm
- Ferrous (ferromagnetic) metal scanning depth: 100 mm
- Non-ferrous metal scanning depth: 80 mm
- scanning depth for copper cables (≥4 mm²) for precision detection
under 4 mm². Voltage: 50 mm
- automatic calibration: yes
- Audible alarm: yes
- Operating temperature: 0 °C to 40 °C
- Operating humidity for metal detection: 0 to 85% RH
- Operating humidity for AC cable detection: 0 to 30% RH; for wood detection: 0 to 60% RH
Laser rangefinder
- Laser distance measurement range: 0.05 m to 40 m
- Laser measurement accuracy: ± 2 mm
- Units of measurement: metres, feet, inches
- Laser measurement modes: single measurement, cumulative and continuous, area and volume measurement, subtraction, height measurement
- measurement base: front / rear
- laser - class, wavelength and power: Class II, 630–670 nm, <1 mW
- Data storage: yes, for 30 data sets
- automatic laser shut-off: after 20 seconds
wood moisture range: 6% moisture
- 40%
- moisture measurement accuracy: ± 2%
- Maximum detection depth: 8 mm
- General parameters:
- Display type, diagonal: EBTN-LCD, bright display on a dark background, 2.4 inches
- Power supply: 30 V/30 mAh lithium battery. Auto-off: yes, after approx. 5 minutes
- Low battery warning: yes
- Operating time per battery charge: 3000 individual measurements
- storage temperature: -20 °C to 60 °C
- Net product weight: 161.2 g
- Product dimensions: 160 x 68 x 31 mm
-
Individual product colour:/>
-
packaging:
- UT 387S device: 1 pc
- USB-C interface cable: 1 pc
- Cloth bag: 1 pc
- User manual: 1 pc
Wholesale packaging:
Standard quantity per box: 200 pcs. 270 × 235 mm
MANUFACTURER: UNI-TREND
10 - 20 days
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UT 387LM is a wall scanner capable of detecting ferrous and non-ferrous metals, electrical cables and wooden structures hidden within walls, ceilings, floors and behind plasterboard. As an additional feature, it incorporates a laser for convenient distance measurement. The device features a large 2.4-inch display, which shows icons for the objects found: wooden object, small metal object (nail), large metal object (steel structure), small non-magnetic metal (cable, wire), small quantity of metal objects (cables, nails) It indicates the depth at which objects are buried and the presence of AC voltage (the best electromagnetic wiring when searching for wiring) when connected to the device and the device is switched on.
The laser distance meter allows you to measure distances of up to approx. 20 m and, with an additional reflective surface (reflector), up to 40 m, with automatic calculation of rectangular areas and rectangular volumes. The height of objects can also be calculated based on a perpendicular. Modes: single measurement, addition and subtraction of measured values, continuous measurement of distances, areas, volumes, height in a right-angled triangle, unit conversion, allows you to store 30 data sets and retrieve historical data from memory. Voice prompts, buzzer, silent mode. USB-C. Automatic calibration.
Widely used in home renovations, flats and DIY projects.
Product specifications:
- multiple modes for detecting various objects within walls
- multiple modes of use for a laser rangefinder
Technical specifications of the detector
- Wood detection depth: 38 mm
- precision wood scanning depth: 20 mm
- Ferrous (ferromagnetic) metal scanning depth: 100 mm
- Non-ferrous metal scanning depth: 80 mm
- Copper cable scanning depth (⥥4 mm²): 40 mm
- accuracy of live AC wire detection: 50 mm
- automatic calibration: yes
- Audible alarm: yes
- Operating temperature: 0 °C to 40 °C
- Operating humidity for metal detection: 0 to 85% RH; for cable detection: 30% RH
- Operating humidity: 30% RH
- Operating humidity for wooden beam detection: 0 to 60% RH
Laser rangefinder
- Laser distance measurement range: 0.05 m to 40 m
- Laser measurement accuracy: ± 2 mm
- Measurement units: measurements, single measurements, laser mode, fee/set, continuous measurement, addition and subtraction of measured values, areas, volumes, heights
- measurement modes: front/rear
- laser - class, wavelength and power: II, 630–670 nm, <1 mW
- data storage: yes, for 30 data sets
- after automatic laser switch-off 2--/>- General parameters:
- display type, diagonal: EBTN-LCD, bright display on a dark background, 2.4 inches
- power supply: 3.7V / 300mAh lithium battery
- Automatic device shutdown: yes, after approx. 5 minutes
- low battery warning: yes
- Charging time: 3000 mAh. Measurements
- Storage temperature: -20 °C to 60 °C
- net product weight: 158 g
- Product dimensions: 153 x 68 x 31 mm
- Product colour: red and grey
Contents of individual package:
- USB interface cable:
- LM UT:-1p8
1 pc
- cloth bag: 1 pc
- user manual: 1 pc
Wholesale packaging:
Standard quantity per box: 20 pcs
Standard box dimensions: 360 × 270 × 235 mm