In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty.
The UT196 True RMS solar multimeter from UNI-T is a professional-grade product designed for professionals who install or maintain photovoltaic or wind power plants. The device’s design allows it to operate in harsh outdoor environments – it has IP65 protection and can withstand a drop from a height of 2 m. This multimeter measures DC voltage up to 1700 V and AC voltage (true RMS) up to 1500 V at a frequency range of 45 to 1000 Hz. With the optional UT-CS09D Flex current loop, it allows non-contact measurement of AC currents from 1.5 to 3000 A, even in confined spaces. In addition, the UT196 measures frequency, resistance, capacitance, semiconductor transitions and electrical circuit continuity.
The low-pass function allows you to filter out RF interference generated by the inverter. The low-impedance mode can help with troubleshooting sensitive circuits, as well as circuits that may contain stray voltages. A built-in torch, a bright backlight, and audible and visual alarms allow users to complete their work safely and efficiently, even in dark and noisy environments.
The UT196 solar digital multimeter is designed with overload protection of 1700V DC, 1500Vrms AC and tested for safe use in a CAT III 1000V, CAT IV, UK and CA600V, UK and CA 600Vrms certified environment. cETLus.
Product specifications:
- Multifunctional multimeter designed for use in both outdoor and indoor photovoltaic and wind power installations
- measurement of AC/DC voltage, resistance, capacitance, frequency, diodes, circuit continuity, with external current loop and AC current
- LCD display
-, backlit maximum value
-- display: ± 6000, values are updated 2 to 3 times per second
- analogue bar graph: yes, 31 segments, measurement rate of 30 times per second
- range switching: automatic / manual
- automatic AC/DC voltage detection: yes
- non-contact electromagnetic field measurement (NCV): yes
- diode testing (semiconductor junctions): yes, open-circuit voltage approx. 3V
- electrical circuit continuity test: yes, the circuit is considered closed when R ≤ 10Ω, then the buzzer emits a beep
- built-in low-pass filter (LPF): yes, when the LPF is activated, interfering voltages above 1.2 kHz are attenuated by ≥ -3 dB/0>Hz relative to the measured attenuationHz. yes
- Peak Hold: yes
- Data Hold: yes
- Max/Min mode: yes
- Power supply: 9V battery / 6F22,
- Low battery indication: yes, when voltage drops below <7.5V, - automatic switch-off during inactivity
-1
- minutes
- Built-in torch: yes
- audible and visual indicator: yes
Technical parameters:
DC voltage measurement (V): Range / Resolution / Accuracy
600.0 mV / 0.1 mV / ±(0.5%/1 V/5.0)
±(0.2%+5)
60.00 V / 0.01 V / ±(0.2% + 5)
600.0 V / 0.1 V / ±(0.2% + 5)
1700V / 1V / ±(0.2%+5)
The input range is approximately mV/DC. 1GΩ.
AC voltage measurement (V): Range / Resolution / Accuracy
600.0 mV / 0.1 mV / 45 Hz to 500 Hz: ± (0.8%+3); 500 Hz to 1 kHz: ± (1.8%+3)
6.000V / 0.001V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)
60.00 V / 0.01 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
600.0V / 0.1V / 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)
1500 V / 1 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
Input impedance in the mV/AC range is approx. 10MΩ.
Automatic AC/DC voltage measurement: automatic range / Resolution / Accuracy
0V to 600.0V / 0.1V / DC to 500Hz: ± (2.0%+3); 500 Hz to 1 kHz: ± (4.0%+3)
With automatic range selection, LPF, Peak Hold selection is not possible; the input impedance is 2 MΩ
Resistance measurement: range / resolution / accuracy
600.0Ω / 0.10Ω / ±20.10Ω / ±20.10Ω 1Ω / ± (0.8%+2)
60.00 kΩ / 10 Ω / ± (0.8% + 2)
600.0 kΩ / 100 Ω / ± (0.8% + 2)
6,000 MΩ / 1 kΩ / ± (1.2%/+6 Ω)<0br/>+3 Ω. (2.5%+5)
Capacitance measurement: Range / Resolution / Accuracy
60.00 nF / 0.01 nF / in REL mode: ± (3%+10)
600.0 nF / 0.1 nF / ± (1.9% > +5.00 μF / 0.00 μF / 0.00 μF / 5.00 μF) ± (1.9% + 5)
60.00 μF / 0.01 μF / ± (1.9% + 5)
600.0μF / 0.1μF / ± (1.9%+5)
6,000 mF / 0.001 mF / ± (5% > +5)
0.001 mF / 0.001 mF / ± (5% >+5) ± (5%+5)
Measurement of AC currents with a UT-CS09D Flex current loop: Range / Resolution / Accuracy
30.00A / 0.01A / ± (0.8%+8)
300.0A / 0.1A /+300.0A / 0.1A /+0. ± (0.8%+8)
Frequency measurement: Range / Resolution / Accuracy
60.00 Hz to 1,000 MHz / 0.1 Hz to 0.001 MHz / ± (0.08% +4)
Other operating parameters: -0.001 MHz 40°C (32°F – 104°F)
- Storage temperature: -10°C to 50°C (14°F to 122°F)
- relative humidity: ≤75% RH (0°C - 30°C), ≤50% RH (30°C) operating altitude -
≤2000m
- EMC immunity: in accordance with EN61326-1: 2013, EN61326-2-2: 2013
- Power supply: 9V battery / 6F22
- External dimensions: 195 x 95 x 58 mm
- Weight: 4–85 g
- Drop test: 2m
- Certification: CE, UKCA, cETLus (CAT III 1000V, CAT IV 600V)
- Complies with standards: EN61010-1, EN61010-2-033, EN/IEC 61010-031 :-Contents of individual packaging :-/>
UT196 Solar PRO multimeter: 1 pc
- test leads: 1 pair
- 9V/6F22 battery: 1 pc
- user manual: 1 pc
Manufacturer:
UNI-TREND
-
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty.
UT219PV Professional AC/DC clamp meter specially designed for high-voltage photovoltaic environments. It offers exceptional accuracy and performance with a wide range of features. With automatic range selection and a clear display capable of showing up to 9999 digits, this clamp multimeter enables precise measurements of AC/DC voltage, current, low-frequency filtered voltage/current, inrush current, peak current, DC power, resistance, circuit continuity, diodes, capacitance and temperature. Its versatility extends beyond photovoltaic applications, as it can also be used in other high-voltage devices, such as energy storage systems, uninterruptible power supplies (UPS) and large motors. DC
- Current measurement: AC / DC 1000A
- DC power supply: 2500 kVA
- External clamp sensor: UT-CS09D (AC 3000 A)
- Solar panel polarity indication: when <-10 DCV, audible and visual alarm
- AC/LP pass filter
- Bluetooth-F pass filter
voltage/current.
- Measurement of alternating start-up current and peak value
- Automatic backlight and auto-off
- Certificates: CE (EMC, LVD), cETLus, RoHS
- Safety category: CAT III 1500V / CAT IV 600V
- Protection rating: IP6/Technical
Parameters:
- AC current (A): 999.9 A 40Hz–100Hz ±(2.0%+5), 100Hz–1000Hz ±(2.5%+5)
- DC current (A): 999.9 A ±(2.0%+5):/AC voltage (2.0%>-5)
- DC voltage (V): 999.9 V / 2500 V ±(1.0%+5)
- DC voltage (mV): 999.9 mV ±(1.0%+5)
V (with L.0%+5)
- AC voltage ±(2.0%+9)
- AC current (with LPF): 999.9 A ±(2.5%+9)
- Flexible clamp AC current sensor (with LPF): 30.00 A / 300.0 A / 3000 A ±(4.0%+9)
- 0.00 A / 300.0 A / 3000 A ±(4.0%+9)
-3p. 300.0 A / 3000 A ±(3.0%+5)
- DC power: 999.9 kVA / 2500 kVA ±(1.0%+5)
- Frequency: 50 Hz – 999.9 kHz ±(0.5%+5)
- Resistance (0.5%+5)
-999 Ω. 99.99 kΩ ±(1.0%+3)
- Capacitance: 100.0 μF / 1000 μF ±(1.0%+5)
- temperature: -40°C – 4000°C ±(1.0%+30)
- True RMS
- max. display: 9999
- LCD display: dual display (V+A)
- Jaws (max. conductor diameter) 35 mm
- Diode test
- Solar panel polarity indication: at <-10 V DC, audible and visual alarm
- high voltage alarm
- HOLD range exceeded indicator
-/AUTO
- current
- PEAK
- Bluetooth BT 5.0 app
- automatic backlight
- low battery indicator √
- flexible clamp compatible with UT-CS09D (optional)
- protection rating: IP65
- Power supply: 1.5V AA battery × 5 mm × 5 mm × 2 mm
Accessories:
- test probe
- temperature probe
- battery
manufactured by UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT204R Clamp Multimeter
This product comes with a 3-year warranty. The UT204R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on low-voltage distribution lines in CAT II. With the included Type K thermocouple (nickel-chromium-nickel-silicon temperature sensor), it allows temperature measurement from -40°C to 1000°C. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is <11μA, which effectively extends the battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and high-voltage frequency up to 600 V
- frequency measurement from 10 Hz to 10 MHz
- Measurement capabilities
- 60 mF
- Temperature measurement from -40 to +1000 °C
- Measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600 V in intervals
- Non-contact detection of live voltages and switching accuracy of live conductors
-
guaranteed within the range of 1% to 100% of the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +5)
600.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% + 5) The accuracy of AC frequency monitoring in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620 A
2. DC current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / ± (2.0% + 5)
600.0 A / 0.100 A / ± (2.0% + 5)
- overload protection at 620 A
>
>
6,000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
60.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.0% +5) / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to 60 kHz ± (0.5% + 2) at a resolution of 0.01 Hz to 0.01 kHz
- input overload protection
- 0.01 kHz
- overload protection
- 60/0 V rm. 10 MΩ
4. DC voltage measurement (range / resolution / accuracy):
600.0 mV / 0.100 mV / ± (0.7% +3)
6,000 V / 0.001 V / ± (0.5% +2)
60.00 V / 0.010 V / 0.010 V / 0.010 V / 0.010 V / ±0.001 V / ± (0.5% +2) / 0.100 V / ± (0.5% +2)
- input impedance approx. 10MΩ
- overload protection at 600 Vrms
5. Resistance measurement (ranges / resolution / accuracy):
600.0Ω / 0.1Ω / ± (1.0% +2)
6,000 kΩ / 0.001 kΩ / ± (0.8% +2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / 60.8 kΩ ±2.0 kΩ 0.1 kΩ / ± (0.8% +2)
6,000 MΩ / 0.001 MΩ / ± (2.5% +5)
60.00 MΩ / 0.01 MΩ / ± (2.5% +5)
- overload protection at 600 Vrms open circuit
- approx. 1V
6. Capacitance measurement (ranges / resolution / accuracy):
60.00 nF / 0.01 nF / ± (4.0% +5)
600.0 nF / 0.1 nF / ± (4.0% +5)
6000 μF / 0.001 μF / ±4.0% +5)
60.00 μF / 0.01 μF / ± (4.0% +5)
600.0 μF / 0.1 μF / ± (4.0% +5)
6,000 mF / 0.001 mF / ± 10.0%
- overload protection at 600 Vrms
7. Temperature measurement (ranges / resolution / accuracy):
-40°C to +40°C / 1°C / ± 4°C
+40°C to +500°C/1°C / ± (1.5% +5)
+500°C to +1000°C/±2°C/1.5°C
-40°F to +104°F / 1°F / ± 6°F
+104°F to +932°F / 1°F / ± (2.0 +6)
+932°F to +1832°F / 1°F / ± 4
%
Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% +4)
load: 0.1 to 99.9% / 0.1% / ±5)
Note/+5. Sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
> 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS
- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency
Operating frequency
1 kHz 30.0% ~ 70.0%
- Overload protection at 600 Vrms
9. Checking circuit continuity:
- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 31Ω, the open-circuit signal does not emit a buzzer
- uncertainty in the range from 10Ω to 31Ω. 600Ω range
- Overload protection at 600 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 4.0V
- measurement in the range of 6.000V
Non-contact electric field sensing (NCV):
- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz
Other parameters:
- measurement of maximum and minimum values
- relative measurement of maximum and minimum. Mode (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 37 mm x 25 mm
- Product dimensions: 631.5 mm x 631 mm
- net product weight: 235 g
- Product colour: red and grey
Package contents:
- UT204R clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 101 V: 0 pcs
(R03): 2 pcs
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight per box: 16/F: 7 kg
https://www.uni-trend.com/
UNI-T UT208B Clamp Multimeter
This product comes with a 3-year warranty. The UT208B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 100000000000V at 400Hz and low voltage (mn) 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows LV distribution measurements in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled.
Product specifications:
- measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance
- automatic polarity display
- Measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range 10 Hz to 1 MHz
- capacitance measurement from 60 nF to 60 mF
- Temperature measurement from -40 to +1000 °C with a closed K-type thermocouple
- measurement of the (relative) ratio of voltages and voltages and capacitances
multiple visual protection voltages greater than 1000 V in ranges
- NCV function – non-contact detection of live conductors
- LoZ V function ~ measurement with low input impedance (approx. 2 kΩ) of the device
- INRUSH function – measurement of transients up to 100 ms – inrush current on device start-up with an additional 3,000,000 loop at the LPF ACV function – AC voltage measurement with an NF filter (approx. 2.5 kHz) on inverters and variable-frequency drives
- Frequency/duty cycle measurement function
- Choice between automatic or manual switching
- Built-in lamp
- Accuracy of current and voltage measurement is guaranteed when using the range from 10% to 10%; within 5% of this range, it is necessary to change the range
Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9)
600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5)
- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz
- Overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.000Hz / 40.010Hz ±(10.0%+10)
300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10)
3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection
-10 3000A
3. DC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / ±(2.0%+5)
600.0A / 0.100A / ±(2.0%+5)
1000.0A / 1A / ±(2.0%+5) overload protection
2.0%/>-5 1000A
4. AC voltage measurement (range / resolution / accuracy):
6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3)
60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)
60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8)
- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz
- Overload protection at 1000 Vrms
- Input impedance approx. 10 MΩ
5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ
6. AC LPF V (measurement with low input impedance approx. 2 kΩ)
(range / resolution / accuracy):
600.0 V / 0.1 V / ±(2.0%+5)
1000.0 V / 1 V / ±(2.0% + 5)
- Input overload protection rm approx. 2kΩ
7. DC voltage measurement
(range / resolution / accuracy):
600.0 mV / 0.100 mV / ±(0.8%+3)
6,000 V / 0.001 V / ±(0.5%+3)
60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3)
1000.0 V / 1 V / ±(0.5%+3)
- overload protection at 1000Vrms
- input impedance approx. 10 MΩ
8. Resistance measurement
(range / resolution / accuracy):
600.0Ω / 0.1Ω / ±(1.0%+3)
6,000 kΩ / 0.001 kΩ / ±(1.0% + 2)
60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2)
6,000 MΩ / 0.001 MΩ / ±(2.0%+8)
60.00 MΩ / 0.01 MΩ / ±(2.0%+8)
- overload protection at 1000 Vrms open-circuit voltage approx.
- 1 V
9. Checking circuit continuity:
- if the measured resistance is less than 30Ω, the continuity signal emits a beep
- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep
- uncertainty between 31Ω and 69Ω
- 600Ω, with a resolution of 0.1Ω
- overload protection at 1000 Vrms
10. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.0V
- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V
11. Capacitance measurement
(range / resolution / accuracy):
60.00 nF / 0.01 nF / ±(4.0%+25)
600.0 nF / 0.1 nF / ±(4.0%+5)
6,000 μF / 0.001 μF ±(4.0%+5)
60.00 μF / 0.01 μF / ±(4.0% + 5)
600.0 μF / 0.1 μF / ±(4.0%+5)
6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9
- overload protection at 1000 Vrms
12. Temperature measurement
(ranges / resolution / accuracy):
-40°C to +300°C / 0.1°C / ± 1.0°C+20
+300°C to +1000°C / 1°C / ±(1.0%+2)
+573°F to +1832°F / 1°F / ±(1.0%+4)
13. Frequency measurement and operating cycle (filling)
(ranges / resolution / accuracy):
frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
Fill: 10% to 99.1% / ±99.0% / ±7)
- Note 1) Measurement sensitivity:
10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS
100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS
Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:
2Vpp ≤ input amplitude ≤ 20V p-p
- overload protection at 1000 Vrms
14. Non-contact electric field sensing (NCV):
- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will start flashing. (ratio) for voltage and capacitance measurement: yes
- HOLD: yes
- low battery indicator: yes
- Auto power off: yes
- Power supply: 1.5 V batteries (R03): 2 pcs
- Backlit display size: 43 x 45 mm
- Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g
- Product colour: red and grey
Package contents:
- UT208B clamp multimeter: 1 pc
- Test leads: 1 pair
- K-type thermocouple up to 1000°C: 1 pc
3:
>- (battery
3): user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 5 pcs
- standard box dimensions: 355 mm x 330 mm x 165 mm
- standard gross weight per box: 4.5 kg
UNI-TREND MANUFACTURE
https://www.uni-trend.com/
UNI-T UT362 USB Anemometer
This product comes with a 3-year warranty. The UNI-T UT362 USB anemometer is a small, stable and reliable handheld instrument for measuring wind speed and temperature, featuring a separate speed sensor that ensures rapid detection, low power consumption and high accuracy. The anemometer allows automatic measurement at predetermined intervals of 0.5 to 255 seconds and the storage of values in the internal memory for up to 2044 records, with subsequent transfer to a computer via the USB interface. Large backlit display (57 mm x 37 mm), showing wind speed and temperature simultaneously.
The device can be used in many fields – such as mining, petrochemicals, energy, navigation – in aviation and maritime transport, in the manufacture of fans or the installation of exhaust and air recovery ventilation systems, as well as in sport. Powered by a 9V alkaline battery, with automatic switch-off after approximately 10 minutes of inactivity, which can be deactivated.
Product specifications:
- wind speed measurement range: 0 ~ 30 m/s
- the instrument and the measuring handle are connected by a cable
- with high-precision anemometer tip
- reliability
- wide selection of wind speed units (VEL): (m/s, km/h, ft/min, MPH, KNOTS)
- Selection of wind flow units (FLOW): CMM (cubic metres per second), CFM (cubic feet per minute)
- wind speed measurement modes: MAX, MIN, real-time
, MAX, wind flow mode
, MAX, MAX, MAX2, MAX, MAX in real time
- temperature measurement range: 10°C ~ 40°C
- unit selection: °C or °F
- Display backlight: yes
- Data Hold: yes
- automatic interval recording function: 0.5 to 255 s
- Data storage: up to 204/4 records per PC storage yes
Technical parameters:
- Wind speed measurement range: 2 m/s to 10 m/s, resolution 0.1 m/s, accuracy ± (3% of reading + 0.5)
- wind speed measurement range: 10 m/s to 30 m/s, resolution 3%, measurement accuracy ± (3% of reading +0.8)
- wind flow measurement (CMM): 0.001 to 9999 x 100
- wind flow measurement (CFM): 0.001 to 9999 x 100
- Sampling rate: approx. 2 measurements per second
- Temperature measurement range: 10°C ~ 40°C, resolution 0.1°C, accuracy ± 3°C (32°F ~ 104°F, resolution 0.2°F, accuracy ± 4°F
- measurement of maximum, minimum or average values: MAX / MIN of the wind sensor type based on the wind sensor display principle: MAX / MIN. magnetic induction
- temperature sensor type: negative temperature coefficient, NTC
- measurement pause: HOLD is displayed
- data storage: 2044 records
- USB interface: yes
- display backlight: yes, can be switched on/off
- Auto-off: yes, after 10 minutes of continuous operation / disabled - Battery indicator: when voltage drops to ≤ 7.2V
- battery powered: 1 x 9V (6F22)
- device dimensions: 162 mm x 78 mm x 30 mm
- device weight: 375g
- product colour: red and grey
- operating temperature and humidity: 0°C to 35°C (32°F to 122°F), (relative humidity less than 75%)
- Storage temperature and humidity: -20°C to 65°C (-4°F to 149°F) (relative humidity less than 75%)
- pressure: 500 mbar to 2 bar
Contents:
UNI 2T USB pack
- 9V battery (6F22): 1 pc
- USB interface cable: 1 pc
- CD with PC software
- User manual
Wholesale packaging:
- Standard quantity per box: 10 pcs
- Standard box dimensions: 460 mm x 2135 mm, gross weight: 6.8 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
This product comes with a 3-year warranty.
The UT362H is a hot-wire anemometer, ideal for measuring air velocity and air temperature, thanks to its high stability, safety and excellent reliability. The device features automatic air flow calculation, allowing users to measure and record data in both indoor and outdoor applications.
Measuring indoor air velocity and airflow is an important indicator for assessing air quality. Thanks to its slim, extendable probe, the UT362H is extremely useful for HVAC/R professionals, facilitating air measurement inside ventilation ducts.
The device can be used in a wide range of sectors, such as:
mining
petrochemicals
the energy sector
maritime
aviation and shipping
fan manufacturing
air conditioning systems
ventilation systems
Key features
Extendable aluminium alloy rod, lightweight and durable
Separate design with retractable probe for easy measurements
Platinum resistance sensor
Storage of up to 99 data sets
Precise measurement of low air flows
Mode for measuring volumetric flow in ducts
Lightweight, ideal for professional use
Technical specifications
Air velocity measurement
0 ~ 30 m/s, accuracy ±(4% + 0.1 m/s)
0 ~ 108 km/h, accuracy ±(4% + 0.4 km/h)
0 ~ 5906 ft/min, accuracy ±(4% + 20 ft/min)
0 ~ 11 Bft, accuracy ±(1 Bft)
Air flow measurement
0 ~ 999,900 m³/min (resolution 0.001 ~ 100)
0 ~ 999,900 CFM (resolution 0.001 ~ 100)
0 ~ 999,900 L/s (resolution 0.001 ~ 100)
Temperature measurement
Range: -20 ~ 70 °C
Resolution: 0.1 °C
Accuracy: ±0.5 °C
Range in °F: 32 ~ 158 °F
Resolution: 0.1 °F
Accuracy: ±1.5 °F
Additional functions
Supported pipe shapes: circular, rectangular, flat
Dimension settings for rectangular sections (width & height)
Units of measurement:
Area: m², ft²
Air flow rate: m³/min, CFM, L/s
Air velocity: m/s, ft/min, km/h
Temperature: °C / °F
Start-up warm-up time: 5 seconds
Measurement mode: fast / slow
Sampling time: 0.5 s
Data Hold function
Display of MAX / MIN / average / multi-point average values
Internal memory: 99 data sets
Backlit LCD screen
Automatic switch-off after 5 minutes of inactivity (can be disabled)
Flexible probe length: 120 cm
Low battery indicator
Operating conditions
Operating temperature: 0 ~ 40 °C
Operating humidity: ≤80% RH
Storage temperature: 0 ~ 40 °C
Storage humidity: ≤80% RH
Power supply and dimensions
Power supply: 3 × 1.5V AAA batteries (included)
Dimensions: 180.3 × 63.0 × 40.1 mm (main unit)
Weight: approx. 312 g (excluding batteries)
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
This product comes with a 3-year warranty. The UNI-T UT25CL cable locator is a powerful device comprising a transmitter and a receiver. Featuring state-of-the-art sensors, it effortlessly tracks cables and wires, saving time and preventing accidental damage during installations or repairs. This tool detects wires, identifies breaks or short circuits, traces underground cables and locates fuses and related equipment. It also detects short circuits and open circuits in underfloor heating, monitors metal water and heating pipes, and supports up to 8 transmitters.
It is ideal for residential or commercial projects.
The UT25CL handheld detector can be used to trace the route of low-voltage cables buried in the ground (e.g. cables in walls); to test and diagnose disconnections, short circuits and other problems occurring on cables; and to determine whether the cable being tested is live. The transmitter can display the corresponding voltage (power cable voltage: ≥8V), whilst the receiver can simultaneously display signal strength, transmitter code, transmitter power level, low battery, etc. The UT25CL has many advantages, including accurate measurement, easy operation, a clear display and much more.
Wires, etc. – wire breaks, short circuits
- tracing of underground cables
- detection of fuses and circuit assignment
- detection of broken and short-circuited wires in metal underfloor heating systems
- tracing metal pipes for water distribution and heating
- accidental tracing of distribution sockets beneath sockets concealed beneath plasterboard distribution sockets
- automatic or manual adjustment of receiver sensitivity (3 adjustable levels, transmitter: 9 levels)
- torch and backlight functions
- automatic switch-off function
- one receiver can support up to 8 transmitters
- Live wire detection: up to 480 V (AC/DC)
Technical specifications:
Transmitter:
- output signal: 33 kHz
- Voltage range: 8 V – 480 V AC/DC, 50/60 Hz (2.5%)
- LCD display
- Display code value
- 0, 1, 2, 3, 4, 5, 6, 7
- three signal strength levels: 1, 2, 3
- Unipolar test: yes (live conductor test, max. voltage 480 V)
- Bipolar test: yes (live conductor test, max. voltage 480 V) Input LED
-/> 480 V input voltage indicator
-/> If V exceeds 25 V, the ELV LED will light up
2. as the voltage increases, the brightness of the ELV LED increases
3. in all other cases, the ELV LED will be dimmed or will not light up
- Power supply: 6 x 1.5V AA (LR06)
- Dimensions: 96 x 1894 x approx. 528 g
Receiver:
- Receiving signal: 33 kHz
- Cable detection range: approx. 0–2.5 m (single-phase application), approx. 0–0.5 m (two-pole application)
- Voltage range NCV 80V ~ 1000 V, 50Hz/60Hz
- Voltage detection: approx. 0–0.4 m
- Code value: 0, 1, 2, 3, 4, 5, 6, 7
- Three signal strength levels: 1, 2, 3
- LCD display
- Power supply: 6 x 1.5 V AAA (LR03)
- dimensions: 226 x 68 x 38 mm
- weight: approx. 354g
Other:
- backlight
- manual sensitivity adjustment
- Overvoltage category CAT III 480V
- IP54 protection
- certifications: CE, RoHS
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT195E PRO Line Multimeter
This product comes with a 3-year warranty. UNI-T UT195E PRO Line Multimeter
Product specifications and features:
- maximum display range: 6000
- Display interface (HTN): single display
- Measurement digit conversion rate: 3 times per second
- Analogue bar conversion rate: 10 times/s
- analogue bar: 31 sections
- True RMS
- low-pass filter test: 3 H/H attenuation) diode/continuity test: 3.5 V
- Auto/manual range
- Auto power off
- continuity buzzer
- low battery indicator
- data hold
- MAX/MIN
- function selection
- torch
- automatic operating temperature
- °C - automatic operating temperature
-°C 2m drop resistance
- protection rating: IP65
Technical parameters:
- DC voltage: 600mV - 1000V ±(0.5%+3)
- AC voltage: 600 mV – 750 V ±(0.7%:>+3 V AC
+3) ±(2.0%+3)
- DC current (A): 600.0 μA – 20 A ±(0.8% + 3)
- AC current (A): 600.0 μA – 20 A ±(1.0% + 3)
- Resistance (0.8%+3)
- Capacitance (0.0%+3)
- 600.0% ±0.0. Capacitance: 6.000 nF – 60.00 mF ±(3% + 5)
- Frequency: 60.00 Hz – 10.00 MHz ±(0.1%+4)
- duty cycle: 0.1% - 99.9% ±(2.0%+5)
- Frequency response: -4 AC
400 Hz
- AC current frequency response: 45 - 400 Hz
- Power supply: 9V 6F22 carbon-zinc or 6LR61 alkaline battery
- LCD size: 66mm × 51mm
- Device weight: 473g
- Device dimensions: 195 mm × 1995 mm × 58 mm
Accessories:
- Test probes
- Battery
- carrying case
- manual
Manufacturer:
UNI-TREND
UNI-T UT191T PRO Line Multimeter
This product comes with a 3-year warranty. UT191T Professional Multimeter
UT191 series professional multimeters designed for industrial users. The UT191’s new function memory retains the most recent mode setting at the next power-up, improving user efficiency. The UT191T supports accurate and precise temperature measurement.
Applications:
This series of CE/GS/cTUVus-certified multimeters complies with CAT III 600V and has an IP65 rating, making it suitable for use in damp and dusty environments.
1. Measurement settings are saved after a power reset
2. IP65, 2 m drop resistance
3. True RMS/peak value measurement
4. Automatic backlight
5. 20A current measurement
6. AC LoZ measurement
7. Precise temperature measurement with 0.1 ℃ resolution
Specifications: Range
DC voltage (V): 600V ±(0.5%+3)
AC voltage (V): 600V ±(0.7%+3)
Local.
ACV LPF: 600V ±(2%+5)
DC current (A): 20A ±(0.8%+3)
AC current (A): 20A ±(1%+3)
Resistance (Ω): 60MΩ ±(0.8%+2)
Frequency (Hz): 10Hz~1MHz ±(0.1%+4)
Frequency (Hz): 10Hz~1MHz ±(0.1%+4)
Duty cycle: 0.1%~99.9% ±(2%+5)
Temperature (℃): -40℃~400℃ (0.1°C resolution) ± 0.1°C: +20)(temperature
ACV peak hold ±(2%+100)
Peak current detection ±(3%+100)
Features:
Display rate: 600 times/sec. Bar graph: 31 sections
True RMS: √
Frequency response for AC voltage 45Hz~400Hz
Frequency response for AC current 45Hz~400Hz
Diode/continuity test: √
Auto/manual range: √ Auto power-off
/>Battery auto-shutdown indicator: √ √
Data hold/MAX/MIN: √
Function selection (SELECT): √
Flashlight/Auto backlight: √
2 m drop test/IP65: √
General features:
Power: 9V battery size:
8mm x 4mm
Net product weight: 428g
Product colour: red and grey
Product dimensions: 180mm x 87mm x 59mm
Standard accessories: test lead, battery, carrying case, contact-type temperature probe
Standard individual packaging: Gift box, English manual
Standard quantity per box: 10 pcs. 545 mm x 315 mm x 335 mm
Standard gross weight per box: 8.8 kg
Manufacturer: UNI-TREND
In stock
Contact us at contact@solartech.eu for more info regarding the inventory of this product.
UNI-T UT363 Anemometer
This product comes with a 3-year warranty. The UNI-T UT363 anemometer is a small, portable instrument for measuring wind speed and temperature. The device can be used in many fields – such as industry, mining, petrochemicals, energy, navigation, fan manufacturing, or the installation of exhaust and air recovery ventilation systems, as well as in sport. Drop-resistant from a height of 1 m. Backlit four-digit LCD display, measuring 32x26mm. Powered by 3x 1.5 V (AAA) batteries, with automatic shut-off after 5 minutes of inactivity.
Product parameters:
- wind speed measurement range: 0 ~ 30 m/s
- wide selection of speed units
- measurement of maximum, minimum or average values
- Temperature measurement range: -10°C to 50°C
- unit selection: °C or °F
- display backlight
Technical specifications:
- wind speed measurement range: 0 ~ 30 m/s, resolution 0.1 m/s, accuracy ±(5% of reading +0.5)
- 1. 108 km/h (for guidance only), accuracy ±(5% of reading +15 digits)
- Wind speed measurement range: 0.7 ~ 58 knots, (for guidance only), accuracy ±(5% of reading +10 digits)
- wind speed measurement range: 0.8 ~ ± 5%, accuracy (for guidance only 0.8%, ± 5%, measurement accuracy +10 digits)
- Wind speed measurement range: 78 ~ 5905 ft/min, (for guidance only), accuracy ±(5% of reading + 180 digits)
- Wind speed measurement range according to the Beaufort scale: 0 ~ 12 degrees, (for guidance only), measurement frequency accuracy: >- 1 degree
- 1 sample per second
- Temperature measurement range: -10°C ~ 50°C, resolution 0.1°C, accuracy ± 2°C (14°F ~ 122°F, resolution 0.2°F, accuracy ± 4°F
- measurement of maximum, minimum or average values: MAX / MIN / MIN / AVG: the wind speed display is higher than the overload speed
OLG 45 m/s or the temperature is below -10°C or above 50°C, ‘OL’ is displayed.
- “WIND CHILL” warning: if the temperature is below 0°C and the wind speed is greater than 5m/s, the “WIND CHILL” warning is displayed. NTC
- Measurement pause: HOLD is displayed
- Screen backlight: yes, can be switched on/off
- Auto-off: yes, after 5 minutes of inactivity
- low battery indicator: when the voltage drops to 3.0–3.5V
- battery powered. 160mm x 50mm x 28mm
- Device weight: 116g
- the device is intended for: indoor use
- Operating temperature and humidity: 0°C ~ 40°C (relative humidity less than 80%), 40°C ~ 50°C (relative humidity
-50°C) 2000m
- storage temperature and humidity: -20°C ~ 60°C (relative humidity less than 75%)
Package contents:
- UNI-T UT363 anemometer in blister pack
- 1.5V battery (AAA):- user manual
- 3 pcs. 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 505 mm x 330 mm x 280 mm
- standard gross weight per box: 8.42 kg
MANUFACTURER-TREND.
UNI-T UT191E PRO Line Multimeter
This product comes with a 3-year warranty. UT191E Professional Multimeter
UT191 series professional multimeters designed for industrial users. The UT191’s new function memory retains the most recent mode setting at the next power-up, improving user efficiency.
Applications:
This series of CE/GS/cTUVus-certified multimeters complies with CAT III 600V and has an IP65 rating, suitable for use in damp and dusty environments.
1. Measurement setting saved after power reset
2. IP65, 2 m drop resistance
3. True RMS/peak value measurement
4. Automatic backlight
5. 20A current measurement
6. AC LoZ measurement
Specifications: Range
DC voltage (V): 600V ±(0.5%+3)
AC voltage (V): 600V ±(0.7%+3)
AC LoZ (V): 60+V ACV: 60+V 600V ±(2%+5)
DC current (A): 20A ±(0.8%+3)
AC current (A): 20A ±(1%+3)
Resistance (Ω): 60MΩ ±(0.8%+2)
Capacitance (F)(30%+mF): ±(30%+3) (Hz): 10Hz~1MHz ±(0.1%+4)
Duty cycle: 0.1%~99.9% ±(2%+5)
ACV peak hold ±(2%+100)
Peak current detection ±(3%+100) Display
:
6000-digit display
Sampling rate: 3 times/second
Analogue bar graph: 31-segment graph
True RMS: √
AC voltage frequency response 45Hz–400Hz
AC current frequency response: 45Hz~400Hz
DC diode test:/>Continuity/DC range:/> √
Auto power off: √
Low battery indication: √
Data hold/MAX/MIN: √
Function selection (SELECT): √
Flashlight/Auto light: √
2 m drop test/IP65: √
General: √
General:
Power: 9V battery
LCD size: 58mm x 42mm
Net product weight: 428g
Product colour: red and grey
Product dimensions: 180mm x 87mm x 59mm
Standard accessories: test lead, battery, carrying case, individual gift box
Standard quantity per box: 10 pcs.
Standard box dimensions: 545mm x 315mm x 335mm
Standard box gross weight: 8.8kg
Manufacturer: UNI-TREND