UNI-T Clamp Meters

27 products

  • UNI-T UT208B Clamp Meter

    UNI-T UT208B Clamp Meter

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    UNI-T UT208B Clamp Multimeter This product comes with a 3-year warranty. The UT208B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 100000000000V at 400Hz and low voltage (mn) 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows LV distribution measurements in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only <50μA, which effectively extends battery life. The power-saving function can be disabled. Product specifications: - measurement of AC/DC voltage and current, resistance, diodes, continuity, capacitance - automatic polarity display - Measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range of low-voltage (LV) frequency in the range 10 Hz to 1 MHz - capacitance measurement from 60 nF to 60 mF - Temperature measurement from -40 to +1000 °C with a closed K-type thermocouple - measurement of the (relative) ratio of voltages and voltages and capacitances multiple visual protection voltages greater than 1000 V in ranges - NCV function – non-contact detection of live conductors - LoZ V function ~ measurement with low input impedance (approx. 2 kΩ) of the device - INRUSH function – measurement of transients up to 100 ms – inrush current on device start-up with an additional 3,000,000 loop at the LPF ACV function – AC voltage measurement with an NF filter (approx. 2.5 kHz) on inverters and variable-frequency drives - Frequency/duty cycle measurement function - Choice between automatic or manual switching - Built-in lamp - Accuracy of current and voltage measurement is guaranteed when using the range from 10% to 10%; within 5% of this range, it is necessary to change the range Technical parameters: 1. AC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / 40Hz ~ 400Hz ±(2.0%+9) 600.0A / 0.100A / 40Hz ~ 400Hz ±(2.0%+A)+1 40Hz ~ 400Hz ±(2.0%+5) - the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz - Overload protection at 1000A 2. AC inrush current measurement (ranges / resolution / accuracy): 60.00 A / 0.010 A / 40 Hz ~ 400 Hz ±(10.0% + 10) 600.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 1000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) - overload protection at 1000A with flexible current loop 30.00A / 0.000Hz / 40.010Hz ±(10.0%+10) 300.0A / 0.100A / 40Hz ~ 400Hz ±(10.0%+10) 3000.0A / 1A / 40Hz ~ 400Hz ±(10.0%+10) overload protection -10 3000A 3. DC current measurement (ranges / resolution / accuracy): 60.00A / 0.010A / ±(2.0%+5) 600.0A / 0.100A / ±(2.0%+5) 1000.0A / 1A / ±(2.0%+5) overload protection 2.0%/>-5 1000A 4. AC voltage measurement (range / resolution / accuracy): 6,000V / 0.001V / 40Hz ~ 400Hz ±(1.2%+3) 60.00V / 0.010V / 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3) 60.00 V / 0.010 V / 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V / 40 Hz ~ 400 Hz ±(1.0% + 8) 1000.0V / 1V / 40Hz ~ 400Hz ±(1.0%+8) - frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz - Overload protection at 1000 Vrms - Input impedance approx. 10 MΩ 5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) input overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ 6. AC LPF V (measurement with low input impedance approx. 2 kΩ) (range / resolution / accuracy): 600.0 V / 0.1 V / ±(2.0%+5) 1000.0 V / 1 V / ±(2.0% + 5) - Input overload protection rm approx. 2kΩ 7. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.8%+3) 6,000 V / 0.001 V / ±(0.5%+3) 60.00 V / 0.010 V / 0.010 V / +0.05 V / 0.100 V / ±(0.5%+3) 1000.0 V / 1 V / ±(0.5%+3) - overload protection at 1000Vrms - input impedance approx. 10 MΩ 8. Resistance measurement (range / resolution / accuracy): 600.0Ω / 0.1Ω / ±(1.0%+3) 6,000 kΩ / 0.001 kΩ / ±(1.0% + 2) 60.00 kΩ / 0.01 kΩ / 0.01 kΩ / % + 0.0,0,0,0,0,0,0,0,Ω /> 0.1 kΩ / ±(1.0% + 2) 6,000 MΩ / 0.001 MΩ / ±(2.0%+8) 60.00 MΩ / 0.01 MΩ / ±(2.0%+8) - overload protection at 1000 Vrms open-circuit voltage approx. - 1 V 9. Checking circuit continuity: - if the measured resistance is less than 30Ω, the continuity signal emits a beep - with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep - uncertainty between 31Ω and 69Ω - 600Ω, with a resolution of 0.1Ω - overload protection at 1000 Vrms 10. Diode measurement: - in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V - for a silicon junction, a typical voltage drop is 0.5 to 0.8V - open-circuit voltage of approximately 3.0V - measurement in the 000V range, with a resolution of 6.00 V, 0.001 V 11. Capacitance measurement (range / resolution / accuracy): 60.00 nF / 0.01 nF / ±(4.0%+25) 600.0 nF / 0.1 nF / ±(4.0%+5) 6,000 μF / 0.001 μF ±(4.0%+5) 60.00 μF / 0.01 μF / ±(4.0% + 5) 600.0 μF / 0.1 μF / ±(4.0%+5) 6.000 mF / 0.001 mF / ±10.0% / 0.1 μF / 0.1 μF / ±(4.0%+5) / ±10.0%+9 - overload protection at 1000 Vrms 12. Temperature measurement (ranges / resolution / accuracy): -40°C to +300°C / 0.1°C / ± 1.0°C+20 +300°C to +1000°C / 1°C / ±(1.0%+2) +573°F to +1832°F / 1°F / ±(1.0%+4) 13. Frequency measurement and operating cycle (filling) (ranges / resolution / accuracy): frequency: 10 Hz to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3) Fill: 10% to 99.1% / ±99.0% / ±7) - Note 1) Measurement sensitivity: 10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS 100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS Note: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz: 2Vpp ≤ input amplitude ≤ 20V p-p - overload protection at 1000 Vrms 14. Non-contact electric field sensing (NCV): - allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will start flashing. (ratio) for voltage and capacitance measurement: yes - HOLD: yes - low battery indicator: yes - Auto power off: yes - Power supply: 1.5 V batteries (R03): 2 pcs - Backlit display size: 43 x 45 mm - Product dimensions: 81 x 27/4 x 81 x 27 mm. Product weight: 450g - Product colour: red and grey Package contents: - UT208B clamp multimeter: 1 pc - Test leads: 1 pair - K-type thermocouple up to 1000°C: 1 pc 3: >- (battery 3): user manual: 1 pc Wholesale packaging: - standard quantity per box: 5 pcs - standard box dimensions: 355 mm x 330 mm x 165 mm - standard gross weight per box: 4.5 kg UNI-TREND MANUFACTURE https://www.uni-trend.com/

    10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €150,51

  • Last stock! UNI-T UT202T Clamp Meter

    UNI-T UT202T Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. The UT202T is an easy-to-use smart clamp multimeter that can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values. Capacitance measurement and non-contact voltage measurement (NCV) are selected by pressing buttons. The UT202T features a new design, high reliability and safety, as well as automatic range switching available for all functions. Dual backlit LCD screen, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, current/frequency. There is an LED lamp on the underside of the test leads. It is powered by two 1.5V AAA R03 batteries. The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree. : - measurement of AC/DC voltage, AC current, resistance, capacitance and circuit continuity - measurement of voltage and current frequency on the auxiliary display - Non-contact voltage detection (NCV) - dual LCD display with multi-segment backlight - Audible and visual alarm - protection against voltage ranges exceeding 60 V - switching - accuracy guaranteed between 5% and 100% of the range - built-in LED torch - powered by two 1.5V AAA R03 batteries Technical specifications: To ensure measurement accuracy, the operating temperature must be within the range of 18°C to 28°C 1. AC current measurement (ranges/resolution/accuracy): 9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30) 99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60) - minimum detectable current: 0.01A - frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz - overload protection /> /200 Hz AC voltage measurement (range / resolution / accuracy): 9.999 V / 0.001 V / 40 Hz to 400 Hz ±(0.8%+3) 99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8% + 3) 99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3) - Frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude ≥5Vrms at a frequency from 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified. - Input impedance approx. 10 MΩ - Overload protection at 600 Vrms - Minimum detectable voltage 0.6 V 3. DC voltage measurement (range / resolution / accuracy): 9.999 V / 0.001 V / ±(0.5%+3) 99.99 V / 0.01 V / ±(0.5% + 3) 600 V / 0.1 V / ±(0.5% + 3) input approx. 10 MΩ - overload protection at 600Vrms - minimum detectable voltage 0.6V 4. Resistance measurement (ranges/resolution/accuracy): 999.9Ω / 0.1Ω / ±(0.8%+3) 9.999 kΩ / 0.001 kΩ / ±(0.8% + 3) 99.99 kΩ / 0.01 kΩ / 0.01 kΩ / %+90 kΩ / %+90 kΩ / >±9 kΩ / 0.1 kΩ / ±(0.8%+3) 6,000 MΩ / 0.001 MΩ / ±(1.5%+3) - overload protection at 600 Vrms - open-circuit voltage approx. 1 V 5. Capacitance measurement (ranges/resolution/accuracy): 99.99 nF / 0.01 nF / ±(4.0%+10) 999.9 nF / 0.1 nF / ±(4.0%+10) 9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5) 99.99 μF / 0.01 μF / ±(4.0% + 5) 999.9 μF / 0.1 μF / ±(4.0% + 5) 9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10) - overload protection at 600 Vrms 6. Checking circuit continuity: - If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined. - open-circuit voltage approximately 3.0 V - Overload protection at 600 Vrms 7. Non-contact electric field sensing (NCV): - enables acoustic detection of live conductors using a buzzer and visual detection using an LED Other parameters: - jaw opening: 28 mm - measurement of maximum and minimum values: yes -: data hold indication - low battery - yes, if the battery voltage is less than 2.4V; if the battery voltage is less than approx. 2.2V, the device cannot be switched on - auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required. - Drop resistance: yes, 1 m - Electromagnetic compatibility: RF ≤ 1 V/m, overall accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified - Operating altitude: ≤2000m, operating temperature and humidity: +3/0°C -0°C (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH) - storage temperature and humidity: -20 to +60°C (≤ 80%RH) - recommended calibration interval: 1 year - 1-battery power supply: 5 V–2 V (R03) - Product dimensions: 201.5 × 47 × 28.5 mm - UT202T weight: approx. 241g (including batteries); - Product colour: red and grey Package contents: - UT202T multimeter clip: 1 pc - test leads: 1 pair - 1.5 V battery (R03): 2 pcs - user manual - pcs Wholesale packaging: - standard quantity per box: 40 pcs - standard carton dimensions: 485 x 295 x 385 mm - standard gross weight of carton: approx. 17 kg Manufacturer: UNI-TREND -

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €36,01

  • Last stock! UNI-T UT219P Clamp Meter UNI-T UT219P Clamp Meter

    UNI-T UT219P Clamp Meter

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    This product comes with a 3-year warranty. The UNI-T UT219P is a portable, clamp-on smart power meter. It can measure harmonics, three-phase unbalanced voltage, AC voltage, AC current, power, power factor and much more. It is widely used in photovoltaic power stations, motor manufacturing, electrical equipment and distribution boxes. Product parameters: - 1000A AC current measurement - 1000V AC voltage measurement - AC and DC peak measurement - Three-phase power measurement (3000 kW) - measurement of harmonics/THD/power factor/phase sequence - single-phase power measurement - Large jaw opening (up to 75 mm diameter) - True RMS measurement - Bluetooth 5.0 - CAT III/IV 100,000/CATV0 protection - IP54 Technical parameters: AC current (A): 1000 A ±(1.5%+3) AC voltage (V): 1000 V ± (0.7% + 3) Power (single-phase): 1000 kW ±(1.7%+5) Power (three-phase and 3-wire): 1732 kW Power (three-phase and 4-wire): 3000 kW Power supply frequency (Hz): 15 Hz ~ 1000 Hz ±±3 (Hz angle (0. (-180° ~ 179.9°) 15 Hz–40 Hz ±5° 40 Hz ~ 70 Hz ±3° 70 Hz ~ 1000 Hz ±5° Power factor: -1 to 1 based on phase angle accuracy - 7 mm/> Detection: yes (80V–1000V) / positive and negative - AC/DC PEAK measurement - 32-time harmonic measurement - LCD display - Display range: 9999 - Bluetooth app: yes - True RMS: yes - Overload indication: yes - Overload indication: yes - High-voltage overload warning - Low battery indicator - Data log - Auto-off: approx. 15 minutes - max/min: yes - power supply: 3 x AAA (R03) - dimensions: 295 x 118 x 50 mm - weight: 630 g

    In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

    €246,93

You have seen 27 out of 27 products

© 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

  • American Express
  • Apple Pay
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Union Pay
  • Visa

Login

Forgot your password?

Don't have an account yet?
Create account