This product comes with a 3-year warranty. The UT278A+ from UNI-T is a clamp-on tester for earth resistance. Based on the principle of mutual induction, it can measure earth resistance without disconnecting the earth conductors and without auxiliary electrodes, in both multi-point and single-point earthing systems. Unlike a similar instrument, the UT276A+ has an extended earth loop resistance measurement range up to 1200Ω and can also measure earth loop leakage currents in the range from 0.00 mA to 20.0 A.
The tester is designed for professional use, with resistance to shock, dust and humidity, and is controlled by microprocessors, including for the precise identification of resistance and rapid filtering of interfering signals using advanced arithmetic methods. It is designed for measuring earthing systems in power stations, power distribution and telecommunications, oil fields, computer rooms, electromechanical installations and maintenance in industrial plants, wherever electricity is used as an industrial power source, or where it is necessary to check the earthing resistance of lightning arresters. The device measures earth loop resistance from 0.01 Ω to 1200 Ω with a resolution of 0.001 Ω and leakage currents from 0 to 20 A; the measured values are displayed on a four-digit backlit EBTN display (light-on-dark background) and, at the same time, up to 30 values can be stored in the internal memory. The unit is powered by four 1.5V alkaline batteries.
Manufactured in accordance with safety standard IEC 61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC 61010-031.

Product specifications:

- earth loop resistance measurement range: 0 to 1200Ω
- resolution 0.001 Ω
- Earth loop leakage current measurement range: resolution 0 to
-0.01 mA
- automatic range selection
- 4-digit EBTN display
- Simultaneous display of resistance and current on a single screen
- Resistance limit setting with audible indication of exceedance
- Filtering of interfering signals
- High reliability and durability, dual resistance calibration
automatic
- Resistance/insulation
Capacity to store up to 300 sets of measured data
- Powered by 4 x 1.5V AA alkaline batteries
- low battery indicator

Technical parameters:

- Measurement method: mutual induction
- Earth loop resistance measurement range at a resolution of 1/2000Ω

Earth loop resistance measurement accuracy:
in the 0.01 to 0.099 Ω sub-range: 0.001Ω ± (1% + 0.01Ω)
in the sub-range 0.1 to 0.99 Ω: 0.01 Ω ± (1% + 0.01 Ω)
in the sub-range 0.1 to 0.99 Ω: 0.1 Ω ± (1% + 0.1 Ω)
in the 50 to 99.5 Ω sub-range: 0.5 Ω ± (1.5% + 0.5 Ω)
in the sub-range 100 to 199 Ω: 1 Ω ± (2% + 1 Ω)
in the sub-range: 3 Ω ± 20 Ω: -3 Ω) (5% + 5 Ω)
in the secondary range from 400 to 590 Ω: 10 Ω ± (10% + 10 Ω)
in the secondary range from 600 to 880 Ω: 20 Ω ± (20% + 20 Ω)
in the secondary range from 900% to ±: +200Ω (2300Ω) 30Ω)

- resolution and accuracy of measurements of currents flowing through the ground loop:
in the sub-range 0.00 mA to 9.95 mA: 0.01 mA ± (2.5% + 1 mA)
in the sub-range 10.0 mA to 9.95 mA: 90.0 mA to 9.95 mA: 5 mA)
in the secondary range 100 mA to 300 mA: 1 mA ± (2.5% + 10 mA)
in the secondary range 0.3A to 2.99A: 0.01A ± (2.5% + 0.1A)
in the secondary range 0.3A to 2.99A:
in the secondary range: 0.3–1A: (2.5% + 0.3A)
in the sub-range 10.0A to 20.0A: 0.1A ± (2.5% + 0.5A)

- EBTN display dimensions: 47 x 28.5 mm
- Measurement frequency: 2x/sec - Simultaneous resistance
with clamp
- Simultaneous display on screen
opening: 32 x 55 mm
- Interference signal filter: yes
- visual and audible alarm: yes
- range overlap indication: yes, symbols ‘OL Ω’, ‘L0.01Ω’, ‘OL A’
- indication of excessive interference currents: yes, “Noise”, symbol for data storage
-0.01Ω, power supply: 6V (4 x 1.5 V AA (LR6) batteries)
- current consumption: max. 50mA
- low battery indication: yes
- automatic switch-off: yes, after 5 minutes
- Sheath insulation resistance: more than 20MΩ (500V between circuit and housing)
- voltage resistance: 3700V / RMS AC (between circuit and housing)
- maximum 40 mA external magnetic field
field: <1V/m
- Category: CAT III 300V, CAT IV 150V (IEC61010-1)
- Operating ambient temperature and relative humidity: 23 °C ± 5 °C, humidity <75%
- Tester dimensions L x W x H: 285 x 8 mm Tester weight: 1 x 1 x 1 g
(including batteries)

Contents of individual package:

- UT278A+ tester: 1 pc
- 1Ω and 10Ω test loops (calibration): 1 pc
- 1.5 V / AA (LR6) battery: 4 pcs.
>

Standard packaging quantities per box: 1 pc
- Standard box dimensions: 370 x 110 x 300 mm
- total weight of the box: 2.6 kg

Manufacturer:
https://www.uni-trend.com/

UNI-T UT278A+ meter earth clamp

Product form

This product comes with a 3-year warranty. The UT278A+ from UNI-T is a clamp-on tester for earth resistance. Based on... Read more

10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€456,97 Incl. VAT

SKU: 07720285

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    This product comes with a 3-year warranty. The UT278A+ from UNI-T is a clamp-on tester for earth resistance. Based on the principle of mutual induction, it can measure earth resistance without disconnecting the earth conductors and without auxiliary electrodes, in both multi-point and single-point earthing systems. Unlike a similar instrument, the UT276A+ has an extended earth loop resistance measurement range up to 1200Ω and can also measure earth loop leakage currents in the range from 0.00 mA to 20.0 A.
    The tester is designed for professional use, with resistance to shock, dust and humidity, and is controlled by microprocessors, including for the precise identification of resistance and rapid filtering of interfering signals using advanced arithmetic methods. It is designed for measuring earthing systems in power stations, power distribution and telecommunications, oil fields, computer rooms, electromechanical installations and maintenance in industrial plants, wherever electricity is used as an industrial power source, or where it is necessary to check the earthing resistance of lightning arresters. The device measures earth loop resistance from 0.01 Ω to 1200 Ω with a resolution of 0.001 Ω and leakage currents from 0 to 20 A; the measured values are displayed on a four-digit backlit EBTN display (light-on-dark background) and, at the same time, up to 30 values can be stored in the internal memory. The unit is powered by four 1.5V alkaline batteries.
    Manufactured in accordance with safety standard IEC 61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC 61010-031.

    Product specifications:

    - earth loop resistance measurement range: 0 to 1200Ω
    - resolution 0.001 Ω
    - Earth loop leakage current measurement range: resolution 0 to
    -0.01 mA
    - automatic range selection
    - 4-digit EBTN display
    - Simultaneous display of resistance and current on a single screen
    - Resistance limit setting with audible indication of exceedance
    - Filtering of interfering signals
    - High reliability and durability, dual resistance calibration
    automatic
    - Resistance/insulation
    Capacity to store up to 300 sets of measured data
    - Powered by 4 x 1.5V AA alkaline batteries
    - low battery indicator

    Technical parameters:

    - Measurement method: mutual induction
    - Earth loop resistance measurement range at a resolution of 1/2000Ω

    Earth loop resistance measurement accuracy:
    in the 0.01 to 0.099 Ω sub-range: 0.001Ω ± (1% + 0.01Ω)
    in the sub-range 0.1 to 0.99 Ω: 0.01 Ω ± (1% + 0.01 Ω)
    in the sub-range 0.1 to 0.99 Ω: 0.1 Ω ± (1% + 0.1 Ω)
    in the 50 to 99.5 Ω sub-range: 0.5 Ω ± (1.5% + 0.5 Ω)
    in the sub-range 100 to 199 Ω: 1 Ω ± (2% + 1 Ω)
    in the sub-range: 3 Ω ± 20 Ω: -3 Ω) (5% + 5 Ω)
    in the secondary range from 400 to 590 Ω: 10 Ω ± (10% + 10 Ω)
    in the secondary range from 600 to 880 Ω: 20 Ω ± (20% + 20 Ω)
    in the secondary range from 900% to ±: +200Ω (2300Ω) 30Ω)

    - resolution and accuracy of measurements of currents flowing through the ground loop:
    in the sub-range 0.00 mA to 9.95 mA: 0.01 mA ± (2.5% + 1 mA)
    in the sub-range 10.0 mA to 9.95 mA: 90.0 mA to 9.95 mA: 5 mA)
    in the secondary range 100 mA to 300 mA: 1 mA ± (2.5% + 10 mA)
    in the secondary range 0.3A to 2.99A: 0.01A ± (2.5% + 0.1A)
    in the secondary range 0.3A to 2.99A:
    in the secondary range: 0.3–1A: (2.5% + 0.3A)
    in the sub-range 10.0A to 20.0A: 0.1A ± (2.5% + 0.5A)

    - EBTN display dimensions: 47 x 28.5 mm
    - Measurement frequency: 2x/sec - Simultaneous resistance
    with clamp
    - Simultaneous display on screen
    opening: 32 x 55 mm
    - Interference signal filter: yes
    - visual and audible alarm: yes
    - range overlap indication: yes, symbols ‘OL Ω’, ‘L0.01Ω’, ‘OL A’
    - indication of excessive interference currents: yes, “Noise”, symbol for data storage
    -0.01Ω, power supply: 6V (4 x 1.5 V AA (LR6) batteries)
    - current consumption: max. 50mA
    - low battery indication: yes
    - automatic switch-off: yes, after 5 minutes
    - Sheath insulation resistance: more than 20MΩ (500V between circuit and housing)
    - voltage resistance: 3700V / RMS AC (between circuit and housing)
    - maximum 40 mA external magnetic field
    field: <1V/m
    - Category: CAT III 300V, CAT IV 150V (IEC61010-1)
    - Operating ambient temperature and relative humidity: 23 °C ± 5 °C, humidity <75%
    - Tester dimensions L x W x H: 285 x 8 mm Tester weight: 1 x 1 x 1 g
    (including batteries)

    Contents of individual package:

    - UT278A+ tester: 1 pc
    - 1Ω and 10Ω test loops (calibration): 1 pc
    - 1.5 V / AA (LR6) battery: 4 pcs.
    >

    Standard packaging quantities per box: 1 pc
    - Standard box dimensions: 370 x 110 x 300 mm
    - total weight of the box: 2.6 kg

    Manufacturer:
    https://www.uni-trend.com/

    Recently viewed products

      © 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account