UNI-T UT276A+ earth continuity tester with clamp

Description

This product comes with a 3-year warranty. The UT276A+ from UNI-T is a clamp-on tester for earth resistance. Based on the principle of mutual induction, it can measure earth resistance without disconnecting the earth conductors and without auxiliary electrodes, in both multi-point and single-point earthing systems.
The tester is designed for professional use, with resistance to shocks, dust and humidity, and is controlled by a microprocessor for precise identification of earth resistance, including via the rapid interference filtering method. It is designed for measuring earthing systems in power stations, power distribution and telecommunications, oil fields, computer rooms, electromechanical installations and maintenance in industrial plants, wherever electricity is used as an industrial power source, or where it is necessary to check the earthing resistance of lightning protection systems. The device measures earth loop resistance from 0.01 Ω to 500 Ω with a resolution of 0.001 Ω; the measured values are shown on a four-digit backlit EBTN display (data shown against a dark background). The unit is powered by four 1.5V alkaline batteries.
Manufactured in accordance with safety standard IEC 61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC 61010-031.

Product specifications:

- earth loop resistance measurement range: 0 to 500Ω
- automatic range selection
- resolution 0.001 Ω
- 4-digit EBTN display
- with audible resistance limit setting
- Audible signal when resistance limit is exceeded
- high reliability and durability, double insulation
- automatic calibration, calibration resistance loops
- capacity to store up to 300 sets of measured data
- powered by 4 x 1.5V AA alkaline batteries
- low battery indicator

Technical parameter: method: mutual induction
- earth loop resistance measurement range: 0 to 500Ω

- Measurement resolution and accuracy:
in the sub-range 0.01 to 0.099 Ω: 0.001Ω / ± (1% + 0.01Ω)

in the sub-0.01Ω range: 0.01Ω / ± (1% + 0.01Ω)
in the secondary range from 1 to 49.9 Ω: 0.1 Ω / ± (1% + 0.1 Ω)
in the secondary range from 50 to 99.5 Ω: 0.5 Ω / ± (1.5% + 0.1 Ω to 901 Ω)
in the secondary range from 50 to 99.5 Ω: Ω: 1 Ω / ± (2% + 1 Ω)
in the sub-range 200 to 395 Ω: 5 Ω / ± (5% + 5 Ω)
in the sub-range 400 to 590 Ω: 10 Ω / ± (10% + 10 Ω)

display dimensions: 8-4 TN x 5Ω)

mm
- measurement frequency: 2x / sec
- jaw opening: 32 x 55 mm
- Interference signal filter: yes
- visual and audible alarm: yes
- data storage: yes, for 300 groups
- Display hold (HOLD): yes
V (power supply 4 pcs: 16 V) (LR6)
- current consumption: max. 50mA
- low battery indicator: yes
- Auto-off: yes, after 5 minutes
- Sheath insulation resistance: more than 20 MΩ (500 V between circuit and pack)
- voltage withstand: 3700 V / RMS AC (between circuit and package)
- maximum 40 mA external magnetic field
field: <1V/m
- Category: CAT III 300V, CAT IV 150V (IEC 61010-1)
- Operating ambient temperature and relative humidity: 23°C ± 5°C, humidity <75%
- Tester dimensions L x W x H: 285 mm x 8 mm x 85 mm x 8 mm, 1180 g (including batteries)

Contents of individual package:

- UT276A+ tester: 1 pc
- 1Ω and 10Ω test (calibration) loops: 1 pc
- 1.5 V AA (LR6) battery: 4 pcs.

- standard quantity per box: 1 pc
- standard box dimensions: 370 x 110 x 300 mm
- total weight of the box: 2.6 kg

Manufacturer:
https://www.uni-trend.com/

UNI-T UT276A+ earth continuity tester with clamp

Product form

This product comes with a 3-year warranty. The UT276A+ from UNI-T is a clamp-on tester for earth resistance. Based on... Read more

10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€435,59 Incl. VAT

SKU: 07720284

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    This product comes with a 3-year warranty. The UT276A+ from UNI-T is a clamp-on tester for earth resistance. Based on the principle of mutual induction, it can measure earth resistance without disconnecting the earth conductors and without auxiliary electrodes, in both multi-point and single-point earthing systems.
    The tester is designed for professional use, with resistance to shocks, dust and humidity, and is controlled by a microprocessor for precise identification of earth resistance, including via the rapid interference filtering method. It is designed for measuring earthing systems in power stations, power distribution and telecommunications, oil fields, computer rooms, electromechanical installations and maintenance in industrial plants, wherever electricity is used as an industrial power source, or where it is necessary to check the earthing resistance of lightning protection systems. The device measures earth loop resistance from 0.01 Ω to 500 Ω with a resolution of 0.001 Ω; the measured values are shown on a four-digit backlit EBTN display (data shown against a dark background). The unit is powered by four 1.5V alkaline batteries.
    Manufactured in accordance with safety standard IEC 61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC 61010-031.

    Product specifications:

    - earth loop resistance measurement range: 0 to 500Ω
    - automatic range selection
    - resolution 0.001 Ω
    - 4-digit EBTN display
    - with audible resistance limit setting
    - Audible signal when resistance limit is exceeded
    - high reliability and durability, double insulation
    - automatic calibration, calibration resistance loops
    - capacity to store up to 300 sets of measured data
    - powered by 4 x 1.5V AA alkaline batteries
    - low battery indicator

    Technical parameter: method: mutual induction
    - earth loop resistance measurement range: 0 to 500Ω

    - Measurement resolution and accuracy:
    in the sub-range 0.01 to 0.099 Ω: 0.001Ω / ± (1% + 0.01Ω)

    in the sub-0.01Ω range: 0.01Ω / ± (1% + 0.01Ω)
    in the secondary range from 1 to 49.9 Ω: 0.1 Ω / ± (1% + 0.1 Ω)
    in the secondary range from 50 to 99.5 Ω: 0.5 Ω / ± (1.5% + 0.1 Ω to 901 Ω)
    in the secondary range from 50 to 99.5 Ω: Ω: 1 Ω / ± (2% + 1 Ω)
    in the sub-range 200 to 395 Ω: 5 Ω / ± (5% + 5 Ω)
    in the sub-range 400 to 590 Ω: 10 Ω / ± (10% + 10 Ω)

    display dimensions: 8-4 TN x 5Ω)

    mm
    - measurement frequency: 2x / sec
    - jaw opening: 32 x 55 mm
    - Interference signal filter: yes
    - visual and audible alarm: yes
    - data storage: yes, for 300 groups
    - Display hold (HOLD): yes
    V (power supply 4 pcs: 16 V) (LR6)
    - current consumption: max. 50mA
    - low battery indicator: yes
    - Auto-off: yes, after 5 minutes
    - Sheath insulation resistance: more than 20 MΩ (500 V between circuit and pack)
    - voltage withstand: 3700 V / RMS AC (between circuit and package)
    - maximum 40 mA external magnetic field
    field: <1V/m
    - Category: CAT III 300V, CAT IV 150V (IEC 61010-1)
    - Operating ambient temperature and relative humidity: 23°C ± 5°C, humidity <75%
    - Tester dimensions L x W x H: 285 mm x 8 mm x 85 mm x 8 mm, 1180 g (including batteries)

    Contents of individual package:

    - UT276A+ tester: 1 pc
    - 1Ω and 10Ω test (calibration) loops: 1 pc
    - 1.5 V AA (LR6) battery: 4 pcs.

    - standard quantity per box: 1 pc
    - standard box dimensions: 370 x 110 x 300 mm
    - total weight of the box: 2.6 kg

    Manufacturer:
    https://www.uni-trend.com/

    Recently viewed products

      © 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account