Description
UNI-T UT256A Multimeter
This product comes with a 3-year warranty. The UT256A digital multimeter is a safe and reliable clamp-on meter that can replace a clamp-on multimeter. It has no moving mechanical parts, making it resistant to mechanical failure. The device has a display with a maximum reading of 6000. The use of a Hall-effect probe allows AC current to be measured up to 200A. Using the included test leads, AC and DC voltage, resistance and wire continuity can also be measured; it features a built-in non-contact AC voltage (NCV) sensor and a built-in lamp. It features data hold, automatic and manual range selection, a backlit display, frequency measurement and a low battery indicator. The maximum wire diameter that can be inserted into the clamp is 15 mm. Range overrun is indicated by a red LED, and for NCV by an audible signal. A key advantage is its resistance to drops from a height of up to 2 m. Powered by two 1.5 V AA batteries. These features make the UT256A multimeter a practical tool for the daily work of high-voltage electricians.
Product specifications:
- measurement of AC current up to 200 A and its frequency in the range of 50 Hz to 60 Hz
- AC voltage measurement up to 10 V at 10 Hz to 10 kHz
- DC voltage measurement up to 1000 V
- Resistance measurement up to 60 MΩ
- Line continuity check
- Automatic polarity display
- Option to select automatic or manual range switching
- Built-in lamp
- True RMS value on the backlit LCD display
-
measuring 35 mm x 26 mm
- hold
- powered by two 1.5 V AA batteries
- low battery indicator
- automatic switch-off after 15 minutes (function can be temporarily disabled)
Technical specifications:
AC current measurement range:
- accuracy)
200.0 A / 0.1 A / ± (1.8 % + 2) in the range from 0.2 A to 2.0 A, 50 to 60 Hz
200.0 A / 0.1 A / ± (1.8% + 3) in the range from 2.0 to 6 A, at 50 to 60 Hz
200.0 A / 0.1 A / ± (1.8 % + 5) in the range from 5.0 A to 200 A, 50 to 60 Hz
- the accuracy of frequency monitoring when measuring AC current above 20 A, in the range from 50 to 60 Hz, is ± (0.1% + - 60 Hz) at an overcurrent protection resolution of 0.1% Hz
0. 200 A
- AC voltage measurement:
(ranges / resolution / accuracy)
6,000 V / 0.001 V / ± (1.2% + 3), in the range from 10 Hz to 10 kHz
V / 0.00 ± 2 V / 6% 3), in the range from 10 Hz to 10 kHz
600.0 V / 0.1 V / ± (1.2% + 3), in the range from 10 Hz to 10 kHz
1000.0 V / 1 V / ± (1.2 % + 8), in the range from 1.2 % + 8 kHz, in the range from 10 Hz to 10 kHz
RMS voltage value in the frequency range from 45 Hz to 400 Hz
- the accuracy of frequency monitoring when measuring AC voltage in the range from 10 Hz to 10 kHz is ± (0.1% + 5) at a resolution of 0.01 Hz to 0.01 kHz, with overcurrent protection at amplitudes
- Input impedance approx. 10 MΩ
- DC voltage measurement:
(ranges / resolution / accuracy)
6,000 V / 0.001 V / ± (0.8 % +3)
60.00 V / 0.010 V / ± (0.8 % > V / 60 / 0.8 % > V / 60 / 0.8 % +3) ± (0.8 % +3)
1,000.0 V / 1 V / ± (1.0 % +5)
- overload protection at 1000 Vrms
- input impedance approx. 10 MΩ
- Resistance measurement:
(ranges / resolution / accuracy)
600.0 Ω / 0.1 Ω / ± (1.2 % + 2)
6,000 kΩ / 0.001 kΩ / ± (1.0 %/0.0 Ω / ± 0.0 Ω / ± (1.2 % + 2) 0.01 kΩ / ± (1.0 % + 2)
600.0 kΩ / 0.1 kΩ / ± (1.0 % + 2)
6,000 MΩ / 0.001 MΩ / ± (1.2 % + 2)
60.00 MΩ / 0.001 MΩ / ± (1.2 % + 2)
60.00 MΩ / 0.01 (1.0 % + 2) 5)
- overload protection at 1000 Vrms
- open-circuit voltage approx. 1 V
- Circuit continuity check:
- if the measured resistance is less than 10 Ω, the continuity circuit signal emits a buzzer
- if the measured resistance is greater than 100 Ω, the open-circuit signal does not sound a buzzer
- open-circuit voltage of approximately 1/060 V
-0 V. Ω, with a resolution of 0.1 Ω
- Overload protection at 1000 Vrms
- Non-contact electric field sensing (NCV):
- low voltage detection mode ("EFLo") for voltages <48V
- low voltage detection mode ("EFHi") for voltages >-48V: as the voltage increases, the number of segments on the display increases, the green, yellow and red LEDs flash in succession and an audible signal is emitted
General parameters:
- Operating temperature and ambient humidity: 0 °C ~ 30 °C (≤80% RH), 30 °C ~ 40 °C (≤40% RH), 40 °C ~ 40 °C (≤45% RH)
- Storage temperature and humidity: -20 °C ~ 60 °C (≤80% RH)
- Operating altitude: ≤2000m
- Electromagnetic compatibility: in an RF field of 1 V/m, there is an additional error of 5% of the range; in an RF field >1 V/m, overall accuracy is not specified
- Product dimensions: 217 x 58.8 x 38.5 mm
- net product weight: 251 g
- Product colour: red and grey
- This device is designed in accordance with IEC safety standards EN61010-1, IEC/EN61010-2-033 and EN61326-1 and complies with CAT II 1000V, CAT III 600V, double insulation.
Package contents:
- UT256A clamp multimeter: 1 pair of UT256A test leads: 1 pair of test leads. 1.5 V battery (LR6): 2 pcs
- User manual: 1 pc
Wholesale packaging:
- standard quantity per box: 20 pcs
- Standard box dimensions: 485 x 310 x 205 mm
- Standard gross weight per box: 9 kg
R. UNI-TREND