Description
This product comes with a 3-year warranty. The UT202T is an easy-to-use smart clamp multimeter that can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values.
Capacitance measurement and non-contact voltage measurement (NCV) are selected by pressing buttons. The UT202T features a new design, high reliability and safety, as well as automatic range switching available for all functions. Dual backlit LCD screen, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, current/frequency. There is an LED lamp on the underside of the test leads. It is powered by two 1.5V AAA R03 batteries.
The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree. :
- measurement of AC/DC voltage, AC current, resistance, capacitance and circuit continuity
- measurement of voltage and current frequency on the auxiliary display
- Non-contact voltage detection (NCV)
- dual LCD display with multi-segment backlight
- Audible and visual alarm
- protection against voltage ranges exceeding 60 V
- switching
- accuracy guaranteed between 5% and 100% of the range
- built-in LED torch
- powered by two 1.5V AAA R03 batteries
Technical specifications:
To ensure measurement accuracy, the operating temperature must be within the range of 18°C to 28°C
1. AC current measurement (ranges/resolution/accuracy):
9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60)
- minimum detectable current: 0.01A
- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
- overload protection
/>
/200 Hz
AC voltage measurement (range / resolution / accuracy):
9.999 V / 0.001 V / 40 Hz to 400 Hz ±(0.8%+3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8% + 3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3)
- Frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude ≥5Vrms at a frequency from 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.
- Input impedance approx. 10 MΩ
- Overload protection at 600 Vrms
- Minimum detectable voltage 0.6 V
3. DC voltage measurement (range / resolution / accuracy):
9.999 V / 0.001 V / ±(0.5%+3)
99.99 V / 0.01 V / ±(0.5% + 3)
600 V / 0.1 V / ±(0.5% + 3) input
approx. 10 MΩ
- overload protection at 600Vrms
- minimum detectable voltage 0.6V
4. Resistance measurement (ranges/resolution/accuracy):
999.9Ω / 0.1Ω / ±(0.8%+3)
9.999 kΩ / 0.001 kΩ / ±(0.8% + 3)
99.99 kΩ / 0.01 kΩ / 0.01 kΩ / %+90 kΩ / %+90 kΩ / >±9 kΩ / 0.1 kΩ / ±(0.8%+3)
6,000 MΩ / 0.001 MΩ / ±(1.5%+3)
- overload protection at 600 Vrms
- open-circuit voltage approx. 1 V
5. Capacitance measurement (ranges/resolution/accuracy):
99.99 nF / 0.01 nF / ±(4.0%+10)
999.9 nF / 0.1 nF / ±(4.0%+10)
9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5)
99.99 μF / 0.01 μF / ±(4.0% + 5)
999.9 μF / 0.1 μF / ±(4.0% + 5)
9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10)
- overload protection at 600 Vrms
6. Checking circuit continuity:
- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
- open-circuit voltage approximately 3.0 V
- Overload protection at 600 Vrms
7. Non-contact electric field sensing (NCV):
- enables acoustic detection of live conductors using a buzzer and visual detection using an LED
Other parameters:
- jaw opening: 28 mm
- measurement of maximum and minimum values: yes
-: data hold indication
- low battery
- yes, if the battery voltage is less than 2.4V; if the battery voltage is less than approx. 2.2V, the device cannot be switched on
- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.
- Drop resistance: yes, 1 m
- Electromagnetic compatibility: RF ≤ 1 V/m, overall accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified
- Operating altitude: ≤2000m, operating temperature and humidity: +3/0°C
-0°C (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
- storage temperature and humidity: -20 to +60°C (≤ 80%RH)
- recommended calibration interval: 1 year
- 1-battery power supply: 5 V–2 V (R03)
- Product dimensions: 201.5 × 47 × 28.5 mm
- UT202T weight: approx. 241g (including batteries);
- Product colour: red and grey
Package contents:
- UT202T multimeter clip: 1 pc
- test leads: 1 pair
- 1.5 V battery (R03): 2 pcs
- user manual
- pcs
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard carton dimensions: 485 x 295 x 385 mm
- standard gross weight of carton: approx. 17 kg
Manufacturer: