UNI-T UT202BT Clamp Meter

Description

This product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values.
Capacitance measurement and non-contact voltage detection (NCV) are selected by pressing buttons. The UT202BT features a new design, high reliability and safety, as well as automatic range switching available for all functions. The dual backlit LCD display, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, and current/frequency.
There is an LED light on the underside of the test leads. It is powered by two 1.5V R03 AAA batteries.
The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree.

Parameters:

- measurement of AC/DC voltage, AC current, resistance, capacitance, temperature and circuit continuity
- Measurement of voltage and current frequency on the auxiliary display
- Non-contact electric field sensor (NCV)
- Dual LCD display with multi-segment backlight
- Increased acoustic and visual protection against voltages of 60V and above
- Automatic range switching
- Accuracy guaranteed within the range of 5% to 100% of the ranges
- Built-in LED torch
- Powered by two 1.5V AAA R03 batteries

Technical parameters:

To ensure measurement accuracy, operating temperature range: -18°C to 28°C

1a. AC current measurement (ranges/resolution/accuracy):

9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60)
- minimum detectable current: 0.01A
- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
- Overload protection at 60 Hz/>
AC current measurement - LPF (range / resolution / accuracy):

6000A / 0.1A / 50Hz to 60Hz ±(4.0%+5) / 600A rms

1c. AC trip current measurement (range / resolution / accuracy):

99.99A / 0.01A / 50Hz to 60Hz ±(10%+10) / 600A rms
6000A / 0.1A / 50Hz ±0% / 60Hz ±60Hz rms

2a. AC voltage measurement (range / resolution / accuracy):

9.999V / 0.001V / 40Hz to 400Hz ±(0.8%+3)
99.99V / 0.010V / 40Hz to 400Hz ±(0.8%+3)
99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3)
- The frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.
- Input impedance approx. 10 MΩ
- Overload protection at 600Vrms
- Minimum detectable voltage 0.6V

2b. AC-LPF voltage measurement (range / resolution / accuracy):

600 V / 0.1 V / 40 Hz to 400 Hz ±(2.0%+5) / 600 V rms

3. DC voltage measurement (range / resolution / accuracy):

9.999 V / 0.001 V / ±(0.5%+3)
99.99V / 0.01V / ±(0.5%+3)
600V / 0.1V / ±(0.5%+3) input
approx. 10MΩ
- overload protection at 600Vrms
- minimum detectable voltage 0.6V

4. Resistance measurement (ranges/resolution/accuracy):

999.9Ω / 0.1Ω / ±(0.8%+3)
9.999 kΩ / 0.001 kΩ / ±(0.8% + 3)
99.99kΩ / 0.01kΩ / 0.01kΩ /%+90kΩ /%+90kΩ />±9kΩ / 0.1kΩ / ±(0.8%+3)
9.999 MΩ / 0.001 MΩ / ±(1.5%+3)
99.99 MΩ / 0.01 MΩ / ±(2.0%+5)
- overload protection at 600 Vrms open-circuit voltage approx.
- 1V

5. Capacitance measurement (ranges/resolution/accuracy):

99.99 nF / 0.01 nF / ±(4.0%+10)
999.9 nF / 0.1 nF / ±(4.0%+10)
9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5)
99.99 μF / 0.01 μF / ±(4.0% + 5)
999.9 μF / 0.1 μF / ±(4.0% + 5)
9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10)
- overload protection at 600 Vrms

6. Checking circuit continuity:

- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
- open-circuit voltage approx. 3.0 V
- Overload protection at 600 Vrms

7. Temperature measurement:

-40°C~1000°C / ±(2.0%+5)

8. Non-contact electric field sensing (NCV):
- enables acoustic detection of live conductors using a buzzer and optical detection using an LED

Other parameters:

- jaw opening: 28mm
- measurement of maximum and minimum values: yes
- yes
- Yes, data hold, low battery indication (H/>>- and low data: battery voltage is less than 2.4 V; if the battery voltage is less than approx. 2.2 V, the device cannot be switched on
- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.
- Drop resistance: yes, 1 m
- Electromagnetic compatibility: RF ≤ 1 V/m, general accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified
- Operating altitude: ≤ 2000m and operating humidity <3000m
-: (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
- storage temperature and humidity: -20 to +60°C (≤ 80%RH)
- recommended calibration interval: 1 year
- 1-battery power supply: 5 V–2 V (R03)
- product dimensions: 201.5 × 47 × 28.5 mm
- Weight: approx. 241 g (including batteries);
- product colour: red and grey

Package contents:

- UT202BT clamp multimeter: 1 pc
- test leads: 1 pair
- temperature probe (K): 1 pc
- 2 x R03 instruction manuals
- User manual: 1 copy

Manufacturer: UNI-TREND

UNI-T UT202BT Clamp Meter

Product form

This product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically... Read more

In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€54,08 Incl. VAT

SKU: 07720294

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    This product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically detect the most common parameters – AC/DC voltage, AC current, resistance and continuity. It displays true RMS values.
    Capacitance measurement and non-contact voltage detection (NCV) are selected by pressing buttons. The UT202BT features a new design, high reliability and safety, as well as automatic range switching available for all functions. The dual backlit LCD display, with a maximum display value of ±9999, can simultaneously display voltage/current, voltage/frequency, and current/frequency.
    There is an LED light on the underside of the test leads. It is powered by two 1.5V R03 AAA batteries.
    The multimeter is designed in accordance with safety standards EN61010-1/61010-2-032 and electromagnetic compatibility standards EN61326-1/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree.

    Parameters:

    - measurement of AC/DC voltage, AC current, resistance, capacitance, temperature and circuit continuity
    - Measurement of voltage and current frequency on the auxiliary display
    - Non-contact electric field sensor (NCV)
    - Dual LCD display with multi-segment backlight
    - Increased acoustic and visual protection against voltages of 60V and above
    - Automatic range switching
    - Accuracy guaranteed within the range of 5% to 100% of the ranges
    - Built-in LED torch
    - Powered by two 1.5V AAA R03 batteries

    Technical parameters:

    To ensure measurement accuracy, operating temperature range: -18°C to 28°C

    1a. AC current measurement (ranges/resolution/accuracy):

    9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
    99.99A / 0.01A / 50Hz to 60Hz ±(2.5% /+60)
    - minimum detectable current: 0.01A
    - frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
    - Overload protection at 60 Hz/>
    AC current measurement - LPF (range / resolution / accuracy):

    6000A / 0.1A / 50Hz to 60Hz ±(4.0%+5) / 600A rms

    1c. AC trip current measurement (range / resolution / accuracy):

    99.99A / 0.01A / 50Hz to 60Hz ±(10%+10) / 600A rms
    6000A / 0.1A / 50Hz ±0% / 60Hz ±60Hz rms

    2a. AC voltage measurement (range / resolution / accuracy):

    9.999V / 0.001V / 40Hz to 400Hz ±(0.8%+3)
    99.99V / 0.010V / 40Hz to 400Hz ±(0.8%+3)
    99.99 V / 0.010 V / 40 Hz to 400 Hz ±(0.8%/+3) 40 Hz to 400 Hz ±(0.8%+3)
    - The frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.
    - Input impedance approx. 10 MΩ
    - Overload protection at 600Vrms
    - Minimum detectable voltage 0.6V

    2b. AC-LPF voltage measurement (range / resolution / accuracy):

    600 V / 0.1 V / 40 Hz to 400 Hz ±(2.0%+5) / 600 V rms

    3. DC voltage measurement (range / resolution / accuracy):

    9.999 V / 0.001 V / ±(0.5%+3)
    99.99V / 0.01V / ±(0.5%+3)
    600V / 0.1V / ±(0.5%+3) input
    approx. 10MΩ
    - overload protection at 600Vrms
    - minimum detectable voltage 0.6V

    4. Resistance measurement (ranges/resolution/accuracy):

    999.9Ω / 0.1Ω / ±(0.8%+3)
    9.999 kΩ / 0.001 kΩ / ±(0.8% + 3)
    99.99kΩ / 0.01kΩ / 0.01kΩ /%+90kΩ /%+90kΩ />±9kΩ / 0.1kΩ / ±(0.8%+3)
    9.999 MΩ / 0.001 MΩ / ±(1.5%+3)
    99.99 MΩ / 0.01 MΩ / ±(2.0%+5)
    - overload protection at 600 Vrms open-circuit voltage approx.
    - 1V

    5. Capacitance measurement (ranges/resolution/accuracy):

    99.99 nF / 0.01 nF / ±(4.0%+10)
    999.9 nF / 0.1 nF / ±(4.0%+10)
    9.999 nF / 0.001 μF / 0.001 μF ±(4.0%+5)
    99.99 μF / 0.01 μF / ±(4.0% + 5)
    999.9 μF / 0.1 μF / ±(4.0% + 5)
    9.999 mF / 0.001 mF / ±(10.001 mF / ±/+10.001 mF / ±/+10.09%/+5) 0.1 mF / ±(10.0%+10)
    - overload protection at 600 Vrms

    6. Checking circuit continuity:

    - If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
    - open-circuit voltage approx. 3.0 V
    - Overload protection at 600 Vrms

    7. Temperature measurement:

    -40°C~1000°C / ±(2.0%+5)

    8. Non-contact electric field sensing (NCV):
    - enables acoustic detection of live conductors using a buzzer and optical detection using an LED

    Other parameters:

    - jaw opening: 28mm
    - measurement of maximum and minimum values: yes
    - yes
    - Yes, data hold, low battery indication (H/>>- and low data: battery voltage is less than 2.4 V; if the battery voltage is less than approx. 2.2 V, the device cannot be switched on
    - auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.
    - Drop resistance: yes, 1 m
    - Electromagnetic compatibility: RF ≤ 1 V/m, general accuracy = stated accuracy ±5% of the range; if RF > 1 V/m, accuracy is not specified
    - Operating altitude: ≤ 2000m and operating humidity <3000m
    -: (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
    - storage temperature and humidity: -20 to +60°C (≤ 80%RH)
    - recommended calibration interval: 1 year
    - 1-battery power supply: 5 V–2 V (R03)
    - product dimensions: 201.5 × 47 × 28.5 mm
    - Weight: approx. 241 g (including batteries);
    - product colour: red and grey

    Package contents:

    - UT202BT clamp multimeter: 1 pc
    - test leads: 1 pair
    - temperature probe (K): 1 pc
    - 2 x R03 instruction manuals
    - User manual: 1 copy

    Manufacturer: UNI-TREND

    Recently viewed products