UNI-T UT171B multimeter

Description

UNI-T UT171B Multimeter
The UT171 series multimeters are portable multimeters with automatic and manual range switching and a resolution of 4 3/4 to 4 5/6 digits. These devices belong to the upper mid-range class, excel in quality design and reliability, and are also suitable for industrial use. They can measure AC/DC voltage and current, resistance, diode test, continuity test, capacitance, frequency, duty cycle, temperature, 4-20mA current loop, conductivity, VFC, and NCV. The devices allow data storage and connection via USB with optical isolation or via Bluetooth.

UNI-T UT171B Multimeter
Unlike the UT171A, the UT171B has a wider range for resistance and capacitance measurements and also measures conductivity (reverse resistance). The display type is VT-WLCD, with data displayed in bright text on a dark background. The display range is ±60,000 for voltages, currents and frequencies, and ±6,000 for capacitance measurements. The display includes a 31-segment analogue bar graph. Refresh rate of 4 to 5 times per second. The fuses are protected by tubular fuses (10A FF 10A H / 1000V fuse (10 x 38mm); mA/µA FF 800mA H / 600V fuse (6 x 32mm)). The device can test its own fuses (without opening the device). The multimeter is powered by a 7.4 V / 1800 mAh lithium battery. The measurement range can be selected automatically or manually. Test leads with tips in safety categories CAT III 1000V and CAT IV 600V are included.

Product specifications:

- fully compliant with IEC / EN61010-1 and feature double insulation
- classified as CAT III 1000V - electrical installation including three-phase distribution
- classified as CAT IV 600V - outdoor electrical installation (fuse boxes, start of internal installation)
- maximum display is 60,000, VT-WLCD reverse display
- Frequency measurement display 60,000
- Capacitance measurement display 6000
- Refresh rate for most measurements: 4 to 5 times per second
- Automatic voltage measurement range
- 600 mV / 1000 V
- AC current measurement ranges: 600 μA / 10 A
- DC voltage measurement ranges: 600 mV / 1000 V
- DC current measurement ranges: 600 μA / 10 A
- Voltage measurement range: 600 mV / 1000 V
- MΩ
- Capacitance measurement ranges: 60.00 nF / 60.00 mF
- Measurement ranges: 60 Hz to 10 MHz
- Duty cycle measurement range
- Conductance measurement range: 60 nS
- Temperature measurement range: °C ~ -10,000 °C (nickel-chromium-nickel-silicon thermocouple only up to +230 °C)
- High accuracy
- Analogue bar graph scale, 31 divisions
- TRMS, measurement of rms voltage, AC voltage and currents
- During AC voltage measurement, the frequency or duty cycle of the voltage can be measured on the secondary display
- On the secondary display, it is also possible to measure the AC component superimposed on DC voltage
- Data logging of 1000 values
- Relative measurement mode
- measurement of MAX and 1 MIN peak response
Faulty wiring
- Low battery indicator
- Auto-off (sleep mode when inactive)
- Overload protection for voltage inputs
- Overvoltage protection on inputs with fast-acting fuses
- 10MΩ input impedance
- Non-contact voltage detection without test probes
- Semiconductor transition to diodes and 3V voltage test semiconductors
- Powered by a 7.4V / 1800mAh Li-ion battery
- USB cable supplied with opto-electrical converter; software can be downloaded from the manufacturer’s website: https://meters.uni-trend.com/product/ut171-series/#Docs
- Supplied with a 50 V DC power supply / option for 10 V DC power supply
via the UT-D08 Bluetooth adapter
- measurement in electromagnetic fields with an intensity of 1 V/m is also possible, with an additional error of 5%

Technical parameters:
(accuracy is defined at a temperature of 23°C ± 5°C and relative humidity less than or equal to 75%)

- DC voltage measurement (input impedance) is 10 MΩ:
(range / resolution / accuracy)
600.00 mV / 10 µV / ± 0.025% + 5
6.0000 V / 0.1 mV / ± 0.025 % + 5
+ 5
600.00 V / 10 mV / ± 0.03 % + 5
1000.0 V / 100 mV / ± 0.03% + 5

- AC voltage measurement (input impedance approx. 10M, 45 Hz) 45 Hz 45 Hz (range / resolution / accuracy)
600.00 mV / 10 µV / ± 0.4 % + 40
6.0000 V / 0.1 mV / ± 0.025% + 5
60.000 V / 1 mV / ± 0.000 V / 0.1 mV / ± 0.1 mV / ± 0.025 % + 5
60.000 V / 1 mV / ± 5 % / 0.50 × 10 mV / ± 0.03 % + 5
1000.0 V / 100 mV / ± 0.03% + 5
LoZ 100.0 V / 0.1 V / ± 2.0 % + 10
V.F.C. 600 V/1000 V / 0.01 V/0.1 V / ± 2.0 % + 10

- DC measurement:
(range / resolution / accuracy)
600.0 μA / 0.01 μA / ± 0.02% / ± 0.02 μA / ± 0.02%. μA / 0.1 μA / ± 0.25% + 2
60,000 mA / 1 μA / ± 0.7 % + 2
600.0 mA / 10 μA / ± 0.15% + 2
6,000 A / ± 3,000 mA / ± 3.0 % + 2
10,000 A / 1 mA / ± 0.5 % + 2
% (4–20 mA) / 0.01% / ± 0.5% + 2

- AC current measurement (45 Hz to 1 kHz):
0 / hour > resolution 0 / 0 μA / hour / 0.01 μA / ± 0.75% + 20
6000.0 μA / 0.1 μA / ± 0.75 % + 20
60,000 mA / 1 μA / ± 0.75% + 20
600,000
6.0000 A / 0.1 mA / ± 1.5 % + 20
10,000 A / 1 mA / ± 1.5 % + 5

- Resistance and conductivity measurement:
/00000 A / 1 mA / ± 1.5 % + 5

- Resistance and conductivity measurement:
/0000000 A / 0 / 00000 A / 0.01 Ω / ± 0.05 % + 10
6.0000 kΩ / 0.1 Ω / ± 0.05% + 2
60,000 kΩ / 1 Ω / ± 0.05 % + 2
600.00 kΩ / ± 20.00 kΩ / ± 2. 6,000.00 MΩ / 100 Ω / ± 0.15% + 5
60,000 MΩ / 1 kΩ / ± 3 % + 2
60.00 nS / 0.01 nS / ± 1 % + 10 (S = Siemens unit of capacitance)

(range / resolution / accuracy)
6,000 nF / 1 pF / ± 3.0% + 30
60.00 nF to 600.0 µF / 10 pF to ± 5.0 nF / ± 5.0 pF / ± 1. 6.000 µF to 60.00 µF / 1 µF to 10 µF / ± 10 %

- Frequency and duty cycle measurement:
(range / resolution / accuracy H 60)
0. 10,000 MHz / 0.0001 Hz to 0.001 MHz / ± 0.01 % + 5
0.1% to 99.9% / 0.1% / ± 3.0% + 40
100.0 ms to 0.100 µs / ± 0.100 µs / µs / ± 3.0 % + 40 0.1 % + 5

- display type: inverted backlit VT-WLCD
- sampling frequency: 4 to 5/sec
- number of digits: 60,000
- analogue display: 31 segments
- power supply: LiIon battery 7/18–40 mAh
18–40 mAh safety fuse FF 10A H / 1000V (10 x 38mm)
- mA/µA protection: FF 800mA H / 1000V fuse (6 x 32mm)
- instrument dimensions: 206 x 95 x 53 mm
- weight: approx. 500 g (including batteries)
- operating temperature: 0 °C to 40 °C
- relative operating humidity: 0 °C to 30 °C ≤ 75%, 30 °C to 40 °C ≤ 50%
- device storage temperature: -5/10 °C :
cETLus, CAT III 1000V, CAT IV 600V, double insulation, overvoltage protection greater than 1000V
EN 61326-1: 2013; EN 61326-2-2: 2013
EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012
Compliant with UL STD.: 61010-1, 61010-2-030
Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033

- Manufacturer: UNI-TREND
-

Package contents:

- UT171B, storage case and Li-Ion-7 multimeter with 1800mAh battery - in device
- Fuse F1: 6 x 32mm FF 800mA H 1000V (6 x 32mm) – in the device
- Fuse F2: 6 x 25mm FF 10A H 1000V (10 x 38mm) – in the device
-- USB cable with optical converter
- Type K thermocouple (nickel-chromium-nickel-silicon) up to +230 °C
- Test leads with CAT III 1000V, CAT IV 600V tips
- DC 10V / 500mA power supply with accessories
- user manual in Czech/Slovak/English

UNI-T UT171B multimeter

Product form

UNI-T UT171B Multimeter The UT171 series multimeters are portable multimeters with automatic and manual range switching and a resolution of... Read more

10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€255,31 Incl. VAT

SKU: 07720190

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    UNI-T UT171B Multimeter
    The UT171 series multimeters are portable multimeters with automatic and manual range switching and a resolution of 4 3/4 to 4 5/6 digits. These devices belong to the upper mid-range class, excel in quality design and reliability, and are also suitable for industrial use. They can measure AC/DC voltage and current, resistance, diode test, continuity test, capacitance, frequency, duty cycle, temperature, 4-20mA current loop, conductivity, VFC, and NCV. The devices allow data storage and connection via USB with optical isolation or via Bluetooth.

    UNI-T UT171B Multimeter
    Unlike the UT171A, the UT171B has a wider range for resistance and capacitance measurements and also measures conductivity (reverse resistance). The display type is VT-WLCD, with data displayed in bright text on a dark background. The display range is ±60,000 for voltages, currents and frequencies, and ±6,000 for capacitance measurements. The display includes a 31-segment analogue bar graph. Refresh rate of 4 to 5 times per second. The fuses are protected by tubular fuses (10A FF 10A H / 1000V fuse (10 x 38mm); mA/µA FF 800mA H / 600V fuse (6 x 32mm)). The device can test its own fuses (without opening the device). The multimeter is powered by a 7.4 V / 1800 mAh lithium battery. The measurement range can be selected automatically or manually. Test leads with tips in safety categories CAT III 1000V and CAT IV 600V are included.

    Product specifications:

    - fully compliant with IEC / EN61010-1 and feature double insulation
    - classified as CAT III 1000V - electrical installation including three-phase distribution
    - classified as CAT IV 600V - outdoor electrical installation (fuse boxes, start of internal installation)
    - maximum display is 60,000, VT-WLCD reverse display
    - Frequency measurement display 60,000
    - Capacitance measurement display 6000
    - Refresh rate for most measurements: 4 to 5 times per second
    - Automatic voltage measurement range
    - 600 mV / 1000 V
    - AC current measurement ranges: 600 μA / 10 A
    - DC voltage measurement ranges: 600 mV / 1000 V
    - DC current measurement ranges: 600 μA / 10 A
    - Voltage measurement range: 600 mV / 1000 V
    - MΩ
    - Capacitance measurement ranges: 60.00 nF / 60.00 mF
    - Measurement ranges: 60 Hz to 10 MHz
    - Duty cycle measurement range
    - Conductance measurement range: 60 nS
    - Temperature measurement range: °C ~ -10,000 °C (nickel-chromium-nickel-silicon thermocouple only up to +230 °C)
    - High accuracy
    - Analogue bar graph scale, 31 divisions
    - TRMS, measurement of rms voltage, AC voltage and currents
    - During AC voltage measurement, the frequency or duty cycle of the voltage can be measured on the secondary display
    - On the secondary display, it is also possible to measure the AC component superimposed on DC voltage
    - Data logging of 1000 values
    - Relative measurement mode
    - measurement of MAX and 1 MIN peak response
    Faulty wiring
    - Low battery indicator
    - Auto-off (sleep mode when inactive)
    - Overload protection for voltage inputs
    - Overvoltage protection on inputs with fast-acting fuses
    - 10MΩ input impedance
    - Non-contact voltage detection without test probes
    - Semiconductor transition to diodes and 3V voltage test semiconductors
    - Powered by a 7.4V / 1800mAh Li-ion battery
    - USB cable supplied with opto-electrical converter; software can be downloaded from the manufacturer’s website: https://meters.uni-trend.com/product/ut171-series/#Docs
    - Supplied with a 50 V DC power supply / option for 10 V DC power supply
    via the UT-D08 Bluetooth adapter
    - measurement in electromagnetic fields with an intensity of 1 V/m is also possible, with an additional error of 5%

    Technical parameters:
    (accuracy is defined at a temperature of 23°C ± 5°C and relative humidity less than or equal to 75%)

    - DC voltage measurement (input impedance) is 10 MΩ:
    (range / resolution / accuracy)
    600.00 mV / 10 µV / ± 0.025% + 5
    6.0000 V / 0.1 mV / ± 0.025 % + 5
    + 5
    600.00 V / 10 mV / ± 0.03 % + 5
    1000.0 V / 100 mV / ± 0.03% + 5

    - AC voltage measurement (input impedance approx. 10M, 45 Hz) 45 Hz 45 Hz (range / resolution / accuracy)
    600.00 mV / 10 µV / ± 0.4 % + 40
    6.0000 V / 0.1 mV / ± 0.025% + 5
    60.000 V / 1 mV / ± 0.000 V / 0.1 mV / ± 0.1 mV / ± 0.025 % + 5
    60.000 V / 1 mV / ± 5 % / 0.50 × 10 mV / ± 0.03 % + 5
    1000.0 V / 100 mV / ± 0.03% + 5
    LoZ 100.0 V / 0.1 V / ± 2.0 % + 10
    V.F.C. 600 V/1000 V / 0.01 V/0.1 V / ± 2.0 % + 10

    - DC measurement:
    (range / resolution / accuracy)
    600.0 μA / 0.01 μA / ± 0.02% / ± 0.02 μA / ± 0.02%. μA / 0.1 μA / ± 0.25% + 2
    60,000 mA / 1 μA / ± 0.7 % + 2
    600.0 mA / 10 μA / ± 0.15% + 2
    6,000 A / ± 3,000 mA / ± 3.0 % + 2
    10,000 A / 1 mA / ± 0.5 % + 2
    % (4–20 mA) / 0.01% / ± 0.5% + 2

    - AC current measurement (45 Hz to 1 kHz):
    0 / hour > resolution 0 / 0 μA / hour / 0.01 μA / ± 0.75% + 20
    6000.0 μA / 0.1 μA / ± 0.75 % + 20
    60,000 mA / 1 μA / ± 0.75% + 20
    600,000
    6.0000 A / 0.1 mA / ± 1.5 % + 20
    10,000 A / 1 mA / ± 1.5 % + 5

    - Resistance and conductivity measurement:
    /00000 A / 1 mA / ± 1.5 % + 5

    - Resistance and conductivity measurement:
    /0000000 A / 0 / 00000 A / 0.01 Ω / ± 0.05 % + 10
    6.0000 kΩ / 0.1 Ω / ± 0.05% + 2
    60,000 kΩ / 1 Ω / ± 0.05 % + 2
    600.00 kΩ / ± 20.00 kΩ / ± 2. 6,000.00 MΩ / 100 Ω / ± 0.15% + 5
    60,000 MΩ / 1 kΩ / ± 3 % + 2
    60.00 nS / 0.01 nS / ± 1 % + 10 (S = Siemens unit of capacitance)

    (range / resolution / accuracy)
    6,000 nF / 1 pF / ± 3.0% + 30
    60.00 nF to 600.0 µF / 10 pF to ± 5.0 nF / ± 5.0 pF / ± 1. 6.000 µF to 60.00 µF / 1 µF to 10 µF / ± 10 %

    - Frequency and duty cycle measurement:
    (range / resolution / accuracy H 60)
    0. 10,000 MHz / 0.0001 Hz to 0.001 MHz / ± 0.01 % + 5
    0.1% to 99.9% / 0.1% / ± 3.0% + 40
    100.0 ms to 0.100 µs / ± 0.100 µs / µs / ± 3.0 % + 40 0.1 % + 5

    - display type: inverted backlit VT-WLCD
    - sampling frequency: 4 to 5/sec
    - number of digits: 60,000
    - analogue display: 31 segments
    - power supply: LiIon battery 7/18–40 mAh
    18–40 mAh safety fuse FF 10A H / 1000V (10 x 38mm)
    - mA/µA protection: FF 800mA H / 1000V fuse (6 x 32mm)
    - instrument dimensions: 206 x 95 x 53 mm
    - weight: approx. 500 g (including batteries)
    - operating temperature: 0 °C to 40 °C
    - relative operating humidity: 0 °C to 30 °C ≤ 75%, 30 °C to 40 °C ≤ 50%
    - device storage temperature: -5/10 °C :
    cETLus, CAT III 1000V, CAT IV 600V, double insulation, overvoltage protection greater than 1000V
    EN 61326-1: 2013; EN 61326-2-2: 2013
    EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012
    Compliant with UL STD.: 61010-1, 61010-2-030
    Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033

    - Manufacturer: UNI-TREND
    -

    Package contents:

    - UT171B, storage case and Li-Ion-7 multimeter with 1800mAh battery - in device
    - Fuse F1: 6 x 32mm FF 800mA H 1000V (6 x 32mm) – in the device
    - Fuse F2: 6 x 25mm FF 10A H 1000V (10 x 38mm) – in the device
    -- USB cable with optical converter
    - Type K thermocouple (nickel-chromium-nickel-silicon) up to +230 °C
    - Test leads with CAT III 1000V, CAT IV 600V tips
    - DC 10V / 500mA power supply with accessories
    - user manual in Czech/Slovak/English

    Recently viewed products

      © 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account