UNI-T A25D PM2.5 Monitor

Description

UNI-T A25D PM2.5 Monitor
This product comes with a 3-year warranty. The A25D is an office air quality monitor used to monitor PM2.5 concentrations in homes, shopping centres, offices, stations, etc. PM2.5 particles are air pollutants with a diameter of 2.5 µm or less, containing soot, smoke, metals, nitrates, sulphates, dust, water and tyre rubber.
When we breathe, PM2.5 can reach deep into our lungs, and some particles can even enter the bloodstream. Exposure to fine particles can affect the heart and lungs.

Product specifications:

- real-time measurement of PM2.5 concentration
- Temperature and relative humidity measurement
- Built-in LiPo battery
- 3 hours to fully charge; can also be used whilst charging
- PM2.5 display,
- If the limit (μg/m³) is exceeded, the backlight turns red
- In addition to exact values and guidance emojis

Technical specifications:

PM2.5 measurement (μg/m³):
- range 0 to 100 ± (10 μg/dm³) +10 μg/dm³ +10 μg/dm³ 8 +10 μg/m³ 1 ± ambient temperature / ambient humidity: 40% to 75% RH
- range 101 to 400 ± (10% + 30 dgts) / Ambient temperature: 18 to 28 °C / Ambient humidity: 40% to 75% RH
- range 401 to 500 ± (10% + 30 digits) / 5 (10% to 28 °C) / ambient humidity: 40% to 75% RH

Temperature measurement °C: -10 °C to +50 °C (0.1 °C/±1 °C)
Humidity measurement: 0 to 99% RH (1% RH) / at ambient temperature 18 to 28 °C
Backlit LCD display: 42 mm x 65 mm
Weight: 230 g
Dimensions: 75 mm x 55 mm x 130 mm

Operating environment:
- for indoor and outdoor environments or vehicles
- Operating altitude: below 2,000 metres at 50 °C; Operating humidity: 0 to 99% RH

Package contents
- UNI-T A25D measuring instrument
- charging cable
- user manual
 

/>

/>

 


/>

/>

parameters:

1. Technical specifications:

Operation / Range / Resolution / Accuracy / Note

PM2.5 / 0 to 500μg/m³ / 1μg/m³ / ±(10μg/m³ + 10dgts) / Ambient temperature: 18 to 28°C / Ambient humidity
40% to :> 40% RH Range 100μg/m³

PM2.5 / 0 to 500μg/m³ / 1μg/m³ / ±(10% + 30dgts) / Ambient temperature: 18 to 28°C / Ambient humidity: 40% to 75%RH
@ 101% to 40μg/m³
0 to 500μg/m³ / 1μg/m³ / ±(10% + 50dgts) / Ambient temperature: 18 to 28°C / Ambient humidity: 40% to 75%RH
@ 401 to 500 μg/m³ range

Temperature / -10°C / -10°C / -10°C ±1°C

Humidity / 0 to 99%RH / 1%RH / ±5%RH @30% to 80%RH / Temperature 18°C to 28°C

Humidity / 0 to 99% RH / 1% RH / ±8% RH @ less than 30% RH / temperature less than 30% RH / more

80%RH

2. PM 2.5 Concentration assessment emoticons

Concentration Emoji Backlight
(μg/m³)
0 to 35 White excellent
36 to 75 White – Good
76 to 115 Light pollution White
116 to 150 Red Pollution level 151 to 250 Severe pollution Red
251 to 500 Severe pollution red

3. General features

- powered by a built-in 1500mAh LiPo battery
- 42mm x 65mm backlit LCD display, alarm - red backlight
- Weight 230g
- external dimensions 75mm x 55mm x 130mm
- operating principle: PM2.5 -/>
- altitude: less than or equal to 2000 metres
- operating temperature: -10 to +50 °C; operating humidity: 0 to 99% RH
- Storage temperature: -20 to 60 °C

Package contents:

- UNI-T A25D measuring instrument
- µUSB-USB charging cable
- User manual in Czech and English

UNI-T A25D PM2.5 Monitor

Product form

UNI-T A25D PM2.5 Monitor This product comes with a 3-year warranty. The A25D is an office air quality monitor used... Read more

10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€69,17 Incl. VAT

SKU: 07760225

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    UNI-T A25D PM2.5 Monitor
    This product comes with a 3-year warranty. The A25D is an office air quality monitor used to monitor PM2.5 concentrations in homes, shopping centres, offices, stations, etc. PM2.5 particles are air pollutants with a diameter of 2.5 µm or less, containing soot, smoke, metals, nitrates, sulphates, dust, water and tyre rubber.
    When we breathe, PM2.5 can reach deep into our lungs, and some particles can even enter the bloodstream. Exposure to fine particles can affect the heart and lungs.

    Product specifications:

    - real-time measurement of PM2.5 concentration
    - Temperature and relative humidity measurement
    - Built-in LiPo battery
    - 3 hours to fully charge; can also be used whilst charging
    - PM2.5 display,
    - If the limit (μg/m³) is exceeded, the backlight turns red
    - In addition to exact values and guidance emojis

    Technical specifications:

    PM2.5 measurement (μg/m³):
    - range 0 to 100 ± (10 μg/dm³) +10 μg/dm³ +10 μg/dm³ 8 +10 μg/m³ 1 ± ambient temperature / ambient humidity: 40% to 75% RH
    - range 101 to 400 ± (10% + 30 dgts) / Ambient temperature: 18 to 28 °C / Ambient humidity: 40% to 75% RH
    - range 401 to 500 ± (10% + 30 digits) / 5 (10% to 28 °C) / ambient humidity: 40% to 75% RH

    Temperature measurement °C: -10 °C to +50 °C (0.1 °C/±1 °C)
    Humidity measurement: 0 to 99% RH (1% RH) / at ambient temperature 18 to 28 °C
    Backlit LCD display: 42 mm x 65 mm
    Weight: 230 g
    Dimensions: 75 mm x 55 mm x 130 mm

    Operating environment:
    - for indoor and outdoor environments or vehicles
    - Operating altitude: below 2,000 metres at 50 °C; Operating humidity: 0 to 99% RH

    Package contents
    - UNI-T A25D measuring instrument
    - charging cable
    - user manual
     

    />

    />

     


    />

    />

    parameters:

    1. Technical specifications:

    Operation / Range / Resolution / Accuracy / Note

    PM2.5 / 0 to 500μg/m³ / 1μg/m³ / ±(10μg/m³ + 10dgts) / Ambient temperature: 18 to 28°C / Ambient humidity
    40% to :> 40% RH Range 100μg/m³

    PM2.5 / 0 to 500μg/m³ / 1μg/m³ / ±(10% + 30dgts) / Ambient temperature: 18 to 28°C / Ambient humidity: 40% to 75%RH
    @ 101% to 40μg/m³
    0 to 500μg/m³ / 1μg/m³ / ±(10% + 50dgts) / Ambient temperature: 18 to 28°C / Ambient humidity: 40% to 75%RH
    @ 401 to 500 μg/m³ range

    Temperature / -10°C / -10°C / -10°C ±1°C

    Humidity / 0 to 99%RH / 1%RH / ±5%RH @30% to 80%RH / Temperature 18°C to 28°C

    Humidity / 0 to 99% RH / 1% RH / ±8% RH @ less than 30% RH / temperature less than 30% RH / more

    80%RH

    2. PM 2.5 Concentration assessment emoticons

    Concentration Emoji Backlight
    (μg/m³)
    0 to 35 White excellent
    36 to 75 White – Good
    76 to 115 Light pollution White
    116 to 150 Red Pollution level 151 to 250 Severe pollution Red
    251 to 500 Severe pollution red

    3. General features

    - powered by a built-in 1500mAh LiPo battery
    - 42mm x 65mm backlit LCD display, alarm - red backlight
    - Weight 230g
    - external dimensions 75mm x 55mm x 130mm
    - operating principle: PM2.5 -/>
    - altitude: less than or equal to 2000 metres
    - operating temperature: -10 to +50 °C; operating humidity: 0 to 99% RH
    - Storage temperature: -20 to 60 °C

    Package contents:

    - UNI-T A25D measuring instrument
    - µUSB-USB charging cable
    - User manual in Czech and English