| Battery Input Data |
| Battery Type |
Lead-acid or Lithium-ion |
| Battery Voltage Range (V) |
40–60 |
| Max. Charging Current (A) |
90 |
120 |
135 |
175 |
190 |
190 |
210 |
| Max. Discharge Current (A) |
90 |
120 |
135 |
175 |
190 |
190 |
210 |
| Charging Strategy for Li-ion Battery |
Self-adaptation to BMS |
| Number of battery inputs |
1 |
| PV String Input Data |
| Max. PV Input Power (W) |
7200 |
10,000 |
12,000 |
14000 |
15200 |
16,000 |
20,000 |
| Max PV Input Power (W) |
5760 |
8000 |
9600 |
11,200 |
12160 |
12,800 |
16000 |
| Max PV Input Voltage (V) |
500 |
| Start-up Voltage (V) |
125 |
| MPPT Voltage Range (V) |
150–425 |
| Rated PV Input Voltage (V) |
370 |
| Maximum operating PV input current (A) |
18+18 |
18+18 |
18+18 |
32+32 |
32+32 |
32+32 |
32+32 |
| Maximum Input Short-Circuit Current (A) |
27+27 |
27+27 |
27+27 |
48+48 |
48+48 |
48+48 |
48+48 |
| No. of MPP Trackers / Strings per MPPT |
2 / 1+1 |
2 / 1+1 |
2 / 1+1 |
2 / 2+2 |
2 / 2+2 |
2 / 2+2 |
2 / 2+2 |
| AC Input/Output Data |
| Rated AC Input/Output Active Power (W) |
3600 |
5000 |
6000 |
7000 |
7600 |
8000 |
10,000 |
| Max AC Apparent Power (VA) |
3960 |
5500 |
6600 |
7700 |
8360 |
8800 |
11000 |
| Rated AC Input/Output Current (A) |
16.4/15.7 |
22.7/21.7 |
27.3/26.1 |
31.9/30.5 |
34.5/33.0 |
36.4/34.8 |
45.5/43.5 |
| Max AC Input/Output Current (A) |
18/17.2 |
25/23.9 |
30/28.7 |
35.0/33.5 |
38/36.3 |
40/38.3 |
50/47.9 |
| Max Continuous AC Passthrough (A) |
35 / 40 / 50 |
| Peak Power (off-grid) |
2× rated power (10s) |
| Rated Input/Output Voltage Range (V) |
220/230V (0.85Un–1.1Un) |
| Grid Connection Type |
L + N + PE |
| Grid Frequency Range |
50Hz (45–55Hz) / 60Hz (55–65Hz) |
| Power Factor Adjustment Range |
0.8 leading – 0.8 lagging |
| THDi |
<3% |
| DC Injection Current |
<0.5% In |
| Efficiency |
| Max Efficiency |
97.60% |
| Euro Efficiency |
96.50% |
| MPPT Efficiency |
>99% |
| Equipment Protection |
| Integrated |
DC reverse polarity protection, AC output overcurrent protection, thermal protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Surge Protection Level |
TYPE II (DC), TYPE II (AC) |
| Interface |
| Communication |
RS485 / RS232 / CAN |
| Monitor Mode |
GPRS / WiFi / Bluetooth / 4G / LAN (optional) |
| General Data |
| Operating Temperature Range |
-40 to +60°C (>45°C derating) |
| Ambient Humidity |
0–100% |
| Altitude |
2500 m |
| Noise |
<30 dB(A) |
| IP Rating |
IP65 |
| Inverter Topology |
Non-isolated |
| Overvoltage Category |
OVC II (DC), OVC III (AC) |
| Cabinet Size (mm) |
330 × 580 × 232 |
| Weight (kg) |
24.9 |
| Warranty |
5 years / 10 years |
|
The warranty period depends on the final installation site of the inverter. Please refer to the warranty policy for details. |
| Grid Regulation |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE Directive R25, G98, G99, VDE-AR-N 4105 |
| Safety EMC Standards |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |