48V Inverter, Victron Energy MultiPlus-II 48/6k5/100-50

Description

⚠️ Stock availability and delivery time for products held in the supplier’s stock must be confirmed by phone.

Download the datasheet
Download the manual
Download the Declaration of Conformity

Victron Energy MultiPlus-II 48/6k5/100-50 combines a pure sine wave inverter and a battery charger rated at up to 100A in a single unit. It is designed for energy storage systems, backup power applications, and installations where grid or generator power must be intelligently supplemented with energy stored in batteries.

The model operates with 48V battery systems and delivers 6kW of continuous power at 25°C. For limited periods, it can support higher loads, reaching 8kW for up to one hour and a maximum output of 11kW for up to one minute, under the conditions specified by the manufacturer.

The MultiPlus-II can be used in grid-connected photovoltaic systems, off-grid installations, marine applications, mobile systems, and backup power solutions.

Important: The “6k5” designation is part of the model’s official name. The confirmed continuous output is 6kW at 25°C, while the 6.5kW rating is available only for a limited period.

Uninterruptible power for essential loads

The inverter’s main output operates as an uninterruptible AC power source. If the grid or generator is disconnected, the MultiPlus-II takes over the connected loads in less than 20ms.

This short transfer time allows computers, electronic equipment, and other critical loads to continue operating without noticeable interruption under normal conditions.

The product also features a second AC output. This output is powered only when an AC source is available at the MultiPlus-II input. It can be used for loads that should not discharge the battery, such as an electric water heater or other non-essential appliances.

PowerControl – protecting the grid or generator

The PowerControl function allows the maximum current available from the grid, generator, or shore power supply to be set.

The MultiPlus-II monitors the consumption of other equipment and uses only the remaining power to charge the batteries. This helps reduce the risk of overloading the AC power source.

PowerAssist – supplementing the available power

When the load temporarily exceeds the power available from the grid or generator, the PowerAssist function covers the difference using energy stored in the batteries.

Once consumption decreases, the available power is used to recharge the batteries. This function is useful in installations supplied by limited-capacity sources or in applications with temporary power-demand peaks.

Integrated 100A battery charger

The integrated charger delivers a maximum charging current of 100A at 25°C and 95A at 40°C.

The MultiPlus-II can be configured for use with several battery technologies, including lithium, lead-acid, and zinc-bromine batteries. The charging parameters must be adjusted according to the battery manufacturer’s specifications.

Integration into Victron ESS systems

The MultiPlus-II can serve as the main component of a Victron ESS – Energy Storage System.

It can be integrated with MPPT solar charge controllers, grid-connected photovoltaic inverters, energy meters, and monitoring and control devices from the Victron ecosystem.

Depending on the system configuration, an energy meter or external AC current sensor may be required to optimise self-consumption and control energy flow.

Parallel and three-phase operation

Up to six MultiPlus-II units can operate in parallel to achieve a higher power output.

Three identical units are required to create a three-phase system, with one unit assigned to each phase. The manufacturer also allows multiple three-phase sets to be connected in parallel, provided that Victron’s design and configuration requirements are followed.

All units used in a parallel or three-phase configuration must be the same model and must be configured accordingly.

Monitoring and control

The product is equipped with a VE.Bus communication port used for:

  • Parallel operation
  • Three-phase system configuration
  • System component integration
  • Configuration
  • Monitoring and control

Bluetooth monitoring requires an optional VE.Bus Smart dongle. Remote access and monitoring through the Victron VRM portal require a compatible GX device and an internet connection.

Local configuration may require the Victron MK3-USB interface, depending on the configuration method used.

Integrated protection features

Victron Energy MultiPlus-II includes protection against:

  • Output short circuits
  • Overloads
  • Excessively high battery voltage
  • Excessively low battery voltage
  • Excessive temperature
  • The presence of 230VAC at the inverter output
  • Excessively high input voltage ripple

The product has an IP21 protection rating and must be installed indoors, in an area protected from water, excessive humidity, and condensation, with adequate ventilation.

Main advantages

  • Combines an inverter and battery charger in a single unit
  • Keeps critical loads powered if the AC source fails
  • Delivers 6kW of continuous power at 25°C
  • Includes a battery charger rated at up to 100A
  • Intelligently manages limited AC power sources
  • Can temporarily supplement grid or generator power
  • Supports integration into a Victron ESS system
  • Can be used in parallel and three-phase configurations
  • Supports local and remote monitoring with the appropriate accessories
  • Suitable for residential, mobile, marine, and off-grid applications

Recommended applications

  • Victron ESS energy storage systems
  • Grid-connected photovoltaic systems
  • Off-grid photovoltaic systems
  • Backup power for critical loads
  • Generator-powered installations
  • Marine applications
  • Motorhomes and other mobile applications
  • Cabins and remote properties
  • Systems with limited AC power sources

Technical specifications

Specification Value
Manufacturer Victron Energy
Series MultiPlus-II
Model 48/6k5/100-50
Manufacturer product code PMP482605012
Product type Inverter/charger
Nominal battery system voltage 48V
DC input voltage range 38–60V
Output voltage 230VAC ±2%
Output frequency 50Hz ±0.1%
Configurable frequency 60Hz
Continuous output at 25°C 6kW
Continuous output at 40°C 5.7kW
Continuous output at 65°C 4.6kW
Cold-start limited output 6.5kW / 4 hours
Cold-start limited output 8kW / 1 hour
Maximum output 11kW / 1 minute
Maximum efficiency 96%
No-load power consumption 28W
No-load consumption in AES mode 18W
No-load consumption in Search mode 8W
Number of AC inputs 1
Number of AC outputs 2
Transfer switch 50A
Maximum AC input current 50A
AC input voltage range 187–265VAC
AC input frequency 45–65Hz
Maximum charging current at 25°C 100A
Maximum charging current at 40°C 95A
Absorption charging voltage 57.6V
Float charging voltage 55.2V
Storage mode voltage 52.8V
PowerControl function Yes
PowerAssist function Yes
UPS function Yes, transfer time under 20ms
Auxiliary output Yes, 32A
External AC current sensor Optional, maximum 100A
Programmable relay Yes
Remote on/off Yes
Communication VE.Bus and 2 general-purpose ports
Parallel operation Yes, up to 6 units
Three-phase configuration Yes, with 3 identical units
Operating temperature -40°C to +65°C
Cooling Fan-assisted
Maximum humidity 95%, non-condensing
Maximum altitude 4,000m
Power derating at altitude 1% for every 100m above 2,000m
Enclosure material Steel
Colour Blue, RAL 5012
Protection rating IP21
Battery connection M8 bolts
230VAC connection 13mm² / 6 AWG terminal block
Dimensions (H × W × D) 644 × 320 × 150mm
Weight 29kg

Compatibility and integration

The MultiPlus-II 48/6k5/100-50 can be used with lithium, lead-acid, zinc-bromine, and other battery technologies, provided that the charger is configured according to the battery manufacturer’s specified parameters.

Compatibility must be verified for the exact battery model, BMS, communication protocol, and firmware version. Mentioning a battery technology in the Victron datasheet does not automatically confirm direct communication with every battery in that category.

The product can be integrated with:

  • Victron MPPT solar charge controllers
  • Grid-connected photovoltaic inverters
  • Victron GX devices
  • The Victron VRM portal
  • Compatible energy meters
  • External current sensors
  • The MK3-USB interface
  • The VE.Bus Smart dongle
  • Victron ESS systems

The required accessories depend on the system configuration and should not be considered included unless this is explicitly confirmed.

Important warnings

  • “6k5” is the commercial designation of this model, not its continuous output power. The continuous output is 6kW at 25°C.
  • The 6.5kW, 8kW, and 11kW output levels are available only for limited periods and under the conditions specified by the manufacturer.
  • The product does not include an integrated MPPT solar charge controller. A separate solar charge controller or a compatible photovoltaic configuration is required to connect photovoltaic panels directly.
  • The IP21 protection rating indicates indoor use. The product must not be directly exposed to rain, water jets, or condensation.
  • Battery compatibility and communication with the BMS must be verified before purchase.
  • Charger parameters must be configured according to the battery manufacturer’s specifications.
  • Parallel or three-phase operation requires identical units and configuration in accordance with Victron documentation.
  • Bluetooth monitoring requires an optional VE.Bus Smart dongle.
  • Monitoring through the VRM portal requires a compatible GX device and an internet connection.
  • Local configuration may require an MK3-USB interface.
  • The external AC current sensor, temperature sensor, GX devices, MK3-USB interface, and other accessories must not be presented as included unless confirmed.
  • Installation, configuration, and commissioning must be carried out by qualified personnel.
  • Cables, protection devices, and battery capacity must be sized according to the system configuration and the manufacturer’s requirements.

48V Inverter, Victron Energy MultiPlus-II 48/6k5/100-50

Product form

⚠️ Stock availability and delivery time for products held in the supplier’s stock must be confirmed by phone. Download the... Read more

In stock  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€999,90 Incl. VAT

SKU: PMP482605012

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    ⚠️ Stock availability and delivery time for products held in the supplier’s stock must be confirmed by phone.

    Download the datasheet
    Download the manual
    Download the Declaration of Conformity

    Victron Energy MultiPlus-II 48/6k5/100-50 combines a pure sine wave inverter and a battery charger rated at up to 100A in a single unit. It is designed for energy storage systems, backup power applications, and installations where grid or generator power must be intelligently supplemented with energy stored in batteries.

    The model operates with 48V battery systems and delivers 6kW of continuous power at 25°C. For limited periods, it can support higher loads, reaching 8kW for up to one hour and a maximum output of 11kW for up to one minute, under the conditions specified by the manufacturer.

    The MultiPlus-II can be used in grid-connected photovoltaic systems, off-grid installations, marine applications, mobile systems, and backup power solutions.

    Important: The “6k5” designation is part of the model’s official name. The confirmed continuous output is 6kW at 25°C, while the 6.5kW rating is available only for a limited period.

    Uninterruptible power for essential loads

    The inverter’s main output operates as an uninterruptible AC power source. If the grid or generator is disconnected, the MultiPlus-II takes over the connected loads in less than 20ms.

    This short transfer time allows computers, electronic equipment, and other critical loads to continue operating without noticeable interruption under normal conditions.

    The product also features a second AC output. This output is powered only when an AC source is available at the MultiPlus-II input. It can be used for loads that should not discharge the battery, such as an electric water heater or other non-essential appliances.

    PowerControl – protecting the grid or generator

    The PowerControl function allows the maximum current available from the grid, generator, or shore power supply to be set.

    The MultiPlus-II monitors the consumption of other equipment and uses only the remaining power to charge the batteries. This helps reduce the risk of overloading the AC power source.

    PowerAssist – supplementing the available power

    When the load temporarily exceeds the power available from the grid or generator, the PowerAssist function covers the difference using energy stored in the batteries.

    Once consumption decreases, the available power is used to recharge the batteries. This function is useful in installations supplied by limited-capacity sources or in applications with temporary power-demand peaks.

    Integrated 100A battery charger

    The integrated charger delivers a maximum charging current of 100A at 25°C and 95A at 40°C.

    The MultiPlus-II can be configured for use with several battery technologies, including lithium, lead-acid, and zinc-bromine batteries. The charging parameters must be adjusted according to the battery manufacturer’s specifications.

    Integration into Victron ESS systems

    The MultiPlus-II can serve as the main component of a Victron ESS – Energy Storage System.

    It can be integrated with MPPT solar charge controllers, grid-connected photovoltaic inverters, energy meters, and monitoring and control devices from the Victron ecosystem.

    Depending on the system configuration, an energy meter or external AC current sensor may be required to optimise self-consumption and control energy flow.

    Parallel and three-phase operation

    Up to six MultiPlus-II units can operate in parallel to achieve a higher power output.

    Three identical units are required to create a three-phase system, with one unit assigned to each phase. The manufacturer also allows multiple three-phase sets to be connected in parallel, provided that Victron’s design and configuration requirements are followed.

    All units used in a parallel or three-phase configuration must be the same model and must be configured accordingly.

    Monitoring and control

    The product is equipped with a VE.Bus communication port used for:

    • Parallel operation
    • Three-phase system configuration
    • System component integration
    • Configuration
    • Monitoring and control

    Bluetooth monitoring requires an optional VE.Bus Smart dongle. Remote access and monitoring through the Victron VRM portal require a compatible GX device and an internet connection.

    Local configuration may require the Victron MK3-USB interface, depending on the configuration method used.

    Integrated protection features

    Victron Energy MultiPlus-II includes protection against:

    • Output short circuits
    • Overloads
    • Excessively high battery voltage
    • Excessively low battery voltage
    • Excessive temperature
    • The presence of 230VAC at the inverter output
    • Excessively high input voltage ripple

    The product has an IP21 protection rating and must be installed indoors, in an area protected from water, excessive humidity, and condensation, with adequate ventilation.

    Main advantages

    • Combines an inverter and battery charger in a single unit
    • Keeps critical loads powered if the AC source fails
    • Delivers 6kW of continuous power at 25°C
    • Includes a battery charger rated at up to 100A
    • Intelligently manages limited AC power sources
    • Can temporarily supplement grid or generator power
    • Supports integration into a Victron ESS system
    • Can be used in parallel and three-phase configurations
    • Supports local and remote monitoring with the appropriate accessories
    • Suitable for residential, mobile, marine, and off-grid applications

    Recommended applications

    • Victron ESS energy storage systems
    • Grid-connected photovoltaic systems
    • Off-grid photovoltaic systems
    • Backup power for critical loads
    • Generator-powered installations
    • Marine applications
    • Motorhomes and other mobile applications
    • Cabins and remote properties
    • Systems with limited AC power sources

    Technical specifications

    Specification Value
    Manufacturer Victron Energy
    Series MultiPlus-II
    Model 48/6k5/100-50
    Manufacturer product code PMP482605012
    Product type Inverter/charger
    Nominal battery system voltage 48V
    DC input voltage range 38–60V
    Output voltage 230VAC ±2%
    Output frequency 50Hz ±0.1%
    Configurable frequency 60Hz
    Continuous output at 25°C 6kW
    Continuous output at 40°C 5.7kW
    Continuous output at 65°C 4.6kW
    Cold-start limited output 6.5kW / 4 hours
    Cold-start limited output 8kW / 1 hour
    Maximum output 11kW / 1 minute
    Maximum efficiency 96%
    No-load power consumption 28W
    No-load consumption in AES mode 18W
    No-load consumption in Search mode 8W
    Number of AC inputs 1
    Number of AC outputs 2
    Transfer switch 50A
    Maximum AC input current 50A
    AC input voltage range 187–265VAC
    AC input frequency 45–65Hz
    Maximum charging current at 25°C 100A
    Maximum charging current at 40°C 95A
    Absorption charging voltage 57.6V
    Float charging voltage 55.2V
    Storage mode voltage 52.8V
    PowerControl function Yes
    PowerAssist function Yes
    UPS function Yes, transfer time under 20ms
    Auxiliary output Yes, 32A
    External AC current sensor Optional, maximum 100A
    Programmable relay Yes
    Remote on/off Yes
    Communication VE.Bus and 2 general-purpose ports
    Parallel operation Yes, up to 6 units
    Three-phase configuration Yes, with 3 identical units
    Operating temperature -40°C to +65°C
    Cooling Fan-assisted
    Maximum humidity 95%, non-condensing
    Maximum altitude 4,000m
    Power derating at altitude 1% for every 100m above 2,000m
    Enclosure material Steel
    Colour Blue, RAL 5012
    Protection rating IP21
    Battery connection M8 bolts
    230VAC connection 13mm² / 6 AWG terminal block
    Dimensions (H × W × D) 644 × 320 × 150mm
    Weight 29kg

    Compatibility and integration

    The MultiPlus-II 48/6k5/100-50 can be used with lithium, lead-acid, zinc-bromine, and other battery technologies, provided that the charger is configured according to the battery manufacturer’s specified parameters.

    Compatibility must be verified for the exact battery model, BMS, communication protocol, and firmware version. Mentioning a battery technology in the Victron datasheet does not automatically confirm direct communication with every battery in that category.

    The product can be integrated with:

    • Victron MPPT solar charge controllers
    • Grid-connected photovoltaic inverters
    • Victron GX devices
    • The Victron VRM portal
    • Compatible energy meters
    • External current sensors
    • The MK3-USB interface
    • The VE.Bus Smart dongle
    • Victron ESS systems

    The required accessories depend on the system configuration and should not be considered included unless this is explicitly confirmed.

    Important warnings

    • “6k5” is the commercial designation of this model, not its continuous output power. The continuous output is 6kW at 25°C.
    • The 6.5kW, 8kW, and 11kW output levels are available only for limited periods and under the conditions specified by the manufacturer.
    • The product does not include an integrated MPPT solar charge controller. A separate solar charge controller or a compatible photovoltaic configuration is required to connect photovoltaic panels directly.
    • The IP21 protection rating indicates indoor use. The product must not be directly exposed to rain, water jets, or condensation.
    • Battery compatibility and communication with the BMS must be verified before purchase.
    • Charger parameters must be configured according to the battery manufacturer’s specifications.
    • Parallel or three-phase operation requires identical units and configuration in accordance with Victron documentation.
    • Bluetooth monitoring requires an optional VE.Bus Smart dongle.
    • Monitoring through the VRM portal requires a compatible GX device and an internet connection.
    • Local configuration may require an MK3-USB interface.
    • The external AC current sensor, temperature sensor, GX devices, MK3-USB interface, and other accessories must not be presented as included unless confirmed.
    • Installation, configuration, and commissioning must be carried out by qualified personnel.
    • Cables, protection devices, and battery capacity must be sized according to the system configuration and the manufacturer’s requirements.

    Recently viewed products

      © 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account