UNI-T UTD1062C Oscilloscope

Description

UNI-T UTD1062C Oscilloscope
The UTD1062C combines a two-channel portable oscilloscope and a multimeter in a single unit. It offers excellent specifications and a range of advanced functions, as well as ease of use, making it suitable for fieldwork. The oscilloscope’s bandwidth is up to 60 MHz at a sampling rate of 250 MSa/s. Its powerful triggering and analysis functions facilitate the acquisition and analysis of waveforms, capable of measuring 27 signal parameters fully automatically. A multimeter allows you to measure DC and AC voltages and currents, resistance and capacitance.
The device features a built-in 5.7-inch colour LCD display with a resolution of 320 x 240 pixels. The display shows waveforms in monochrome mode, making it easy to read even in bright light. In multimeter mode, the maximum value displayed is ±5999.
The device is powered by a built-in Li-ion battery or a 9V/4A AC/DC adapter.
As the device’s design is based on traditional instrument controls, users can operate these devices without needing to spend a significant amount of time learning and familiarising themselves with the input voltage range. 150V in CAT II (1:1 probe divider) and an input voltage of 300V in CAT II (1:10 probe divider). 250MS/s
- Max. memory depth: 7.5 kpts
- A/D converter resolution: 8 bits
- Time base range: 5 ns/div to 50 s/div
- Input coupling: (1 MΩ ± 2%) // (21 pF ± 3 pF)
- vertical axis: 5 mV/div/div – 5 mV/div)
- Trigger: Edge, pulse, video
- mathematical operations with waveforms: A + B, A - B, A × B, A : B
- automatic measurement: peak-to-peak, amplitude, maximum, minimum, high, low, average, root mean square, overshoot, frequency, overshoot, pulse, overshoot, frequency, overshoot, overshoot, overshoot, overshoot, overshoot, overshoot, overshoot, overshoot, positive duty cycle, negative duty cycle, rise time, fall time
- FFT: Hanning, Hamming, Blackman-Harris, rectangular
- internal memory storage: 10 groups of curves, 10 setting modes
- USB saving: 10 groups of curves, 10 groups of measurement interfaces

Voltage: 600mV / 6V / 60V / 600V / 1000V; accuracy ±(1%+5)
- AC voltage measurement ranges (45Hz to 400Hz): 600mV / 6V / 60V / 600V / 700V; for accuracy f < 200Hz ±(1.2%+5); for accuracy f ≥ 200Hz ±(1.5%+5)
- DC current measurement ranges: 6mA / 60mA / 600mA; accuracy ±(1.2%+5); for 6A accuracy ±(1.5%+5)
- AC current measurement ranges (45 Hz to 400 Hz): 6 mA / 60 mA / 600 mA; accuracy ±(2%+5); for 6 A accuracy ±(2.5%+5)
- resistance measurement ranges: 6kΩ / 60kΩ / 600kΩ; accuracy ±(1.2%+5); accuracy 600Ω / 6MΩ / 60MΩ ±(1.5%+5);
- capacitance measurement ranges: 6nF / 6mF; accuracy ±(5%+10); accuracy 60nF / 600nF / 6µF / 60µF / 600µF ±(4%+5);
- Diode and continuity testing: yes
- range switching mode: automatic / manual
- display and recording of trend curves for changes in voltage, current and parameters
>
Technical/resistance:

- power supply: 100V–240V AC, 45 to 440Hz, CAT II, power consumption < 20VA
- standard interface: 1 x USB-Host
- battery: Li-ion 7.4V/4400mA
- Battery life:
- 3 hours: 80 inches, display: 80 inches - 3 hours pixels
- Calibration: recommended once a year
- IP rating: IP2X
- Operating ambient temperature: 0°C to +40°C
- Storage temperature: -20°C to +60°C
- Operating ambient humidity: <35℃: ≤90%RH, ≤90%RH, ≤90%RH: 35℃-40℃>-40°C altitude: max. 3000m above sea level
- Non-operational (storage) altitude: 15,000 m above sea level
- net weight: 1.8 kg
- gross weight: 4.5 kg
- dimensions: 268 x 168 x 60 mm

Package contents:

UTD1062C: 1 pc
- probe with 1.2 m cable and 1x, 10x switchable divider (UT-H04): 2 pcs
- current (4 mA to 600 mA) / voltage converter module (UT-M03): 1 pc
- Current (4A to 6A voltage converter) / DC-M04 adapter: (UT-M04 module) 100 to 240 V AC rms, 45 to 440 Hz, CAT II: 1 pc
- USB cable: 1 pc
- User manual: 1 pc

Packaging for bulk customers:

- Standard quantity per box: 4 pcs x box dimensions: 400 x 200 x 200 mm
- Gross weight of box: approx. 16.7 kg

MANUFACTURER:
UNI-TREND

Software update:
https://instruments.uni-trend.com/EU-EN/handheldoscilloscopes/utd1000c.html


UNI-T UTD1062C Oscilloscope

Product form

UNI-T UTD1062C Oscilloscope The UTD1062C combines a two-channel portable oscilloscope and a multimeter in a single unit. It offers excellent... Read more

10 - 20 days  Contact us at contact@solartech.eu for more info regarding the inventory of this product.

€561,36 Incl. VAT

SKU: 07730020

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>
    • 3 - 10 Days Delivery 🚚
    • Sales & Technical Support ⚙️

    Description

    UNI-T UTD1062C Oscilloscope
    The UTD1062C combines a two-channel portable oscilloscope and a multimeter in a single unit. It offers excellent specifications and a range of advanced functions, as well as ease of use, making it suitable for fieldwork. The oscilloscope’s bandwidth is up to 60 MHz at a sampling rate of 250 MSa/s. Its powerful triggering and analysis functions facilitate the acquisition and analysis of waveforms, capable of measuring 27 signal parameters fully automatically. A multimeter allows you to measure DC and AC voltages and currents, resistance and capacitance.
    The device features a built-in 5.7-inch colour LCD display with a resolution of 320 x 240 pixels. The display shows waveforms in monochrome mode, making it easy to read even in bright light. In multimeter mode, the maximum value displayed is ±5999.
    The device is powered by a built-in Li-ion battery or a 9V/4A AC/DC adapter.
    As the device’s design is based on traditional instrument controls, users can operate these devices without needing to spend a significant amount of time learning and familiarising themselves with the input voltage range. 150V in CAT II (1:1 probe divider) and an input voltage of 300V in CAT II (1:10 probe divider). 250MS/s
    - Max. memory depth: 7.5 kpts
    - A/D converter resolution: 8 bits
    - Time base range: 5 ns/div to 50 s/div
    - Input coupling: (1 MΩ ± 2%) // (21 pF ± 3 pF)
    - vertical axis: 5 mV/div/div – 5 mV/div)
    - Trigger: Edge, pulse, video
    - mathematical operations with waveforms: A + B, A - B, A × B, A : B
    - automatic measurement: peak-to-peak, amplitude, maximum, minimum, high, low, average, root mean square, overshoot, frequency, overshoot, pulse, overshoot, frequency, overshoot, overshoot, overshoot, overshoot, overshoot, overshoot, overshoot, overshoot, positive duty cycle, negative duty cycle, rise time, fall time
    - FFT: Hanning, Hamming, Blackman-Harris, rectangular
    - internal memory storage: 10 groups of curves, 10 setting modes
    - USB saving: 10 groups of curves, 10 groups of measurement interfaces

    Voltage: 600mV / 6V / 60V / 600V / 1000V; accuracy ±(1%+5)
    - AC voltage measurement ranges (45Hz to 400Hz): 600mV / 6V / 60V / 600V / 700V; for accuracy f < 200Hz ±(1.2%+5); for accuracy f ≥ 200Hz ±(1.5%+5)
    - DC current measurement ranges: 6mA / 60mA / 600mA; accuracy ±(1.2%+5); for 6A accuracy ±(1.5%+5)
    - AC current measurement ranges (45 Hz to 400 Hz): 6 mA / 60 mA / 600 mA; accuracy ±(2%+5); for 6 A accuracy ±(2.5%+5)
    - resistance measurement ranges: 6kΩ / 60kΩ / 600kΩ; accuracy ±(1.2%+5); accuracy 600Ω / 6MΩ / 60MΩ ±(1.5%+5);
    - capacitance measurement ranges: 6nF / 6mF; accuracy ±(5%+10); accuracy 60nF / 600nF / 6µF / 60µF / 600µF ±(4%+5);
    - Diode and continuity testing: yes
    - range switching mode: automatic / manual
    - display and recording of trend curves for changes in voltage, current and parameters
    >
    Technical/resistance:

    - power supply: 100V–240V AC, 45 to 440Hz, CAT II, power consumption < 20VA
    - standard interface: 1 x USB-Host
    - battery: Li-ion 7.4V/4400mA
    - Battery life:
    - 3 hours: 80 inches, display: 80 inches - 3 hours pixels
    - Calibration: recommended once a year
    - IP rating: IP2X
    - Operating ambient temperature: 0°C to +40°C
    - Storage temperature: -20°C to +60°C
    - Operating ambient humidity: <35℃: ≤90%RH, ≤90%RH, ≤90%RH: 35℃-40℃>-40°C altitude: max. 3000m above sea level
    - Non-operational (storage) altitude: 15,000 m above sea level
    - net weight: 1.8 kg
    - gross weight: 4.5 kg
    - dimensions: 268 x 168 x 60 mm

    Package contents:

    UTD1062C: 1 pc
    - probe with 1.2 m cable and 1x, 10x switchable divider (UT-H04): 2 pcs
    - current (4 mA to 600 mA) / voltage converter module (UT-M03): 1 pc
    - Current (4A to 6A voltage converter) / DC-M04 adapter: (UT-M04 module) 100 to 240 V AC rms, 45 to 440 Hz, CAT II: 1 pc
    - USB cable: 1 pc
    - User manual: 1 pc

    Packaging for bulk customers:

    - Standard quantity per box: 4 pcs x box dimensions: 400 x 200 x 200 mm
    - Gross weight of box: approx. 16.7 kg

    MANUFACTURER:
    UNI-TREND

    Software update:
    https://instruments.uni-trend.com/EU-EN/handheldoscilloscopes/utd1000c.html


    Recently viewed products

      © 2026 SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account