Description
UNI-T UT202F Clamp Meter
This product comes with a 3-year warranty. The UT202F digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 600A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V/50/60Hz and 230V/50/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
- measurement of voltage, current and high-voltage frequency up to 600 V
- non-contact electric field detection (NCV)
- Frequency measurement from 10 MHz to 600 V
60mF
- Measurement of the (relative) ratio of voltages and capacitances
- multi-segment display and audible/visual alarm
- protection against voltages exceeding 600V in ranges
- automatic range switching
- accuracy of current and voltage measurements guaranteed within 1% of the technical
parameters:
1. AC current measurement (ranges / resolution / accuracy):
6,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% + 10)
60.00A / 0.010A / 50Hz ~ 100Hz ± 10.0%
(2.0) 0.100A / 50Hz ~ 100Hz ± (2.0% + 10)
- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz
- overload protection at 620A.>
AC voltage measurement (range / resolution / accuracy):
6,000 V / 0.001 V / 10 Hz ~ 10 kHz ± (1.0% + 5)
60.00 V / 0.010 V / 10 Hz ~ 10 kHz ± 0.8% / 50.8% / 0.100 V / 10 Hz ~ 10 kHz ± (0.8% + 5)
- frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz overload protection at the input
-0.01kHz overload
-0. approx. 10 MΩ
3. DC voltage measurement (range / resolution / accuracy):
600.0 mV / 0.100 mV / ± (0.7% + 3)
6,000 V / 0.001 V / ± (0.5% + 2)
60.00 V / 0.010 V / ±0.7% 3)
600.0 V / 0.100 V / ± (0.7% + 3)
- input impedance approx. 10 MΩ
- overload protection at 600 Vrms
4. Resistance measurement (range / resolution / accuracy):
600.0Ω / 0.1Ω / ± (1.0% + 2)
6,000 kΩ / 0.001 kΩ / ± (0.8% + 2)
60.00 kΩ / 0.01 kΩ / ± (0.01 kΩ / ± (0.01 kΩ) 2)
600.0 kΩ / 0.1 kΩ / ± (0.8% + 2)
6,000 MΩ / 0.001 MΩ / ± (2.0% + 5)
60.00 MΩ / 0.01 MΩ / ± (2.0% + 5) overload protection at 6.0% + 5)
-50 Vrms
5. Capacitance measurement (ranges / resolution / accuracy):
6,000 nF / 0.001 nF / ± (4.0% + 10)
60.00 nF / 0.01 nF / ± (4.0% + 10)
600.0 nF / 0.00% + 1.10)
6,000 μF / 0.001 μF / ± (4.0% + 5)
60.00 μF / 0.01 μF / ± (4.0% + 5)
600.0μF / 0.1μF / ± (4.0% + 5)
600.0μF / 0.1μF / ± (4.0% + 5). ± 10.0%
60.00 mF / 0.01 mF / ± 10.0%
- overload protection at 600 Vrms
6. Frequency and load measurement (ranges / resolution / accuracy):
frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ± (0.1% + 4)
Duty cycle: 0.1 to 99.9% / 0.1% / ± 5.0% / ± 5.0% Measurement sensitivity:
≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS
> 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS
>1 V RMS input
> 1 V RMS: amplitude ≤ 30 V RMS
- Note 2) Duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p
Frequency ≤ 1kHz Duty cycle: 10.0% ~ 95% Duty cycle: 30.0% ~ 70.0%
- Overload protection at 600 V rms
7. Circuit continuity check:
- if the measured resistance is less than 10Ω, the continuity circuit signal triggers a buzzer
- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer
- open-circuit voltage approximately 2.0V
- measurement in the overload protection range
60-0Ω during overload
Vrms
8. Diode measurement:
- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open-circuit voltage of approximately 3.9V
- measurement range of 6.000V
Parameters:
- measurement of maximum and minimum values: yes
- Relative mode (ratio) measurement for voltage and capacitance: yes
- HOLD: yes
- low battery indicator: yes
- auto-off: yes
- 1.5 V battery power supply (backlit display size: 3 x 3): 25 mm
- Product dimensions: 215 mm x 63 mm x 36 mm
- net product weight: 248 g
- Product colour: red and grey
Package contents:
- UT201R clamp multimeter: 1 pc. test leads
/>- 1 pc. (R03): 2 pcs
- user manual: 1 pc
Wholesale packaging:
- standard quantity per box: 40 pcs
- standard box dimensions: 485 mm x 295 mm x 385 mm
- standard gross weight per box: 16/F: 7 kg
https://www.uni-trend