{"product_id":"deye-14kw-three-phase-hybrid-inverter-sun-14k-sg05lp3-eu-sm2","title":"DEYE 14kW Three-Phase Hybrid Inverter SUN-14K-SG05LP3-EU-SM2","description":"\u003cp data-start=\"65\" data-end=\"150\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/26\/BDatasheetSUN-14-20K-SG05LP3-EU-SM220260424en.pdf\"\u003eDownload the datasheet\u003c\/a\u003e\u003cbr data-start=\"87\" data-end=\"90\"\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/26\/BDatasheetSUN-14-20K-SG05LP3-EU-SM220260424en.pdf\"\u003eDownload the manual\u003c\/a\u003e\u003cbr data-start=\"109\" data-end=\"112\"\u003e\u003ca href=\"https:\/\/hqcdn.hqsmartcloud.com\/deyeinverter\/2025\/08\/02\/certificate_europe_en50549-10.pdf\"\u003eDownload the Declaration of Conformity\u003c\/a\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"152\" data-end=\"510\"\u003eThe DEYE SUN-14K-SG05LP3-EU-SM2 is a 14kW three-phase hybrid inverter designed for photovoltaic systems with low-voltage battery storage. Its 40–60V battery architecture and two dedicated battery inputs allow for a flexible system configuration, suitable for homes with high energy consumption, guesthouses, offices, workshops, and small commercial premises.\u003c\/p\u003e\n\u003cp data-start=\"512\" data-end=\"902\"\u003eThe inverter manages the energy generated by the solar panels, battery, grid, and loads within a single unit. It can be integrated through AC coupling into an existing photovoltaic system and supports the storage of energy supplied by a diesel generator. Six programmable time periods for battery charging and discharging help adapt the system to the consumption profile and energy tariffs.\u003c\/p\u003e\n\u003cp data-start=\"904\" data-end=\"1265\"\u003eThe model supports up to 22.4kW of maximum PV input power and uses two MPPT trackers, each supporting two strings. In three-phase operation, the output can be 100% unbalanced, with each phase supplying up to 50% of the inverter’s rated power. For loads with high starting currents, the off-grid output can temporarily reach twice the rated power for 10 seconds.\u003c\/p\u003e\n\u003ch2 data-section-id=\"hxesp5\" data-start=\"1267\" data-end=\"1283\"\u003eMain features\u003c\/h2\u003e\n\u003cul data-start=\"1285\" data-end=\"1927\"\u003e\n\u003cli data-section-id=\"wdznh0\" data-start=\"1285\" data-end=\"1319\"\u003e14kW three-phase hybrid inverter\u003c\/li\u003e\n\u003cli data-section-id=\"r44dr2\" data-start=\"1320\" data-end=\"1379\"\u003eCompatible with 40–60V lead-acid or lithium-ion batteries\u003c\/li\u003e\n\u003cli data-section-id=\"1lefh70\" data-start=\"1380\" data-end=\"1400\"\u003eTwo battery inputs\u003c\/li\u003e\n\u003cli data-section-id=\"waun40\" data-start=\"1401\" data-end=\"1451\"\u003eMaximum charging and discharging current of 260A\u003c\/li\u003e\n\u003cli data-section-id=\"9vsifv\" data-start=\"1452\" data-end=\"1503\"\u003eTwo MPPT trackers with a 2+2 string configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1choxuu\" data-start=\"1504\" data-end=\"1564\"\u003eSix programmable battery charging\/discharging time periods\u003c\/li\u003e\n\u003cli data-section-id=\"1rsizmk\" data-start=\"1565\" data-end=\"1633\"\u003eAC coupling function for upgrading an existing photovoltaic system\u003c\/li\u003e\n\u003cli data-section-id=\"q3vhdn\" data-start=\"1634\" data-end=\"1725\"\u003eSupports the parallel connection of up to 10 inverters for on-grid and off-grid operation\u003c\/li\u003e\n\u003cli data-section-id=\"4xry9o\" data-start=\"1726\" data-end=\"1777\"\u003eSupports multiple batteries connected in parallel\u003c\/li\u003e\n\u003cli data-section-id=\"1u0higp\" data-start=\"1778\" data-end=\"1827\"\u003eSupports energy storage from a diesel generator\u003c\/li\u003e\n\u003cli data-section-id=\"k4cxhy\" data-start=\"1828\" data-end=\"1864\"\u003e100% unbalanced three-phase output\u003c\/li\u003e\n\u003cli data-section-id=\"9brdjf\" data-start=\"1865\" data-end=\"1902\"\u003eWi-Fi, RS485, and CAN communication\u003c\/li\u003e\n\u003cli data-section-id=\"17ke66u\" data-start=\"1903\" data-end=\"1927\"\u003eIP65 protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1344z7h\" data-start=\"1929\" data-end=\"1942\"\u003eAdvantages\u003c\/h2\u003e\n\u003cp data-start=\"1944\" data-end=\"2100\"\u003e\u003cstrong data-start=\"1944\" data-end=\"1976\"\u003eGreater storage flexibility:\u003c\/strong\u003e The low-voltage battery system and two battery inputs make it easier to configure a storage capacity suited to the project.\u003c\/p\u003e\n\u003cp data-start=\"2102\" data-end=\"2288\"\u003e\u003cstrong data-start=\"2102\" data-end=\"2135\"\u003eImproved use of solar energy:\u003c\/strong\u003e The oversized PV input capacity compared with the AC output extends the daily production window, provided that the technical string limits are observed.\u003c\/p\u003e\n\u003cp data-start=\"2290\" data-end=\"2465\"\u003e\u003cstrong data-start=\"2290\" data-end=\"2350\"\u003eReliable power delivery under real operating conditions:\u003c\/strong\u003e The unbalanced output function provides improved management of loads distributed unevenly across the three phases.\u003c\/p\u003e\n\u003cp data-start=\"2467\" data-end=\"2609\"\u003e\u003cstrong data-start=\"2467\" data-end=\"2507\"\u003eIntegration into an existing system:\u003c\/strong\u003e AC coupling allows storage and hybrid functions to be added to an existing photovoltaic installation.\u003c\/p\u003e\n\u003cp data-start=\"2611\" data-end=\"2733\"\u003e\u003cstrong data-start=\"2611\" data-end=\"2659\"\u003eControl adapted to the consumption schedule:\u003c\/strong\u003e Six time periods allow battery charging and discharging to be programmed.\u003c\/p\u003e\n\u003cp data-start=\"2735\" data-end=\"2901\"\u003e\u003cstrong data-start=\"2735\" data-end=\"2756\"\u003eFuture expansion:\u003c\/strong\u003e Up to 10 units can operate in parallel, provided that the system is designed and configured in accordance with the manufacturer’s documentation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"w3ml15\" data-start=\"2903\" data-end=\"2930\"\u003eRecommended applications\u003c\/h2\u003e\n\u003cul data-start=\"2932\" data-end=\"3269\"\u003e\n\u003cli data-section-id=\"1svvnir\" data-start=\"2932\" data-end=\"2980\"\u003eThree-phase homes with high energy consumption\u003c\/li\u003e\n\u003cli data-section-id=\"j6rym\" data-start=\"2981\" data-end=\"3026\"\u003eGuesthouses and large residential buildings\u003c\/li\u003e\n\u003cli data-section-id=\"1gtwptu\" data-start=\"3027\" data-end=\"3072\"\u003eOffices, practices, and commercial premises\u003c\/li\u003e\n\u003cli data-section-id=\"23h1bz\" data-start=\"3073\" data-end=\"3118\"\u003eWorkshops and small commercial applications\u003c\/li\u003e\n\u003cli data-section-id=\"18w4e60\" data-start=\"3119\" data-end=\"3197\"\u003eNew photovoltaic systems or upgrades to existing systems through AC coupling\u003c\/li\u003e\n\u003cli data-section-id=\"1txi410\" data-start=\"3198\" data-end=\"3269\"\u003eSystems with battery storage and an additional generator power source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"19xnbiw\" data-start=\"3271\" data-end=\"3298\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3300\" data-end=\"5201\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3300\" data-end=\"3325\"\u003e\n\u003ctr data-start=\"3300\" data-end=\"3325\"\u003e\n\u003cth data-start=\"3300\" data-end=\"3316\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3316\" data-end=\"3325\" data-col-size=\"md\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3336\" data-end=\"5201\"\u003e\n\u003ctr data-start=\"3336\" data-end=\"3370\"\u003e\n\u003ctd data-start=\"3336\" data-end=\"3344\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3344\" data-end=\"3370\"\u003eSUN-14K-SG05LP3-EU-SM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3371\" data-end=\"3409\"\u003e\n\u003ctd data-start=\"3371\" data-end=\"3378\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3378\" data-end=\"3409\"\u003eThree-phase hybrid inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3410\" data-end=\"3453\"\u003e\n\u003ctd data-start=\"3410\" data-end=\"3425\" data-col-size=\"sm\"\u003eBattery type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3425\" data-end=\"3453\"\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3454\" data-end=\"3488\"\u003e\n\u003ctd data-start=\"3454\" data-end=\"3478\" data-col-size=\"sm\"\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3478\" data-end=\"3488\"\u003e40–60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3489\" data-end=\"3521\"\u003e\n\u003ctd data-start=\"3489\" data-end=\"3516\" data-col-size=\"sm\"\u003eNumber of battery inputs\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3516\" data-end=\"3521\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3522\" data-end=\"3569\"\u003e\n\u003ctd data-start=\"3522\" data-end=\"3561\" data-col-size=\"sm\"\u003eMaximum charging\/discharging current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3561\" data-end=\"3569\"\u003e260A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3570\" data-end=\"3637\"\u003e\n\u003ctd data-start=\"3570\" data-end=\"3602\" data-col-size=\"sm\"\u003eLithium-ion charging strategy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3602\" data-end=\"3637\"\u003eAutomatic adaptation to the BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3638\" data-end=\"3675\"\u003e\n\u003ctd data-start=\"3638\" data-end=\"3664\" data-col-size=\"sm\"\u003eMaximum PV access power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3664\" data-end=\"3675\"\u003e28,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3676\" data-end=\"3712\"\u003e\n\u003ctd data-start=\"3676\" data-end=\"3701\" data-col-size=\"sm\"\u003eMaximum PV input power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3701\" data-end=\"3712\"\u003e22,400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3713\" data-end=\"3748\"\u003e\n\u003ctd data-start=\"3713\" data-end=\"3740\" data-col-size=\"sm\"\u003eMaximum PV input voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3740\" data-end=\"3748\"\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3749\" data-end=\"3776\"\u003e\n\u003ctd data-start=\"3749\" data-end=\"3768\" data-col-size=\"sm\"\u003eStart-up voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3768\" data-end=\"3776\"\u003e160V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3777\" data-end=\"3810\"\u003e\n\u003ctd data-start=\"3777\" data-end=\"3798\" data-col-size=\"sm\"\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3798\" data-end=\"3810\"\u003e160–650V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3811\" data-end=\"3844\"\u003e\n\u003ctd data-start=\"3811\" data-end=\"3836\" data-col-size=\"sm\"\u003eRated PV input voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3836\" data-end=\"3844\"\u003e550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3845\" data-end=\"3892\"\u003e\n\u003ctd data-start=\"3845\" data-end=\"3882\" data-col-size=\"sm\"\u003eMaximum PV operating input current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3882\" data-end=\"3892\"\u003e36+36A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3893\" data-end=\"3938\"\u003e\n\u003ctd data-start=\"3893\" data-end=\"3928\" data-col-size=\"sm\"\u003eMaximum PV short-circuit current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3928\" data-end=\"3938\"\u003e54+54A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3939\" data-end=\"3985\"\u003e\n\u003ctd data-start=\"3939\" data-end=\"3974\" data-col-size=\"sm\"\u003eMPPT trackers \/ strings per MPPT\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3974\" data-end=\"3985\"\u003e2 \/ 2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3986\" data-end=\"4021\"\u003e\n\u003ctd data-start=\"3986\" data-end=\"4010\" data-col-size=\"sm\"\u003eRated AC active power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4010\" data-end=\"4021\"\u003e14,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4022\" data-end=\"4062\"\u003e\n\u003ctd data-start=\"4022\" data-end=\"4050\" data-col-size=\"sm\"\u003eMaximum AC apparent power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4050\" data-end=\"4062\"\u003e15,400VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4063\" data-end=\"4109\"\u003e\n\u003ctd data-start=\"4063\" data-end=\"4095\" data-col-size=\"sm\"\u003eRated AC input\/output current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4095\" data-end=\"4109\"\u003e21.3\/20.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4110\" data-end=\"4158\"\u003e\n\u003ctd data-start=\"4110\" data-end=\"4144\" data-col-size=\"sm\"\u003eMaximum AC input\/output current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4144\" data-end=\"4158\"\u003e23.4\/22.4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4159\" data-end=\"4205\"\u003e\n\u003ctd data-start=\"4159\" data-end=\"4198\" data-col-size=\"sm\"\u003eMaximum continuous AC bypass current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4198\" data-end=\"4205\"\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4206\" data-end=\"4262\"\u003e\n\u003ctd data-start=\"4206\" data-end=\"4228\" data-col-size=\"sm\"\u003eOff-grid peak power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4228\" data-end=\"4262\"\u003e2 × rated power for 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4263\" data-end=\"4337\"\u003e\n\u003ctd data-start=\"4263\" data-end=\"4292\" data-col-size=\"sm\"\u003eRated input\/output voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4292\" data-end=\"4337\"\u003e220\/380V, 230\/400V; 0.85Un–1.1Un; 3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4338\" data-end=\"4395\"\u003e\n\u003ctd data-start=\"4338\" data-end=\"4361\" data-col-size=\"sm\"\u003eGrid frequency\/range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4361\" data-end=\"4395\"\u003e50Hz \/ 45–55Hz; 60Hz \/ 55–65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4396\" data-end=\"4458\"\u003e\n\u003ctd data-start=\"4396\" data-end=\"4428\" data-col-size=\"sm\"\u003ePower factor adjustment range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4428\" data-end=\"4458\"\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4459\" data-end=\"4488\"\u003e\n\u003ctd data-start=\"4459\" data-end=\"4466\" data-col-size=\"sm\"\u003eTHDi\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4466\" data-end=\"4488\"\u003e\u0026lt;3% of rated power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4489\" data-end=\"4524\"\u003e\n\u003ctd data-start=\"4489\" data-end=\"4512\" data-col-size=\"sm\"\u003eDC injection current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4512\" data-end=\"4524\"\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4525\" data-end=\"4555\"\u003e\n\u003ctd data-start=\"4525\" data-end=\"4546\" data-col-size=\"sm\"\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4546\" data-end=\"4555\"\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4556\" data-end=\"4587\"\u003e\n\u003ctd data-start=\"4556\" data-end=\"4578\" data-col-size=\"sm\"\u003eEuropean efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4578\" data-end=\"4587\"\u003e97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4588\" data-end=\"4614\"\u003e\n\u003ctd data-start=\"4588\" data-end=\"4606\" data-col-size=\"sm\"\u003eMPPT efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4606\" data-end=\"4614\"\u003e\u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4615\" data-end=\"4632\"\u003e\n\u003ctd data-start=\"4615\" data-end=\"4625\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4625\" data-end=\"4632\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4633\" data-end=\"4670\"\u003e\n\u003ctd data-start=\"4633\" data-end=\"4649\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4649\" data-end=\"4670\"\u003eWi-Fi, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4671\" data-end=\"4740\"\u003e\n\u003ctd data-start=\"4671\" data-end=\"4695\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4695\" data-end=\"4740\"\u003e-40°C to +60°C; power derating above 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4741\" data-end=\"4774\"\u003e\n\u003ctd data-start=\"4741\" data-end=\"4764\" data-col-size=\"sm\"\u003ePermissible humidity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4764\" data-end=\"4774\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4775\" data-end=\"4808\"\u003e\n\u003ctd data-start=\"4775\" data-end=\"4798\" data-col-size=\"sm\"\u003ePermissible altitude\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4798\" data-end=\"4808\"\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4809\" data-end=\"4832\"\u003e\n\u003ctd data-start=\"4809\" data-end=\"4823\" data-col-size=\"sm\"\u003eNoise level\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4823\" data-end=\"4832\"\u003e\u0026lt;60dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4833\" data-end=\"4861\"\u003e\n\u003ctd data-start=\"4833\" data-end=\"4853\" data-col-size=\"sm\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4853\" data-end=\"4861\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4862\" data-end=\"4937\"\u003e\n\u003ctd data-start=\"4862\" data-end=\"4873\" data-col-size=\"sm\"\u003eTopology\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4873\" data-end=\"4937\"\u003eNon-isolated on the solar side; isolated on the battery side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4938\" data-end=\"4990\"\u003e\n\u003ctd data-start=\"4938\" data-end=\"4961\" data-col-size=\"sm\"\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4961\" data-end=\"4990\"\u003eOVC II (DC), OVC III (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4991\" data-end=\"5093\"\u003e\n\u003ctd data-start=\"4991\" data-end=\"5026\" data-col-size=\"sm\"\u003eEnclosure dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5026\" data-end=\"5093\"\u003e456 × 750 × 268.5mm, excluding connectors and mounting brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5094\" data-end=\"5113\"\u003e\n\u003ctd data-start=\"5094\" data-end=\"5103\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5103\" data-end=\"5113\"\u003e51.9kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5114\" data-end=\"5151\"\u003e\n\u003ctd data-start=\"5114\" data-end=\"5124\" data-col-size=\"sm\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5124\" data-end=\"5151\"\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5152\" data-end=\"5201\"\u003e\n\u003ctd data-start=\"5152\" data-end=\"5171\" data-col-size=\"sm\"\u003eSurge protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5171\" data-end=\"5201\"\u003eType II (DC), Type II (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"fvuta6\" data-start=\"5203\" data-end=\"5235\"\u003eCompatibility and integration\u003c\/h2\u003e\n\u003cp data-start=\"5237\" data-end=\"5559\"\u003eThe inverter supports lead-acid and lithium-ion batteries within the 40–60V range. For lithium-ion batteries, the charging strategy adapts to the BMS through compatible communication. Exact compatibility depends on the battery model, BMS protocol, and firmware version. We recommend checking compatibility before purchase.\u003c\/p\u003e\n\u003cp data-start=\"5561\" data-end=\"5770\"\u003eThe photovoltaic strings must be designed so that the voltage, current, and power remain within the limits of each MPPT, including under the minimum and maximum temperature conditions at the installation site.\u003c\/p\u003e\n\u003ch2 data-section-id=\"14uwwk1\" data-start=\"5772\" data-end=\"5796\"\u003eProtection and safety\u003c\/h2\u003e\n\u003cp data-start=\"5798\" data-end=\"6175\"\u003eThe inverter includes DC reverse-polarity protection, AC output overcurrent protection, thermal protection, AC overvoltage protection, AC output short-circuit protection, DC component monitoring, AFCI, anti-islanding protection, a DC switch, insulation impedance detection, and residual current monitoring. Surge protection is Type II on the DC side and Type II on the AC side.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1idv9g\" data-start=\"6177\" data-end=\"6218\"\u003eStandards declared by the manufacturer\u003c\/h2\u003e\n\u003cp data-start=\"6220\" data-end=\"6351\"\u003e\u003cstrong data-start=\"6220\" data-end=\"6241\"\u003eGrid regulations:\u003c\/strong\u003e IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/p\u003e\n\u003cp data-start=\"6353\" data-end=\"6427\"\u003e\u003cstrong data-start=\"6353\" data-end=\"6372\"\u003eSafety and EMC:\u003c\/strong\u003e IEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/p\u003e\n\u003cp data-start=\"6429\" data-end=\"6584\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eSystem sizing, installation, and commissioning must be carried out by qualified personnel in accordance with DEYE documentation and applicable regulations.\u003c\/p\u003e","brand":"DEYE","offers":[{"title":"Default Title","offer_id":57937775886667,"sku":"SUN-14K-SG05LP3-EU-SM2","price":2060.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/1-2_866f5814-699e-4b3d-acab-929303a1ef26.png?v=1781008060","url":"https:\/\/solartech.eu\/pt\/products\/deye-14kw-three-phase-hybrid-inverter-sun-14k-sg05lp3-eu-sm2","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}