{"product_id":"victron-energy-phoenix-48v-500va-schuko-inverter","title":"Victron Energy Phoenix 48V 500VA Schuko Inverter","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+\u0026amp;]:mt-5\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"06484020-546e-43d3-b8ad-fc7099f28d11\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert dark\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe VE.Direct port can be connected to:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA computer (VE.Direct to USB cable required)\u003c\/li\u003e\n\u003cli\u003eApple and Android smartphones, tablets, MacBooks and other devices\u003cbr\u003e\n(VE.Direct Dual Bluetooth required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFully configurable:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow battery voltage alarm triggers and reset levels\u003c\/li\u003e\n\u003cli\u003eBattery voltage cut-off and battery restart levels\u003c\/li\u003e\n\u003cli\u003eDynamic disconnection: load-dependent cut-off level\u003c\/li\u003e\n\u003cli\u003eOutput voltage 210–245 V\u003c\/li\u003e\n\u003cli\u003eFrequency: 50 Hz or 60 Hz\u003c\/li\u003e\n\u003cli\u003eECO mode on\/off and ECO sensitivity level\u003c\/li\u003e\n\u003cli\u003eMonitoring:\n\u003cul\u003e\n\u003cli\u003eInput and output voltage\u003c\/li\u003e\n\u003cli\u003eCharging and alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003ePhoenix\u003c\/strong\u003e inverters are part of a range designed for high-quality performance, based on superior solar photovoltaic technology – \u003cstrong\u003eSinusMAX\u003c\/strong\u003e – featuring the unique ability to \u003cstrong\u003estart at maximum load\u003c\/strong\u003e.\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior technology – SinusMAX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Phoenix range of inverters, designed for photovoltaic panel systems, is created for professional use and is suitable for a wide range of applications.\u003c\/li\u003e\n\u003cli\u003eThe design focuses on optimal efficiency without compromising on performance, delivering a high-quality sinusoidal output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing HF hybrid technology, Phoenix offers a product:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh quality\u003c\/li\u003e\n\u003cli\u003eCompact in size\u003c\/li\u003e\n\u003cli\u003eLightweight\u003c\/li\u003e\n\u003cli\u003eHighly reliable\u003c\/li\u003e\n\u003cli\u003eCapable of supplying power for any type of load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStart-up at full load\u003c\/strong\u003e – A unique feature of \u003cstrong\u003eSinusMAX\u003c\/strong\u003e technology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide range of applications\u003c\/strong\u003e\u003cbr\u003e\n \u003cstrong\u003ePhoenix\u003c\/strong\u003e inverters are recommended for powering demanding loads. They can be integrated into \u003cstrong\u003estand-alone photovoltaic kits\u003c\/strong\u003e – independent photovoltaic systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVE.Direct communication port\u003c\/strong\u003e\u003cbr\u003e\nThis can be connected to computers, smartphones (Apple, Android), tablets, MacBooks and other compatible devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProven reliability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe toroidal transformer design has proven its long-term reliability.\u003c\/li\u003e\n\u003cli\u003ePhoenix inverters offer protection against:\n\u003cul\u003e\n\u003cli\u003eShort circuits\u003c\/li\u003e\n\u003cli\u003eOverload\u003c\/li\u003e\n\u003cli\u003eOverheating\u003c\/li\u003e\n\u003cli\u003eHigh ambient temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eECO mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn \u003cstrong\u003eECO\u003c\/strong\u003e mode, the inverter goes into standby when the load drops below a preset level.\u003c\/li\u003e\n\u003cli\u003eAfter entering standby mode, it activates for a short period (2.5 seconds, factory setting). If the load exceeds the preset level, the inverter remains on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRemote control on\/off\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan be connected to a two-pin connector, available on all Phoenix models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic transfer switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor low-power models, we recommend using the \u003cstrong\u003eFilax\u003c\/strong\u003e automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003eFilax has a very short transfer time (under 20 milliseconds), allowing computers or electronic equipment to operate without interruption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 86 x 172 x 275 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.9 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC power output at 25°C:\u003c\/strong\u003e 500VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower output at 25°C \/ 40°C:\u003c\/strong\u003e 400 \/ 350W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak power:\u003c\/strong\u003e 900W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC output voltage \/ frequency:\u003c\/strong\u003e 230VAC +\/- 3%, 50Hz or 60Hz +\/- 0.1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput voltage:\u003c\/strong\u003e 36.8 - 62.0V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow battery voltage alarm:\u003c\/strong\u003e 43.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery power cut-off:\u003c\/strong\u003e 37.2V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow battery voltage (self-regeneration):\u003c\/strong\u003e 56.0V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum efficiency:\u003c\/strong\u003e 91%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo-load power consumption:\u003c\/strong\u003e 9W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter protection:\u003c\/strong\u003e a - f\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -40 to +65°C (with fan)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum humidity:\u003c\/strong\u003e 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN-IEC 60335-1 \/ EN-IEC 62109-1 \/ UL 458 \/ EN 55014-1 \/ EN 55014-2 \/ IEC 61000-6-1 \/ IEC 61000-6-2 \/ IEC 61000-6-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":57062165119307,"sku":"PIN481501200","price":164.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/PIN481501200.png?v=1776539525","url":"https:\/\/solartech.eu\/products\/victron-energy-phoenix-48v-500va-schuko-inverter","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}