{"product_id":"uni-t-ut8805e-digital-bench-multimeter","title":"UNI-T UT8805E Digital Bench Multimeter","description":"\u003cp\u003eThis product comes with a 3-year warranty. The UT8805E is a desktop digital multimeter with a maximum display range of 199,999, featuring optional automatic or manual measurement, a colour display and a true RMS measurement function. Its circuit design utilises large-scale integrated (LSI) analogue-to-digital (A\/D) converters, a microprocessor, multifunctional measurement and highly stable thin-film resistor manufacturing technology, making it a digital multimeter with excellent performance. In addition, it features data storage, maximum\/minimum\/average measurement, comparison measurement, relative value measurement, peak value detection, trend graphing, and the ability to record and read up to 10,000 data records. Display of measurement results using bar graphs of readings or trend graphs. The display allows for dual data display; for example, when measuring AC voltages or currents, it also displays the frequency; when measuring temperature, it also displays the thermocouple resistance, etc.\u003cbr\u003e\nIt is a state-of-the-art electrical measuring instrument, suitable for use in electronics, communications, manufacturing, national defence, power generation, chemistry and other industries. This device strictly complies with safety standards IEC61010-1, EN61010-2-030, pollution degree II, overvoltage CAT I 1000V, CAT II 300V, double insulated, waterproof and dustproof with IP65 protection. It is an indispensable experimental instrument for various colleges.\u003c\/p\u003e\n\u003cp\u003eProduct specifications:\u003c\/p\u003e\n\u003cp\u003e- display type: 4.3\" diagonal TFT-LCD with a resolution of 480 x 272 px\u003cbr\u003e\n- number of display locations: 200,000\u003cbr\u003e\n- measurement speed: 2nd; readings\/measurement: 0.5000 10 readings\/s; 5000 readings\/s)\u003cbr\u003e\n- dual display: yes, simultaneous display of two quantities\u003cbr\u003e\n- DC voltage measurement: ranges from 200mV to 1000V\u003cbr\u003e\n- DC current measurement: ranges from 200μA to 10A\u003cbr\u003e\n- AC voltage measurement: 200 mV to 200 V AC\u003cbr\u003e\n- ranges\u003cbr\u003e\n- True-RMS AC current measurement: ranges from 2mA to 10A\u003cbr\u003e\n- Resistance measurement: ranges from 200Ω to 100MΩ (optional 2- and 4-wire resistance measurement)\u003cbr\u003e\n- Capacitance measurement: ranges from 2nF to 2000μF, frequency range: 1MH\/2000μF AC\u003cbr true-rms voltage from to\u003e\n- Circuit continuity and diode test: yes\u003cbr\u003e\n- Temperature measurement: with built-in thermocouple with cold-junction compensation\u003cbr\u003e\n- External thermocouple temperature measurement: yes, preset conversions for ITS-90, Pt100, and K, N, R, J, T, R, J, R, J thermocouples\u003cbr\u003e\n- various mathematical operations: maximum, minimum, average, standard deviation, pass\/fail, dBm, dB, relative measurement, histogram, trend graph, bar chart\u003cbr\u003e\n- supports USB, GPIB, RS-232C and LAN interfaces, USB-TMC, IEEE 488.1, compatible with the IEEE 488.1 command language and SCPI standard on VXI1\/2 SCPI-test set for the main multimeter\u003cbr\u003e\n- recording and storage of historical data\u003cbr\u003e\n- option to save data and configure settings to a USB drive\u003cbr\u003e\n- 1 GB NAND FLASH storage, high-capacity memory system and test data\u003cbr\u003e\n- menu in English and Chinese and online help system\u003cbr\u003e\n- software for the host PC\u003cbr\u003e\n- wide range of supply voltage parameters\u003cbr\u003e\n\u0026gt;-\u003c\/p\u003e\n\u003cp\u003e-\u003c\/p\u003e\n\u003cp\u003emeasured voltage: 1000 V (DC) \/ 750 V (AC)\u003cbr\u003e\n- 10 A input terminal protection: (CE) F1, internal slow-blow fuse 10 A \/ 250 V\u003cbr\u003e\n- μA, mA input terminal protection: (CE) F2, 250mA\/250V fast-acting fuse, 4-digit icon display\u003cbr\u003e\nFT. display; maximum value 200,000, 480 x 272 pixels\u003cbr\u003e\n- range selection: automatic or manual\u003cbr\u003e\n- polarity display: automatic\u003cbr\u003e\n- mathematical operations: Pass\/Fail, Relative, min\/max\/average, standard deviation, dBm, dB, Hold, histogram, trend graph, bar graph\/measurement\u003c\/p\u003e\n\u003cp\u003eranges:\u003cbr\u003e\n- 1. DC voltage measurement (range \/ input impedance \/ accuracy % (90 days) \/ (1 year)):\u003cbr\u003e\n200,000 mV \/ 10 MΩ or \u0026gt;10 GΩ \/ 0.008+0.004 \/ 0.01+0.004 \/ 0.01+0.004 \/ 10 Ω 0.004 \/ 10 Ω 0.008+0.003 \/ 0.01+0.003\u003cbr\u003e\n20.0000 V \/ 10 MΩ or \u0026gt;10 GΩ \/ 0.008+0.004 \/ 0.01+0.004\u003cbr\u003e\n200.000 V \/ 10 MΩ \/ 0.0003 + 0.003 Ω \/ 0.0003\u003cbr\u003e\n1000.00 V \/ 10 MΩ \/ 0.012+0.003 \/ 0.015+0.003\u003c\/p\u003e\n\u003cp\u003e- 2. DC current measurement (range \/ input voltage drop \/ accuracy % (90 days) \/ (1 year)):\u003cbr\u003e\n200.00, 0.50 μA \/\u003cbr\u003e\n\/ 0.055+0.005\u003cbr\u003e\n2.00000 mA \/ \u0026lt;0.3 V \/ 0.050+0.005 \/ 0.055+0.005\u003cbr\u003e\n20.0000 mA \/ \u0026lt;30 mV \/ 0.070+0.020 \/ 0.020 \/ 0.020 \/ 0.020 \u003cbr\u003e\n0.3 V \/ 0.060+0.008 \/ 0.070+0.008\u003cbr\u003e\n2.00000 A \/ \u0026lt;0.1 V \/ 0.150+0.020 \/ 0.170+0.020\u003cbr\u003e\n10.0000 A \/ \u0026lt;0.3 V \/+ \/ 0.0200 0.250+0.010\u003c\/p\u003e\n\u003cp\u003e- 3. Resistance measurement (ranges \/ max. test current \/ accuracy % (90 days) \/ (1 year)):\u003cbr\u003e\n200,000 Ω \/ 1mA \/ 0.012+0.005 \/ 0.030+0.005 \/ 0.030+0.0200 Ω \/ 0.000 Ω \/ 0.000 Ω 0.012+0.003 \/ 0.020+0.003\u003cbr\u003e\n20.0000 kΩ \/ 100μA \/ 0.012+0.003 \/ 0.020+0.003\u003cbr\u003e\n200,000 kΩ \/ 10 μA \/ 0.002+0.002+0.0020.003\u003cbr\u003e\n2.00000 MΩ \/ 1 μA \/ 0.020+0.004 \/ 0.040+0.004\u003cbr\u003e\n10.0000 MΩ \/ 500 nA \/ 0.100 + 0.004 \/ 0.250 + 0.004 \/ 0.250 + 0.004\u003cbr\u003e\n10,000 MΩ \/ 500 nA \/ 0.100+0.004 \/ 0.250+0.004\u003cbr\u003e\n100 MΩ \/ 000 000 ▀ 0.004 10 MΩ \/ 0.800+0.004 \/ 1.75+0.004\u003c\/p\u003e\n\u003cp\u003e- 4. True RMS AC voltage measurement (ranges \/ frequency range \/ accuracy % (90 days) \/ (1 year)):\u003cbr\u003e\n200,000 mV \/ 20 Hz \/ 20 Hz + 0.1–0.5 Hz \/ ¾ 1.5+0.1\u003cbr\u003e\n45 Hz to 20 kHz \/ 0.19+0.05 \/ 0.2+0.05\u003cbr\u003e\n20 kHz to 50 kHz \/ 1.0 ± 0.05 \/ 1.0 ± 0.05\u003cbr\u003e\n50 kHz \/+0.050 kHz \/+0.10 kHz 3.0+0.05\u003c\/p\u003e\n\u003cp\u003e2.00000 V \/ 20 Hz to 45 Hz \/ 1.5+0.10 \/ 1.5+0.10\u003cbr\u003e\n45 Hz to 20 kHz \/ 0.19+0.05 \/ 0.2+0.0,20 kHz \/ 0.20 kHz \/ 0.10 1.0+0.05 \/ 1.0+0.05\u003cbr\u003e\n50 kHz to 100 kHz \/ 3.0+0.05 \/ 3.0+0.05\u003c\/p\u003e\n\u003cp\u003e20.0000 V \/ 20 Hz to 45 Hz \/ 1.5+0.10+6 \/ 10.5+0.05\u003cbr\u003e\n20 kHz \/ 0.19+0.05 \/ 0.2+0.05\u003cbr\u003e\n20 kHz to 50 kHz \/ 1.0+0.05 \/ 1.0+0.05\u003cbr\u003e\n50 kHz to 100 kHz \/ 3.0+0.05 \/ 0.05,\u0026gt;\u0026lt;0.02,\u003cbr\u003e\nV \/ 20 Hz to 45 Hz \/ 1.5+0.10 \/ 1.5+0.10\u003cbr\u003e\n45 Hz to 20 kHz \/ 0.19+0.05 \/ 0.2+0.05\u003cbr\u003e\n20 kHz to 50 kHz \/ 1.0,+0.0,0.0, 0.05 kHz to 100 kHz \/ 3.0+0.05 \/ 3.0+0.05\u003c\/p\u003e\n\u003cp\u003e750,000 V \/ 20 Hz to 45 Hz \/ 1.5+0.10 \/ 1.5+0.10\u003cbr\u003e\n45 Hz to 20.5190 \/ 20.190 kHz\u003cbr\u003e\n20 kHz to 50 kHz \/ 1.0+0.05 \/ 1.0+0.05\u003cbr\u003e\n50 kHz to 100 kHz \/ 3.0+0.05 \/ 3.0+0.05\u003c\/p\u003e\n\u003cp\u003e- 5. True RMS \/ AC frequency range \/ measurement range 100 kHz \/ 10 days \/ current ():\u003cbr\u003e\n2.00000 mA \/ 20 Hz to 45 Hz \/ 1.5+0.10 \/ 1.5+0.10\u003cbr\u003e\n45 Hz to 2 kHz \/ 0.5+0.10 \/ 0.5+0.10\u003cbr\u003e\n2 kHz \/ 2 kHz + 0.10, 5 kHz \/ 2 kHz 2.5+0.20\u003c\/p\u003e\n\u003cp\u003e200.000 mA \/ 20 Hz to 45 Hz \/ 1.5+0.10 \/ 1.5+0.10\u003cbr\u003e\n45Hz to 2kHz \/ 0.5+0.10 \/ 0.5+0.10 kHz \/ 2kHz\u0026gt; \/ 0.5+0.10kHz\u0026gt; 2.5+0.20 \/ 2.5+0.20\u003c\/p\u003e\n\u003cp\u003e200,000 mA \/ 20 Hz to 45 Hz \/ 1.5+0.10 \/ 1.5+0.10\u003cbr\u003e\n45 Hz to 2 kHz \/ 0.3+0.10 \/ 0.10 \/ 1 Hz \u003cbr khz\u003e\n\u003c\/p\u003e\u003cp\u003e2.00000 A \/ 20 Hz to 45 Hz \/ 1.5+0.20 \/ 1.5+0.20\u003cbr\u003e\n45 Hz to 2 kHz \/ 0.5 ± 0.5 2 kHz to 10 kHz \/ 2.5 ± 0.20 \/ 2.5 ± 0.20\u003c\/p\u003e\n\u003cp\u003e10.0000 A \/ 20 Hz to 45 Hz \/ 1.5+0.15 \/ 1.5+0.15\u003cbr\u003e\n45 Hz to 2 kHz \/ +0.5, 5, 5 \/ 1.5\u003cbr\u003e\n2 kHz to 10 kHz \/ 2.5+0.20 \/ 2.5+0.20\u003c\/p\u003e\n\u003cp\u003e- 6. Capacitance measurement (ranges \/ max. test current \/ accuracy % (90 days) \/ (1 year)):\u003cbr\u003e\n2,000 nF \/ 0.5 μA + 1.0 \/ 0.5 μA + 1.02\u003cbr\u003e\n20.00 nF \/ 1 μA \/ 1+0.5 \/ 1+0.5\u003cbr\u003e\n200.0 nF \/ 10 μA \/ 1+0.5 \/ 1+0.5\u003cbr\u003e\n2,000 μF \/ 100 μA \/ 1+0.5 \/ 1+0.5 \/+0.5 \/+0.5 μF \/ 0.5 \/ 0.5 μF 1+0.5\u003cbr\u003e\n200.0 μF \/ 1 mA \/ 1+0.5 \/ 1+0.5\u003cbr\u003e\n2,000 mF \/ 1 mA \/ 2+0.5 \/ 2+0.5\u003c\/p\u003e\n\u003cp\u003e- 7. Temperature measurement (thermocouple type \/ cell temperature range \/ accuracy):\u003cbr\u003e an) α=0.00385 \/ -200°C to 660°C \/ 0.16°C\u003cbr\u003e\nB \/ 0°C to 1820°C \/ 0.76 °C\u003cbr\u003e\nE \/ -270°C to 1000°C \/ 0.5 °C\u003cbr\u003e\nJ \/°C \/ -200°C \/ -200°C\u003cbr\u003e\nK \/ -270°C to 1370°C \/ 0.5 °C\u003cbr\u003e\nN \/ -270°C to 1300°C \/ 0.5 °C\u003cbr\u003e\nR \/ -50°C to 1760°C \/ 0.5 °C\u003cbr\u003e\nS \/ -50°C to \/17.6°C\u003cbr\u003e\n-270°C to 400°C \/ 0.5°C\u003c\/p\u003e\n\u003cp\u003e- 8. Frequency and duty cycle measurement (ranges \/ accuracy % (90 days) \/ (1 year)):\u003cbr\u003e\n20 Hz to 2 kHz \/ 0.01 + 0.003 \/ 0.01 + 0.02 kHz \/ 0.02 kHz \/ 0.02 kHz \/ 0.02 kHz \/ 0.01 + 0.003 \/ 0.01 + 0.003\u003cbr\u003e\n20 kHz to 200 kHz \/ 0.01 + 0.003 \/ 0.01 + 0.003\u003cbr\u003e\n200 kHz to 1 MHz \/ 0.01 + 0.001 AC \/ 0.001 + 0.005 AC in the voltage range 200 mV to 750 V.\u003c\/p\u003e\n\u003cp\u003e- 9. Circuit continuity and diode testing\u003cbr\u003e\nA constant current source of 1 mA ± 5% is used to measure the resistance or voltage drop across the diode.\u003cbr\u003e\nThe open-circuit voltage is \u0026lt; 8V. The circuit continuity measurement threshold is adjustable. Buzzer indication option\u003cbr\u003e\nbuzzer.\u003c\/p\u003e\n\u003cp\u003eGeneral characteristics and mechanical properties:\u003c\/p\u003e\n\u003cp\u003e- power supply: AC 90V–110V, 45–440Hz; AC 110V–132V, 45–440Hz; AC 200V–240V, 45–66Hz; AC 216V–264V, 45–66Hz\u003cbr\u003e\n- power consumption: max. 20W\u003cbr\u003e\n- operating environment: 0°C–28°C \u0026lt;90%; 28°C–40°C \u0026lt;75%; 40°C–55°C \u0026lt;50% (non-condensing)\u003cbr\u003e\n- Altitude: ≤2000 m\u003cbr\u003e\n- Dimensions: 260 mm x 116 mm x 332 mm\u003cbr\u003e\n- Weight: 4.4 kg\u003cbr\u003e\n- Colour: off-white and grey\u003c\/p\u003e\n\u003cp\u003e\u0026gt; Individual multimeter packaging contents:\u003c\/p\u003e\n\u003cp\u003e\u0026gt; UT8805E: 1 pc\u003cbr\u003e\n- three-core power cable: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- USB connection cable: 1 pc\u003cbr\u003e\n- RS232 connection cable: 1 pc\u003cbr\u003e\n- UT8805E quick start guide: 1 pc\u003cbr\u003e\n- PC warranty card: UT8805 PC:-1805 PC:-1805 set\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003c\/p\u003e\n\u003cp\u003ehttps:\/\/instruments.uni-trend.com\/EU-EN\/multimeters\/ut8000e.html\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062164726091,"sku":"07730155","price":532.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07730155.jpg?v=1776539517","url":"https:\/\/solartech.eu\/products\/uni-t-ut8805e-digital-bench-multimeter","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}