{"product_id":"uni-t-ut207b-clamp-meter","title":"UNI-T UT207B Clamp Meter","description":"\u003cp\u003eUNI-T UT207B Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT207B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 10,000,000 V in the range of 1,000,000 V at 400 Hz and low voltage (LV) from 10 Hz to 1 MHz. It features protection against voltages exceeding 1,000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times\/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only \u0026lt;50μA, which effectively extends battery life. The power-saving function can be disabled.\u003c\/p\u003e\n\u003cp\u003eProduct specifications:\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage and current, resistance, diodes, continuity, capacitance\u003cbr\u003e\n- automatic polarity display\u003cbr\u003e\n- measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range\u003cbr\u003e of low-voltage (LV) frequency in the range from 10 Hz to 1 MHz\u003cbr\u003e\n- capacitance measurement from 60 nF to 60 mF\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- Multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages higher than 10V\/0V - contact function without NC\u003cbr\u003e\n- live conductors\u003cbr\u003e\n- LoZ V function ~ measurement with low input impedance (approx. 2kΩ) of the device\u003cbr\u003e\n- INRUSH function – measurement of transients up to 100 ms in length – inrush current at device start-up up to 3000 A with additional flexible loop\u003cbr\u003e\n- LPF ACV measurement function on nf2H5 filter (approx. inverters and variable frequency drives\u003cbr\u003e\n- Frequency\/duty cycle measurement function\u003cbr\u003e\n- Choice between automatic or manual range switching\u003cbr\u003e\n- Built-in lamp\u003cbr\u003e\n- Accuracy of current and voltage measurement is guaranteed when using the range between 5% and 100% of the full scale; at 5% of the full scale, a technical adjustment is required\u003cbr\u003e\n\u0026gt;\u003cbr\u003e\nParameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 40Hz ~ 400Hz ±(2.0%+9)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(2.0%+A)\u003cbr\u003e+1 40Hz ~ 400Hz ±(2.0%+5)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz\u003cbr\u003e\n- Overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003e2. AC inrush current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 A \/ 0.010 A \/ 40 Hz ~ 400 Hz ±(10.0% + 10)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n1000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n- overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003ewith flexible current loop\u003cbr\u003e\n30.00A \/ 0.000Hz \/ 40.010Hz ±(10.0%+10)\u003cbr\u003e\n300.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n3000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10) overload protection\u003cbr\u003e\n-10 3000A\u003c\/p\u003e\n\u003cp\u003e3. DC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ ±(2.0%+5)\u003cbr\u003e\n600.0A \/ 0.100A \/ ±(2.0%+5)\u003cbr\u003e\n1000.0A \/ 1A \/ ±(2.0%+5) overload protection\u003cbr\u003e\n2.0%\/\u0026gt;-5 1000A\u003c\/p\u003e\n\u003cp\u003e4. AC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000V \/ 0.001V \/ 40Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00V \/ 0.010V \/ 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V \/ 40 Hz ~ 400 Hz ±(1.0% + 8)\u003cbr\u003e\n1000.0V \/ 1V \/ 40Hz ~ 400Hz ±(1.0%+8)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz\u003cbr\u003e\n- Overload protection at 1000 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\ninput overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e6. AC LPF V (measurement with low input impedance approx. 2 kΩ)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\n- Input overload protection rm approx. 2kΩ\u003c\/p\u003e\n\u003cp\u003e7. DC voltage measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 mV \/ 0.100 mV \/ ±(0.8%+3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ±(0.5%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ +0.05 V \/ 0.100 V \/ ±(0.5%+3)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(0.5%+3)\u003cbr\u003e\n- overload protection at 1000Vrms\u003cbr\u003e\n- input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e8. Resistance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0Ω \/ 0.1Ω \/ ±(1.0%+3)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ % + 0.0,0,0,0,0,0,0,0,Ω \/\u0026gt; 0.1 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n- overload protection at 1000 Vrms open-circuit voltage approx.\u003cbr\u003e\n- 1 V\u003c\/p\u003e\n\u003cp\u003e9. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 30Ω, the continuity signal emits a beep\u003cbr\u003e\n- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep\u003cbr\u003e\n- uncertainty between 31Ω and 69Ω\u003cbr\u003e\n- 600Ω, with a resolution of 0.1Ω\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e10. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 3.0V\u003cbr\u003e\n- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V\u003c\/p\u003e\n\u003cp\u003e11. Capacitance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n60.00 nF \/ 0.01 nF \/ ±(4.0%+25)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ±(4.0%+5)\u003cbr\u003e\n6,000 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ±(4.0%+5)\u003cbr\u003e\n6.000 mF \/ 0.001 mF \/ ±10.0% \/ 0.1 μF \/ 0.1 μF \/ ±(4.0%+5) \/ ±10.0%+9\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e12. Frequency measurement and duty cycle (duty)\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 1 MHz \/ 0.01 Hz to 1 kHz \/ ± (0.1% + 3)\u003cbr\u003e\nduty cycle: 10% to 99.1% \/ ±99.0% \/ ±7)\u003c\/p\u003e\n\u003cp\u003e- Note 1) Measurement sensitivity:\u003cbr\u003e\n10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\n100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\nNote: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:\u003cbr\u003e\n2Vpp ≤ input amplitude ≤ 20V p-p\u003c\/p\u003e\n\u003cp\u003e- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e13. Non-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- Auto power off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 43 x 45 mm\u003cbr\u003e\n- Product dimensions: 81 x 27\/4 x 81 x 27 mm. Product weight: 450g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT207B multimeter clip: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- 1.5 V battery (R03): 3 pcs\u003c\/p\u003e\n\u003cp\u003e- user manual\u003cbr\u003e\n- 1 pc\u003cbr\u003e\n- user manual\u003cbr\u003e\nPackaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 10 pcs\u003cbr\u003e\n- standard box dimensions: 355 mm x 330 mm x 315 mm\u003cbr\u003e\n- standard gross weight per box: 7.1 kg\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003cbr\u003e\nhttps:\/\/www.uni-trend\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169805131,"sku":"07720264","price":116.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720264.jpg?v=1776539661","url":"https:\/\/solartech.eu\/products\/uni-t-ut207b-clamp-meter","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}