{"product_id":"uni-t-ut204r-clamp-meter","title":"UNI-T UT204R Clamp Meter","description":"\u003cp\u003eUNI-T UT204R Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT204R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times\/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on low-voltage distribution lines in CAT II. With the included Type K thermocouple (nickel-chromium-nickel-silicon temperature sensor), it allows temperature measurement from -40°C to 1000°C. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is \u0026lt;11μA, which effectively extends the battery life to approximately 400 hours.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of voltage, current and high-voltage frequency up to 600 V\u003cbr\u003e\n- frequency measurement from 10 Hz to 10 MHz\u003cbr\u003e\n- Measurement capabilities\u003cbr\u003e\n- 60 mF\u003cbr\u003e\n- Temperature measurement from -40 to +1000 °C\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages exceeding 600 V in intervals\u003cbr\u003e\n- Non-contact detection of live voltages and switching accuracy of live conductors\u003cbr\u003e\n-\u003cbr\u003e\nguaranteed within the range of 1% to 100% of the range\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 50Hz ~ 100Hz ± (2.0% +5)\u003cbr\u003e\n600.0A \/ 0.100A \/ 50Hz ~ 100Hz ± (2.0% + 5) The accuracy of AC frequency monitoring in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz\u003cbr\u003e\n- overload protection at 620 A\u003c\/p\u003e\n\u003cp\u003e2. DC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 A \/ 0.010 A \/ ± (2.0% + 5)\u003cbr\u003e\n600.0 A \/ 0.100 A \/ ± (2.0% + 5)\u003cbr\u003e\n- overload protection at 620 A\u003cbr\u003e\n\u0026gt;\u003c\/p\u003e\n\u003cp\u003e\u0026gt;\u003cbr\u003e\n6,000V \/ 0.001V \/ 10Hz ~ 10kHz ± (1.0% +5)\u003cbr\u003e\n60.00V \/ 0.010V \/ 10Hz ~ 10kHz ± (0.8% \/ 0.0% +5) \/ 10Hz ~ 10kHz ± (0.8% +5)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to 60 kHz ± (0.5% + 2) at a resolution of 0.01 Hz to 0.01 kHz\u003cbr\u003e\n- input overload protection\u003cbr\u003e\n- 0.01 kHz\u003cbr\u003e\n- overload protection\u003cbr\u003e\n- 60\/0 V rm. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e4. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600.0 mV \/ 0.100 mV \/ ± (0.7% +3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ± (0.5% +2)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ ±0.001 V \/ ± (0.5% +2) \/ 0.100 V \/ ± (0.5% +2)\u003cbr\u003e\n- input impedance approx. 10MΩ\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e5. Resistance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600.0Ω \/ 0.1Ω \/ ± (1.0% +2)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ 60.8 kΩ ±2.0 kΩ 0.1 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ± (2.5% +5)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ± (2.5% +5)\u003cbr\u003e\n- overload protection at 600 Vrms open circuit\u003cbr\u003e\n- approx. 1V\u003c\/p\u003e\n\u003cp\u003e6. Capacitance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 nF \/ 0.01 nF \/ ± (4.0% +5)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ± (4.0% +5)\u003cbr\u003e\n6000 μF \/ 0.001 μF \/ ±4.0% +5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ± (4.0% +5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ± (4.0% +5)\u003cbr\u003e\n6,000 mF \/ 0.001 mF \/ ± 10.0%\u003cbr mf\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e7. Temperature measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e-40°C to +40°C \/ 1°C \/ ± 4°C\u003cbr\u003e\n+40°C to +500°C\/1°C \/ ± (1.5% +5)\u003cbr\u003e\n+500°C to +1000°C\/±2°C\/1.5°C\u003c\/p\u003e\n\u003cp\u003e-40°F to +104°F \/ 1°F \/ ± 6°F\u003cbr\u003e\n+104°F to +932°F \/ 1°F \/ ± (2.0 +6)\u003cbr\u003e\n+932°F to +1832°F \/ 1°F \/ ± 4\u003cbr\u003e\n%\u003cbr\u003e\nFrequency and load measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 10 MHz \/ 0.01 Hz to 0.01 MHz \/ ± (0.1% +4)\u003cbr\u003e\nload: 0.1 to 99.9% \/ 0.1% \/ ±5)\u003cbr\u003e\nNote\/+5. Sensitivity:\u003cbr\u003e\n≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS\u003c\/p\u003e\n\u003cp\u003e- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p\u003cbr\u003e\nFrequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency\u003cbr\u003e\nOperating frequency\u003cbr\u003e\n1 kHz 30.0% ~ 70.0%\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e9. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer\u003cbr\u003e\n- if the measured resistance is greater than 31Ω, the open-circuit signal does not emit a buzzer\u003cbr\u003e\n- uncertainty in the range from 10Ω to 31Ω. 600Ω range\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e10. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 4.0V\u003cbr\u003e\n- measurement in the range of 6.000V\u003cbr\u003e\u003cbr\u003e\nNon-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of maximum and minimum values\u003c\/p\u003e\n\u003cp\u003e- relative measurement of maximum and minimum. Mode (ratio) for voltage and capacitance measurement: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- auto-off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 37 mm x 25 mm\u003cbr\u003e\n- Product dimensions: 631.5 mm x 631 mm\u003cbr\u003e\n- net product weight: 235 g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT204R clamp multimeter: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- K-type thermocouple up to 101 V: 0 pcs\u003c\/p\u003e\n\u003cp\u003e(R03): 2 pcs\u003cbr\u003e\n- user manual: 1 pc\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 40 pcs\u003cbr\u003e\n- standard box dimensions: 485 mm x 295 mm x 385 mm\u003cbr\u003e\n- standard gross weight per box: 16\/F: 7 kg\u003cbr\u003e\u003cbr uni-trend\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169903435,"sku":"07720258","price":75.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720258.jpg?v=1776539666","url":"https:\/\/solartech.eu\/products\/uni-t-ut204r-clamp-meter","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}