{"product_id":"leader-dc-protection-box-for-2-strings","title":"Leader DC Protection Box for 2 Strings","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-6a50bbbe-fa04-83eb-b76e-1e4c5b54e433-9\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a50bbbe-fa04-83eb-b76e-1e4c5b54e433-9\" data-turn-id-container=\"request-6a50bbbe-fa04-83eb-b76e-1e4c5b54e433-9\" data-testid=\"conversation-turn-16\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden @[53.5rem]\/main:[--thread-content-max-width:48rem] relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9759f49c-5b21-5270-98b1-d65fa0ae0fea\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5.6-sol-wm\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"43\" data-end=\"341\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Leader LDDB-PV2\/2-1000-M protection box is designed for photovoltaic installations with two PV strings and an operating voltage of up to 1,000V DC. It protects DC circuits against overvoltage and allows the installation to be quickly isolated during maintenance work or in the event of a fault.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"343\" data-end=\"728\"\u003eAll components are pre-assembled inside an IP65-rated enclosure that is resistant to water, dust, and UV radiation, making it suitable for both indoor and outdoor installation. The 2-input\/2-output configuration enables the safe connection of two photovoltaic strings to the inverter, reducing installation time and providing a reliable solution for residential and commercial systems.\u003c\/p\u003e\n\u003cp data-start=\"730\" data-end=\"957\"\u003eThe box is equipped with two Type II surge protection devices (SPDs) rated for 1,000V DC, a 63A DC switch-disconnector, and four photovoltaic fuses, providing a high level of protection for the photovoltaic panels and inverter.\u003c\/p\u003e\n\u003cp data-start=\"959\" data-end=\"1125\"\u003eThanks to its robust construction and high-quality components, the LDDB-PV2\/2-1000-M helps improve the safety and reliability of the entire photovoltaic installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"rbss9i\" data-start=\"1127\" data-end=\"1145\"\u003eMain advantages\u003c\/h2\u003e\n\u003cul data-start=\"1147\" data-end=\"1487\"\u003e\n\u003cli data-section-id=\"ewzlop\" data-start=\"1147\" data-end=\"1192\"\u003eProtection box for two photovoltaic strings\u003c\/li\u003e\n\u003cli data-section-id=\"ymvylz\" data-start=\"1193\" data-end=\"1223\"\u003eMaximum voltage of 1,000V DC\u003c\/li\u003e\n\u003cli data-section-id=\"1jrzdoe\" data-start=\"1224\" data-end=\"1256\"\u003e2-input\/2-output configuration\u003c\/li\u003e\n\u003cli data-section-id=\"17soar\" data-start=\"1257\" data-end=\"1279\"\u003eIP65-rated enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"b9ke1x\" data-start=\"1280\" data-end=\"1321\"\u003eTwo Type II DC surge protection devices\u003c\/li\u003e\n\u003cli data-section-id=\"15xzcp5\" data-start=\"1322\" data-end=\"1350\"\u003e63A DC switch-disconnector\u003c\/li\u003e\n\u003cli data-section-id=\"cfre6u\" data-start=\"1351\" data-end=\"1376\"\u003eFour photovoltaic fuses\u003c\/li\u003e\n\u003cli data-section-id=\"cmp254\" data-start=\"1377\" data-end=\"1403\"\u003ePre-assembled components\u003c\/li\u003e\n\u003cli data-section-id=\"13gifg1\" data-start=\"1404\" data-end=\"1424\"\u003eQuick installation\u003c\/li\u003e\n\u003cli data-section-id=\"13gnewn\" data-start=\"1425\" data-end=\"1487\"\u003eSuitable for residential and commercial photovoltaic systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"19xnbiw\" data-start=\"1489\" data-end=\"1516\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1518\" data-end=\"2127\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1518\" data-end=\"1556\"\u003e\n\u003ctr data-start=\"1518\" data-end=\"1556\"\u003e\n\u003cth data-start=\"1518\" data-end=\"1529\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eCategory\u003c\/th\u003e\n\u003cth data-start=\"1529\" data-end=\"1539\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1539\" data-end=\"1556\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1571\" data-end=\"2127\"\u003e\n\u003ctr data-start=\"1571\" data-end=\"1631\"\u003e\n\u003ctd data-start=\"1571\" data-end=\"1587\" data-col-size=\"sm\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1587\" data-end=\"1607\"\u003eNumber of strings\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1607\" data-end=\"1631\"\u003e2 inputs \/ 2 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1632\" data-end=\"1676\"\u003e\n\u003ctd data-start=\"1632\" data-end=\"1640\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1640\" data-end=\"1655\"\u003eProduct code\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1655\" data-end=\"1676\"\u003eLDDB-PV2\/2-1000-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1677\" data-end=\"1718\"\u003e\n\u003ctd data-start=\"1677\" data-end=\"1687\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1687\" data-end=\"1705\"\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1705\" data-end=\"1718\"\u003e1,000V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1719\" data-end=\"1748\"\u003e\n\u003ctd data-start=\"1719\" data-end=\"1731\" data-col-size=\"sm\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd data-start=\"1731\" data-end=\"1739\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1739\" data-end=\"1748\"\u003eHA-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1749\" data-end=\"1789\"\u003e\n\u003ctd data-start=\"1749\" data-end=\"1761\" data-col-size=\"sm\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1761\" data-end=\"1781\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1781\" data-end=\"1789\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1790\" data-end=\"1820\"\u003e\n\u003ctd data-start=\"1790\" data-end=\"1796\" data-col-size=\"sm\"\u003eSPD\u003c\/td\u003e\n\u003ctd data-start=\"1796\" data-end=\"1804\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1804\" data-end=\"1820\"\u003eLD-SP3P-40KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1821\" data-end=\"1849\"\u003e\n\u003ctd data-start=\"1821\" data-end=\"1827\" data-col-size=\"sm\"\u003eSPD\u003c\/td\u003e\n\u003ctd data-start=\"1827\" data-end=\"1838\" data-col-size=\"sm\"\u003eQuantity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1838\" data-end=\"1849\"\u003e2 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1850\" data-end=\"1877\"\u003e\n\u003ctd data-start=\"1850\" data-end=\"1856\" data-col-size=\"sm\"\u003eSPD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1856\" data-end=\"1863\"\u003eType\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1863\" data-end=\"1877\"\u003eType II DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1878\" data-end=\"1912\"\u003e\n\u003ctd data-start=\"1878\" data-end=\"1890\" data-col-size=\"sm\"\u003eDC switch\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1890\" data-end=\"1898\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1898\" data-end=\"1912\"\u003eLDMT-4P-63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1913\" data-end=\"1948\"\u003e\n\u003ctd data-start=\"1913\" data-end=\"1925\" data-col-size=\"sm\"\u003eDC switch\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1925\" data-end=\"1941\"\u003eRated current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1941\" data-end=\"1948\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1949\" data-end=\"1988\"\u003e\n\u003ctd data-start=\"1949\" data-end=\"1957\" data-col-size=\"sm\"\u003eFuses\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1957\" data-end=\"1965\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1965\" data-end=\"1988\"\u003ePV0911-1P\/BX0234-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1989\" data-end=\"2019\"\u003e\n\u003ctd data-start=\"1989\" data-end=\"1997\" data-col-size=\"sm\"\u003eFuses\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1997\" data-end=\"2008\"\u003eQuantity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2008\" data-end=\"2019\"\u003e4 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2020\" data-end=\"2067\"\u003e\n\u003ctd data-start=\"2020\" data-end=\"2035\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2035\" data-end=\"2051\"\u003eMounting type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2051\" data-end=\"2067\"\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2068\" data-end=\"2127\"\u003e\n\u003ctd data-start=\"2068\" data-end=\"2082\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2082\" data-end=\"2088\"\u003eUse\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2088\" data-end=\"2127\"\u003ePhotovoltaic systems with 2 strings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"14bu82z\" data-start=\"2129\" data-end=\"2145\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp data-start=\"2147\" data-end=\"2163\"\u003eCompatible with:\u003c\/p\u003e\n\u003cul data-start=\"2165\" data-end=\"2294\"\u003e\n\u003cli data-section-id=\"1mmk5xm\" data-start=\"2165\" data-end=\"2184\"\u003eOn-grid inverters\u003c\/li\u003e\n\u003cli data-section-id=\"1er3s2a\" data-start=\"2185\" data-end=\"2203\"\u003eHybrid inverters\u003c\/li\u003e\n\u003cli data-section-id=\"tt2se4\" data-start=\"2204\" data-end=\"2248\"\u003ePhotovoltaic systems rated up to 1,000V DC\u003c\/li\u003e\n\u003cli data-section-id=\"gshv0p\" data-start=\"2249\" data-end=\"2294\"\u003ePhotovoltaic installations with two strings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2296\" data-end=\"2464\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eInstallation, configuration, and commissioning must be carried out by qualified personnel in accordance with the manufacturer’s instructions and applicable regulations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Leader","offers":[{"title":"Default Title","offer_id":57964171919691,"sku":"2STLEA","price":134.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/leader2stringuri.png?v=1785238149","url":"https:\/\/solartech.eu\/it\/products\/leader-dc-protection-box-for-2-strings","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}