{"product_id":"deye-16kw-three-phase-hybrid-inverter-sun-16k-sg05lp3-eu-sm2","title":"DEYE 16kW Three-Phase Hybrid Inverter SUN-16K-SG05LP3-EU-SM2","description":"\u003cp data-start=\"65\" data-end=\"150\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/04\/26\/BDatasheetSUN-14-20K-SG05LP3-EU-SM220260424en.pdf\"\u003eDownload the datasheet\u003c\/a\u003e\u003cbr data-start=\"87\" data-end=\"90\"\u003e\u003ca href=\"https:\/\/www.deyeinverter.com\/deyeinverter\/2026\/03\/19\/rand\/8499\/%E3%80%90b%E3%80%91manual_sun-14-20k-sg05lp3-eu-sm2_20260319_en.pdf\"\u003eDownload the manual\u003c\/a\u003e\u003cbr data-start=\"109\" data-end=\"112\"\u003e\u003ca href=\"https:\/\/hqcdn.hqsmartcloud.com\/deyeinverter\/2025\/08\/02\/certificate_europe_en50549-10.pdf\"\u003eDownload the Declaration of Conformity\u003c\/a\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"152\" data-end=\"499\"\u003eThe DEYE SUN-16K-SG05LP3-EU-SM2 is a 16kW three-phase hybrid inverter designed for photovoltaic installations with low-voltage batteries. Its two 40–60V battery inputs and maximum charging\/discharging current of 300A provide flexibility for energy storage systems intended for large homes, guesthouses, offices, workshops, and commercial premises.\u003c\/p\u003e\n\u003cp data-start=\"501\" data-end=\"919\"\u003eThe unit manages photovoltaic production, battery storage, the grid, and electrical loads. The AC coupling function allows integration into an existing photovoltaic installation, while diesel generator support provides an additional power supply and energy storage option. Six programmable charging and discharging periods allow operation to be adapted to the user’s consumption profile and energy management strategy.\u003c\/p\u003e\n\u003cp data-start=\"921\" data-end=\"1315\"\u003eWith a maximum PV input power of 25.6kW, two MPPT trackers, and four strings in a 2+2 configuration, the model can manage two separate photovoltaic orientations or installation areas. The 100% unbalanced three-phase output allows each phase to supply up to 50% of the inverter’s rated power. In off-grid operation, the inverter can support a peak output of twice its rated power for 10 seconds.\u003c\/p\u003e\n\u003ch2 data-section-id=\"hxesp5\" data-start=\"1317\" data-end=\"1333\"\u003eMain features\u003c\/h2\u003e\n\u003cul data-start=\"1335\" data-end=\"1933\"\u003e\n\u003cli data-section-id=\"1d57ziu\" data-start=\"1335\" data-end=\"1369\"\u003e16kW three-phase hybrid inverter\u003c\/li\u003e\n\u003cli data-section-id=\"r44dr2\" data-start=\"1370\" data-end=\"1429\"\u003eCompatible with 40–60V lead-acid or lithium-ion batteries\u003c\/li\u003e\n\u003cli data-section-id=\"1lefh70\" data-start=\"1430\" data-end=\"1450\"\u003eTwo battery inputs\u003c\/li\u003e\n\u003cli data-section-id=\"wasiqv\" data-start=\"1451\" data-end=\"1501\"\u003eMaximum charging and discharging current of 300A\u003c\/li\u003e\n\u003cli data-section-id=\"9vsifv\" data-start=\"1502\" data-end=\"1553\"\u003eTwo MPPT trackers with a 2+2 string configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1cd30r7\" data-start=\"1554\" data-end=\"1609\"\u003eSix programmable battery charging\/discharging periods\u003c\/li\u003e\n\u003cli data-section-id=\"1yg08fp\" data-start=\"1610\" data-end=\"1674\"\u003eAC coupling for integration into existing photovoltaic systems\u003c\/li\u003e\n\u003cli data-section-id=\"o5qel5\" data-start=\"1675\" data-end=\"1752\"\u003eUp to 10 inverters connected in parallel for on-grid and off-grid operation\u003c\/li\u003e\n\u003cli data-section-id=\"17m23t8\" data-start=\"1753\" data-end=\"1795\"\u003eSupports batteries connected in parallel\u003c\/li\u003e\n\u003cli data-section-id=\"1u0higp\" data-start=\"1796\" data-end=\"1845\"\u003eSupports energy storage from a diesel generator\u003c\/li\u003e\n\u003cli data-section-id=\"twubsq\" data-start=\"1846\" data-end=\"1870\"\u003e100% unbalanced output\u003c\/li\u003e\n\u003cli data-section-id=\"9brdjf\" data-start=\"1871\" data-end=\"1908\"\u003eWi-Fi, RS485, and CAN communication\u003c\/li\u003e\n\u003cli data-section-id=\"17ke66u\" data-start=\"1909\" data-end=\"1933\"\u003eIP65 protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1344z7h\" data-start=\"1935\" data-end=\"1948\"\u003eAdvantages\u003c\/h2\u003e\n\u003cp data-start=\"1950\" data-end=\"2121\"\u003e\u003cstrong data-start=\"1950\" data-end=\"1994\"\u003eSuitable power for higher energy demand:\u003c\/strong\u003e The 16kW output can support large three-phase residential and commercial applications, within the limits of the system design.\u003c\/p\u003e\n\u003cp data-start=\"2123\" data-end=\"2239\"\u003e\u003cstrong data-start=\"2123\" data-end=\"2157\"\u003eFast charging and discharging:\u003c\/strong\u003e A current of up to 300A enables efficient use of a properly sized battery system.\u003c\/p\u003e\n\u003cp data-start=\"2241\" data-end=\"2392\"\u003e\u003cstrong data-start=\"2241\" data-end=\"2279\"\u003eEfficient use of solar production:\u003c\/strong\u003e A PV input capacity of up to 25.6kW allows flexible DC sizing, provided that all electrical limits are observed.\u003c\/p\u003e\n\u003cp data-start=\"2394\" data-end=\"2556\"\u003e\u003cstrong data-start=\"2394\" data-end=\"2448\"\u003eImproved management of unevenly distributed loads:\u003c\/strong\u003e The unbalanced output function is better suited to situations where loads differ from one phase to another.\u003c\/p\u003e\n\u003cp data-start=\"2558\" data-end=\"2646\"\u003e\u003cstrong data-start=\"2558\" data-end=\"2583\"\u003eProgrammable control:\u003c\/strong\u003e Six charging and discharging periods help optimise energy use.\u003c\/p\u003e\n\u003cp data-start=\"2648\" data-end=\"2769\"\u003e\u003cstrong data-start=\"2648\" data-end=\"2670\"\u003eExpandable system:\u003c\/strong\u003e Up to 10 units can operate in parallel, allowing the installation to be expanded at a later stage.\u003c\/p\u003e\n\u003ch2 data-section-id=\"w3ml15\" data-start=\"2771\" data-end=\"2798\"\u003eRecommended applications\u003c\/h2\u003e\n\u003cul data-start=\"2800\" data-end=\"3111\"\u003e\n\u003cli data-section-id=\"42b0ui\" data-start=\"2800\" data-end=\"2845\"\u003eLarge homes with a three-phase power supply\u003c\/li\u003e\n\u003cli data-section-id=\"qko4ke\" data-start=\"2846\" data-end=\"2894\"\u003eGuesthouses, villas, and residential buildings\u003c\/li\u003e\n\u003cli data-section-id=\"1uztdwq\" data-start=\"2895\" data-end=\"2928\"\u003eOffices and commercial premises\u003c\/li\u003e\n\u003cli data-section-id=\"1skiv0q\" data-start=\"2929\" data-end=\"2972\"\u003eWorkshops and small production facilities\u003c\/li\u003e\n\u003cli data-section-id=\"116p8fy\" data-start=\"2973\" data-end=\"3064\"\u003eNew installations with energy storage or upgrades to existing systems through AC coupling\u003c\/li\u003e\n\u003cli data-section-id=\"1u1d6n6\" data-start=\"3065\" data-end=\"3111\"\u003eSystems with a generator backup power source\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"19xnbiw\" data-start=\"3113\" data-end=\"3140\"\u003eTechnical specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3142\" data-end=\"5043\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3142\" data-end=\"3167\"\u003e\n\u003ctr data-start=\"3142\" data-end=\"3167\"\u003e\n\u003cth data-start=\"3142\" data-end=\"3158\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3158\" data-end=\"3167\" data-col-size=\"md\" class=\"last:pe-10\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3178\" data-end=\"5043\"\u003e\n\u003ctr data-start=\"3178\" data-end=\"3212\"\u003e\n\u003ctd data-start=\"3178\" data-end=\"3186\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"3186\" data-end=\"3212\" data-col-size=\"md\"\u003eSUN-16K-SG05LP3-EU-SM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3213\" data-end=\"3251\"\u003e\n\u003ctd data-start=\"3213\" data-end=\"3220\" data-col-size=\"sm\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"3220\" data-end=\"3251\" data-col-size=\"md\"\u003eThree-phase hybrid inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3252\" data-end=\"3295\"\u003e\n\u003ctd data-start=\"3252\" data-end=\"3267\" data-col-size=\"sm\"\u003eBattery type\u003c\/td\u003e\n\u003ctd data-start=\"3267\" data-end=\"3295\" data-col-size=\"md\"\u003eLead-acid or lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3296\" data-end=\"3330\"\u003e\n\u003ctd data-start=\"3296\" data-end=\"3320\" data-col-size=\"sm\"\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd data-start=\"3320\" data-end=\"3330\" data-col-size=\"md\"\u003e40–60V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3331\" data-end=\"3363\"\u003e\n\u003ctd data-start=\"3331\" data-end=\"3358\" data-col-size=\"sm\"\u003eNumber of battery inputs\u003c\/td\u003e\n\u003ctd data-start=\"3358\" data-end=\"3363\" data-col-size=\"md\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3364\" data-end=\"3411\"\u003e\n\u003ctd data-start=\"3364\" data-end=\"3403\" data-col-size=\"sm\"\u003eMaximum charging\/discharging current\u003c\/td\u003e\n\u003ctd data-start=\"3403\" data-end=\"3411\" data-col-size=\"md\"\u003e300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3412\" data-end=\"3479\"\u003e\n\u003ctd data-start=\"3412\" data-end=\"3444\" data-col-size=\"sm\"\u003eLithium-ion charging strategy\u003c\/td\u003e\n\u003ctd data-start=\"3444\" data-end=\"3479\" data-col-size=\"md\"\u003eAutomatic adaptation to the BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3480\" data-end=\"3517\"\u003e\n\u003ctd data-start=\"3480\" data-end=\"3506\" data-col-size=\"sm\"\u003eMaximum PV access power\u003c\/td\u003e\n\u003ctd data-start=\"3506\" data-end=\"3517\" data-col-size=\"md\"\u003e32,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3518\" data-end=\"3554\"\u003e\n\u003ctd data-start=\"3518\" data-end=\"3543\" data-col-size=\"sm\"\u003eMaximum PV input power\u003c\/td\u003e\n\u003ctd data-start=\"3543\" data-end=\"3554\" data-col-size=\"md\"\u003e25,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3555\" data-end=\"3590\"\u003e\n\u003ctd data-start=\"3555\" data-end=\"3582\" data-col-size=\"sm\"\u003eMaximum PV input voltage\u003c\/td\u003e\n\u003ctd data-start=\"3582\" data-end=\"3590\" data-col-size=\"md\"\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3591\" data-end=\"3618\"\u003e\n\u003ctd data-start=\"3591\" data-end=\"3610\" data-col-size=\"sm\"\u003eStart-up voltage\u003c\/td\u003e\n\u003ctd data-start=\"3610\" data-end=\"3618\" data-col-size=\"md\"\u003e160V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3619\" data-end=\"3652\"\u003e\n\u003ctd data-start=\"3619\" data-end=\"3640\" data-col-size=\"sm\"\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd data-start=\"3640\" data-end=\"3652\" data-col-size=\"md\"\u003e160–650V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3653\" data-end=\"3686\"\u003e\n\u003ctd data-start=\"3653\" data-end=\"3678\" data-col-size=\"sm\"\u003eRated PV input voltage\u003c\/td\u003e\n\u003ctd data-start=\"3678\" data-end=\"3686\" data-col-size=\"md\"\u003e550V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3687\" data-end=\"3734\"\u003e\n\u003ctd data-start=\"3687\" data-end=\"3724\" data-col-size=\"sm\"\u003eMaximum PV operating input current\u003c\/td\u003e\n\u003ctd data-start=\"3724\" data-end=\"3734\" data-col-size=\"md\"\u003e36+36A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3735\" data-end=\"3780\"\u003e\n\u003ctd data-start=\"3735\" data-end=\"3770\" data-col-size=\"sm\"\u003eMaximum PV short-circuit current\u003c\/td\u003e\n\u003ctd data-start=\"3770\" data-end=\"3780\" data-col-size=\"md\"\u003e54+54A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3781\" data-end=\"3827\"\u003e\n\u003ctd data-start=\"3781\" data-end=\"3816\" data-col-size=\"sm\"\u003eMPPT trackers \/ strings per MPPT\u003c\/td\u003e\n\u003ctd data-start=\"3816\" data-end=\"3827\" data-col-size=\"md\"\u003e2 \/ 2+2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3828\" data-end=\"3863\"\u003e\n\u003ctd data-start=\"3828\" data-end=\"3852\" data-col-size=\"sm\"\u003eRated AC active power\u003c\/td\u003e\n\u003ctd data-start=\"3852\" data-end=\"3863\" data-col-size=\"md\"\u003e16,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3864\" data-end=\"3904\"\u003e\n\u003ctd data-start=\"3864\" data-end=\"3892\" data-col-size=\"sm\"\u003eMaximum AC apparent power\u003c\/td\u003e\n\u003ctd data-start=\"3892\" data-end=\"3904\" data-col-size=\"md\"\u003e17,600VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3905\" data-end=\"3951\"\u003e\n\u003ctd data-start=\"3905\" data-end=\"3937\" data-col-size=\"sm\"\u003eRated AC input\/output current\u003c\/td\u003e\n\u003ctd data-start=\"3937\" data-end=\"3951\" data-col-size=\"md\"\u003e24.3\/23.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3952\" data-end=\"4000\"\u003e\n\u003ctd data-start=\"3952\" data-end=\"3986\" data-col-size=\"sm\"\u003eMaximum AC input\/output current\u003c\/td\u003e\n\u003ctd data-start=\"3986\" data-end=\"4000\" data-col-size=\"md\"\u003e26.7\/25.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4001\" data-end=\"4047\"\u003e\n\u003ctd data-start=\"4001\" data-end=\"4040\" data-col-size=\"sm\"\u003eMaximum continuous AC bypass current\u003c\/td\u003e\n\u003ctd data-start=\"4040\" data-end=\"4047\" data-col-size=\"md\"\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4048\" data-end=\"4104\"\u003e\n\u003ctd data-start=\"4048\" data-end=\"4070\" data-col-size=\"sm\"\u003eOff-grid peak power\u003c\/td\u003e\n\u003ctd data-start=\"4070\" data-end=\"4104\" data-col-size=\"md\"\u003e2 × rated power for 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4105\" data-end=\"4179\"\u003e\n\u003ctd data-start=\"4105\" data-end=\"4134\" data-col-size=\"sm\"\u003eRated input\/output voltage\u003c\/td\u003e\n\u003ctd data-start=\"4134\" data-end=\"4179\" data-col-size=\"md\"\u003e220\/380V, 230\/400V; 0.85Un–1.1Un; 3L+N+PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4180\" data-end=\"4237\"\u003e\n\u003ctd data-start=\"4180\" data-end=\"4203\" data-col-size=\"sm\"\u003eGrid frequency\/range\u003c\/td\u003e\n\u003ctd data-start=\"4203\" data-end=\"4237\" data-col-size=\"md\"\u003e50Hz \/ 45–55Hz; 60Hz \/ 55–65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4238\" data-end=\"4300\"\u003e\n\u003ctd data-start=\"4238\" data-end=\"4270\" data-col-size=\"sm\"\u003ePower factor adjustment range\u003c\/td\u003e\n\u003ctd data-start=\"4270\" data-end=\"4300\" data-col-size=\"md\"\u003e0.8 leading to 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4301\" data-end=\"4330\"\u003e\n\u003ctd data-start=\"4301\" data-end=\"4308\" data-col-size=\"sm\"\u003eTHDi\u003c\/td\u003e\n\u003ctd data-start=\"4308\" data-end=\"4330\" data-col-size=\"md\"\u003e\u0026lt;3% of rated power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4331\" data-end=\"4366\"\u003e\n\u003ctd data-start=\"4331\" data-end=\"4354\" data-col-size=\"sm\"\u003eDC injection current\u003c\/td\u003e\n\u003ctd data-start=\"4354\" data-end=\"4366\" data-col-size=\"md\"\u003e\u0026lt;0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4367\" data-end=\"4397\"\u003e\n\u003ctd data-start=\"4367\" data-end=\"4388\" data-col-size=\"sm\"\u003eMaximum efficiency\u003c\/td\u003e\n\u003ctd data-start=\"4388\" data-end=\"4397\" data-col-size=\"md\"\u003e97.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4398\" data-end=\"4429\"\u003e\n\u003ctd data-start=\"4398\" data-end=\"4420\" data-col-size=\"sm\"\u003eEuropean efficiency\u003c\/td\u003e\n\u003ctd data-start=\"4420\" data-end=\"4429\" data-col-size=\"md\"\u003e97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4430\" data-end=\"4456\"\u003e\n\u003ctd data-start=\"4430\" data-end=\"4448\" data-col-size=\"sm\"\u003eMPPT efficiency\u003c\/td\u003e\n\u003ctd data-start=\"4448\" data-end=\"4456\" data-col-size=\"md\"\u003e\u0026gt;99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4457\" data-end=\"4474\"\u003e\n\u003ctd data-start=\"4457\" data-end=\"4467\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"4467\" data-end=\"4474\" data-col-size=\"md\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4475\" data-end=\"4512\"\u003e\n\u003ctd data-start=\"4475\" data-end=\"4491\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"4491\" data-end=\"4512\" data-col-size=\"md\"\u003eWi-Fi, RS485, CAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4513\" data-end=\"4582\"\u003e\n\u003ctd data-start=\"4513\" data-end=\"4537\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-start=\"4537\" data-end=\"4582\" data-col-size=\"md\"\u003e-40°C to +60°C; power derating above 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4583\" data-end=\"4616\"\u003e\n\u003ctd data-start=\"4583\" data-end=\"4606\" data-col-size=\"sm\"\u003ePermissible humidity\u003c\/td\u003e\n\u003ctd data-start=\"4606\" data-end=\"4616\" data-col-size=\"md\"\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4617\" data-end=\"4650\"\u003e\n\u003ctd data-start=\"4617\" data-end=\"4640\" data-col-size=\"sm\"\u003ePermissible altitude\u003c\/td\u003e\n\u003ctd data-start=\"4640\" data-end=\"4650\" data-col-size=\"md\"\u003e3,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4651\" data-end=\"4674\"\u003e\n\u003ctd data-start=\"4651\" data-end=\"4665\" data-col-size=\"sm\"\u003eNoise level\u003c\/td\u003e\n\u003ctd data-start=\"4665\" data-end=\"4674\" data-col-size=\"md\"\u003e\u0026lt;60dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4675\" data-end=\"4703\"\u003e\n\u003ctd data-start=\"4675\" data-end=\"4695\" data-col-size=\"sm\"\u003eProtection rating\u003c\/td\u003e\n\u003ctd data-start=\"4695\" data-end=\"4703\" data-col-size=\"md\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4704\" data-end=\"4779\"\u003e\n\u003ctd data-start=\"4704\" data-end=\"4715\" data-col-size=\"sm\"\u003eTopology\u003c\/td\u003e\n\u003ctd data-start=\"4715\" data-end=\"4779\" data-col-size=\"md\"\u003eNon-isolated on the solar side; isolated on the battery side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4780\" data-end=\"4832\"\u003e\n\u003ctd data-start=\"4780\" data-end=\"4803\" data-col-size=\"sm\"\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd data-start=\"4803\" data-end=\"4832\" data-col-size=\"md\"\u003eOVC II (DC), OVC III (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4833\" data-end=\"4935\"\u003e\n\u003ctd data-start=\"4833\" data-end=\"4868\" data-col-size=\"sm\"\u003eEnclosure dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd data-start=\"4868\" data-end=\"4935\" data-col-size=\"md\"\u003e456 × 750 × 268.5mm, excluding connectors and mounting brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4936\" data-end=\"4955\"\u003e\n\u003ctd data-start=\"4936\" data-end=\"4945\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"4945\" data-end=\"4955\" data-col-size=\"md\"\u003e51.9kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4956\" data-end=\"4993\"\u003e\n\u003ctd data-start=\"4956\" data-end=\"4966\" data-col-size=\"sm\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-start=\"4966\" data-end=\"4993\" data-col-size=\"md\"\u003eIntelligent air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4994\" data-end=\"5043\"\u003e\n\u003ctd data-start=\"4994\" data-end=\"5013\" data-col-size=\"sm\"\u003eSurge protection\u003c\/td\u003e\n\u003ctd data-start=\"5013\" data-end=\"5043\" data-col-size=\"md\"\u003eType II (DC), Type II (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"fvuta6\" data-start=\"5045\" data-end=\"5077\"\u003eCompatibility and integration\u003c\/h2\u003e\n\u003cp data-start=\"5079\" data-end=\"5401\"\u003eThe inverter supports lead-acid and lithium-ion batteries within the 40–60V range. For lithium-ion batteries, the charging strategy adapts to the BMS through compatible communication. Exact compatibility depends on the battery model, BMS protocol, and firmware version. We recommend checking compatibility before purchase.\u003c\/p\u003e\n\u003cp data-start=\"5403\" data-end=\"5653\"\u003eThe string configuration must be calculated to comply with the maximum voltage of 800V, the MPPT range of 160–650V, the current limits of each tracker, and the behaviour of the modules under the extreme temperatures expected at the installation site.\u003c\/p\u003e\n\u003ch2 data-section-id=\"14uwwk1\" data-start=\"5655\" data-end=\"5679\"\u003eProtection and safety\u003c\/h2\u003e\n\u003cp data-start=\"5681\" data-end=\"6058\"\u003eThe inverter includes DC reverse-polarity protection, AC output overcurrent protection, thermal protection, AC overvoltage protection, AC output short-circuit protection, DC component monitoring, AFCI, anti-islanding protection, a DC switch, insulation impedance detection, and residual current monitoring. Surge protection is Type II on the DC side and Type II on the AC side.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1idv9g\" data-start=\"6060\" data-end=\"6101\"\u003eStandards declared by the manufacturer\u003c\/h2\u003e\n\u003cp data-start=\"6103\" data-end=\"6234\"\u003e\u003cstrong data-start=\"6103\" data-end=\"6124\"\u003eGrid regulations:\u003c\/strong\u003e IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105\u003c\/p\u003e\n\u003cp data-start=\"6236\" data-end=\"6310\"\u003e\u003cstrong data-start=\"6236\" data-end=\"6255\"\u003eSafety and EMC:\u003c\/strong\u003e IEC\/EN 61000-6-1\/2\/3\/4, IEC\/EN 62109-1, IEC\/EN 62109-2\u003c\/p\u003e\n\u003cp data-start=\"6312\" data-end=\"6467\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eSystem sizing, installation, and commissioning must be carried out by qualified personnel in accordance with DEYE documentation and applicable regulations.\u003c\/p\u003e","brand":"DEYE","offers":[{"title":"Default Title","offer_id":57952000377163,"sku":"SUN-16K-SG05LP3-EU-SM2","price":2311.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/1-2_866f5814-699e-4b3d-acab-929303a1ef26.png?v=1781008060","url":"https:\/\/solartech.eu\/es\/products\/deye-16kw-three-phase-hybrid-inverter-sun-16k-sg05lp3-eu-sm2","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}