The UDP3305C programmable DC power supply is a cost-effective, four-channel independent laboratory power supply from UNI-T. The power supply contains a classic linear transformer, and channels CH1 and CH2 allow operation in constant voltage (CV) mode in the range from 0 to 30V or in constant current (CC) mode from 0 to 5A. Channel CH3 provides a constant output voltage with the option of selecting a level of 1.8V, 2.5V, 3.3V, or 5.0V and has overload protection when the current consumption reaches 3.2A. In addition, there is a USB connector on the front panel, which serves as channel CH4 and can be used to charge, for example, a mobile phone with a voltage of 5V/2A.
CH1 and CH2 can operate independently, or they can be connected internally in series or in parallel, then the source provides a voltage from 0 to 60V or/0 to 50V or/0 30V/10A.
The laboratory source has an EBTN display with 6 high-precision indicators that simultaneously display voltages, currents, and powers in each of both channels CH1 and CH2 with 4-digit accuracy.
The power supply has programmable parameters. It has 5 memories for easy storage and recall of set modes and a lock button to prevent unwanted parameter changes. On the back of the power supply case are the USB-Device and RS232 connectors and the DIGITAL I/O interface for remote control of the power supply. Using the supplied software, it is possible to record and display the consumption or load characteristics of the connected load in real time on the connected PC in an Excel table or graph, and based on SCPI communication commands, it can communicate with the computer. Regular calibrations can be performed via software.
The source contains a temperature-controlled fan, and the long-term temperature overload of the laboratory source transformer is monitored by sensors that shut down the source when the limit value is reached and restart it after cooling.
Product parameters:
– Fine adjustment of CH1/2 current and voltages in both channels. Four-digit displays for immediate control of voltages, currents, and powers in CH1 and CH2 channels.
– voltage setting from 0 to 30V with a resolution of 10mV
– setting currents from 0 to 5A with a resolution of 1mA
– CH1 and CH2 channels operating at constant voltage, possibility of connecting CH1 channels and constant current in CH1 modes and constant current in series CH1 or constant in parallel
– Overvoltage protection (OVP), overcurrent protection (OCP), overtemperature protection (OTP)
– CH3 channel with a fixed voltage of 1.8V; 2.5V; 3.3V or 5.0V max. 3.2A
– CH4 channel on the USB connector on the front panel for charging, e.g., a mobile phone
– built-in buzzer to indicate status changes
– lock buttons to prevent unwanted changes to settings
– USB-Device interface, RS232, DIGITAL I/O on rear panel
– temperature-controlled cooling fan
– disconnection from the power supply in case of overload of the voltage transformer
– rear voltage selector
110V/120V/220V/230V (AC 50/60Hz)
Technical parameters:
– Nominal output voltage CH1 and CH2: 0 to 30V
– Nominal output current CH1 and CH2: 0 to 5 A
– total output voltage
– 30 V
resolution (CH1 and CH2): 10mV/1mA
– in (CV) mode, voltage setting accuracy (CH1 and CH2): ≤ (0.01% of the measured value +3mV, at current ≤ 3A)
– in mode (CV), voltage setting accuracy (CH1 and CH2, +5% of the measured value, d.m. current > 3A)
– in (CC) mode, current setting accuracy (CH1 and CH2): ≤ (0.2% of measured value +3mA)
– Noise and noise (20Hz to 20MHz) at CH1 and CH2 outputs: ≤1mV RMS / ≤3mA-nominal output voltage / ≤3mA RMS: nominal voltage / ≤3mA-RMS current 1.8 V; 2.5 V; 3.3 V; 5.0 V (±3%, can be set accurately)/max. 3.2 A
– Noise and hum (20Hz to 20MHz) at CH3 output: ≤2mV
– Output voltage/max. current in CH4 channel (USB): 5V ± 0.25V/2A
– Temperature coefficient of voltage/current: ≤ 300ppm/°C // ≤ 300ppm/°C
– Nominal supply voltage: AC 110V/120V/220V/220V/20V (protection)<br/0V/23 Supply 110/120V/AC): fuse type: T6.3AL/250V (20x5mm)
– protection (with 220/230/AC power supply): fuse type: T3.13AL/250V (20x5mm)
– Dimensions (width x height x depth): 16 mm x 40 x 40 mm Approx. 10.2 kg
– gross weight of the box: 12 kg
Contents of individual packaging:
– UDP3305C laboratory source: 1 piece
– power cable: 1 piece
– USB-A to USB-B interface cable (UT-D14):- 1 set of connection cables
– 1 piece
set
– spare fuses: 1 piece
– instructions for use: 1 piece
– on request RS232 communication cable: 1 pc
Packaging for bulk customers:
– standard quantity per box: 2 pieces
– standard box dimensions: 445 x 3003 mm
MANUFACTURER: UNI-T
PC software download link:
https://instruments.uni-trend.com/EU-EN/powersupplies/udp3300.html
| Weight | 1 κ. |
|---|---|
| Dimensions | 20 × 20 × 20 cm |
| Brand |
UNI-T |
Only logged in customers who have purchased this product may leave a review.
In stock
Out of stock
19,32 €Available on backorder
3.496,80 €No account yet?
Create an Account
Reviews
Clear filtersThere are no reviews yet.