Pick up from the Shop
Free pick up today
Free
-
Courier delivery
Delivery with GLS
3-5 days
-
Delivery by pallet
Delivery with DB Schenker
5-7 days
30,80 €
En stock (can be backordered)
En stock (can be backordered)
Free pick up today
Free
Delivery with GLS
3-5 days
Delivery with DB Schenker
5-7 days
Payment Methods:
UNI-T UT202R Multimeter Clamp
This product comes with a 3-year warranty. The UT202R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A, and voltage frequencies up to 600V. It has protection against voltages higher than 600V on all ranges and an audible and visual alarm. Four-digit multisegment display measuring 37 x 25 mm with backlight and fast refresh rate (3 times/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. Non-contact electric field sensor (NCV) allows detection of live conductors in two sensitivities - EFLo and EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz. Supplied probe - the tip cap on the test cables allows measurement of LV distribution in CAT III category without the risk of arcing. Without tip caps, test leads can only be measured on CAT II low voltage distribution lines. Power supply: 2 x 1.5V R03 batteries. The meter's power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is <11μA, which effectively extends battery life to approximately 400 hours.
Product parameters:
– measurement of voltage, current, and frequency of high voltage up to 600 V
– non-contact detection of the electric field (NCV)
– Temperature measurement from -1/>-°C to -100°C Multi-segment display and audible/visual alarm
– protection against voltages greater than 600 V in intervals
– automatic interval switching
– accuracy is guaranteed in the range from 1% to 100% of the interval
Technical parameters:
1. AC current measurement (ranges/resolution/accuracy):
4,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% +10)
40.00A / 0.010A / 50Hz ~ 100Hz ± 2.0%/100Hz ± (4.0% +10) 0.100 A / 50 Hz ~ 100 Hz ± (2.0% +10)
– The accuracy of frequency monitoring when measuring AC current in the range of 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz.
– overload protection at 420A
>
AC voltage measurement (range/resolution/accuracy):
4,000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% / 0.8% +5) / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5)
– Accuracy of frequency monitoring when measuring AC voltage in the range from 10Hz to ± 10kHz at a resolution of + (10kHz). 0.01 Hz to 0.01 kHz
– overload protection at 600 Vrms
– input impedance approx. 10MGΩ
3. DC voltage measurement (range/resolution/accuracy):
400.0 mV / 0.100 mV / ± (0.71 TP3T +3)
4,000V / 0.001V / ± (0.5% +2)
40.00V / 0.010V / 0.010V / 0.010V /% +3) 0.100V / ± (0.7% +3)
600V / 1,000V / ± (0.7% +3)
– input impedance approx. 10MΩ
– overload protection at 600 Vrms
4. Resistance measurement (ranges/resolution/accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000 kΩ / 0.001 kΩ / ± (0.8% +2)
40,00kΩ / 0,01kΩ / 0,01kΩ /%40.8kΩ />±2.0kΩ /> 0,1 kΩ / ± (0,8% +2)
4,000 MΩ / 0.001 MΩ / ± (2.01 TP3T +5)
40.00MΩ / 0.01MΩ / ± (2.0% +5)
– overload protection at 600 Vrms
>
Capacity measurement (range/resolution/accuracy):
4,000 nF / 0.001 nF / ± (4.01 TP3T +10)
40.00nF / 0.01nF / ± (4.0% +10)
400.0nF / ±4nF / ±4nF / ±4nF (0.01nF / ± (4.0% +10) +10)
4,000μF / 0.001μF / ± (4.0% +5)
40.00μF / 0.01μF / ± (4.0% +5)
400.0μF / 0.1μF / ± (4.0% +5.0.01μF /0.01μF / ± (4.0% +5)) 10.0%
– overload protection at 600 Vrms
6. Temperature measurement (ranges/resolution/accuracy):
-40°C to +40°C/1°C / ±4°C
+40°C to +500°C/1°C/ ±(1.5% +5)
+500°C to +1000°C/±(2°C/1°C/±(1.5% +5) +5)
-40°F to +104°F/1°F/± 6°F
+104°F to +932°F/1°F/ ± (2.0 +6)
+932°F to +1832°F/1°F/ ± (2.5% +4/7)
Checking circuit continuity:
– if the measured resistance is less than 10Ω, the DC circuit signal emits a buzzer
– if the measured resistance is greater than 31 ohms, the open circuit signal does not emit a buzzer
– open circuit voltage approximately 2.0V
– measurement in the field of overload protection
06 at overload
-0Ω Vrms
8. Diode measurement:
– in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V
– for a silicon junction, a typical voltage drop is 0.5 to 0.8V
– open circuit voltage of approximately 2.2V
– measurement in the range of 4.900 V
/>
Non-contact electric field sensor (NCV):
– allows detection of live wires in two sensitivities – EFLo and – EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz
Other parameters:
Measurement value:
HOLD: Yes
– low battery indicator: Yes
– automatic shut-off: yes
– 1.5 V battery power supply (R03): 2 pieces
– Backlit display size: 37 mm x 25 mm
– product dimensions: 215 mm x 63 mm x 36 mm
– net weight of the product:
– 24 g product color:</24-8 g gray
Package contents:
– UT202R clamp multimeter: 1 pc box: 40 pcs
– standard box dimensions: 485 mm x 295 mm x 385 mm
– standard gross weight per box: 17.1 kg
MANUFACTURER: UNI-TREND
https://www.uni-trend.com/
| Weight | 1 κ. |
|---|---|
| Dimensions | 20 × 20 × 20 cm |
| Brand |
UNI-T |
Only logged in customers who have purchased this product may leave a review.
Out of stock
19,32 €Available on backorder
3.496,80 €No account yet?
Create an Account
Reviews
Clear filtersThere are no reviews yet.