UNI-T UT363 Anemometer

SKU: 07760177

20,60 

En stock (can be backordered)

En stock (can be backordered)

22 People watching this product now!
  • Pick up from the Shop

Free pick up today

Free

  • Courier delivery

Delivery with GLS

3-5 days

  • Delivery by pallet

Delivery with DB Schenker

5-7 days

Payment Methods:

Description

UNI-T UT363 Anemometer
This product comes with a 3-year warranty. The UNI-T UT363 anemometer is a small portable instrument for measuring wind speed and temperature. The device can be used in many fields, such as industry, mining, petrochemicals, energy, navigation, fan manufacturing, exhaust and air recovery ventilation installation, and sports. Drop resistance from a height of 1 m. Backlit four-digit LCD display, measuring 32x26mm. Powered by 3x 1.5 V (AAA) batteries, automatic shutdown after 5 minutes of inactivity.

Product parameters:

– wind speed measurement range: 0 ~ 30 m/s
– large selection of speed units
– measuring the maximum, minimum, or average value

– Temperature measurement range: -10°C to 50°C
– unit selection: °C or °F
– display backlighting

Technical parameters:

– Wind speed measurement range: 0 ~ 30 m/s, resolution 0.1 m/s, accuracy ±(5% measurement +0.5)

-1. 108 km/h (for guidance only), accuracy ±(5% of measurement +15 digits)
– Wind speed measurement range: 0.7 ~ 58 knots (for guidance only), accuracy ±(5% of measurement +10 digits)
– Wind speed measurement range: 0.8 ~ ± 5%, accuracy (only for guidance 0.8%, ± 5%, accuracy for guidance) measurement +10 digits)
– Wind speed measurement range: 78 ~ 5905 ft/min (for guidance only), accuracy ±(5% of measurement +180 digits)
– Wind speed measurement range according to the Beaufort scale: 0 ~ 12 degrees (for guidance only), measurement frequency accuracy: />- 1 degree
– 1 sampling per second
– Temperature measurement range: -10°C ~ 50°C, resolution 0.1°C, accuracy ± 2°C (14°F ~ 122°F, resolution 0.2°F, accuracy ± 4°F)
– measurement of maximum, minimum, or average values: MAX / MIN / AVG: wind speed display is higher than overload speed
OLG 45m/s or the temperature is lower than -10°C or higher than 50°C, „OL” is displayed.
– „WIND CHILL” warning: if the temperature is below 0°C and the wind speed is greater than 5m/s, the „WIND CHILL” warning is displayed. NTC
– measurement pause: HOLD is displayed
– Screen backlight: yes, can be turned on/off
– automatic shutdown: yes, after 5 minutes of inactivity
– Battery discharge indication: when the voltage drops to 3.0 ~ 3.5V
– battery powered. 160 mm x 50 mm x 28 mm
– device weight: 116g
– the device is intended for: indoor use
– Operating temperature and humidity: 0°C ~ 40°C (relative humidity less than 80%), 40°C ~ 50°C (relative altitude
-50°C) 2000m
– Storage temperature and humidity: -20°C ~ 60°C (relative humidity less than 75%)

Package contents:
– UNI-T UT363 anemometer in blister pack
– 1.5V (AAA) battery: – instructions for use
– 3 pieces 1 piece

Wholesale packaging:
– standard quantity per box: 40 pieces
– standard box dimensions: 505 mm x 330 mm x 280 mm
– standard gross weight per box: 8.42 kg

MANUFACTURER
-TREND.

Specification

General

Weight 1 κ.
Dimensions 20 × 20 × 20 cm
Brand

UNI-T