UNI-T UT171B Multimeter
The UT171 series multimeters are portable multimeters with automatic and manual range switching and 4 3/4 – 4 5/6 digit resolution. The devices belong to the upper middle class, excel in quality design and reliability, and are also suitable for industrial use. They can measure AC/DC voltages and currents, resistance, diode test, continuity test, capacitance, frequency, duty cycle, temperature, 4-20mA current loop, conductivity, VFC, NCV. The devices allow data storage and connection via USB with optical isolation or via Bluetooth.
UNI-T UT171B Multimeter
Unlike the UT171A, the UT171B has a wider range of resistance and capacitance measurement and also measures conductivity (reverse resistance). The display type is VT-WLCD, the data is bright on a dark background. The display range is ± 60000 for voltages, currents, and frequencies and ± 6000 for capacitance measurements. The display includes a 31-part analog bar graph. Refresh rate of 4 to 5 times per second. The fuses are protected by tubular fuses (10A FF 10A H / 1000V fuse (10 x 38mm); mA/µA FF 800mA H / 600V fuse (6 x 32mm)). The device can test its own fuses (without opening the device). The multimeter is powered by a 7.4 V / 1800 mAh lithium battery. The measuring range can be selected automatically or manually. Test cables with CAT III 1000V and CAT IV 600V safety category tips are included.
Product parameters:
– fully comply with IEC/EN61010-1 and have double insulation
– classified as CAT III 1000V – electrical installation including three-phase distribution
– categorized as CAT IV 600V – exterior electrical installation (safety elements, start of internal installation)
– maximum display is 60000, VT-WLCD reverse display
– 60000 frequency measurement display
– Display for measuring capacity 6000
– Refresh rate for most measurements 4 to 5 times per second
– automatic voltage measurement range
– 600 mV / 1000 V
– AC current measurement ranges: 600 μA / 10 A
– DC voltage measurement ranges: 600 mV / 1000 V
– DC current measurement ranges: 600 μA / 10 A
– Voltage measurement range of 600 mV / 1000 V
– MΩ
– capacitor measurement ranges: 60.00 nF / 60.00 mF
– measurement ranges from: 60 Hz to 10 MHz
– the measurement range of the duty cycle
– conductivity measurement range 60 nS
– Temperature measurement range °C ~ -10000 °C, nickel-chromium-nickel-silicon thermocouple only up to + 230 °C)
– High precision
– Bargraph analog scale, 31 divisions
– TRMS, measurement of rms voltage, st. voltage, and currents
– During AC voltage measurement, the frequency display or voltage duty cycle can be measured on the secondary display.
– the secondary display can also measure the AC component superimposed on the DC voltage
– recording of 1000 data values
– relative measurement mode
– measurement of MAX and 1 MIN peak response
faulty wiring
– Low battery indicator
– automatic shutdown (sleep when inactive)
– Overload protection of voltage inputs
– surge protection of inputs with fast fuses
– 10MΩ input impedance
– Non-contact voltage detection without test probes
– transition of semiconductors to diodes and 3V voltage test semiconductors
– LiIon 7.4V / 1800mAh battery
– USB cable supplied with opto-electric converter, software can be downloaded from the manufacturer's website: https://meters.uni-trend.com/product/ut171-series/#Docs
– supplied with 50 V DC power supply/10 V/DC power supply option
UT-D08 Bluetooth adapter
– measurement in the electromagnetic field with an intensity of 1V/m with an additional error of 5% is also possible
Technical parameters:
(accuracy is defined at a temperature of 23°C ± 5°C and relative humidity less than or equal to 75% )
– DC voltage measurement (input impedance) is 10MΩ:
(range/resolution/accuracy)
600.00 mV / 10µV / ± 0.025 % + 5
6.0000 V / 0.1 mV / ± 0.025 % + 5 <br/0.0.0 V / ± 0.025 % + 5
+ 5
600.00 V / 10 mV / ± 0.03 % + 5
1000.0 V / 100 mV / ± 0.031 TP3T + 5
– AC voltage measurement (input impedance approx. 10M, 45 Hz) 45Hz 45Hz (range/resolution/accuracy)
600.00 mV / 10µV / ± 0.4 % + 40
6.0000 V / 0.1 mV / ± 0.025 % + 5
60,000 V / 1 mV / ± 0.000 V / 0.1 mV / ± 0.1 mV / ± 0.025 % + 5
60,000 V / 1 mV / ± 5 % / 0.50. 10mV / ± 0.03 % + 5
1000.0 V / 100 mV / ± 0.03% + 5
LoZ 100.0 V / 0.1 V / ± 2.0 % + 10
V.F.C. 600V/1000V / 0.01 V/0.1 V / ± 2.0 % + 10
– Direct current measurement:
(range / resolution / accuracy)
600.0 μA / 0.01 μA / ± 0.02 % / ± 0.02 μA / ± 0.02 %. μA / 0.1 μA / ± 0.25 % + 2
60,000 mA / 1μA / ± 0.7 % + 2
600.0 mA / 10μA / ± 0.15% + 2
6,000 A / ± 3,000 mA / ± 3.0 % + 2
10,000 A / 1m A / ± 0.5 % + 2
% (4-20mA) / 0.01% / ± 0.5 % + 2
– AC current measurement (45 Hz to 1 kHz):
0 / hour > resolution 0 / 0 μA / hour / 0.01 μA / ± 0.75 % + 20
6000.0 μA / 0.1 μA / ± 0.75 % + 20
60,000 mA / 1μA / ± 0.75 % + 20
600.00. 20
6.0000 A / 0.1 mA / ± 1.5 % + 20
10,000 A / 1 mA / ± 1.5 % + 5
– Measurement of resistance and conductivity:
/00000 A / 1m A / ± 1.5 % + 5
– Measurement of resistance and conductivity:
/0000000A / 0 / 00000 A / 0. 0.01 Ω / ± 0.05 % + 10
6,0000 kΩ / 0.1 Ω / ± 0.05 % + 2
60,000 kΩ / 1Ω / ± 0.05 % + 2
600.00 kΩ / ± 20.00 kΩ / ± 2. 6,0000 MΩ / 100 Ω / ± 0.15% + 5
60,000 MΩ / 1 kΩ / ± 3 % + 2
60.00nS / 0.01nS / ± 1 % + 10 ( S = Siemens capacitance measurement unit )
<br/capacity/measurement:
(range/resolution/accuracy)
6,000 nF / 1 pF / ± 3.0 % + 30
60.00 nF to 600.0 µF / 10pf to ± 5.0 nF / ± 5.0 pF / ± 1. 6.000 mF to 60.00 mF / 1 µF to 10 µF / ± 10 %
– Measurement of frequency and duty cycle:
(range / resolution / accuracy H 60)
0. 10,000 MHz / 0.0001 Hz to 0.001 MHz / ± 0.01 % + 5
0.1 % to 99.9 % / 0.1 % / ± 3.0 % + 40
100.0 ms to 0.100, ± µs / ± 0.100 µs / µs / ± 3.0 % + 40 0.1 % + 5
– display type: inverted backlit VT-WLCD type
– sampling frequency: 4 to 5/sec
– number of digits: 60000
– analog line: 31 segments
– Power supply: LiIon battery 7/18-40 mAh protection
18-40 mAh FF 10A H / 1000V fuse (10 x 38mm)
– mA/µA fuse protection FF 800mA H/1000V (6 x 32mm)
– instrument dimensions: 206 x 95 x 53 mm
– Weight: approx. 500 g (including batteries)
– operating temperature: 0 °C to 40 °C
– relative working humidity at 0 °C to 30 °C less than or equal to 75%, at 30 °C to 40 °C less than or equal to 50%
– device storage temperature: – 5/10 °C :
cETLus, CAT III 1000V, CAT IV 600V, double insulation, overload protection greater than 1000V
EN 61326-1: 2013; EN 61326-2-2: 2013
EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012
Compliant with UL STD: 61010-1, 61010-2-030
Certified according to CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033
– Manufacturer: UNI-TREND
–
Package contents:
– UT171B, storage case and Li-Ion-7 multimeter with 1800mAh battery – in device
– F1 fuse: 6 x 32mm FF 800mA H 1000V (6 x 32mm) – in device
– F2 fuse: 6 x 25mm FF 10A H 1000V (10 x 38mm) – in the device
– USB cable opto. converter
– Type K thermocouple (nickel-chromium-nickel-silicon) up to +230 °C)
– test cables with CAT III 1000V, CAT IV 600V tips
– DC 10V / 500mA power supply with accessories
– instructions for use in Czech/Slovak/English
| Weight | 1 κ. |
|---|---|
| Dimensions | 20 × 20 × 20 cm |
| Brand |
UNI-T |
Only logged in customers who have purchased this product may leave a review.