{"title":"UNI-T Clamp Meters","description":null,"products":[{"product_id":"uni-t-ut202bt-clamp-meter","title":"UNI-T UT202BT Clamp Meter","description":"\u003cp\u003eThis product comes with a 3-year warranty. The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth, which can automatically detect the most common parameters – AC\/DC voltage, AC current, resistance and continuity. It displays true RMS values.\u003cbr\u003e\nCapacitance measurement and non-contact voltage detection (NCV) are selected by pressing buttons. The UT202BT features a new design, high reliability and safety, as well as automatic range switching available for all functions. The dual backlit LCD display, with a maximum display value of ±9999, can simultaneously display voltage\/current, voltage\/frequency, and current\/frequency.\u003cbr\u003e\nThere is an LED light on the underside of the test leads. It is powered by two 1.5V R03 AAA batteries.\u003cbr\u003e\nThe multimeter is designed in accordance with safety standards EN61010-1\/61010-2-032 and electromagnetic compatibility standards EN61326-1\/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree.\u003c\/p\u003e\n\u003cp\u003eParameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage, AC current, resistance, capacitance, temperature and circuit continuity\u003cbr\u003e\n- Measurement of voltage and current frequency on the auxiliary display\u003cbr\u003e\n- Non-contact electric field sensor (NCV)\u003cbr\u003e\n- Dual LCD display with multi-segment backlight\u003cbr\u003e\n- Increased acoustic and visual protection against voltages of 60V and above\u003cbr\u003e\n- Automatic range switching\u003cbr\u003e\n- Accuracy guaranteed within the range of 5% to 100% of the ranges\u003cbr\u003e\n- Built-in LED torch\u003cbr\u003e\n- Powered by two 1.5V AAA R03 batteries\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003eTo ensure measurement accuracy, operating temperature range: -18°C to 28°C\u003c\/p\u003e\n\u003cp\u003e1a. AC current measurement (ranges\/resolution\/accuracy):\u003c\/p\u003e\n\u003cp\u003e9.999A \/ 0.001A \/ 50Hz to 60Hz ±(2.5%+30)\u003cbr\u003e\n99.99A \/ 0.01A \/ 50Hz to 60Hz ±(2.5% \/+60)\u003cbr to\u003e\n- minimum detectable current: 0.01A\u003cbr\u003e\n- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz\u003cbr\u003e\n- Overload protection at 60 Hz\/\u0026gt;\u003cbr\u003e AC current measurement - LPF (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6000A \/ 0.1A \/ 50Hz to 60Hz ±(4.0%+5) \/ 600A rms\u003c\/p\u003e\n\u003cp\u003e1c. AC trip current measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e99.99A \/ 0.01A \/ 50Hz to 60Hz ±(10%+10) \/ 600A rms\u003cbr\u003e\n6000A \/ 0.1A \/ 50Hz ±0% \/ 60Hz ±60Hz rms\u003c\/p\u003e\n\u003cp\u003e2a. AC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e9.999V \/ 0.001V \/ 40Hz to 400Hz ±(0.8%+3)\u003cbr\u003e\n99.99V \/ 0.010V \/ 40Hz to 400Hz ±(0.8%+3)\u003cbr\u003e\n99.99 V \/ 0.010 V \/ 40 Hz to 400 Hz ±(0.8%\/+3) 40 Hz to 400 Hz ±(0.8%+3)\u003cbr\u003e\n- The frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003cbr\u003e\n- Overload protection at 600Vrms\u003cbr\u003e\n- Minimum detectable voltage 0.6V\u003c\/p\u003e\n\u003cp\u003e2b. AC-LPF voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600 V \/ 0.1 V \/ 40 Hz to 400 Hz ±(2.0%+5) \/ 600 V rms\u003c\/p\u003e\n\u003cp\u003e3. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e9.999 V \/ 0.001 V \/ ±(0.5%+3)\u003cbr\u003e\n99.99V \/ 0.01V \/ ±(0.5%+3)\u003cbr\u003e\n600V \/ 0.1V \/ ±(0.5%+3) input\u003cbr\u003e\napprox. 10MΩ\u003cbr\u003e\n- overload protection at 600Vrms\u003cbr\u003e\n- minimum detectable voltage 0.6V\u003c\/p\u003e\n\u003cp\u003e4. Resistance measurement (ranges\/resolution\/accuracy):\u003c\/p\u003e\n\u003cp\u003e999.9Ω \/ 0.1Ω \/ ±(0.8%+3)\u003cbr\u003e\n9.999 kΩ \/ 0.001 kΩ \/ ±(0.8% + 3)\u003cbr\u003e\n99.99kΩ \/ 0.01kΩ \/ 0.01kΩ \/%+90kΩ \/%+90kΩ \/\u0026gt;±9kΩ \/ 0.1kΩ \/ ±(0.8%+3)\u003cbr\u003e\n9.999 MΩ \/ 0.001 MΩ \/ ±(1.5%+3)\u003cbr\u003e\n99.99 MΩ \/ 0.01 MΩ \/ ±(2.0%+5)\u003cbr\u003e\n- overload protection at 600 Vrms open-circuit voltage approx.\u003cbr\u003e\n- 1V\u003c\/p\u003e\n\u003cp\u003e5. Capacitance measurement (ranges\/resolution\/accuracy):\u003c\/p\u003e\n\u003cp\u003e99.99 nF \/ 0.01 nF \/ ±(4.0%+10)\u003cbr\u003e\n999.9 nF \/ 0.1 nF \/ ±(4.0%+10)\u003cbr\u003e\n9.999 nF \/ 0.001 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n99.99 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n999.9 μF \/ 0.1 μF \/ ±(4.0% + 5)\u003cbr\u003e\n9.999 mF \/ 0.001 mF \/ ±(10.001 mF \/ ±\/+10.001 mF \/ ±\/+10.09%\/+5) 0.1 mF \/ ±(10.0%+10)\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e6. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.\u003cbr\u003e\n- open-circuit voltage approx. 3.0 V\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e7. Temperature measurement:\u003c\/p\u003e\n\u003cp\u003e-40°C~1000°C \/ ±(2.0%+5)\u003c\/p\u003e\n\u003cp\u003e8. Non-contact electric field sensing (NCV):\u003cbr\u003e\n- enables acoustic detection of live conductors using a buzzer and optical detection using an LED\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- jaw opening: 28mm\u003cbr\u003e\n- measurement of maximum and minimum values: yes\u003cbr\u003e\n- yes\u003cbr\u003e\n- Yes, data hold, low battery indication (H\/\u0026gt;\u0026gt;- and low data: battery voltage is less than 2.4 V; if the battery voltage is less than approx. 2.2 V, the device cannot be switched on\u003cbr\u003e\n- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.\u003cbr\u003e\n- Drop resistance: yes, 1 m\u003cbr\u003e\n- Electromagnetic compatibility: RF ≤ 1 V\/m, general accuracy = stated accuracy ±5% of the range; if RF \u0026gt; 1 V\/m, accuracy is not specified\u003cbr\u003e\n- Operating altitude: ≤ 2000m and operating humidity \u0026lt;3000m\u003cbr\u003e\n-: (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)\u003cbr\u003e\n- storage temperature and humidity: -20 to +60°C (≤ 80%RH)\u003cbr\u003e\n- recommended calibration interval: 1 year\u003cbr\u003e\n- 1-battery power supply: 5 V–2 V (R03)\u003cbr\u003e\n- product dimensions: 201.5 × 47 × 28.5 mm\u003cbr\u003e\n- Weight: approx. 241 g (including batteries);\u003cbr\u003e\n- product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT202BT clamp multimeter: 1 pc\u003cbr\u003e\n- test leads: 1 pair\u003cbr\u003e\n- temperature probe (K): 1 pc\u003cbr\u003e\n- 2 x R03 instruction manuals\u003cbr\u003e\n- User manual: 1 copy\u003c\/p\u003e\n\u003cp\u003eManufacturer: UNI-TREND\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169280843,"sku":"07720294","price":54.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720294.jpg?v=1776539649"},{"product_id":"uni-t-ut219p-clamp-meter","title":"UNI-T UT219P Clamp Meter","description":"\u003cp\u003eThis product comes with a 3-year warranty. The UNI-T UT219P is a portable, clamp-on smart power meter. It can measure harmonics, three-phase unbalanced voltage, AC voltage, AC current, power, power factor and much more. It is widely used in photovoltaic power stations, motor manufacturing, electrical equipment and distribution boxes.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- 1000A AC current measurement\u003cbr\u003e\n- 1000V AC voltage measurement\u003cbr\u003e\n- AC and DC peak measurement\u003cbr\u003e\n- Three-phase power measurement (3000 kW)\u003cbr\u003e\n- measurement of harmonics\/THD\/power factor\/phase sequence\u003cbr\u003e\n- single-phase power measurement\u003cbr\u003e\n- Large jaw opening (up to 75 mm diameter)\u003cbr\u003e\n- True RMS measurement\u003cbr\u003e\n- Bluetooth 5.0\u003cbr\u003e\n- CAT III\/IV 100,000\/CATV0 protection\u003cbr\u003e\n- IP54\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003eAC current (A): 1000 A ±(1.5%+3)\u003cbr\u003e\nAC voltage (V): 1000 V ± (0.7% + 3)\u003cbr\u003e\nPower (single-phase): 1000 kW ±（1.7%+5）\u003cbr\u003e\nPower (three-phase and 3-wire): 1732 kW\u003cbr\u003e\nPower (three-phase and 4-wire): 3000 kW\u003cbr\u003e\nPower supply frequency (Hz): 15 Hz ～ 1000 Hz ±±3 (Hz angle\u003cbr\u003e\n(0. (-180° ~ 179.9°)\u003cbr\u003e\n15 Hz–40 Hz ±5°\u003cbr\u003e\n40 Hz ~ 70 Hz ±3°\u003cbr\u003e\n70 Hz ~ 1000 Hz ±5°\u003cbr\u003e\nPower factor: -1 to 1 based on phase angle accuracy\u003cbr\u003e\n- 7 mm\/\u0026gt;\u003c\/p\u003e\n\u003cp\u003eDetection: yes (80V–1000V) \/ positive and negative\u003cbr\u003e\n- AC\/DC PEAK measurement\u003cbr\u003e\n- 32-time harmonic measurement\u003cbr\u003e\n- LCD display\u003cbr\u003e\n- Display range: 9999\u003cbr\u003e\n- Bluetooth app: yes\u003cbr\u003e\n- True RMS: yes\u003cbr\u003e\n- Overload indication: yes\u003cbr\u003e\n- Overload indication: yes\u003cbr\u003e\n- High-voltage overload warning\u003cbr\u003e\n- Low battery indicator\u003cbr\u003e\n- Data log\u003cbr\u003e\n- Auto-off: approx. 15 minutes\u003cbr\u003e\n- max\/min: yes\u003cbr\u003e\n- power supply: 3 x AAA (R03)\u003cbr\u003e\n- dimensions: 295 x 118 x 50 mm\u003cbr\u003e\n- weight: 630 g\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169444683,"sku":"07720302","price":246.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720302.jpg?v=1776539653"},{"product_id":"uni-t-ut202t-clamp-meter","title":"UNI-T UT202T Clamp Meter","description":"\u003cp\u003eThis product comes with a 3-year warranty. The UT202T is an easy-to-use smart clamp multimeter that can automatically detect the most common parameters – AC\/DC voltage, AC current, resistance and continuity. It displays true RMS values.\u003cbr\u003e\nCapacitance measurement and non-contact voltage measurement (NCV) are selected by pressing buttons. The UT202T features a new design, high reliability and safety, as well as automatic range switching available for all functions. Dual backlit LCD screen, with a maximum display value of ±9999, can simultaneously display voltage\/current, voltage\/frequency, current\/frequency. There is an LED lamp on the underside of the test leads. It is powered by two 1.5V AAA R03 batteries.\u003cbr\u003e\nThe multimeter is designed in accordance with safety standards EN61010-1\/61010-2-032 and electromagnetic compatibility standards EN61326-1\/EN61326-2-2, and complies with CAT III 600V, double insulation and pollution degree. :\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage, AC current, resistance, capacitance and circuit continuity\u003cbr\u003e\n- measurement of voltage and current frequency on the auxiliary display\u003cbr\u003e\n- Non-contact voltage detection (NCV)\u003cbr\u003e\n- dual LCD display with multi-segment backlight\u003cbr\u003e\n- Audible and visual alarm\u003cbr\u003e\n- protection against voltage ranges exceeding 60 V\u003cbr\u003e\n- switching\u003cbr\u003e\n- accuracy guaranteed between 5% and 100% of the range\u003cbr\u003e\n- built-in LED torch\u003cbr\u003e\n- powered by two 1.5V AAA R03 batteries\u003c\/p\u003e\n\u003cp\u003eTechnical specifications:\u003c\/p\u003e\n\u003cp\u003eTo ensure measurement accuracy, the operating temperature must be within the range of 18°C to 28°C\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges\/resolution\/accuracy):\u003c\/p\u003e\n\u003cp\u003e9.999A \/ 0.001A \/ 50Hz to 60Hz ±(2.5%+30)\u003cbr\u003e\n99.99A \/ 0.01A \/ 50Hz to 60Hz ±(2.5% \/+60)\u003cbr to\u003e\n- minimum detectable current: 0.01A\u003cbr\u003e\n- frequency display during AC current measurement is standard if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz\u003cbr\u003e\n- overload protection\u003cbr\u003e\n\/\u0026gt;\u003c\/p\u003e\n\u003cp\u003e\/200 Hz\u003cbr\u003e\nAC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e9.999 V \/ 0.001 V \/ 40 Hz to 400 Hz ±(0.8%+3)\u003cbr\u003e\n99.99 V \/ 0.010 V \/ 40 Hz to 400 Hz ±(0.8% + 3)\u003cbr\u003e\n99.99 V \/ 0.010 V \/ 40 Hz to 400 Hz ±(0.8%\/+3) 40 Hz to 400 Hz ±(0.8%+3)\u003cbr\u003e\n- Frequency display on the auxiliary display during AC voltage measurement is standard if the input voltage has an amplitude ≥5Vrms at a frequency from 40Hz to 1000Hz. At frequencies above 400 Hz, accuracy is not specified.\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003cbr\u003e\n- Overload protection at 600 Vrms\u003cbr\u003e\n- Minimum detectable voltage 0.6 V\u003c\/p\u003e\n\u003cp\u003e3. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e9.999 V \/ 0.001 V \/ ±(0.5%+3)\u003cbr\u003e\n99.99 V \/ 0.01 V \/ ±(0.5% + 3)\u003cbr\u003e\n600 V \/ 0.1 V \/ ±(0.5% + 3) input\u003cbr\u003e\napprox. 10 MΩ\u003cbr\u003e\n- overload protection at 600Vrms\u003cbr\u003e\n- minimum detectable voltage 0.6V\u003c\/p\u003e\n\u003cp\u003e4. Resistance measurement (ranges\/resolution\/accuracy):\u003c\/p\u003e\n\u003cp\u003e999.9Ω \/ 0.1Ω \/ ±(0.8%+3)\u003cbr\u003e\n9.999 kΩ \/ 0.001 kΩ \/ ±(0.8% + 3)\u003cbr\u003e\n99.99 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ %+90 kΩ \/ %+90 kΩ \/ \u0026gt;±9 kΩ \/ 0.1 kΩ \/ ±(0.8%+3)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ±(1.5%+3)\u003cbr\u003e\n- overload protection at 600 Vrms\u003cbr\u003e\n- open-circuit voltage approx. 1 V\u003c\/p\u003e\n\u003cp\u003e5. Capacitance measurement (ranges\/resolution\/accuracy):\u003c\/p\u003e\n\u003cp\u003e99.99 nF \/ 0.01 nF \/ ±(4.0%+10)\u003cbr\u003e\n999.9 nF \/ 0.1 nF \/ ±(4.0%+10)\u003cbr\u003e\n9.999 nF \/ 0.001 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n99.99 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n999.9 μF \/ 0.1 μF \/ ±(4.0% + 5)\u003cbr\u003e\n9.999 mF \/ 0.001 mF \/ ±(10.001 mF \/ ±\/+10.001 mF \/ ±\/+10.09%\/+5) 0.1 mF \/ ±(10.0%+10)\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e6. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- If the measured resistance is ≤30Ω, the circuit is in good working order, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.\u003cbr\u003e\n- open-circuit voltage approximately 3.0 V\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e7. Non-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables acoustic detection of live conductors using a buzzer and visual detection using an LED\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- jaw opening: 28 mm\u003cbr\u003e\n- measurement of maximum and minimum values: yes\u003c\/p\u003e\n\u003cp\u003e-: data hold indication\u003c\/p\u003e\n\u003cp\u003e- low battery\u003c\/p\u003e\n\u003cp\u003e- yes, if the battery voltage is less than 2.4V; if the battery voltage is less than approx. 2.2V, the device cannot be switched on\u003cbr\u003e\n- auto-off: yes, the multimeter will switch off automatically if no button is pressed within 15 minutes. This feature can be disabled as required.\u003cbr\u003e\n- Drop resistance: yes, 1 m\u003cbr\u003e\n- Electromagnetic compatibility: RF ≤ 1 V\/m, overall accuracy = stated accuracy ±5% of the range; if RF \u0026gt; 1 V\/m, accuracy is not specified\u003cbr\u003e\n- Operating altitude: ≤2000m, operating temperature and humidity: +3\/0°C\u003cbr\u003e\n-0°C (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)\u003cbr\u003e\n- storage temperature and humidity: -20 to +60°C (≤ 80%RH)\u003cbr\u003e\n- recommended calibration interval: 1 year\u003cbr\u003e\n- 1-battery power supply: 5 V–2 V (R03)\u003cbr\u003e\n- Product dimensions: 201.5 × 47 × 28.5 mm\u003cbr\u003e\n- UT202T weight: approx. 241g (including batteries);\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT202T multimeter clip: 1 pc\u003cbr\u003e\n- test leads: 1 pair\u003cbr\u003e\n- 1.5 V battery (R03): 2 pcs\u003cbr\u003e\n- user manual\u003cbr\u003e\n- pcs\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 40 pcs\u003cbr\u003e\n- standard carton dimensions: 485 x 295 x 385 mm\u003cbr\u003e\n- standard gross weight of carton: approx. 17 kg\u003c\/p\u003e\n\u003cp\u003eManufacturer:\u003cbr\u003e\nUNI-TREND\u003cbr\u003e\n-\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169510219,"sku":"07720293","price":36.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720293.jpg?v=1776539657"},{"product_id":"uni-t-ut208b-clamp-meter","title":"UNI-T UT208B Clamp Meter","description":"\u003cp\u003eUNI-T UT208B Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT208B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 100000000000V at 400Hz and low voltage (mn) 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times\/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows LV distribution measurements in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only \u0026lt;50μA, which effectively extends battery life. The power-saving function can be disabled.\u003c\/p\u003e\n\u003cp\u003eProduct specifications:\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage and current, resistance, diodes, continuity, capacitance\u003cbr\u003e\n- automatic polarity display\u003cbr\u003e\n- Measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range\u003cbr\u003e of low-voltage (LV) frequency in the range 10 Hz to 1 MHz\u003cbr\u003e\n- capacitance measurement from 60 nF to 60 mF\u003cbr\u003e\n- Temperature measurement from -40 to +1000 °C with a closed K-type thermocouple\u003cbr\u003e\n- measurement of the (relative) ratio of voltages and voltages and capacitances\u003cbr\u003e\nmultiple visual protection\u003cbr protection\u003e voltages greater than 1000 V in ranges\u003cbr\u003e\n- NCV function – non-contact detection of live conductors\u003cbr\u003e\n- LoZ V function ~ measurement with low input impedance (approx. 2 kΩ) of the device\u003cbr\u003e\n- INRUSH function – measurement of transients up to 100 ms – inrush current on device start-up with an additional 3,000,000 loop at the LPF ACV function – AC voltage measurement with an NF filter (approx. 2.5 kHz) on inverters and variable-frequency drives\u003cbr\u003e\n- Frequency\/duty cycle measurement function\u003cbr\u003e\n- Choice between automatic or manual switching\u003cbr\u003e\n- Built-in lamp\u003cbr\u003e\n- Accuracy of current and voltage measurement is guaranteed when using the range from 10% to 10%; within 5% of this range, it is necessary to change the range\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 40Hz ~ 400Hz ±(2.0%+9)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(2.0%+A)\u003cbr\u003e+1 40Hz ~ 400Hz ±(2.0%+5)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz\u003cbr\u003e\n- Overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003e2. AC inrush current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 A \/ 0.010 A \/ 40 Hz ~ 400 Hz ±(10.0% + 10)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n1000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n- overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003ewith flexible current loop\u003cbr\u003e\n30.00A \/ 0.000Hz \/ 40.010Hz ±(10.0%+10)\u003cbr\u003e\n300.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n3000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10) overload protection\u003cbr\u003e\n-10 3000A\u003c\/p\u003e\n\u003cp\u003e3. DC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ ±(2.0%+5)\u003cbr\u003e\n600.0A \/ 0.100A \/ ±(2.0%+5)\u003cbr\u003e\n1000.0A \/ 1A \/ ±(2.0%+5) overload protection\u003cbr\u003e\n2.0%\/\u0026gt;-5 1000A\u003c\/p\u003e\n\u003cp\u003e4. AC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000V \/ 0.001V \/ 40Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00V \/ 0.010V \/ 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V \/ 40 Hz ~ 400 Hz ±(1.0% + 8)\u003cbr\u003e\n1000.0V \/ 1V \/ 40Hz ~ 400Hz ±(1.0%+8)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz\u003cbr\u003e\n- Overload protection at 1000 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\ninput overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e6. AC LPF V (measurement with low input impedance approx. 2 kΩ)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\n- Input overload protection rm approx. 2kΩ\u003c\/p\u003e\n\u003cp\u003e7. DC voltage measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 mV \/ 0.100 mV \/ ±(0.8%+3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ±(0.5%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ +0.05 V \/ 0.100 V \/ ±(0.5%+3)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(0.5%+3)\u003cbr\u003e\n- overload protection at 1000Vrms\u003cbr\u003e\n- input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e8. Resistance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0Ω \/ 0.1Ω \/ ±(1.0%+3)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ % + 0.0,0,0,0,0,0,0,0,Ω \/\u0026gt; 0.1 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n- overload protection at 1000 Vrms open-circuit voltage approx.\u003cbr\u003e\n- 1 V\u003c\/p\u003e\n\u003cp\u003e9. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 30Ω, the continuity signal emits a beep\u003cbr\u003e\n- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep\u003cbr\u003e\n- uncertainty between 31Ω and 69Ω\u003cbr\u003e\n- 600Ω, with a resolution of 0.1Ω\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e10. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 3.0V\u003cbr\u003e\n- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V\u003c\/p\u003e\n\u003cp\u003e11. Capacitance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n60.00 nF \/ 0.01 nF \/ ±(4.0%+25)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ±(4.0%+5)\u003cbr\u003e\n6,000 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ±(4.0%+5)\u003cbr\u003e\n6.000 mF \/ 0.001 mF \/ ±10.0% \/ 0.1 μF \/ 0.1 μF \/ ±(4.0%+5) \/ ±10.0%+9\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e12. Temperature measurement\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003cbr\u003e\n-40°C to +300°C \/ 0.1°C \/ ± 1.0°C+20\u003cbr\u003e\n+300°C to +1000°C \/ 1°C \/ ±(1.0%+2)\u003cbr\u003e\n+573°F to +1832°F \/ 1°F \/ ±(1.0%+4)\u003c\/p\u003e\n\u003cp\u003e13. Frequency measurement and operating cycle (filling)\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 1 MHz \/ 0.01 Hz to 1 kHz \/ ± (0.1% + 3)\u003cbr\u003e\nFill: 10% to 99.1% \/ ±99.0% \/ ±7)\u003c\/p\u003e\n\u003cp\u003e- Note 1) Measurement sensitivity:\u003cbr\u003e\n10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\n100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\nNote: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:\u003cbr\u003e\n2Vpp ≤ input amplitude ≤ 20V p-p\u003c\/p\u003e\n\u003cp\u003e- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e14. Non-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will start flashing. (ratio) for voltage and capacitance measurement: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- Auto power off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 43 x 45 mm\u003cbr\u003e\n- Product dimensions: 81 x 27\/4 x 81 x 27 mm. Product weight: 450g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT208B clamp multimeter: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- K-type thermocouple up to 1000°C: 1 pc\u003cbr\u003e\n3:\u003cbr\u003e\n\u0026gt;- (battery\u003cbr\u003e\n3): user manual: 1 pc\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 5 pcs\u003cbr\u003e\n- standard box dimensions: 355 mm x 330 mm x 165 mm\u003cbr\u003e\n- standard gross weight per box: 4.5 kg\u003c\/p\u003e\n\u003cp\u003eUNI-TREND MANUFACTURE\u003cbr\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169739595,"sku":"07720265","price":150.51,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720265.jpg?v=1776539658"},{"product_id":"uni-t-ut207b-clamp-meter","title":"UNI-T UT207B Clamp Meter","description":"\u003cp\u003eUNI-T UT207B Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT207B digital clamp meter is used to measure AC and DC voltages up to 1000V, AC and DC currents up to 1000A, and frequency at low voltage (LV) and current up to 10,000,000 V in the range of 1,000,000 V at 400 Hz and low voltage (LV) from 10 Hz to 1 MHz. It features protection against voltages exceeding 1,000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times\/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive Hall probe. Option to purchase a flexible loop for measuring currents up to 3000A. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only \u0026lt;50μA, which effectively extends battery life. The power-saving function can be disabled.\u003c\/p\u003e\n\u003cp\u003eProduct specifications:\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage and current, resistance, diodes, continuity, capacitance\u003cbr\u003e\n- automatic polarity display\u003cbr\u003e\n- measurement of low-voltage (LV) currents and voltages up to 1000 V-40 within the measurement range\u003cbr\u003e of low-voltage (LV) frequency in the range from 10 Hz to 1 MHz\u003cbr\u003e\n- capacitance measurement from 60 nF to 60 mF\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- Multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages higher than 10V\/0V - contact function without NC\u003cbr\u003e\n- live conductors\u003cbr\u003e\n- LoZ V function ~ measurement with low input impedance (approx. 2kΩ) of the device\u003cbr\u003e\n- INRUSH function – measurement of transients up to 100 ms in length – inrush current at device start-up up to 3000 A with additional flexible loop\u003cbr\u003e\n- LPF ACV measurement function on nf2H5 filter (approx. inverters and variable frequency drives\u003cbr\u003e\n- Frequency\/duty cycle measurement function\u003cbr\u003e\n- Choice between automatic or manual range switching\u003cbr\u003e\n- Built-in lamp\u003cbr\u003e\n- Accuracy of current and voltage measurement is guaranteed when using the range between 5% and 100% of the full scale; at 5% of the full scale, a technical adjustment is required\u003cbr\u003e\n\u0026gt;\u003cbr\u003e\nParameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 40Hz ~ 400Hz ±(2.0%+9)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(2.0%+A)\u003cbr\u003e+1 40Hz ~ 400Hz ±(2.0%+5)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz\u003cbr\u003e\n- Overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003e2. AC inrush current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 A \/ 0.010 A \/ 40 Hz ~ 400 Hz ±(10.0% + 10)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n1000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n- overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003ewith flexible current loop\u003cbr\u003e\n30.00A \/ 0.000Hz \/ 40.010Hz ±(10.0%+10)\u003cbr\u003e\n300.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n3000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10) overload protection\u003cbr\u003e\n-10 3000A\u003c\/p\u003e\n\u003cp\u003e3. DC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ ±(2.0%+5)\u003cbr\u003e\n600.0A \/ 0.100A \/ ±(2.0%+5)\u003cbr\u003e\n1000.0A \/ 1A \/ ±(2.0%+5) overload protection\u003cbr\u003e\n2.0%\/\u0026gt;-5 1000A\u003c\/p\u003e\n\u003cp\u003e4. AC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000V \/ 0.001V \/ 40Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00V \/ 0.010V \/ 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V \/ 40 Hz ~ 400 Hz ±(1.0% + 8)\u003cbr\u003e\n1000.0V \/ 1V \/ 40Hz ~ 400Hz ±(1.0%+8)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz\u003cbr\u003e\n- Overload protection at 1000 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e5. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\ninput overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e6. AC LPF V (measurement with low input impedance approx. 2 kΩ)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\n- Input overload protection rm approx. 2kΩ\u003c\/p\u003e\n\u003cp\u003e7. DC voltage measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 mV \/ 0.100 mV \/ ±(0.8%+3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ±(0.5%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ +0.05 V \/ 0.100 V \/ ±(0.5%+3)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(0.5%+3)\u003cbr\u003e\n- overload protection at 1000Vrms\u003cbr\u003e\n- input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e8. Resistance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0Ω \/ 0.1Ω \/ ±(1.0%+3)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ % + 0.0,0,0,0,0,0,0,0,Ω \/\u0026gt; 0.1 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n- overload protection at 1000 Vrms open-circuit voltage approx.\u003cbr\u003e\n- 1 V\u003c\/p\u003e\n\u003cp\u003e9. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 30Ω, the continuity signal emits a beep\u003cbr\u003e\n- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep\u003cbr\u003e\n- uncertainty between 31Ω and 69Ω\u003cbr\u003e\n- 600Ω, with a resolution of 0.1Ω\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e10. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 3.0V\u003cbr\u003e\n- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V\u003c\/p\u003e\n\u003cp\u003e11. Capacitance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n60.00 nF \/ 0.01 nF \/ ±(4.0%+25)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ±(4.0%+5)\u003cbr\u003e\n6,000 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ±(4.0%+5)\u003cbr\u003e\n6.000 mF \/ 0.001 mF \/ ±10.0% \/ 0.1 μF \/ 0.1 μF \/ ±(4.0%+5) \/ ±10.0%+9\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e12. Frequency measurement and duty cycle (duty)\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 1 MHz \/ 0.01 Hz to 1 kHz \/ ± (0.1% + 3)\u003cbr\u003e\nduty cycle: 10% to 99.1% \/ ±99.0% \/ ±7)\u003c\/p\u003e\n\u003cp\u003e- Note 1) Measurement sensitivity:\u003cbr\u003e\n10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\n100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\nNote: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:\u003cbr\u003e\n2Vpp ≤ input amplitude ≤ 20V p-p\u003c\/p\u003e\n\u003cp\u003e- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e13. Non-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- Auto power off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 43 x 45 mm\u003cbr\u003e\n- Product dimensions: 81 x 27\/4 x 81 x 27 mm. Product weight: 450g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT207B multimeter clip: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- 1.5 V battery (R03): 3 pcs\u003c\/p\u003e\n\u003cp\u003e- user manual\u003cbr\u003e\n- 1 pc\u003cbr\u003e\n- user manual\u003cbr\u003e\nPackaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 10 pcs\u003cbr\u003e\n- standard box dimensions: 355 mm x 330 mm x 315 mm\u003cbr\u003e\n- standard gross weight per box: 7.1 kg\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003cbr\u003e\nhttps:\/\/www.uni-trend\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169805131,"sku":"07720264","price":116.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720264.jpg?v=1776539661"},{"product_id":"uni-t-ut206b-clamp-meter","title":"UNI-T UT206B Clamp Meter","description":"\u003cp\u003eUNI-T UT206B Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT206B digital clamp meter is used to measure AC and DC voltages up to 1000 V, AC currents up to 1000 A, and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times\/s). The maximum value that can be displayed is 6000. The display features a 31-point analogue scale (bar graph). The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). With the closed K-type thermocouple (nickel-chromium–nickel-silicon temperature sensor), it allows temperature measurement from -40 °C to 1000 °C. The sensor is a sensitive inductive current loop. Option to purchase a flexible loop for measuring currents up to 3000 A. Power supply: 3 x 1.5 V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only \u0026lt;50μA, which effectively extends battery life. The power-saving function can be disabled.\u003c\/p\u003e\n\u003cp\u003eProduct specifications:\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage and AC current, resistance, diodes, continuity, capacitance\u003cbr\u003e\n- automatic polarity display\u003cbr\u003e\n- measurement of frequency of low-voltage (LV) currents and voltages up to 1000–40 V\/Hz\u003cbr\u003e\nmeasurement of low-voltage (LV) frequency in the range 10 Hz to 1 MHz\u003cbr\u003e\n- capacitance measurement from 60 nF to 60 mF\u003cbr\u003e\n- temperature measurement from -40 to +1000 °C with a closed K-type thermocouple\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances for alarm and multiple alarms – e.g. protection against voltages exceeding 1000 V in intervals\u003cbr\u003e\n- NCV function – non-contact detection of live conductors\u003cbr\u003e\n- LoZ V function – measurement with low input impedance (approx. 2 kΩ) of the device\u003cbr\u003e\n- INRUSH function – measurement of transients up to 100 ms – with an additional start-up duration of up to 30,000 A. loop\u003cbr\u003e\n- LPF ACV function – AC voltage measurement with low-pass filter (approx. 2.5 kHz) on inverters and variable-frequency drives\u003cbr\u003e\n- Frequency\/duty cycle measurement function\u003cbr\u003e\n- Choice between automatic or manual switching\u003cbr\u003e\n- Built-in lamp\u003cbr\u003e\n- Current and voltage accuracy are guaranteed when current and voltage measurement is within 10% of the value; if the value falls outside this range, the range must be changed\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 40Hz ~ 400Hz ±(2.0%+9)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(2.0%+A)\u003cbr\u003e+1 40Hz ~ 400Hz ±(2.0%+5)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 40 to 400 Hz is ± (0.1% + 3) at a resolution of 0.1 Hz\u003cbr\u003e\n- Overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003e2. AC inrush current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 A \/ 0.010 A \/ 40 Hz ~ 400 Hz ±(10.0% + 10)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n1000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n- overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003ewith flexible current loop\u003cbr\u003e\n30.00A \/ 0.000Hz \/ 40.010Hz ±(10.0%+10)\u003cbr\u003e\n300.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(10.0%+10)\u003cbr\u003e\n3000.0A \/ 1A \/ 40Hz ~ 400Hz ±(10.0%+10) overload protection\u003cbr\u003e\n-10 3000A\u003c\/p\u003e\n\u003cp\u003e3. AC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000V \/ 0.001V \/ 40Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00V \/ 0.010V \/ 40Hz ~ 400Hz ~ 400Hz ±(1.2%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V \/ 40 Hz ~ 400 Hz ±(1.0% + 8)\u003cbr\u003e\n1000.0V \/ 1V \/ 40Hz ~ 400Hz ±(1.0%+8)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz\u003cbr\u003e\n- Overload protection at 1000 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e4. LPF AC V (measurement with low-pass filter approx. 2.5 kHz)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\ninput overload protection at 1.0%–0.0 V at overload-rm approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e5. AC LPF V (measurement with low input impedance approx. 2 kΩ)\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 V \/ 0.1 V \/ ±(2.0%+5)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(2.0% + 5)\u003cbr\u003e\n- Input overload protection rm approx. 2kΩ\u003c\/p\u003e\n\u003cp\u003e6. DC voltage measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 mV \/ 0.100 mV \/ ±(0.8%+3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ±(0.5%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ +0.05 V \/ 0.100 V \/ ±(0.5%+3)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(0.5%+3)\u003cbr\u003e\n- overload protection at 1000Vrms\u003cbr\u003e\n- input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e7. Resistance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0Ω \/ 0.1Ω \/ ±(1.0%+3)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ % + 0.0,0,0,0,0,0,0,0,Ω \/\u0026gt; 0.1 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n- overload protection at 1000 Vrms open-circuit voltage approx.\u003cbr\u003e\n- 1 V\u003c\/p\u003e\n\u003cp\u003e8. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 30Ω, the continuity signal emits a beep\u003cbr\u003e\n- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep\u003cbr\u003e\n- uncertainty between 31Ω and 69Ω\u003cbr\u003e\n- 600Ω, with a resolution of 0.1Ω\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e9. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 3.0 V\u003cbr\u003e\n- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V\u003c\/p\u003e\n\u003cp\u003e10. Capacitance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n60.00 nF \/ 0.01 nF \/ ±(4.0%+25)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ±(4.0%+5)\u003cbr\u003e\n6,000 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ±(4.0%+5)\u003cbr\u003e\n6.000 mF \/ 0.001 mF \/ ±10.0% \/ 0.1 μF \/ 0.1 μF \/ ±(4.0%+5) \/ ±10.0%+9\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e11. Temperature measurement\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003cbr\u003e\n-40°C to +300°C \/ 0.1°C \/ ± 1.0°C+20\u003cbr\u003e\n+300°C to +1000°C \/ 1°C \/ ±(1.0%+2)\u003cbr\u003e\n+573°F to +1832°F \/ 1°F \/ ±(1.0%+4)\u003c\/p\u003e\n\u003cp\u003e12. Frequency measurement and operating cycle (filling)\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 1 MHz \/ 0.01 Hz to 1 kHz \/ ± (0.1% + 3)\u003cbr\u003e\nFill: 10% to 99.1% \/ ±99.0% \/ ±7)\u003c\/p\u003e\n\u003cp\u003e- Note 1) Measurement sensitivity:\u003cbr\u003e\n10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\n100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\nNote: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:\u003cbr\u003e\n2Vpp ≤ input amplitude ≤ 20V p-p\u003c\/p\u003e\n\u003cp\u003e- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e13. Non-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- allows detection of live wires - as the detected voltage increases, more segments of the bar graph will be displayed; with a higher value, the buzzer will sound more frequently and the LED will begin to flash. (ratio) for voltage and capacitance measurement: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- Auto power off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 43 x 45 mm\u003cbr\u003e\n- Product dimensions: 81 x 27\/4 x 81 x 27 mm. Product weight: 492g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT206B clamp multimeter: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- K-type thermocouple up to 1000°C: 1 pc\u003cbr\u003e\n3:\u003cbr\u003e\n\u0026gt;-R\u0026lt;03\/\u0026gt; user manual: 1 pc\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 10 pcs\u003cbr\u003e\n- standard box dimensions: 355 mm x 330 mm x 315 mm\u003cbr\u003e\n- standard gross weight per box: 7.1 kg\u003c\/p\u003e\n\u003cp\u003eMANUF UNI-TREND\u003cbr\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169837899,"sku":"07720263","price":83.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720263.jpg?v=1776539663"},{"product_id":"uni-t-ut205e-clamp-meter","title":"UNI-T UT205E Clamp Meter","description":"\u003cp\u003eUNI-T UT205E Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT205E digital clamp meter is used for measuring AC and DC voltages up to 1000 V, AC currents up to 1000 A and low-voltage (LV) frequencies up to 10040 V Hz and frequencies in the range of 10040 Hz and Hz. It measures currents up to 1000 A in the range of 40 Hz to 60 Hz and low-voltage (LV) frequencies from 10 Hz to 1 MHz. It features protection against voltages exceeding 1000 V and audible and visual alarms across all ranges. Four-digit multi-segment display measuring 43 x 45 mm with backlighting and a fast refresh rate (3 times\/s). The maximum displayable value is 6000. The jaw opening allows measurement on cables with a diameter of up to 42 mm. The non-contact voltage detector (NCV) allows the detection of live conductors. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, test leads can only be used on CAT II low-voltage distribution lines (e.g. 230 V sockets). The sensor is a sensitive inductive current loop. Power supply: 3 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The device has an automatic power-saving function – after 15 minutes it enters standby mode, where it consumes only \u0026lt;50μA, which effectively extends the battery life. The power-saving function can be disabled.\u003c\/p\u003e\n\u003cp\u003eProduct specifications:\u003c\/p\u003e\n\u003cp\u003e- measurement of AC\/DC voltage and AC current, resistance, diodes, continuity, capacitance\u003cbr\u003e\n- automatic polarity display\u003cbr\u003e\n- current frequency measurement in the range from 40 to 60 Hz and up to low voltages (10 Hz) V0040 at 400 Hz\u003cbr\u003e\n- Measurement of low-voltage frequency (mn) in the range from 10 Hz to 1 MHz\u003cbr\u003e\n- capacitance measurement from 60 nF to 60 mF\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- Multi-segment display and audible\/visual protection against voltages exceeding 100 V - Intervals\u003cbr\u003e\n- NCV function – non-contact detection of live conductors\u003cbr\u003e\n- Frequency\/duty cycle measurement function\u003cbr\u003e\n- Choice of automatic or manual range switching\u003cbr\u003e\n- Built-in lamp\u003cbr\u003e\n- Accuracy of current and voltage measurement is guaranteed when using the range within the 5% to 100% range; no adjustment of the 5% to 100% range is required\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 40Hz ~ 400Hz ±(2.0%+9)\u003cbr\u003e\n600.0A \/ 0.100A \/ 40Hz ~ 400Hz ±(2.0%+A)\u003cbr\u003e+1 40Hz ~ 400Hz ±(2.0%+5)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 40 to 60Hz is ± (0.1% + 3) at a resolution of 0.1Hz\u003cbr\u003e\n- Overload protection at 1000A\u003c\/p\u003e\n\u003cp\u003e2. AC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000 V \/ 0.001 V \/ 40 Hz ~ 400 Hz ±(1.2%+3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 40 Hz ~ 400 Hz ±(1.2% + 3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 40 Hz ~ 400 Hz ±(1.2% + 3) 0.100 V \/ 40 Hz ~ 400 Hz ±(1.0% + 8)\u003cbr\u003e\n1000.0V \/ 1V \/ 40Hz ~ 400Hz ±(1.0%+8)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 40 Hz to +40.01 Hz\u003cbr\u003e\n- Overload protection at 1000 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e3. DC voltage measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0 mV \/ 0.100 mV \/ ±(0.8%+3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ±(0.5% + 3)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ +0.05 V \/ 0.100 V \/ ±(0.5% + 3)\u003cbr\u003e\n1000.0 V \/ 1 V \/ ±(0.5%+3)\u003cbr\u003e\n- overload protection at 1000Vrms\u003cbr\u003e\n- input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e4. Resistance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n600.0Ω \/ 0.1Ω \/ ±(1.0%+3)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ % + 0.0,0,0,0,0,0,0,0,Ω \/\u0026gt; 0.1 kΩ \/ ±(1.0% + 2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ±(2.0%+8)\u003cbr\u003e\n- overload protection at 1000 Vrms open-circuit voltage approx.\u003cbr\u003e\n- 1 V\u003c\/p\u003e\n\u003cp\u003e5. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 30Ω, the continuity signal emits a beep\u003cbr\u003e\n- with a measured resistance greater than 70Ω, the open-circuit signal does not emit a beep\u003cbr\u003e\n- uncertainty between 31Ω and 69Ω\u003cbr\u003e\n- 600Ω, with a resolution of 0.1Ω\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e6. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 3.0V\u003cbr\u003e\n- measurement in the 000V range, with a resolution of 6.00 V, 0.001 V\u003c\/p\u003e\n\u003cp\u003e7. Capacitance measurement\u003cbr\u003e\n(range \/ resolution \/ accuracy):\u003cbr\u003e\n60.00 nF \/ 0.01 nF \/ ±(4.0%+25)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ±(4.0%+5)\u003cbr\u003e\n6.000 μF \/ 0.001 μF ±(4.0%+5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ±(4.0% + 5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ±(4.0%+5)\u003cbr\u003e\n6.000 mF \/ 0.001 mF \/ ±10.0% \/ 0.1 μF \/ 0.1 μF \/ ±(4.0%+5) \/ ±10.0%+9\u003cbr\u003e\n- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e8. Frequency measurement and duty cycle (duty)\u003cbr\u003e\n(ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 1 MHz \/ 0.01 Hz to 1 kHz \/ ± (0.1% + 3)\u003cbr\u003e\nduty cycle: 10% to 99.1% \/ ±99.0% \/ ±7)\u003c\/p\u003e\n\u003cp\u003e- Note 1) Measurement sensitivity:\u003cbr\u003e\n10 Hz to 100 kHz: 250 mVrms ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\n100 kHz to 10 MHz: 600 mV RMS ≤ input amplitude ≤ 20 V RMS\u003cbr\u003e\nNote: 2) Performance measurement (duty cycle) is applicable only to square waves from 10 Hz to 10 kHz:\u003cbr\u003e\n2Vpp ≤ input amplitude ≤ 20V p-p\u003c\/p\u003e\n\u003cp\u003e- overload protection at 1000 Vrms\u003c\/p\u003e\n\u003cp\u003e9. Non-contact electric field sensor (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables the detection of live wires - as the detected voltage increases, the buzzer will sound at a higher volume and the LED will begin to flash.\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of maximum and minimum values: yes\u003cbr\u003e\nrelative capacitance measurement mode: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- auto-off: yes\u003cbr\u003e\n- Powered by 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- backlit display size: 43 x 45 mm\u003cbr\u003e\n- Product dimensions: 272 x 81 x 43.5 mm\u003cbr\u003e\n- Net product weight\u003cbr\u003e\n- 43.5 mm\u003cbr\u003e\ncolour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT205E clamp multimeter: 1 pc\u003cbr\u003e\n- test leads: 1 pair\u003cbr\u003e\n- 1.5 V battery (R03): 3 pcs\u003cbr\u003e\n- user manual: 1 pc\u003cbr\u003e\n\u0026gt;\u003c\/p\u003e\n\u003cp\u003eStandard box packaging: 10 pcs\u003cbr\u003e\n- standard box dimensions: 355 mm x 330 mm x 315 mm\u003cbr\u003e\n- standard gross weight of box: 7.1 kg\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003cbr\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169870667,"sku":"07720262","price":70.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720262.jpg?v=1776539665"},{"product_id":"uni-t-ut204r-clamp-meter","title":"UNI-T UT204R Clamp Meter","description":"\u003cp\u003eUNI-T UT204R Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT204R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 600A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times\/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without tip caps, the test leads can only be used on low-voltage distribution lines in CAT II. With the included Type K thermocouple (nickel-chromium-nickel-silicon temperature sensor), it allows temperature measurement from -40°C to 1000°C. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Sleep mode consumption is \u0026lt;11μA, which effectively extends the battery life to approximately 400 hours.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of voltage, current and high-voltage frequency up to 600 V\u003cbr\u003e\n- frequency measurement from 10 Hz to 10 MHz\u003cbr\u003e\n- Measurement capabilities\u003cbr\u003e\n- 60 mF\u003cbr\u003e\n- Temperature measurement from -40 to +1000 °C\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages exceeding 600 V in intervals\u003cbr\u003e\n- Non-contact detection of live voltages and switching accuracy of live conductors\u003cbr\u003e\n-\u003cbr\u003e\nguaranteed within the range of 1% to 100% of the range\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00A \/ 0.010A \/ 50Hz ~ 100Hz ± (2.0% +5)\u003cbr\u003e\n600.0A \/ 0.100A \/ 50Hz ~ 100Hz ± (2.0% + 5) The accuracy of AC frequency monitoring in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz\u003cbr\u003e\n- overload protection at 620 A\u003c\/p\u003e\n\u003cp\u003e2. DC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 A \/ 0.010 A \/ ± (2.0% + 5)\u003cbr\u003e\n600.0 A \/ 0.100 A \/ ± (2.0% + 5)\u003cbr\u003e\n- overload protection at 620 A\u003cbr\u003e\n\u0026gt;\u003c\/p\u003e\n\u003cp\u003e\u0026gt;\u003cbr\u003e\n6,000V \/ 0.001V \/ 10Hz ~ 10kHz ± (1.0% +5)\u003cbr\u003e\n60.00V \/ 0.010V \/ 10Hz ~ 10kHz ± (0.8% \/ 0.0% +5) \/ 10Hz ~ 10kHz ± (0.8% +5)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to 60 kHz ± (0.5% + 2) at a resolution of 0.01 Hz to 0.01 kHz\u003cbr\u003e\n- input overload protection\u003cbr\u003e\n- 0.01 kHz\u003cbr\u003e\n- overload protection\u003cbr\u003e\n- 60\/0 V rm. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e4. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600.0 mV \/ 0.100 mV \/ ± (0.7% +3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ± (0.5% +2)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ ±0.001 V \/ ± (0.5% +2) \/ 0.100 V \/ ± (0.5% +2)\u003cbr\u003e\n- input impedance approx. 10MΩ\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e5. Resistance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600.0Ω \/ 0.1Ω \/ ± (1.0% +2)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ 60.8 kΩ ±2.0 kΩ 0.1 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ± (2.5% +5)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ± (2.5% +5)\u003cbr\u003e\n- overload protection at 600 Vrms open circuit\u003cbr\u003e\n- approx. 1V\u003c\/p\u003e\n\u003cp\u003e6. Capacitance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e60.00 nF \/ 0.01 nF \/ ± (4.0% +5)\u003cbr\u003e\n600.0 nF \/ 0.1 nF \/ ± (4.0% +5)\u003cbr\u003e\n6000 μF \/ 0.001 μF \/ ±4.0% +5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ± (4.0% +5)\u003cbr\u003e\n600.0 μF \/ 0.1 μF \/ ± (4.0% +5)\u003cbr\u003e\n6,000 mF \/ 0.001 mF \/ ± 10.0%\u003cbr mf\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e7. Temperature measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e-40°C to +40°C \/ 1°C \/ ± 4°C\u003cbr\u003e\n+40°C to +500°C\/1°C \/ ± (1.5% +5)\u003cbr\u003e\n+500°C to +1000°C\/±2°C\/1.5°C\u003c\/p\u003e\n\u003cp\u003e-40°F to +104°F \/ 1°F \/ ± 6°F\u003cbr\u003e\n+104°F to +932°F \/ 1°F \/ ± (2.0 +6)\u003cbr\u003e\n+932°F to +1832°F \/ 1°F \/ ± 4\u003cbr\u003e\n%\u003cbr\u003e\nFrequency and load measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 10 MHz \/ 0.01 Hz to 0.01 MHz \/ ± (0.1% +4)\u003cbr\u003e\nload: 0.1 to 99.9% \/ 0.1% \/ ±5)\u003cbr\u003e\nNote\/+5. Sensitivity:\u003cbr\u003e\n≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS\u003c\/p\u003e\n\u003cp\u003e- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p\u003cbr\u003e\nFrequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency\u003cbr\u003e\nOperating frequency\u003cbr\u003e\n1 kHz 30.0% ~ 70.0%\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e9. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer\u003cbr\u003e\n- if the measured resistance is greater than 31Ω, the open-circuit signal does not emit a buzzer\u003cbr\u003e\n- uncertainty in the range from 10Ω to 31Ω. 600Ω range\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e10. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 4.0V\u003cbr\u003e\n- measurement in the range of 6.000V\u003cbr\u003e\u003cbr\u003e\nNon-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of maximum and minimum values\u003c\/p\u003e\n\u003cp\u003e- relative measurement of maximum and minimum. Mode (ratio) for voltage and capacitance measurement: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- auto-off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 37 mm x 25 mm\u003cbr\u003e\n- Product dimensions: 631.5 mm x 631 mm\u003cbr\u003e\n- net product weight: 235 g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT204R clamp multimeter: 1 pc\u003cbr\u003e\n- Test leads: 1 pair\u003cbr\u003e\n- K-type thermocouple up to 101 V: 0 pcs\u003c\/p\u003e\n\u003cp\u003e(R03): 2 pcs\u003cbr\u003e\n- user manual: 1 pc\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 40 pcs\u003cbr\u003e\n- standard box dimensions: 485 mm x 295 mm x 385 mm\u003cbr\u003e\n- standard gross weight per box: 16\/F: 7 kg\u003cbr\u003e\u003cbr uni-trend\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169903435,"sku":"07720258","price":75.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720258.jpg?v=1776539666"},{"product_id":"uni-t-ut203r-clamp-meter","title":"UNI-T UT203R Clamp Meter","description":"\u003cp\u003eUNI-T UT203R Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT203R digital clamp meter is used to measure AC and DC voltages up to 600V, AC and DC currents up to 400A, and frequencies from 10Hz to 60kHz up to 1600V for low voltage. 10MHz for low voltage. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and fast refresh rate (3 times\/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is \u0026lt;11μA, which effectively extends battery life to approximately 400 hours.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of voltage, current and frequency of high voltage up to 600 V\u003cbr\u003e\n- measurement of frequencies from 10 Hz to 10 MHz\u003cbr\u003e\n- Measurement capabilities\u003cbr\u003e\n-400V\u003cbr\u003e\n- 40 mF\u003cbr\u003e\n- measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages exceeding 600V in intervals\u003cbr\u003e\n- non-contact detection of live conductors\u003cbr\u003e\n- automatic range switching\u003cbr\u003e\n- measurement accuracy of current and voltage is guaranteed to within 1% across 10% of ranges\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e40.00A \/ 0.010A \/ 50Hz ~ 100Hz ± (2.0% +5)\u003cbr\u003e\n400.0A \/ 0.100A \/ 50Hz ~ 100Hz ± (2.0% + 5) current monitoring accuracy ± 5) the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz\u003cbr\u003e\n- overload protection at 620 A\u003c\/p\u003e\n\u003cp\u003e2. DC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e40.00A \/ 0.010A \/ ± (2.0% +5)\u003cbr\u003e\n400.0 A \/ 0.100 A \/ ± (2.0% + 5)\u003cbr\u003e\n- overload protection at 620 A\u003cbr\u003e\n\u0026gt;\u003c\/p\u003e\n\u003cp\u003e\u0026gt;\u003cbr\u003e\n4.000V \/ 0.001V \/ 10Hz ~ 10kHz ± (1.0% +5)\u003cbr\u003e\n40.00V \/ 0.010V \/ 10Hz ~ 10kHz ± (0.8% \/ 0.8% +5) \/ 10Hz ~ 10kHz ± (0.8% +5)\u003cbr\u003e\n600.0V \/ 1V \/ 10Hz ~ 10kHz ± (0.8% +5)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 10Hz to 60kHz at a resolution of ±0.01 kHz\u003cbr\u003e\n- Overload protection at 600 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e4. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e400.0 mV \/ 0.100 mV \/ ± (0.7% +3)\u003cbr\u003e\n4.000 V \/ 0.001 V \/ ± (0.5% +2)\u003cbr\u003e\n40.00 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ ±0.001 V \/ ± (0.5% +2) \/ 0.100 V \/ ± (0.5% +2)\u003cbr\u003e\n600.0V \/ 1V \/ ± (0.5% +2)\u003cbr\u003e\n- input impedance approx. 10MΩ\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e5. Resistance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e400.0Ω \/ 0.1Ω \/ ± (1.0% +2)\u003cbr\u003e\n4,000 kΩ \/ 0.001 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n40.00kΩ \/ 0.01kΩ \/ 0.01kΩ \/ ±2.0% 0.8kΩ \/ ±2.0kΩ \/ 0.1kΩ \/ ± (0.8% +2)\u003cbr\u003e\n4.000 MΩ \/ 0.001 MΩ \/ ± (2.5% +5)\u003cbr\u003e\n40.00 MΩ \/ 0.01 MΩ \/ ± (2.5% +5)\u003cbr\u003e\n- overload protection at 600 Vrms open circuit\u003cbr\u003e\n- approx. 1V\u003c\/p\u003e\n\u003cp\u003e6. Capacitance measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e40.00 nF \/ 0.01 nF \/ ± (4.0% +5)\u003cbr\u003e\n400.0 nF \/ 0.1 nF \/ ± (4.0% +5)\u003cbr\u003e\n4.000 μF \/ 0.001 μF \/ ± (4.0% +5)\u003cbr\u003e\n40.00 μF \/ 0.01 μF \/ ± (4.0% +5)\u003cbr\u003e\n400.0 μF \/ 0.1 μF \/ ± (4.0% +5)\u003cbr\u003e\n4,000 μF \/ 0.001 μF \/ ± 10.0%\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e7. Frequency and load measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 10 MHz \/ 0.01 Hz to 0.01 MHz \/ ± (0.1% + 4)\u003cbr\u003e\nDuty cycle: 0.1 to 99.9% \/ 0.1% \/ ± (5)\u003cbr\u003e\nNote\/+5. Sensitivity:\u003cbr\u003e\n≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 1 MHz input amplitude: 1 MHz ~ 1 MHz ≤ 30 V RMS\u003c\/p\u003e\n\u003cp\u003e- Note 2) The duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p\u003cbr\u003e\nFrequency ≤ 1kHz Duty cycle: 10.0% ~ 95.0% Operating frequency\u003cbr\u003e\nOperating frequency\u003cbr\u003e\n1 kHz 30.0% ~ 70.0%\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e8. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer\u003cbr\u003e\n- if the measured resistance is greater than 31Ω, the open circuit signal does not emit a buzzer\u003cbr\u003e\n- uncertainty in the range from 10Ω to 31Ω. 600Ω range\u003cbr\u003e\n- Overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e9. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 4.0V\u003cbr\u003e\n- measurement in the range of 6.000V\u003cbr\u003e\u003cbr\u003e\nNon-contact voltage detection (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- Measurement of maximum and minimum values (ratio) for voltage and capacitance: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- Auto-off: yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 37 mm x 25 mm\u003cbr\u003e\n- Product dimensions: 63 mm\u003cbr\u003e\n- x 63 mm\u003cbr\u003e\n- net product weight: 235 g\u003cbr\u003e\n- product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT204R clamp multimeter: 1 pc\u003cbr\u003e\n- test leads: 1 pair\u003cbr\u003e\n- 1.5 V battery (R03): 2 pcs user manual\u003cbr\u003e\n- 1 pc\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 40 pcs\u003cbr\u003e\n- standard box dimensions: 485 mm x 295 mm x 385 mm\u003cbr\u003e\n- standard gross weight of box: 16.1 kg\u003c\/p\u003e\n\u003cp\u003eMANUFACTURED BY UNIVERSITATEA www.\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062169968971,"sku":"07720257","price":66.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720257.jpg?v=1776539667"},{"product_id":"uni-t-ut202r-clamp-meter","title":"UNI-T UT202R Clamp Meter","description":"\u003cp\u003eUNI-T UT202R Digital Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT202R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times\/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V \/ 50 \/ 60Hz and 230V \/ 50 \/ 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is \u0026lt;11μA, which effectively extends battery life to approximately 400 hours.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of voltage, current and frequency of high voltage up to 600 V\u003cbr\u003e\n- non-contact electric field detection (NCV)\u003cbr\u003e\n- Temperature measurement from -1\/\u0026gt;-°C to -100°C, multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages exceeding 600 V in intervals\u003cbr\u003e\n- automatic range switching\u003cbr\u003e\n- accuracy guaranteed within the range of 1% to 100% of the range\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e4,000 A \/ 0.001 A \/ 50 Hz ~ 100 Hz ± (4.0% + 10)\u003cbr\u003e\n40.00A \/ 0.010A \/ 50Hz ~ 100Hz ± 2.0%\/100Hz ± (4.0% +10) 0.100 A \/ 50 Hz ~ 100 Hz ± (2.0% +10)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz\u003cbr\u003e\n- overload protection at 420 A \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u0026gt;\u003cbr\u003e\nAC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e4,000 V \/ 0.001 V \/ 10 Hz to 10 kHz ± (1.0% + 5)\u003cbr\u003e\n40.00 V \/ 0.010 V \/ 10 Hz ~ 10 kHz ± (0.8% \/ 0.8% +5) \/ 10 Hz ~ 10 kHz ± (0.8% +5)\u003cbr\u003e\n600.0V \/ 1,000V \/ 10Hz ~ 10kHz ± (0.8% +5)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range from 10 Hz to ± 10 kHz at a resolution of + (10 kHz). 0.01 Hz to 0.01 kHz\u003cbr\u003e\n- Overload protection at 600 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e3. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e400.0 mV \/ 0.100 mV \/ ± (0.7% +3)\u003cbr\u003e\n4.000 V \/ 0.001 V \/ ± (0.5% +2)\u003cbr\u003e\n40.00 V \/ 0.010 V \/ 0.010 V \/ 0.010 V \/ ± (0.7% +3) 0.100 V \/ ± (0.7% +3)\u003cbr\u003e\n600 V \/ 1,000 V \/ ± (0.7% +3)\u003cbr\u003e\n- input impedance approx. 10MΩ\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e4. Resistance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e400.0Ω \/ 0.1Ω \/ ± (1.0% +2)\u003cbr\u003e\n4,000 kΩ \/ 0.001 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n40.00 kΩ \/ 0.01 kΩ \/ 0.01 kΩ \/ ±40.8 kΩ \/ ±2.0 kΩ \/ 0.1 kΩ \/ ± (0.8% +2)\u003cbr\u003e\n4,000 MΩ \/ 0.001 MΩ \/ ± (2.0% +5)\u003cbr\u003e\n40.00 MΩ \/ 0.01 MΩ \/ ± (2.0% +5)\u003cbr\u003e\n- overload protection at 600 Vrms\u003cbr\u003e\n\u0026gt;\u003c\/p\u003e\n\u003cp\u003eCapacitance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e4,000 nF \/ 0.001 nF \/ ± (4.0% +10)\u003cbr\u003e\n40.00 nF \/ 0.01 nF \/ ± (4.0% +10)\u003cbr\u003e\n400.0 nF \/ ±4 nF \/ ±4 nF \/ ±4 nF (0.01 nF \/ ± (4.0% +10) +10)\u003cbr\u003e\n4,000 μF \/ 0.001 μF \/ ± (4.0% +5)\u003cbr\u003e\n40.00 μF \/ 0.01 μF \/ ± (4.0% +5)\u003cbr\u003e\n400.0 μF \/ 0.1 μF \/ ± (4.0% +5.0,01 μF \/ 0.01 μF \/ ± (4.0% +5)) 10.0%\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e6. Temperature measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e-40°C to +40°C\/1°C \/ ±4°C\u003cbr\u003e\n+40°C to +500°C\/1°C\/ ±(1.5% +5)\u003cbr\u003e\n+500°C to +1000°C\/±(2°C\/1°C\/±(1.5% +5) +5)\u003c\/p\u003e\n\u003cp\u003e-40°F to +104°F\/1°F\/± 6°F\u003cbr\u003e\n+104°F to +932°F\/1°F\/ ± (2.0 +6)\u003cbr\u003e\n+932°F to +1832°F\/1°F\/ ± (2.5% +4\/7)\u003c\/p\u003e\n\u003cp\u003eCircuit continuity check:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer\u003cbr\u003e\n- if the measured resistance is greater than 31 ohms, the open circuit signal does not emit a buzzer\u003cbr\u003e\n- open-circuit voltage approximately 2.0V\u003cbr\u003e\n- measurement in the overload protection range\u003cbr\u003e\n06 overload\u003cbr\u003e\n-0Ω Vrms\u003c\/p\u003e\n\u003cp\u003e8. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 2.2V\u003cbr\u003e\n- measurement in the 4.900 V range\u003cbr\u003e\n\/\u0026gt;\u003cbr\u003e\nNon-contact electric field sensor (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables the detection of live wires in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V \/ 50 \/ 60Hz and 230V \/ 50 \/ 60Hz\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003eMeasurement value:\u003cbr\u003e\n\u003cbr\u003e HOLD: Yes\u003cbr\u003e\n- low battery indication: Yes\u003cbr\u003e\n- Auto-off: Yes\u003cbr\u003e\n- Power supply: 1.5 V batteries (R03): 2 pcs\u003cbr\u003e\n- Backlit display size: 37 mm x 25 mm\u003cbr\u003e\n- Product dimensions: 215 mm x 63 mm x 36 mm\u003cbr\u003e\n- Net product weight:\u003cbr\u003e\n- 24 g Product colour:24-8 g grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT202R clamp multimeter: 1 pc Box: 40 pcs\u003cbr\u003e\n- Standard box dimensions: 485 mm x 295 mm x 385 mm\u003cbr\u003e\n- standard gross weight of box: 17.1 kg\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003cbr\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170034507,"sku":"07720255","price":31.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720255.jpg?v=1776539670"},{"product_id":"uni-t-ut202f-clamp-meter","title":"UNI-T UT202F Clamp Meter","description":"\u003cp\u003eUNI-T UT202F Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT202F digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 600A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times\/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current is \u0026lt;11μA, which effectively extends battery life to approximately 400 hours.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of voltage, current and high-voltage frequency up to 600 V\u003cbr\u003e\n- non-contact electric field detection (NCV)\u003cbr\u003e\n- Frequency measurement from 10 MHz to 600 V\u003cbr\u003e\n60mF\u003cbr\u003e\n- Measurement of the (relative) ratio of voltages and capacitances\u003cbr\u003e\n- multi-segment display and audible\/visual alarm\u003cbr\u003e\n- protection against voltages exceeding 600V in ranges\u003cbr\u003e\n- automatic range switching\u003cbr\u003e\n- accuracy of current and voltage measurements guaranteed within 1% of the technical\u003c\/p\u003e\n\u003cp\u003eparameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000A \/ 0.001A \/ 50Hz ~ 100Hz ± (4.0% + 10)\u003cbr\u003e\n60.00A \/ 0.010A \/ 50Hz ~ 100Hz ± 10.0%\u003cbr\u003e\n(2.0) 0.100A \/ 50Hz ~ 100Hz ± (2.0% + 10)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz\u003cbr\u003e\n- overload protection at 620A.\u0026gt;\u003c\/p\u003e\n\u003cp\u003eAC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000 V \/ 0.001 V \/ 10 Hz ~ 10 kHz ± (1.0% + 5)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ 10 Hz ~ 10 kHz ± 0.8% \/ 50.8% \/ 0.100 V \/ 10 Hz ~ 10 kHz ± (0.8% + 5)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz overload protection at the input\u003cbr\u003e\n-0.01kHz overload\u003cbr\u003e\n-0. approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e3. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600.0 mV \/ 0.100 mV \/ ± (0.7% + 3)\u003cbr\u003e\n6,000 V \/ 0.001 V \/ ± (0.5% + 2)\u003cbr\u003e\n60.00 V \/ 0.010 V \/ ±0.7% 3)\u003cbr\u003e\n600.0 V \/ 0.100 V \/ ± (0.7% + 3)\u003cbr\u003e\n- input impedance approx. 10 MΩ\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e4. Resistance measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e600.0Ω \/ 0.1Ω \/ ± (1.0% + 2)\u003cbr\u003e\n6,000 kΩ \/ 0.001 kΩ \/ ± (0.8% + 2)\u003cbr\u003e\n60.00 kΩ \/ 0.01 kΩ \/ ± (0.01 kΩ \/ ± (0.01 kΩ) 2)\u003cbr\u003e\n600.0 kΩ \/ 0.1 kΩ \/ ± (0.8% + 2)\u003cbr\u003e\n6,000 MΩ \/ 0.001 MΩ \/ ± (2.0% + 5)\u003cbr\u003e\n60.00 MΩ \/ 0.01 MΩ \/ ± (2.0% + 5) overload protection at 6.0% + 5)\u003cbr\u003e\n-50 Vrms\u003c\/p\u003e\n\u003cp\u003e5. Capacitance measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e6,000 nF \/ 0.001 nF \/ ± (4.0% + 10)\u003cbr\u003e\n60.00 nF \/ 0.01 nF \/ ± (4.0% + 10)\u003cbr\u003e\n600.0 nF \/ 0.00% + 1.10)\u003cbr\u003e\n6,000 μF \/ 0.001 μF \/ ± (4.0% + 5)\u003cbr\u003e\n60.00 μF \/ 0.01 μF \/ ± (4.0% + 5)\u003cbr\u003e\n600.0μF \/ 0.1μF \/ ± (4.0% + 5)\u003cbr\u003e\n600.0μF \/ 0.1μF \/ ± (4.0% + 5). ± 10.0%\u003cbr\u003e\n60.00 mF \/ 0.01 mF \/ ± 10.0%\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e6. Frequency and load measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003efrequency: 10 Hz to 10 MHz \/ 0.01 Hz to 0.01 MHz \/ ± (0.1% + 4)\u003cbr\u003e\nDuty cycle: 0.1 to 99.9% \/ 0.1% \/ ± 5.0% \/ ± 5.0% Measurement sensitivity:\u003cbr\u003e\n≤100kHz: 200mVrms ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt; 100kHz ~ 1MHz: 600mV RMS ≤ input amplitude ≤ 30V RMS\u003cbr\u003e\n\u0026gt;1 V RMS input\u003cbr\u003e\n\u0026gt; 1 V RMS: amplitude ≤ 30 V RMS\u003c\/p\u003e\n\u003cp\u003e- Note 2) Duty cycle (duty ratio) measurement is applicable only for square waves ≤10kHz, amplitude: 1V p-p\u003cbr\u003e\nFrequency ≤ 1kHz Duty cycle: 10.0% ~ 95% Duty cycle: 30.0% ~ 70.0%\u003cbr\u003e\n- Overload protection at 600 V rms\u003c\/p\u003e\n\u003cp\u003e7. Circuit continuity check:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 10Ω, the continuity circuit signal triggers a buzzer\u003cbr\u003e\n- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer\u003cbr\u003e\n- open-circuit voltage approximately 2.0V\u003cbr\u003e\n- measurement in the overload protection range\u003cbr\u003e\n60-0Ω during overload\u003cbr\u003e\nVrms\u003c\/p\u003e\n\u003cp\u003e8. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 3.9V\u003cbr\u003e\n- measurement range of 6.000V\u003c\/p\u003e\n\u003cp\u003eParameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of maximum and minimum values: yes\u003cbr\u003e\n- Relative mode (ratio) measurement for voltage and capacitance: yes\u003cbr\u003e\n- HOLD: yes\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- auto-off: yes\u003cbr\u003e\n- 1.5 V battery power supply (backlit display size: 3 x 3): 25 mm\u003cbr\u003e\n- Product dimensions: 215 mm x 63 mm x 36 mm\u003cbr\u003e\n- net product weight: 248 g\u003cbr\u003e\n- Product colour: red and grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT201R clamp multimeter: 1 pc. test leads\u003cbr\u003e\n\/\u0026gt;- 1 pc. (R03): 2 pcs\u003cbr\u003e\n- user manual: 1 pc\u003c\/p\u003e\n\u003cp\u003eWholesale packaging:\u003c\/p\u003e\n\u003cp\u003e- standard quantity per box: 40 pcs\u003cbr\u003e\n- standard box dimensions: 485 mm x 295 mm x 385 mm\u003cbr\u003e\n- standard gross weight per box: 16\/F: 7 kg\u003cbr\u003e\u003cbr uni-trend\u003e\nhttps:\/\/www.uni-trend\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170100043,"sku":"07720256","price":28.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720256.jpg?v=1776539671"},{"product_id":"uni-t-ut201r-clamp-meter","title":"UNI-T UT201R Clamp Meter","description":"\u003cp\u003eUNI-T UT201R Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. The UT201R digital clamp meter is used to measure AC and DC voltages up to 600V, AC currents up to 400A and voltage frequencies up to 600V. It features protection against voltages exceeding 600V across all ranges, as well as an audible and visual alarm. Four-digit multi-segment display measuring 37 x 25 mm with backlighting and a fast refresh rate (3 times\/s). The jaw opening allows measurement on cables with a diameter of up to 28 mm. The non-contact electric field sensor (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and EFHi – for low-voltage distribution at 110V \/ 50 \/ 60Hz and 230V \/ 50 \/ 60Hz. Probe supplied – the tip cap on the test leads allows measurement of LV distribution in CAT III without the risk of arcing. Without the tip caps, the test leads can only be used for measurements on low-voltage distribution lines in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s power consumption is approx. 1.8 mA. The circuit has an automatic power-saving function. Standby current consumption is \u0026lt;11μA, which effectively extends battery life to approximately 400 hours.\u003c\/p\u003e\n\u003cp\u003eProduct parameters:\u003c\/p\u003e\n\u003cp\u003e- measurement of voltage, current and frequency of high voltage up to 600 V\u003cbr\u003e\n- non-contact electric field detection (NCV)\u003cbr\u003e\n- Alarm display and visual protection greater than the audible signal\/e.g. 600 V in intervals\u003cbr\u003e\n- automatic range switching\u003cbr\u003e\n- accuracy guaranteed within the range of 1% to 100% of the range\u003c\/p\u003e\n\u003cp\u003eTechnical parameters:\u003c\/p\u003e\n\u003cp\u003e1. AC current measurement (ranges \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e4,000 A \/ 0.001 A \/ 50 Hz ~ 100 Hz ± (4.0% + 10)\u003cbr\u003e\n40.00A \/ 0.010A \/ 50Hz ~ 100Hz ± 100.0%\u003cbr\u003e\n(2.0) 0.100A \/ 50Hz ~ 100Hz ± (2.0% + 10)\u003cbr\u003e\n- the frequency monitoring accuracy when measuring AC current in the range from 50 to 100 Hz is ± (1.0% + 5) at a resolution of 0.1 Hz\u003cbr\u003e\n- Overload protection at 420A.\u0026gt;\u003c\/p\u003e\n\u003cp\u003eAC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e4,000 V \/ 0.001 V \/ 10 Hz ~ 10 kHz ± (1.0% + 5)\u003cbr\u003e\n40.00 V \/ 0.010 V \/ 10 Hz ~ 10 kHz ± 0.8% \/ 50.8% 0.100 V \/ 10 Hz ~ 10 kHz ± (0.8% + 5)\u003cbr\u003e\n600.0V \/ 1.000V \/ 10Hz ~ 10kHz ± (0.8% + 5)\u003cbr\u003e\n- frequency monitoring accuracy when measuring AC voltage within the resolution range from 1.0% ± 5 at 1.0kHz to 0.01 Hz up to 0.01 kHz\u003cbr\u003e\n- Overload protection at 600 Vrms\u003cbr\u003e\n- Input impedance approx. 10 MΩ\u003c\/p\u003e\n\u003cp\u003e3. DC voltage measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e400.0 mV \/ 0.100 mV \/ ± (0.7% + 3)\u003cbr\u003e\n4.000 V \/ 0.001 V \/ ± (0.5% + 2)\u003cbr\u003e\n40.00 V \/ 0.00 V \/ ±0.3)\u003cbr\u003e\n400.0V \/ 0.100V \/ ± (0.7% + 3)\u003cbr\u003e\n600 V \/ 1.000 V \/ ± (0.7% + 3)\u003cbr\u003e\n- input impedance approx. 10MΩ\u003cbr\u003e\n- overload protection at 600 Vrms\u003c\/p\u003e\n\u003cp\u003e4. Resistance measurement (range \/ resolution \/ accuracy):\u003c\/p\u003e\n\u003cp\u003e400.0Ω \/ 0.1Ω \/ ± (1.0% + 2)\u003cbr\u003e\n4,000 kΩ \/ 0.001 kΩ \/ ± (0.8% + 2)\u003cbr\u003e\n40.00 kΩ \/ 0.01 kΩ \/ ± (0.01 kΩ \/ ± (0.01 kΩ) 2)\u003cbr\u003e\n400.0 kΩ \/ 0.1 kΩ \/ ± (0.8% + 2)\u003cbr\u003e\n4,000 MΩ \/ 0.001 MΩ \/ ± (2.0% + 5)\u003cbr\u003e\n40.00MΩ \/ 0.01MΩ \/ ± (2.0% + 5) overload protection at 6.0% + 5)\u003cbr\u003e\n-50 Vrms\u003c\/p\u003e\n\u003cp\u003e5. Checking circuit continuity:\u003c\/p\u003e\n\u003cp\u003e- if the measured resistance is less than 10Ω, the continuity circuit signal emits a buzzer\u003cbr\u003e\n- if the measured resistance is greater than 31 ohms, the open-circuit signal does not emit a buzzer\u003cbr\u003e\n- open-circuit voltage approximately 2.0V\u003cbr\u003e\n- measurement in the overload protection range\u003cbr\u003e\n06 overload\u003cbr\u003e\n-0Ω Vrms\u003c\/p\u003e\n\u003cp\u003e6. Diode measurement:\u003c\/p\u003e\n\u003cp\u003e- in the forward direction, the voltage drop across the semiconductor junction is less than or equal to 2.0V\u003cbr\u003e\n- for a silicon junction, a typical voltage drop is 0.5 to 0.8V\u003cbr\u003e\n- open-circuit voltage of approximately 2.2V\u003cbr\u003e\n- within the 4,000 V measurement range\u003c\/p\u003e\n\u003cp\u003e7. Non-contact electric field sensing (NCV):\u003c\/p\u003e\n\u003cp\u003e- enables the detection of live conductors in two sensitivity modes – EFLo and EFHi – for low-voltage distribution at 110V\/50\/60Hz and 230V\/50\/60Hz.\u003c\/p\u003e\n\u003cp\u003eOther parameters:\u003c\/p\u003e\n\u003cp\u003e- maximum and minimum measurement value HOLD\u003cbr\u003e\n- year\u003cbr\u003e\n- low battery indicator: yes\u003cbr\u003e\n- auto-off: yes\u003cbr\u003e\n- 1.5 V battery power supply (R03): 2 pcs\u003cbr\u003e\n- backlit display size: 37 mm x 25 mm\u003cbr\u003e\n- product dimensions: 215 mm x 63 mm x 36 mm\u003cbr\u003e\n- net product weight: 2\/4 g\u003cbr\u003e\n- grey\u003c\/p\u003e\n\u003cp\u003ePackage contents:\u003c\/p\u003e\n\u003cp\u003e- UT201R clamp multimeter: 1 pc 40 pcs\u003cbr\u003e\n- Standard box dimensions: 485 mm x 295 mm x 385 mm\u003cbr\u003e\n- standard gross weight of box: 16.6 kg\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003cbr\u003e\nhttps:\/\/www.uni-trend.com\/\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170165579,"sku":"07720254","price":29.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720254.jpg?v=1776539673"},{"product_id":"uni-t-ut210d-clamp-meter","title":"UNI-T UT210D Clamp Meter","description":"\u003cp\u003eUNI-T UT210D Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UT210D Clamp Meter\u003cbr\u003e\nThe UT210 series mini clamp meters are designed to perform well in confined spaces. They are essential tools for the maintenance of mechanical and electrical equipment, the installation of household appliances and electrical work.\u003c\/p\u003e\n\u003cp\u003e1. NCV\u003cbr\u003e\n2. Ergonomic and lightweight\u003cbr\u003e\n3. Automatic range, sampling rate of 2–3 times per second\u003cbr\u003e\n4. True RMS\u003cbr\u003e\n5. ZERO mode\u003cbr\u003e\n6. LCD backlight, data hold\u003cbr\u003e\n7. Auto power off, low battery indicator\u003c\/p\u003e\n\u003cp\u003eSpecifications: Range\u003cbr\u003e\nAC current (A): 200A ±(2.5%+8)\u003cbr\u003e\nDC current (A): 200A ±(2%+3)\u003cbr\u003e\nAC voltage (V): 600V ±(1%+3)\u003cbr\u003e\nDC voltage (V\/\u0026gt;60)\u003cbr\u003e\n±(0.7%+3)\u003cbr\u003e\nResistance (Ω): 20MΩ ±(1%+2)\u003cbr\u003e\nFrequency (Hz): 60kHz ±(0.1%+4)\u003cbr\u003e\nCapacitance (F): 20mF ±(4%+5)\u003cbr\u003e\nTemperature:\u003cbr\u003e\n±0°C ±0%+4)\u003cbr\u003e\n-40~1832℉ ±(1.5%+5)\u003c\/p\u003e\n\u003cp\u003eFeatures:\u003cbr\u003e\nDisplay count: 2000\u003cbr\u003e\nContinuity buzzer √\u003cbr\u003e\nAutomatic range 　 √\u003cbr\u003e\nJaw opening 　\/\u0026gt;170 mm\u003cbr\u003e\n17 mm\u003c\/p\u003e\n\u003cp\u003eGeneral features:\u003cbr\u003e\nPower: 1.5V battery (R03) x 2\u003cbr\u003e\nDisplay: 39.3 mm x 26.5 mm\u003cbr\u003e\nProduct colour: red and grey\u003cbr\u003e\nNet product weight: 170g\u003cbr\u003e\nProduct dimensions: 175mm x 3.5mm x 3.5mm x 3.5mm Accessories: batteries, test leads, spot contact temperature probe\u003cbr\u003e\nStandard individual packaging: gift box, English manual, carrying case\u003cbr\u003e\nStandard quantity per box: 40 pcs\u003c\/p\u003e\n\u003cp\u003ewww.uni-trend.com\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170231115,"sku":"07720244","price":79.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720244.jpg?v=1776539674"},{"product_id":"uni-t-ut210c-clamp-meter","title":"UNI-T UT210C Clamp Meter","description":"\u003cp\u003eUNI-T UT210C Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT210C Clamp Meter\u003c\/p\u003e\n\u003cp\u003eTECHNICAL SPECIFICATIONS\u003cbr\u003e\nAC Current (A) 2A\/20A\/200A\u003cbr\u003e\n20A+\/200A ±\/200A ±\/200A\u003cbr\u003e\nVoltage (V) 2V\/20V\/200V\/600V ±(1.0%+3)\u003cbr\u003e\nDC Voltage (V) 200mV\/2V\/20V\/200V\/600V ±(0.7%+3)\u003cbr\u003e\nResistance (Ω) 200Ω\/2kΩ\/M20kΩ\/20kΩ\/M200Ω\/20kΩ ±(1.0%+2)\u003cbr\u003e\nCapacitance (F) 20nF\/200nF\/2μF\u003cbr\u003e\n\/20μF\/200μF\/2mF\/20mF ±(4%+5)\u003cbr\u003e\nTemperature (℃) -40~1000℃) ±(1℉\/+3)\u003cbr\u003e\nTemperature -40~1832℉ ±(1.5%+5)\u003c\/p\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\nDisplay count 　 2000\u003cbr\u003e\nAuto range 　 √\u003cbr\u003e\nJaw capacity 　 17mm\u003cbr\u003e\nTrue RMS 　\/\u0026gt;V 　\/\u0026gt;√ √ A.\u003cbr\u003e\nNCV 　 √\u003cbr\u003e\nAuto shut-off: Approx. 15 minutes √\u003cbr\u003e\nContinuity buzzer 　 √\u003cbr\u003e\nLow battery indication ≤2.5V √\u003cbr\u003e\nData hold 　 √\u003cbr\u003e\nMAX mode\/√　\/√ Relative\u003cbr\u003e\n√\u003cbr\u003e\nLCD backlight 　 √\u003cbr\u003e\nInput protection 　 √\u003cbr\u003e\nInput impedance for DCV ≥10MΩ √\u003c\/p\u003e\n\u003cp\u003eGENERAL SPECIFICATIONS\u003cbr\u003e\nPower supply: 2 x 1.5V AAA batteries\u003cbr\u003e\nNet product dimensions LCD 329.3mm\u0026gt; Weight 170 g\u003cbr\u003e\nProduct dimensions 175 mm x 60 mm x 33.5 mm\u003c\/p\u003e\n\u003cp\u003eACCESSORIES\u003cbr\u003e\nBattery, test lead, contact-point temperature probe\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER\u003cbr\u003e\nUNI-TREND\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170263883,"sku":"07720220","price":54.08,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720220.jpg?v=1776539675"},{"product_id":"uni-t-ut213c-clamp-meter","title":"UNI-T UT213C Clamp Meter","description":"\u003cp\u003eUNI-T UT213C Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT213C Clamp Multimeter\u003c\/p\u003e\n\u003cp\u003eTECHNICAL SPECIFICATIONS\u003cbr\u003e\nAC Current (A) 4A\/40A\/400A\u003cbr\u003e\n40A+\/2.005A+\/(DC) (A) 40A\/400A ±(2.0%+3)\u003cbr\u003e\nAC Voltage (V) 4V\/40V\/400V\/600V ±(1.2%+5)\u003cbr\u003e\nDC Voltage (V) 400mV\/4V\/40V\/400V\/600V\/400V\/600V ±()\u003cbr\u003e\nCapacitance (F) 50nF\/500nF\/5μF\/50μF\/100μF\u003cbr\u003e\n40nF\/400nF\/4μF\/40μF\/400μF\/4mF\/40mF ±(4.0%+5)\u003cbr\u003e\nFrequency 10Hz~1MHz ±(0.1%+4)\u003cbr\u003e\nTemperature (℃) -40~1000℃)(1.0%+±3) -40~1832℉ ±(1.0%+6)\u003c\/p\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\nDisplay count 　 4000\u003cbr\u003e\nAuto range 　 √\u003cbr\u003e\nMax. jaw capacity 　 30mm\u003cbr\u003e\nTrue RMS 　\/\u0026gt;Diodes\u003cbr\u003e\n√ 3.0 V\u003cbr\u003e\nNCV 　 √\u003cbr\u003e\nData hold 　 √\u003cbr\u003e\nRelative mode 　 √\u003cbr\u003e\nMAX\/MIN 　 √\u003cbr\u003e\nLCD backlight 　 √\u003cbr\u003e\nFlashlights 　 √ Auto power off 　\/\u0026gt;√ Auto power off\u003cbr\u003e\nContinuity buzzer 　 √\u003cbr\u003e\nLow battery indication ≤3.6V √\u003cbr\u003e\nInput protection 　 √\u003cbr\u003e\nInput impedance for DCV ≥10MΩ √\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES SIZE 5V\u0026gt; AAA 1.\u003cbr\u003e\n38 mm x 24 mm\u003cbr\u003e\nNet product weight 231.7g\u003cbr\u003e\nProduct dimensions 220 mm x 75 mm x 40 mm\u003c\/p\u003e\n\u003cp\u003eACCESSORIES\u003cbr\u003e\nBattery, test lead, contact-point temperature probe\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER\u003cbr\u003e\nUNI-TREND\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170296651,"sku":"07720188","price":70.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720188.jpg?v=1776539678"},{"product_id":"uni-t-ut210a-clamp-meter","title":"UNI-T UT210A Clamp Meter","description":"\u003cp\u003eUNI-T UT210A Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT210A Mini Clamp\u003c\/p\u003e\n\u003cp\u003e* small AC clamp\u003cbr\u003e\n* sensitive\u003cbr\u003e\n* input protection\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e\n\u003cp\u003e2 AC current\/A20A0\u003cbr\u003e\n±(1.0%+9)\u003c\/p\u003e\n\u003cp\u003eFEATURES\u003c\/p\u003e\n\u003cp\u003eDisplay range 2000\u003cbr\u003e\nJaw capacity 17mm\u003cbr\u003e\nData hold\u003cbr\u003e\nLCD backlight\u003cbr\u003e\nAuto power off\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput protection\u003c\/p\u003e\n\u003cp\u003eTOTAL POWER\u003c\/p\u003e\n\u003cp\u003eTOTAL POWER: (2x)\u003cbr\u003e\nLCD size: 39.3 x 26.5 mm\u003cbr\u003e\nWeight: 160g\u003cbr\u003e\nDimensions: 155x60x33.5mm\u003c\/p\u003e\n\u003cp\u003eACCESSORIES\u003cbr\u003e\nBattery, manual\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170362187,"sku":"07720194","price":23.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720194.jpg?v=1776539680"},{"product_id":"uni-t-ut210b-clamp-meter","title":"UNI-T UT210B Clamp Meter","description":"\u003cp\u003eUNI-T UT210B Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT210B Mini Clamp\u003c\/p\u003e\n\u003cp\u003e* small AC clamp\u003cbr\u003e\n* sensitive\u003cbr\u003e\n* input protection\u003cbr\u003e\n* TRMS\u003cbr\u003e\n* NCV\/ACTION\u003c\/p\u003e\n\u003cp\u003eACTION\u003cbr\u003e\nCurrent\u003cbr\u003e\n2A\/20A\/200A ±(1.0%+9)\u003c\/p\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\nDisplay range 2000\u003cbr\u003e\nTRMS\u003cbr\u003e\nNCV\u003cbr\u003e\nMAX\/MIN\u003cbr\u003e\nRelative mode\u003cbr\u003e\nJaw capacity 17mm\u003cbr\u003e\nData Hold\u003cbr\u003e\nAuto stop\u003cbr\u003e\nAuto shut-off\u003cbr\u003e\nLCD Battery indicator\u003cbr\u003e\nInput protection\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES\u003cbr\u003e\nPower: 1.5V AAA (2x)\u003cbr\u003e\nLCD size: 39.3 x 26.5 mm\u003cbr\u003e\nWeight: 160g\u003cbr\u003e\nDimensions: 155 x 60 x 33.5 mm,\u003cbr\u003e\nBattery\u003cbr\u003e\n\/\u003cbr\u003e\nBattery Manual\u003c\/p\u003e\n\u003cp\u003eMANUFACTURER: UNI-TREND\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170394955,"sku":"07720191","price":26.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720191.jpg?v=1776539681"},{"product_id":"uni-t-ut213a-clamp-meter","title":"UNI-T UT213A Clamp Meter","description":"\u003cp\u003eUNI-T UT213A Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT213A Digital Clamp Meter\u003c\/p\u003e\n\u003cp\u003e* up to 400A\u003cbr\u003e\n* multifunctional tool for electricians\u003cbr\u003e\n* medium-sized jaws\u003cbr\u003e\nV 30mm* handy flashlight\u003cbr\u003e\nV\u003cbr\u003e\nfunction\u003cbr\u003e\n* modern input protection\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC currents 4A\/40A\/400A ±(1.8%+9)\u003cbr\u003e\nAC voltage 4V\/40V\/400V\/600V ±(1.2%+5)\u003cbr\u003e\nDC voltage 400mV\/40V\/40V\/40V\/40V ±(0.8%+1)\u003cbr\u003e\nResistance 400Ω\/4kΩ\/40kΩ\/400kΩ\/4MΩ\/40MΩ ±(1.0%+2)\u003cbr\u003e\nFrequency 10Hz–1MHz ±(0.1%+4)\u003c\/p\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\nAutomatic display\u003cbr\u003e\nawJ00\u003cbr\u003e\nAutomatic display Capacity 30 mm\u003cbr\u003e\nDiode test\u003cbr\u003e\nNCV\u003cbr\u003e\nData retention\u003cbr\u003e\nRelative mode\u003cbr\u003e\nLCD backlight\u003cbr\u003e\nFlashlight\u003cbr\u003e\nAuto power off\u003cbr\u003e\nContinuity buzzer\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput protection\u003cbr\u003e\nInput impedance for DCV \u0026gt;\/\u0026gt;\u003cbr\u003e\nFEATURES\u003cbr\u003e\nPower: 3x AAA 1.5V\u003cbr\u003e\nLCD size: 38x24mm\u003cbr\u003e\nWeight: 280g\u003cbr\u003e\nDimensions: 220x75x40mm\u003c\/p\u003e\n\u003cp\u003eACCESSORIES\u003cbr\u003e\nBattery, test leads, manual\u003cbr\u003e\n\/\u0026gt;UNI-\u0026gt;TREND\u003cbr\u003e\n\/-\u0026gt;Manufacturer\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170427723,"sku":"07720186","price":40.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720186.jpg?v=1776539683"},{"product_id":"uni-t-ut213b-clamp-meter","title":"UNI-T UT213B Clamp Meter","description":"\u003cp\u003eUNI-T UT213B Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT213B Digital Clamp Meter\u003c\/p\u003e\n\u003cp\u003e* up to 400A\u003cbr\u003e\n* TRMS\u003cbr\u003e\n* multifunctional tool for electricians\u003cbr\u003e\n* practical jaws\u003cbr\u003e\n* medium-sized jaws\u003cbr\u003e\n3*mm NCV function\u003cbr\u003e\n* temperature measurement\u003cbr\u003e\n* modern input protection\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC current 4A\/40A\/400A ±(1.8%+9)\u003cbr\u003e\nAC voltage 4V\/40V\/400V\/600V ±(1.2%+5) DC voltage\u003cbr\u003e\n400mV\/4V\/40V\/400V\/600V ±(0.8%+1)\u003cbr\u003e\nResistance 400Ω\/4kΩ\/40kΩ\/400kΩ\/4MΩ\/40MΩ ±(1.0%+2)\u003cbr\u003e\nCapacitance 40nF\/400nF\/4μF\/40μF\/400μF\/4mF\/40mF ±(4.0%+5%)\u003cbr\u003e\nFrequency 10Hz–1MHz ±(0.1%+4)\u003cbr\u003e\nTemperature -40°C–1000°C* ±(Display\/Display)\u003cbr\u003e\nCount 4000\u003cbr\u003e\nAutomatic range\u003cbr\u003e\nMax. jaw capacity 30mm\u003cbr\u003e\nTrue RMS\u003cbr\u003e\nDiode test\u003cbr\u003e\nNCV\u003cbr\u003e\nData hold\u003cbr\u003e\nRelative mode\u003cbr\u003e\nMAX\/MIN\u003cbr\u003e\nLCD backlight\u003cbr\u003e\nFlashlights\u003cbr\u003e\nAuto power off\u003cbr\u003e\nAuto-off indicator\u003cbr\u003e\nContinuity\u003cbr\u003e\nBattery indicator Protection\u003cbr\u003e\nInput impedance for DCV \u0026gt;10MΩ\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES\u003cbr\u003e\nPower: 3x AAA 1.5V\u003cbr\u003e\nLCD size: 38x24mm\u003cbr\u003e\nWeight: 280g\u003cbr\u003e\nDimensions: 220x75x75x40mm,\u003cbr\u003e\nCC\/\u0026gt;\u003c\/p\u003e\n\u003cp\u003eTest battery Temperature probe, manual, contact type* (up to 230°C)\u003c\/p\u003e\n\u003cp\u003eManufacturer: UNI-TREND\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170460491,"sku":"07720187","price":51.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720187.jpg?v=1776539684"},{"product_id":"uni-t-ut220-clamp-meter","title":"UNI-T UT220 Clamp Meter","description":"\u003cp\u003eUNI-T UT220 Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT220 Clamp Meter - 2000A\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC currents\u003cbr\u003e\n200A\/2000A\u003cbr\u003e\nAccuracy ±5\/2% AC. Voltage\u003cbr\u003e\n2V\/20V\/200V\/1000V\u003cbr\u003e\nAccuracy ±(1.2%+5)\u003cbr\u003e\nDirect voltage\u003cbr\u003e\n2V\/20V\/200V\/750V\u003cbr\u003e\nAccuracy ±(0.8%+1)\u003cbr\u003e\nResistance\u003cbr\u003e\n200Ω\/2kΩ\/20kΩ\/200kΩ\/2MΩ\/20MΩ\u003cbr\u003e\nAccuracy ±(1%+2)\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u003cbr\u003e\nDisplay range 2000\u003cbr\u003e\nAutorange\u003cbr\u003e\nDiomm\u003cbr\u003e\nAutorange Test capacity\u003cbr\u003e\nContinuity test\u003cbr\u003e\nData Hold\u003cbr\u003e\nMax mode\u003cbr\u003e\nDisplay backlight\u003cbr\u003e\nSignature display\u003cbr\u003e\nAuto power off\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput impedance 10MΩ+\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES\u003cbr\u003e\nPower: 9V battery \/ Dimensions: 298x100x48mm\u003cbr\u003e\nLCD size: 43x30mm\u003cbr\u003e\nWeight: 390g\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170493259,"sku":"07720177","price":62.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720177.jpg?v=1776539686"},{"product_id":"uni-t-ut222-clamp-meter","title":"UNI-T UT222 Clamp Meter","description":"\u003cp\u003eUNI-T UT222 Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty.\u003c\/p\u003e\n\u003cp\u003eUNI-T UT222 Clamp Meter - 2500A\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC\u003cbr\u003e\n600A\/2500A ±(1)\u003cbr\u003e\n+5(1). Current\u003cbr\u003e\n600A\/2500A ±(1.5%+5)\u003cbr\u003e\nAC voltage\u003cbr\u003e\n6V\/60V\/600V\/1000V ±(1%+3)\u003cbr\u003e\nDirect voltage\u003cbr\u003e\n6V\/60V\/600V\/750V ±(0.5%+2)\u003cbr\u003e\nResistance\u003cbr\u003e\n600Ω\/6kΩ\/60kΩ\/600kΩ\/6MΩ\/600MΩ ±(1%+2)\u003cbr\u003e\nFrequency\u003cbr\u003e\n60Hz\/600Hz\/6kHz\/60kHz\/600kHz\/600kHz\/600MHz\/600MHz ±(0.1%+3)\u003cbr\u003e\nTemperature\u003cbr\u003e\n-40°C ~ 1000°C* ±(1%+10)\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u003cbr\u003e\nDisplay count 6000\u003cbr\u003e\nAutomatic range\u003cbr\u003e\nJaw opening 63mm\u003cbr\u003e\nTRMS\/Pass-band\u003cbr\u003e\nPass filter\u003cbr\u003e\nD Current\u003cbr\u003e\nRelative function\u003cbr\u003e\nDiode test\u003cbr\u003e\nContinuity buzzer\u003cbr\u003e\nData hold\u003cbr\u003e\nMax mode\u003cbr\u003e\nAnalogue Bar graph 61\u003cbr\u003e\nData logging 1000\u003cbr\u003e\nI-OUT function\u003cbr\u003e\nDisplay illumination\u003cbr\u003e\nIconic display\u003cbr\u003e\nPower\/Auto-off indicator\u003cbr\u003e\nPower\/auto-off indicator 10MΩ+\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES\u003cbr\u003e\nPower supply: 9V alkaline battery\u003cbr\u003e\nDimensions: 298x100x48mm\u003cbr\u003e\nLCD size: 43x30mm\u003cbr\u003e\nWeight: 725g\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170558795,"sku":"07720179","price":232.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720179.jpg?v=1776539688"},{"product_id":"uni-t-ut216c-clamp-meter","title":"UNI-T UT216C Clamp Meter","description":"\u003cp\u003eUNI-T UT216C Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT216C\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC currents 60A\/600A ± (2.5%+5)\u003cbr\u003e\nDirect currents 60A\/±200A\/600A\u003cbr\u003e\nAC voltage 6V\/60V\/600V\/750V ±(1.2%+5)\u003cbr\u003e\nDC voltage 600mV\/6V\/60V\/600V\/1000V ±(0.8%+1)\u003cbr\u003e\nResistance 600Ω\/6kΩ\/60kΩ\/600kΩ\/6MΩ\/6MΩ\/6MΩ ±(1%+2)\u003cbr\u003e\nCapacitance 60nF\/600nF\/6μF\/60μF\/600μF\/6mF\/60mF ±(4%+5)\u003cbr\u003e\nFrequency 10Hz ~ 1MHz ±(0.1%+4)\u003cbr\u003e\nTemperature -100°C ±(2%+10)*\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u003cbr\u003e\nDisplay count 6000\u003cbr\u003e\nAutomatic range\u003cbr\u003e\nJaw capacity 30mm\u003cbr\u003e\nTrue RMS\u003cbr\u003e\nDiode test\u003cbr\u003e\nNCV\u003cbr\u003e\nVCF\u003cbr\u003e\nData retention\u003cbr\u003e\nMinimum current mode\/Regraf\u003cbr\u003e\nMaximum current\u003cbr\u003e\nZero 61\u003cbr\u003e\nDisplay backlight\u003cbr\u003e\nLED torch\u003cbr\u003e\nAuto power off\u003cbr\u003e\nContinuity buzzer\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput protection\u003cbr\u003e\nDC input impedance 10MΩ+\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES\u003cbr\u003e\nPower 3x 1.5V\u003cbr\u003e\nDimensions 220x75x40mm\u003cbr\u003e\nLCD size 38x24mm\u003cbr\u003e\nWeight 231.7g\u003c\/p\u003e\n\u003cp\u003eACCESSORIES: carrying case, test leads, batteries, manual, contact-type temperature probe\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170624331,"sku":"07720175","price":104.39,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720175.jpg?v=1776539690"},{"product_id":"uni-t-ut216b-clamp-meter","title":"UNI-T UT216B Clamp Meter","description":"\u003cp\u003eUNI-T UT216B Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT216B\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC current 60A\/600A ± (2.5%+5)\u003cbr\u003e\nAC voltage 6V\/60V\/7V\/60V\/7 ±(1.2%+5)\u003cbr\u003e\nDC voltage 600mV\/6V\/60V\/600V\/1000V ±(0.8%+1)\u003cbr\u003e\nResistance 600Ω\/6kΩ\/60kΩ\/600kΩ\/6MΩ\/60MΩ ±(1%+2)\u003cbr\u003e\nCapacitance 99.99 nF\/999.9 nF\/9.999 μF\/99.99 μF\/999.9 μF\/9.999 mF\/59.99 mF ±(4%+5)\u003cbr\u003e\nFrequency 10Hz–1MHz\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u0026lt;br\/6Automatic display\u0026lt;br\/6J00\/6J00\/6J Capacity 30 mm\u003cbr\u003e\nTrue RMS\u003cbr\u003e\nDiode test\u003cbr\u003e\nNCV\u003cbr\u003e\nVFC\u003cbr\u003e\nData hold\u003cbr\u003e\nRel\/Max\/Min mode\u003cbr\u003e\nDisplay backlight\u003cbr\u003e\nLED torch\u003cbr\u003e\nAuto shut-off\u003cbr\u003e\nContinuity buzzer\u003cbr\u003e\nBattery charge indicator\u003cbr\u003e\nDC input indicator\u003cbr\u003e\nDC input indication\u003cbr\u003e\n10MΩ+\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES\u003cbr\u003e\nPower 3x 1.5V AAA\u003cbr\u003e\nDimensions 220x75x40mm\u003cbr\u003e\nLCD size 38x24mm\u003cbr\u003e\nWeight 231.7g\u003c\/p\u003e\n\u003cp\u003eACCESSORIES: manual, carrying case, battery\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170722635,"sku":"07720174","price":73.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720174.jpg?v=1776539691"},{"product_id":"uni-t-ut216a-clamp-meter","title":"UNI-T UT216A Clamp Meter","description":"\u003cp\u003eUNI-T UT216A Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT216A\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC current 6A\/60A\/600A ± (2.5%+5)\u003cbr\u003e\nAC voltage 6V\/6V0V\/6V\/6V0V\/6V\/60V ±(1.2%+5)\u003cbr\u003e\nDirect voltage 600mV\/6V\/60V\/600V\/1000V ±(0.8%+1)\u003cbr\u003e\nResistance 600Ω\/6kΩ\/60kΩ\/600kΩ\/6MΩ\/60MΩ ±(1%+2)\u003cbr\u003e\nCapacitance 99.99 nF\/999.9 nF\/9.999 μF\/99.99 μF\/999.9 μF\/9.999 mF\/59.99 mF ±(4%+5)\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u003cbr\u003e\nDisplay range 6000\u003cbr\u003e\nAutomatic range\u003cbr\u003e\nTruJ\u003cbr\u003e\nTruJ\u003cbr\u003e\nTruJ RMS\u003cbr\u003e\nDiode test\u003cbr\u003e\nNCV\u003cbr\u003e\nData hold\u003cbr\u003e\nRel\/max\/min mode\u003cbr\u003e\nDisplay backlight\u003cbr\u003e\nLED torch\u003cbr\u003e\nAuto-off\u003cbr\u003e\nContinuity tester\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput protection\u003cbr\u003e\nInput impedance\u003cbr\u003e\nGENERAL 10MΩ\/+DC SPECIFICATIONS\u003cbr\u003e\nPower 3x 1.5V AAA\u003cbr\u003e\nDimensions 220x75x40mm\u003cbr\u003e\nLCD size 38x24mm\u003cbr\u003e\nWeight 231.7g\u003c\/p\u003e\n\u003cp\u003eACCESSORIES: Carrying case, battery, test leads, manual\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170755403,"sku":"07720173","price":58.65,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720173.jpg?v=1776539693"},{"product_id":"uni-t-ut221-clamp-meter","title":"UNI-T UT221 Clamp Meter","description":"\u003cp\u003eUNI-T UT221 Clamp Multimeter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT221 Clamp Meter - 2000A\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC currents\u003cbr\u003e\n660A\/2000A ±(2.5%\/2000A + 60 mA\/2000A)\u003c\/p\u003e\n\u003cp\u003eAC CURRENT\u003cbr\u003e\n±(2.5%+5)\u003cbr\u003e\nAC voltage\u003cbr\u003e\n6.6V\/66V\/660V\/1000V ±(1.2%+5)\u003cbr\u003e\nDC voltage\u003cbr\u003e\n6.6V\/66V\/660V\/750V ±(0.8%+1)\u003cbr\u003e\nResistance\u003cbr\u003e\n660 Ω\/6.6 kΩ\/66 kΩ\/666 kΩ\/6.6 MΩ\/66 MΩ ±(1%+2)\u003cbr\u003e\nFrequency\u003cbr\u003e\n66 Hz\/660 Hz\/6.6 kHz\/66 kHz\/660 kHz\/660 kHz\/66. ±(0.1%+3)\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u003c\/p\u003e\n\u003cp\u003eDisplay number 6600\u003cbr\u003e\nAutomatic radius\u003cbr\u003e\nJaw opening 63mm\u003cbr\u003e\nTRMS\u003cbr\u003e\nDuty cycle\u003cbr\u003e\nLow-pass filter\u003cbr\u003e\nIgnition current\u003cbr\u003e\nRelative function\u003cbr\u003e\nContinuous test\u003cbr\u003e\nContinuity\u003cbr\u003e\nData Hold\u003cbr\u003e\nMax\/min mode\u003cbr\u003e\nAnalogue Bar graph 66\u003cbr\u003e\nI-OUT function\u003cbr\u003e\nDisplay backlight\u003cbr\u003e\nLogo display\u003cbr\u003e\nAuto power off\u003cbr\u003e\nLow battery indication\u003cbr\u003e\nInput impedance 10MΩ+\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES:\u003cbr\u003e\nPower:\u003cbr\u003e\nV\/\u0026gt;Battery 298x100x48mm\u003cbr\u003e\nLCD size: 43x30mm\u003cbr\u003e\nWeight: 725g\u003c\/p\u003e\n\u003cp\u003eACCESSORIES: Test leads, battery, carrying case, manual\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170820939,"sku":"07720178","price":129.54,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720178.jpg?v=1776539694"},{"product_id":"uni-t-ut210e-clamp-meter","title":"UNI-T UT210E Clamp Meter","description":"\u003cp\u003eUNI-T UT210E Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT210E – small clamp multimeter\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS\u003cbr\u003e\nAC currents\u003cbr\u003e\n2A\/20A\/100A ±(2.5%+5A0)\u003cbr\u003eA0\u003cbr\u003e\nA0\u003cbr\u003e\nA0 ±(2.5%+3)\u003cbr\u003e\nAC voltage\u003cbr\u003e\n2V\/20V\/200V\/600V ±(1%+3)\u003cbr\u003e\nDirect voltage ±(0.7%+3)\u003cbr\u003e\nResistance\u003cbr\u003e\n200Ω\/2kΩ\/20kΩ\/200kΩ\/2MΩ\/200kΩ\/2MΩ ±(1%+2)\u003cbr\u003e\nCapacitance\u003cbr\u003e\n2nF\/20nF\/200nF\/2μF\/20μF\/200μF\/2mF\/20mF ±(4%+5)\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS\u003cbr\u003e\nDisplay count 2000\u003cbr\u003e\nJ Auto open\u003cbr\u003e\n17 mm\u003cbr\u003e\nTRMS\u003cbr\u003e\nDiode test\u003cbr\u003e\nNCV\u003cbr\u003e\nData hold\u003cbr\u003e\nZero mode\u003cbr\u003e\nDisplay backlight\u003cbr\u003e\nAuto power off\u003cbr\u003e\nContinuity buzzer\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput protection\u003cbr\u003e\nInput impedance DCV\/GENERAL+10MΩ\/GENERAL\u0026gt; FEATURES\u003cbr\u003e\nPower: 2x1.5V AAA batteries\u003cbr\u003e\nWeight: 170g\u003cbr\u003e\nDimensions: 175x60x33mm\u003cbr\u003e\nLCD size: 39x26mm\u003c\/p\u003e\n\u003cp\u003eACCESSORIES: battery, test leads, carrying case\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170886475,"sku":"07720170","price":62.47,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720170.jpg?v=1776539696"},{"product_id":"uni-t-ut211b-clamp-meter","title":"UNI-T UT211B Clamp Meter","description":"\u003cp\u003eUNI-T UT211B Clamp Meter\u003cbr\u003e\nThis product comes with a 3-year warranty. UNI-T UT211B\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS:\u003cbr\u003e\nAC currents\u003cbr\u003e\n600mA\/6000mA\/60A ±(1.5%+10)\u003cbr\u003e\n60A DC\u003cbr\u003e\n\/\u0026gt;600\u003cbr\u003e\nA ±(2%+3)\u003cbr\u003e\nAC voltage\u003cbr\u003e\n6V\/60V\/600V ±(0.8%+3)\u003cbr\u003e\nDirect voltage\u003cbr\u003e\n600mV\/6V\/60V\/600V ±(0.7%+3)\u003cbr\u003e\nResistance\u003cbr\u003e\n600%+3)\u003cbr\u003e\nDirect voltage\u003cbr\u003e\n600 mV\/6 V\/60 V\/600 V ±(0.7% + 3)\u003cbr\u003e\nResistance\u003cbr\u003e\n600%+3) ±(0.8%+2)\u003cbr\u003e\nCapacitance\u003cbr\u003e\n6.2 nF–62 mF ±(4%+5)\u003c\/p\u003e\n\u003cp\u003eFUNCTIONS:\u003cbr\u003e\nDisplay range 6000\u003cbr\u003e\nAutomatic range\u003cbr\u003e\nTRMS\u003cbr\u003e\nDiode test\u003cbr\u003e\nVFC mode\u003cbr\u003e\nD\u003cbr\u003e\nNCVD\u003cbr\u003e\nD Backlight\u003cbr\u003e\nAuto power off\u003cbr\u003e\nContinuity buzzer\u003cbr\u003e\nLow battery indicator\u003cbr\u003e\nInput protection\u003cbr\u003e\nInput impedance DCV 10MΩ+\u003c\/p\u003e\n\u003cp\u003eGENERAL FEATURES:\u003cbr\u003e\nPower: 2x1.5V AAA batteries\u003cbr\u003e\nWeight: 170g\u003cbr\u003e\nDimensions: 175x60x33mm\u003cbr\u003e\nDisplay size: 39.3x26.5mm\u003c\/p\u003e\n\u003cp\u003eACCESSORIES: Carrying case, batteries, test leads, manual\u003c\/p\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":57062170952011,"sku":"07720172","price":133.74,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/files\/07720172.jpg?v=1776539697"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/3323\/6043\/collections\/Clampmetre.png?v=1776944050","url":"https:\/\/solartech.eu\/collections\/uni-t-clamp-meters.oembed","provider":"SolarTech - Solar Inverters, PV Modules, Solar Accessories, ESS Battery","version":"1.0","type":"link"}